ETC2 MRF-220 Roof mount ventilating Datasheet

15.75
(400)
2.78
(70.5)
13.78
(350)
11.42
7.00 (290)
(178)
2.5
0.68
(17.3)
7.00
(178)
11.02
(280)
0.58
(14.8)
STATIC PRESSURE - (IN. OF WATER)
ROOF MOUNT VENTILATING
MRF-220
2.0
1.5
1.0
0.5
°
45
23.5°
7.09
(180)
0
100
200
300
400
500
AIR FLOW (CFM)
Ø265
N 8 x Ø6
7.09
(180)
(400 x 350 x 116 mm)
15.75 x 13.78 x 4.57 inches
Construction:
Frame: magnesium - RAL7035
Fan: magnesium impeller &
frame
Model No.
Bearing option: ball bearing
Connection:
terminal block
Protection:
thermal
Options:
tachometer output signal,
thermistor speed control
w w w.mechatronic s.com
06.09.15
E - mail: S ales @ M echatronic s.com
MRF-220
Sound
Noise
Weight
INCH
dbA
kg
64.00
2.52
79
4
64.00
2.52
79
4
Rated
Voltage
Input
Power
Speed
V
W
RPM
M³/Min.
CFM
MM
115
102
2,800
11.3
435
230
102
2,800
11.3
435
Fa x : 425 -2 2 2- 515 5
Air Volume
Tel: 425 -2 2 2- 5 9 0 0
800-453-4569
Max. Static
Pressure (H2 0)
Cooling Simplified