MPD MHI215S-03DI5.7 High isolation, 2w sip single & dual output dc/dc converter Datasheet

MHI200DI5.7Series
High Isolation, 2W SIP
Single & Dual Output
DC/DC Converters
Electrical Specifications
Key Features:
• 2W Output Power
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min.
5 VDC Input
4.5
12 VDC Input 10.8
15 VDC Input 13.5
24 VDC Input 21.6
Capacitor Filter
• 5.7 kV Isolation
• 15 kV/µS CMTI
Input Voltage Range
• 40 Standard Models
• Miniature SIP Case
Input Filter
Typ.
5.0
12.0
15.0
24.0
Max.
5.5
13.2
16.5
26.4
Units
Typ.
Max.
±5.0
±1.0
Units
%
%
%
100
±0.02
mV P - P
%/°C
Max.
Units
VDC
• -40°C to +80°C Operation
Output
• Industry Standard Pin-Out Parameter
• Low Cost
Conditions
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 2
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
Min.
Dual Output, Balanced Loads
±0.1
For VIN Change of 1%
±1.2
See Model Selection Guide
See Note 3
±0.01
Momentary (0.5S Max)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Common Mode Transient Immunity
Switching Frequency
Conditions
Rated For 60 Sec
Tested For 1 Sec
500 VDC
100 kHz, 1V
Min.
5,200
5,700
10
Typ.
VDC
G
pF
kV/µS
kHz
7
15
100
Environmental
Parameter
Conditions
Ambient
Case
Operating Temperature Range
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Min.
-40
Typ.
+25
-55
Free Air Convection
RH, Non-condensing
Max.
+80
+95
+125
Units
95
%
°C
°C
See Mechanical Diagram (Page 3)
Non-Conductive Black Plastic (UL94-V0)
0.08 Oz (2.4g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
2.0
Typ.
Max.
Units
MHours
Min.
Typ.
Max.
9.0
18.0
20.0
30.0
260
Units
Absolute Maximum Ratings
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Conditions
Input Voltage Surge (0.1 Sec)
Lead Temperature
5 VDC Input
12 VDC Input
15 VDC Input
24 VDC Input
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Nominal
5
5
5
5
5
5
5
5
5
Range
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
MHI205D-1509DI5.7
5
4.5 - 5.5
MHI212S-03DI5.7
MHI212S-05DI5.7
MHI212S-09DI5.7
MHI212S-12DI5.7
MHI212S-15DI5.7
MHI212D-05DI5.7
MHI212D-09DI5.7
MHI212D-12DI5.7
MHI212D-15DI5.7
12
12
12
12
12
12
12
12
12
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
MHI212D-1509DI5.7
12
10.8 - 13.2
MHI215S-03DI5.7
MHI215S-05DI5.7
MHI215S-09DI5.7
MHI215S-12DI5.7
MHI215S-15DI5.7
MHI215D-05DI5.7
MHI215D-09DI5.7
MHI215D-12DI5.7
MHI215D-15DI5.7
15
15
15
15
15
15
15
15
15
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
13.5 - 16.5
MHI215D-1509DI5.7
15
13.5 - 16.5
MHI224S-03DI5.7
MHI224S-05DI5.7
MHI224S-09DI5.7
MHI224S-12DI5.7
MHI224S-15DI5.7
MHI224D-05DI5.7
MHI224D-09DI5.7
MHI224D-12DI5.7
MHI224D-15DI5.7
24
24
24
24
24
24
24
24
24
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
MHI224D-1509DI5.7
24
21.6 - 26.4
MHI205S-03DI5.7
MHI205S-05DI5.7
MHI205S-09DI5.7
MHI205S-12DI5.7
MHI205S-15DI5.7
MHI205D-05DI5.7
MHI205D-09DI5.7
MHI205D-12DI5.7
MHI205D-15DI5.7
Output
Current (mA)
Voltage
Full-Load No-Load (VDC)
446
35
3.3
500
35
5.0
493
35
9.0
492
35
12.0
501
35
15.0
513
35
±5.0
504
35
±9.0
504
35
±12.0
501
35
±15.0
+15.0
495
35
-9.0
181
17
3.3
211
17
5.0
206
17
9.0
202
17
12.0
201
17
15.0
211
17
±5.0
207
17
±9.0
205
17
±12.0
199
17
±15.0
+15.0
204
17
-9.0
143
16
3.3
169
16
5.0
160
16
9.0
162
16
12.0
155
16
15.0
165
16
±5.0
160
16
±9.0
164
16
±12.0
161
16
±15.0
+15.0
159
16
-9.0
90
12
3.3
108
12
5.0
103
12
9.0
102
12
12.0
101
12
15.0
108
12
±5.0
104
12
±9.0
104
12
±12.0
103
12
±15.0
+15.0
102
12
-9.0
Notes:
1. The specified maximum capacitive load is for each output.
2. Load regulation is measured over a range of 20% IOUT to 100% IOUT.
3. When measuring output ripple & noise, it is recommended that an external capacitor
(1 µF typ.) be placed from the +VOUT to the -VOUT pins for single output units and from
each output to common for dual output models.
4. The converter should be connected to a low ac-impedance source. An input
source with a highly inductive impedance may affect the stability of the converter.
In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure
start-up. In this case, it is recommended that a low ESR (ESR <1.0⍀ at 100 kHz)
capacitor be mounted close to the converter. For 5V input units a 2.2 µF is recommended; for 12V & 15V input units, a 1.0 µF; and for 24V units a 0.47 µF.
5. Operation at no-load will not damage the unit, but they may not meet all specifications.
6. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection tables for the correct rating.
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
Current
Current
(mA, Max)
(mA, Min)
500
400
222
168
132
±200
±112
±84
±66
66
-110
500
400
222
168
132
±200
±112
±84
±66
66
-110
500
400
222
168
132
±200
±112
±84
±66
66
-110
500
400
222
168
132
±200
±112
±84
±66
66
-110
10.0
8.0
4.4
3.4
2.6
±4.0
±2.2
±1.7
±1.3
1.3
-2.2
10.0
8.0
4.4
3.4
2.6
±4.0
±2.2
±1.7
±1.3
1.3
-2.2
10.0
8.0
4.4
3.4
2.6
±4.0
±2.2
±1.7
±1.3
1.3
-2.2
10.0
8.0
4.4
3.4
2.6
±4.0
±2.2
±1.7
±1.3
1.3
-2.2
Fuse
Capacitive
Load
Efficiency Regulation
Rating
Load
(%, Typ)
Slow-Blow
(%, Max)
(µF, Max)
(mA)
74
80
81
82
79
78
80
80
79
±20.0
±15.0
±10.0
±10.0
±10.0
±15.0
±10.0
±10.0
±10.0
80
±10.0
76
79
81
83
82
79
81
82
83
±20.0
±15.0
±10.0
±10.0
±10.0
±15.0
±10.0
±10.0
±10.0
81
±10.0
77
79
83
83
85
81
84
82
82
±20.0
±15.0
±10.0
±10.0
±10.0
±15.0
±10.0
±10.0
±10.0
83
±10.0
76
77
81
82
82
77
81
81
80
±20.0
±15.0
±10.0
±10.0
±10.0
±15.0
±10.0
±10.0
±10.0
81
±10.0
1,650
940
940
440
440
440
440
200
200
200
440
1,650
940
940
440
440
440
440
200
200
200
440
1,650
940
940
440
440
440
440
200
200
200
440
1,650
940
940
440
440
440
440
200
200
200
440
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
500
500
500
500
300
300
300
300
300
300
300
300
300
300
300
200
200
200
200
200
200
200
200
200
200
200
Derating Curve
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
IGBT Applications
Notes:
The MHI200x-xxD series is a good choice for IGBT
applications. They are designed to withstand the
extra stress caused by the high voltage switching
transients present in IGBT drive circuits.
The MHI2xxD-1509DI5.7 models are specifically designed for use with “962” type drivers.
The IGD962 (available from MPD) is a hybrid
integrated circuit specifically designed to drive
N-channel IGBT modules. It provides the I/O
isolation, high speed, drive voltage stability and
fault protection required to control most MOS
gated power devices.
The drawing at right illustrates a typical connection of the MHI205D-1509DI5.7 to the IGD962.
For more information on this connection, please
contact the factory.
Mechanical Dimensions
Pin Connections
Pin
1
2
5
6
7
Single Output
+VIN
-VIN
-VOUT
No Pin
+VOUT
Pin
1
2
5
6
7
Dual Output
+VIN
-VIN
-VOUT
Common
+VOUT
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages