MPD ML105S03 Ml100s sery Datasheet

ML100S Series
Ultra-Miniature, 1W
Single Output SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 1W Output Power
• Ultra-Miniature SMT Case
• 1,500 VDC Isolation
• 5V, 12, 15 & 24V Inputs
• -40ºC to +85ºC Operation
• 17 Standard Models
• 2.0 MH MTBF Minimum
• Available on Tape/Reel
Parameter
Conditions
5 VDC Input
12 VDC Input
15 VDC Input
24 VDC Input
Input Voltage Range
Reverse Polarity Input Current
Input Filter
Min.
4.5
10.8
13.5
21.6
Typ.
5.0
12.0
15.0
24.0
Max.
5.5
13.2
16.5
26.4
0.3
Units
Max.
±1.5
Units
%
%
120
150
15
±0.02
mV P - P
mV P - P
mv rms
%/ºC
Typ.
Max.
50
40
100
100
140
Units
VDC
M
pF
kHz
Min.
-40
Typ.
+25
Max.
+85
+90
+125
Units
ºC
ºC
ºC
95
%
VDC
A
Capacitor
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Typ.
±5.0
For Vin Change of 1%
±1.2
See Model Selection Guide
See Note 2
60
Over Line, Load & Temp.
±0.01
Momentary (0.5 Sec.)
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
-50
Free Air Convection
RH, Non-condensing
0.54 x 0.43 x 0.27 Inches (13.7 x 11.0 x 7.0 mm)
Molding (UL94-V0)
0.06 Oz (1.7g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
2.0
Typ.
Max.
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
20.0
30.0
260
450
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
15 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec.
All Models
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
ºC
mW
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
ML105S-03
ML105S-05
ML105S-09
ML105S-12
ML105S-15
ML112S-03
ML112S-05
ML112S-09
ML112S-12
ML112S-15
ML115S-12
ML115S-15
ML124S-03
ML124S-05
ML124S-09
ML124S-12
ML124S-15
Output
Load
Rating
ciency Capacitive Fuse
Regulation Effi
Slow-Blow
(%, Typ)
Load
(%, Max)
(mA)
Output
Voltage (VDC)
Current (mA)
Voltage
Nominal
Range
Full-Load No-Load (VDC)
5
4.5 - 5.5
271
30
3.3
5
4.5 - 5.5
256
30
5.0
5
4.5 - 5.5
254
30
9.0
5
4.5 - 5.5
259
30
12.0
5
4.5 - 5.5
254
30
15.0
12
10.8 - 13.2
112
15
3.3
12
10.8 - 13.2
109
15
5.0
12
10.8 - 13.2
106
15
9.0
12
10.8 - 13.2
106
15
12.0
12
10.8 - 13.2
105
15
15.0
15
13.5 - 16.5
86
14
12.0
15
13.5 - 16.5
86
14
15.0
24
21.6 - 26.4
58
8
3.3
24
21.6 - 26.4
54
8
5.0
24
21.6 - 26.4
54
8
9.0
24
21.6 - 26.4
55
8
12.0
24
21.6 - 26.4
53
8
15.0
Current
Current
(mA, Max)
(mA, Min)
300
200
110
84
67
300
200
110
84
67
84
67
300
200
110
84
67
(µF, Max)
6.0
4.0
2.0
1.5
1.0
6.0
4.0
2.0
1.5
1.0
1.5
1.0
6.0
4.0
2.0
1.5
1.0
10
10
10
8
7
8
8
8
5
5
5
5
8
8
8
5
5
73
78
78
78
79
74
76
78
79
80
78
78
72
78
77
77
79
500
500
500
500
500
200
200
200
200
200
150
150
100
100
100
100
100
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
Derating Curve
Notes:
1. Load regulation is measured for an output change of 20% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin. For noise sensitive
applications, the use of 3.3 µF capacitors will reduce the output ripple.
3. Operation at no-load will not damage these units. However, they may not meet all
specifications.
4. The converter should be connected to a low ac-impedance source. An input source
with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over
long lines, it may be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor
be mounted close to the converter. For 5V input units a 2.2 µF is recommended; a
1.0 µF for 12V & 15V input units; and for 24V input models, a 0.47 µF.
5. It is recommended that a fuse be used on the input of a power supply for protection.
See the table above for the correct rating.
Mechanical Dimensions
Board Layout
Pin Connections
Pin
Description
1
-Vin
2
+Vin
3
No Pin
4
-Vout
5
+Vout
6
No Pin
7
No Pin
8
NA
NA = Not for electrical connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation
on the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]