ETC2 MC-161 High quality power cord Datasheet

High Quality Power Cord
UL Certificated
Dimensions : Millimetres
Plug Component
Dimension
Colour
Component
Qty
Strip
ROJ
Colour
35P (Black)
ME-301 (Nema 5-15P)
1
6 +1/-0
22 ±2
Brown (L)
Nickel-plated
4.75 GEM 98475ABS-1
(#14-#18) (Earth Pins Terminal)
1
6 +1/-0
22 ±2
Blue (N)
6 +1/-0
22 ±2
Green-Yellow
(E)
6.3×15 (#16-18)
Nickel-plated
GEM 98675BBS-1 (Solid Blades)
Black
301-1 (5-15P Inner Body)
2
1
Connector Component
Instruction
Qty.
Wire Styles
SJT 16AWGx3C
(CEE Cord)
60°C Black
Length : 2
,006.6mm ±50.8mm
79" ±2"
Dimensions
Colour
ME-302 (IEC 60320, C13,
13A, 125V)
1
35p (Black)
2.0 × 4.0 GEM 98740LBS-0
(#16-18) Receptacle Terminal
3
Brass-Natural
GA005-5
(2.0 × 4.0 Serial Housing)
1
Off-White
ROJ
Strip
Colour
16±1
5 +1/-0
Brown (L)
16±1
5 +1/-0
Blue (N)
16±1
5 +1/-0
Green-Yellow
(E)
Dimensions : Millimetres
www.element14.com
www.farnell.com
www.newark.com
Page <1>
31/12/15
V1.0
High Quality Power Cord
UL Certificated
Note:
1. Hi-Pot Test : 1,500V/1Sec; <0.5mA
2. Insulation Resistance Test : DC 500/min>100mΩ
3. Continuity & Polarization Test : No short circuit, break circuit, displacement.
4. Each end terminal shall be capable of withstanding a pull of 25lbs for 1 minutes without loosening.
5. Strain relief shall be capable of withstanding a pull of 35lbs for 1 minutes without loosening.
6. All material according to Non-toxic standard.
Part Number Table
Description
Part Number
5-15P to C13, SJT, CEE, 16/3C, 13A 125V
MC-161
Important Notice : This data sheet and its contents (the “Information”) belong to the members of the Premier Farnell group of companies (the “Group”) or are licensed to it. No licence is granted
for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change
without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any
error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any
assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the
Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence.
Multicomp is the registered trademark of the Group. © Premier Farnell plc 2012.
www.element14.com