ETC2 H2A-HR Id tools and machine Datasheet

APPLICATION TOOLING
5-B
ID tools and machines
ID tools and machines
The arrow mark indocates the press that is applicable to the applicator.
ID applicator
ID applicator
ID applicator
for discrete wires and jumper wires
for 1.27mm(.050") pitch ribbon cables
for discrete wires and jumper wires
ID applicator
for 1.27mm(.050") pitch ribbon cables
H2 series
HID series
H2A series
FP series
Hand press
Pneumatic press
Pneumatic press
Pneumatic press
AP-2H
AP-2
AP-2D
Auto. ID machines for discrete wires
BCD-M5BP
Auto. ID machines for shielded wires
SCD-M15B
HPD-M2A
HPD-M2A-HID
ID applicator
for discrete wires
MKD-LP
Versatile press applicable
to various ID applicators.
Specifications
Specifications
• Dimensions: (W x L x H)130 x 280 x 383mm
(5.1" x 11.0" x 15.1")
• Weight: Approx. 7kg(15 lb)
Note: The difference between the HPD-M2A and
the HPD-M2A-HID is the main shaft.
HPD-M2A is for the H2A series applicators
HPD-M2A-HID is for the HID series
applicators
Auto. ID machines for 2.5 mm (.098")
& 2.0 mm (.079") pitch jumper wires
• Dimensions: (W x L x H)
184 x 302 x 491mm
(7.2" x 11.9" x 19.3")
• Weight: Approx. 30kg(66 lb)
• Air pressure : 490 to 690 kPa (5 to 7 kgf/sq.cm)
• Strokes: 50 max./minute
• Pressure output: Approx. 7.5kN (Approx. 760 kgf)when
air pressure is 490 kPa (5 kgf/sq.cm)
• Operation method: Air-operated foot valve
• Dies: Applicator replacement
Versatile press applicable to
various ID applicators.
Specifications
Specifications
• Dimensions: (W x L x H)141 x 252 x 301mm
(5.6" x 9.9" x 11.9")
• Weight: Approx. 16kg(35lb)
• Air pressure: 490 to 690 kPa (5 to 7 kgf/sq.cm)
• Strokes: 50 max./minute
• Pressure output: Approx. 3.8kN (390 kgf)
when air pressure is 490 kPa (5 kgf/sq.cm)
• Operation method: Air-operated foot valve
• Dies: Applicator replacement
• Dimensions: (W x L x H)141 x 252 x 301mm
(5.6" x 9.9" x 11.9")
• Weight: Approx. 16kg(35lb)
• Air pressure: 490 to 686 kPa (5 to 7 kgf/sq.cm)
• Strokes: 50 max./minute
• Applicable connectors: JST's RA, RC & RX connectors
• Pressure output: Approx. 3.8kN (Approx. 390 kgf)
when air pressure is 490 kPa (5 kgf/sq.cm)
• Operation method: Air-operated foot valve
• Dies: Applicator replacement
Note: For the HR connectors, please use AP-2H
press that provides bigger pressure output.
RCD-M9BE
Pneumatic press for
1.27mm(.050") ribbon cable
connectors. Operation is
easy and safe as the
connector and cable can be
set while the sliding
applicator is drawn out of
the terminating section.
Pneumatic press
Pneumatic press
Optional: Control unit for pneumatic presses
MKD-LP+AP-K2N
MP-2A
MP-CU
Pistol tool
for discrete wires and jumper wires
IDB-12
<Made in
Germany>
The filter regulator & pressure switch help to make reliable operation even
under the air condition is not stable. Light and compact.
Specifications
Auto. ID machines for multi-harnesses
• Dimensions: (W x L x H)200 x 300 x 230mm(7.9" x 11.8" x 9.1")
• Weight: Approx. 5kg(11 lb)
• Power source: 100/115/220/240V AC, single-phase, 50/60 Hz
• Air pressure: 490 to 686 kPa (5 to 7 kgf/sq.cm)
• Accessories: Foot switch, power cord
CAM-M12B
Note: MKD-LP applicators are not applicable
to the connectors with glass-filled nylon
housings i.e. 12 to 15-circuit DD/DS
connectors and 13 to 16-circuit KR
connectors.
Specifications
948
• Dimensions: (WXLXH)95X515X203mm
(3.7"X20.3"X8.0")
• Weight: Approx. 6.5kg(14lb)
• Applicable press: AP-K2N
• Applicable connectors: JST'S connectors
for discrete wires.
Simple and compact pneumatic press without
electrically controlled unit.
Specifications
• Dimensions: (W x L x H)23 x 135 x 175mm
(.9" x 5.3" x 6.9")
• Weight: 270g(1lb)
• Dies: Head adaptor (IDH series)
replacement
• Compact, light and maintenance free. No
inspection or lubrication is necessary.
Specifications
• Dimensions: (WXLXH)180X150X250mm
(7.1"X5.9"X9.8")
• Weight: Approx. 10kg(22lb)
• Air pressure: 490 to 690kPa (5 to 7kgf/sq.cm)
• Dies: Dies-Main body integrated
• Strokes: 50 max./minute
949
ID TOOLS
ID TOOLS
5-B
Hand press: HPD-M2A
Pneumatic press: AP-2 or AP-2H
Applicator
H2A series
Hand press: HPD-M2A
Hand press: HPD-M2A-HID
Applicator
Applicator
H2 series
HID series
Pneumatic press: AP-2H
Electric press: AP-K2N
Pitch-feeding applicator
MKD-LP with die set
Pneumatic press: AP-2H
Electric press: AP-K2N
Applicator
MKD-LR with die set
Pneumatic press: AP-2D
Applicator
FP series
Pistol tool: IDB-12
Head adaptor
IDH series
Connector
Pitch mm(in.)
Series
0.8(.031)
SUR
1.5(.059)
–
–
–
–
–
SUR
H2A-SR
H2-SR20ED-X
–
–
–
–
–
SR
SSR
H2A-SSR
H2-SSR20ED-X
–
–
–
–
–
SSR
ASR
H2A-ASR
H2-ASR20ED-X
–
–
–
–
–
ASR
CZ
H2A-CZ
H2-CZ20ED-X
–
–
–
–
–
CZ
ZR
H2A-ZR
H2-ZR20ED-X
–
MKD-LP + MKD-DS-ZR
–
–
ZA
H2A-ZA
H2-ZA20ED-X
–
MKD-LP + MKD-DS-ZA
–
–
H2A-KR/XR
H2-KR/XR20ED-X
–
MKD-LP + MKD-DS-KR (Note 1)
MKD - LR + MKD-LR-DS-KR
–
H2A-KRD
H2-KRD20DD-Y
–
–
–
–
–
KRD
H2A-KR/XR
H2-KR/XR20ED-X
–
–
–
–
–
CK(Note4)
CR
H2A-CR
H2-CR20ED-X
–
–
–
–
–
CR
DR
H2A-DR
H2-DR20ED-X
–
MKD-LP + MKD-DS-DR
–
–
IDH-DR12
DR
DA
H2A-DA
H2-DA20ED-X
–
MKD-LP + MKD-DS-DA
MKD - LR + MKD-LR-DS-DA
–
IDH-DA12
DA
H2A-DD/DS
H2-DD/DS20ED-X
–
MKD-LP + MKD-DS-DD/DS
(Note 1)
–
–
IDH-DD/DS12
H2A-NR
H2-NR20ED-X
–
MKD-LP + MKD-DS-NR
–
–
IDH-NR12
KRD
CK (Note 4)
DD
DS
NR
2.54(.100)
3.96(.156)
IDH-ZR12
–
IDH-KR12
ZR
DS
NR
H2-NRD20DD-Y
–
MKD-LP + MKD-DS-NRD (Note 2)
–
–
H2-HR20ED-X
–
MKD-LP + MKD-DS-HR
MKD - LR + MKD-LR-DS-HR
–
IDH-HR12
DB
H2A-DB
H2-DB20ED-X
–
MKD-LP + MKD-DS-DB/DC
MKD - LR + MKD-LR-DS-DB
–
IDH-DB/DC12
DB
DG
H2A-DG
–
MKD-LP + MKD-DS-DG
–
–
–
DG
BR
H2A-BR
–
MKD-LP + MKD-DS-BR
BR
–
NRD
HR
–
–
–
RA
–
–
HID-RA/RX
–
–
FCD-DS FP2-RA/RX
–
RA
RC
–
–
HID-RC
–
–
FCD-DS FP2-RC
–
RC
RX
–
–
HID-RA/RX
–
–
FCD-DS FP2-RA/RX
–
RX
–
–
–
–
VR
Ribbon cable cutter
H2A-VR
–
H2-VR15DD-Y
–
–
HID-FC
MKD-LP + MKD-DS-VR (Note 2)
–
2.0(.079)
DD
H2A-HR
H2-BR20ED-X
1.5(.059)
KR(Note3)
H2A-NRD
–
1.0(.039)
ZA
HR
NRD
2.5(.098)
0.8(.031)
H2-SUR30ED-X
KR (Note 3)
2.0(.079)
Pitch mm(in.)
H2A-SUR
SR
1.0(.039)
Connector
Series
IDH-VR12
–
2.5(.098)
2.54(.100)
3.96(.156)
VR
Ribbon cable cutter
Note 1: MKD-LP applicators are not applicable to the connectors with glassfilled nylon housings i.e. 12 to 15-circuit DD/DS connectors and 13 to
16-circuit KR connectors.
Note 2: End-connection only (not through processing)
Note 3: ID tools for the standard KR series connectors are not applicable to
the ( )KR-4K-** connectors. For ( )KR-4K-**, use the tools for the CR
series connectors.
Note 4: ID tools for the standard CK series connectors are not applicable to the
( )CK-6H-** connectors. For ( )CK-6H-**, use the tools for the KR/XR
series connectors.
950
951
Similar pages