ETC2 LRD332 Tesysâ® iec contactors and starter Datasheet

Table of Contents
Section 18
TeSys® IEC Contactors and Starters
New!
Contactors
TeSys D
18-4
TeSys D Reversing
18-6
TeSys F
18-5
TeSys K
18-24
TeSys D and F Accessories
TeSys D Contactors (p. 18-4)
TeSys K Accessories
18-8
18-27
18-28
GV2, GV3, GV7 Manual Motor Protectors
18-33
Enclosed D-Line
18-21
GV Accessories
18-34
LS1D Fuse Block
18-36
TeSys F Contactors (p. 18-5)
Overload Relays
TeSys D
TeSys F
GV7 Manual Motor Starters
and Protectors (p. 18-35)
18-4
18-5
TeSys D and F Accessories
18-16
TeSys K
18-24
TeSys K Accessories
18-27
TeSys T
16-92
Soft Start Module ATS01
18-32
Replacement Parts
TeSys D Coils
18-17
TeSys F Coils
18-20
TeSys F Contact Tips, etc.
18-13
Wiring Systems
GV3P (p.18-33)
LUB•2 (p. 18-28)
GV-Line Bus Bars
18-37
TeSys D Quickfit
18-38
AK5
18-39
Dimensions
18-40
GV2P21 (p.18-33)
For more information on lighting, definite purpose (DP), and elevator ratings for TeSys D
and TeSys F contactors, please refer to catalog 8502CT9901.
For more information on machine safety applications using TeSys D and TeSys F,
please refer to catalog MKTED208051EN-US.
See our website, www.schneider-electric.us, for UL 508A short circuit ratings (SCCR).
© 2009 Schneider Electric
All Rights Reserved
18-1
18
TeSys U
IEC CONTACTORS AND
STARTERS
Motor Starters and Protectors
TeSys® D AC and DC Contactors
3 Pole Contactors
Refer to Catalog 8502CT9901
www.schneider-electric.us
LC
D
_____
Full Voltage, Non-Reversing
1
Full Voltage, Reversing
2
_____
_____
_____
_____
TeSys D 3 Pole Contactors 9A to 150A
Contactor AC-3 Full Load Amps (FLA)
18
9A FLA
12A FLA
18A FLA
25A FLA
32A FLA
38A FLA (not marketed in US)
40A FLA
50A FLA
65A FLA
80A FLA
95A FLA (not marketed in US)
115A FLA
150A FLA
09
12
18
25
32
38
40
50
65
80
95
115
150
Everlink Power Connection (40A to 65A only)
A
IEC CONTACTORS AND
STARTERS
No Everlink Power Connection (9A to 32A, 80A to 150A)
Blank
Termination Options (choose one)
Screw Termination
Spring Terminations s
Ring Tongue Terminations t
Slip-on Terminations (9A to 12A only)
Blank
3
6
9
Coil Voltage (choose one)
AC Coils (50/60 Hz)
DC Coils (standard)
12V
21V
24V
36V
42V
48V
60V
100V
110V
115V
120V
127V
200V
208V
220V
230V
240V
277V
380V
400V
415V
440V
480V
500V
575V
600V
12V
21V
24V
36V
48V
60V
72V
110V
125V
220V
250V
440V
660V
s
t
J7
Z7
B7
C7
D7
E7
EE7
K7
F7
FE7
G7
FC7
L7
LE7
M7
P7
U7
W7
Q7
V7
N7
R7
T7
S7
SC7
X7
Y5
(50 Hz only)
JD
ZD
BD
CD
ED
ND
SD
FD
GD
MD
UD
RD
DC Coils
low consumption available
for 9 to 38 amp only
5V
AL
12V
JL
21V
ZL
24V
BL
48V
EL
72V
SL
96V
DL
110V
FL
220V
ML
250V
UL
On LC1D09 - LC1D65A, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. LC1D12G7 becomes
LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7 - Note that 40A to 65A spring terminals are only on the control terminations and not on power
terminations). No price adder for this modification.
On LC1D09 - LC1D65A and LC1DT20 through LC1DT80A, for ring tongue versions add '6' to the catalog number prior to adding the voltage code
(ex. LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). No price adder for this modification.
Note: To be used for interpretation of current catalog numbers only.
18-2
© 2009 Schneider Electric
All Rights Reserved
TeSys® F AC and DC Contactors
2, 3, and 4 Pole
Contactors
Refer to Catalog 8502CT9901
www.schneider-electric.us
LC
F
_____
Full Voltage, Non-Reversing
1
Full Voltage, Reversing
2
_____
_____
_____
_____
TeSys F 2, 3, and 4 Pole Contactors 115A to 800A
Contactor AC-3 Full Load Amps (FLA)
115A FLA
150A FLA
185A FLA
225A FLA
265A FLA
330A FLA
400A FLA
500A FLA
630A FLA
780A FLA
800A FLA
115
150
185
225
265
330
400
500
630
780
800
Number of Poles
2 Poles (400A, 500A, and 630A only)
4 Poles (all sizes except 800A)
4
Termination Options - Purchase Lugs Separately
Blank
Coil Voltage (choose one and note contactor size it can be used on)
AC Coils
24V (50 Hz)
24V (60 Hz)
24V (40-400 Hz)
42V (50 Hz)
48V (50 Hz)
48V (60 Hz)
48V (40-400 Hz)
110V (50 Hz)
110V (60 Hz)
110V (40-400 Hz)
115V (50 Hz)
115V (40-400 Hz)
120V (60 Hz)
120V (40-400 Hz)
120V (40-400 Hz)
127V (60 Hz)
127V (40-400 Hz)
200/208V (60 Hz)
200/208V (40-400 Hz)
208V (40-400 Hz)
220V (50 Hz)
220V (60 Hz)
220V (40-400 Hz)
230V (50 Hz)
230V (40-400 Hz)
240V (50 Hz)
240V (60 Hz)
240V (40-400 Hz)
277V (50 Hz)
277V (40-400 Hz)
380V (50 Hz)
380V (60 Hz)
380V (40-400 Hz)
400V (50 Hz)
400V (40-400 Hz)
415V (50 Hz)
415V (40-400 Hz)
440V (50 Hz)
440V (40-400 Hz)
460/480V (60 Hz)
480V (40-400 Hz)
500V (50 Hz)
500V (40-400 Hz)
600V (40-400 Hz)
660V (60 Hz)
© 2009 Schneider Electric
All Rights Reserved
For use on:
B5
B6
B7
D5
E5
E6
E7
F5
F6
B7
FE5
FE7
G6
G7
F7
G6
G7
L6
L7
L7
M5
M6
M7
P5
P7
U5
U6
U7
W5
W7
Q5
Q6
Q7
V5
V7
N5
N7
R5
R7
Q6
N7
S5
S7
X7
Y6
LC1F115 - F225
LC1F115 - F225
LC1F225 - F400
LC1F115 - F225
LC1F115 - F225
LC1F115 - F225
LC1F115 - F630
LC1F115 - F225
LC1F115 - F225
LC1F115 - F780
LC1F115 - F225
LC1F115 - F780
LC1F115 - F225
LC1F115 - F400
LC1F500 - F780
LC1F115 - F225
LC1F115 - F780
LC1F115 - F225
LC1F265 - F780
LC1F115 - F225
LC1F115 - F225
LC1F115 - F225
LC1F115 - F780
LC1F115 - F225
LC1F115 - F800
LC1F115 - F225
LC1F115 - F225
LC1F115 - F780
LC1F115 - F225
LC1F115 - F780
LC1F115 - F225
LC1F115 - F225
LC1F115 - F780
LC1F115 - F225
LC1F115 - F800
LC1F115 - F225
LC1F115 - F780
LC1F115 - F225
LC1F115 - F780
LC1F115 - F225
LC1F780
LC1F115 - F225
LC1F115 - F780
LC1F500 - F630
LC1F115 - F225
DC Coils
24V
48V
110V
110V
125V
220V
220/240V
250V
380/400V
440V
For use on:
BD
ED
FD
FW
GD
MD
MW
UD
QW
RD
LC1F115 - F400
LC1F115 - F630
LC1F115 - F780
LC1F800
LC1F115 - F780
LC1F265 - F780
LC1F800
LC1F115 - F780
LC1F800
LC1F115 - F780
18-3
18
Blank
IEC CONTACTORS AND
STARTERS
2
3 Poles (all sizes)
TeSys® D Non-reversing
Contactors &
Overload Relays
Refer to Catalog 8502CT9901
www.schneider-electric.us
Table 18.1:
3- or 4-Pole Screw Terminal Connections
Maximum Current
Utilization
Categories
Maximum Horsepower Ratings
18
LC1D093
IEC CONTACTORS AND
STARTERS
LC1D40A
Table 18.2:
LRD22
LRD3
E164862
CCN NLDX
LR43364
Class 3211 04
18-4
Three Phase
TeSys D Overload Relays — Ambient Compensated, Bi-Metallic Direct Mount
Class 10 with
Class 10 without
Single Phase
Single Phase
Sensitivity
Sensitivity
0.10–0.16
LRD01
LR3D01
0.16–0.25
LRD02
LR3D02
0.25–0.40
LRD03
LR3D03
0.40–0.63
LRD04
LR3D04
0.63–1
D09–D32
LRD05
LR3D05
1–1.6
LRD06
LR3D06
1.6–2.5
LRD07
LR3D07
2.5–4
LRD08
LR3D08
4–6
LRD10
LR3D10
5.5–8
D09–D32
LRD12
LR3D12
7–10
D09–D32
LRD14
LR3D14
9–13
D12–D32
LRD16
LR3D16
12–18
D18–D32
LRD21
LR3D21
16–24
D25–D32
LRD22
LR3D22
17–25
D25–D32
—
—
23–32
D25–D32
LRD32
LR3D32
23–28
D25–D32
—
—
25–32
D25–D32
—
—
30–38
D32
LRD35
LR3D35
9-13
D40A-D65A f
LRD313
LR3D313
12-18
D40A-D65A f
LRD318
LR3D318
16-25
D40A-D65A f
LRD325
LR3D325
23-32
D40A-D65A f
LRD332
LR3D332
30-40
D40A-D65A f
LRD340
LR3D340
37-50
D40A-D65A f
LRD350
LR3D350
48-65
D40A-D65A f
LRD365
LR3D365
17-25
D40-D80 g
LRD3322
LR3D3322
23-32
D40-D80 g
LRD3353
LR3D3353
30-40
D40-D80 g
LRD3355
LR3D3355
37-50
D50-D80 g
LRD3357
LR3D3357
48-65
D50-D80 g
LRD3359
LR3D3359
55–70
D65–D80
LRD3361
LR3D3361
63–80
D65–D80
LRD3363
LR3D3363
80–104
D80
LRD3365
—
80–104
D115–D150
LRD4365
—
95–120
D115–D150
LRD4367
—
110–140
D150
LRD4369
—
f
Overload relays with Everlink termination - direct mount to D40A to D65A only.
g
Direct mount to old D2 style D40 to D65 (no Everlink terminations) and to D80 only.
TeSys D contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
TeSys T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91
Current Setting
Range Amperes
LC1D115
Instantaneous
Auxiliary
Contacts
$ Price
Catalog
Number a
Inductive Resistive
AC3
AC1
N.O.
N.C.
N.O.
N.C.
115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp Amperes Amperes
AC Coils DC Coils
94.00
119.00
0.5
1
2
2
5
7.5
9
3
LC1D09 cde
0
—
—
—
—
—
—
—
4
LC1DT20 c
94.00
119.00
20
1
1
—
—
—
—
—
—
—
2
2
LC1D098 c
94.00
119.00
119.00
149.00
1
2
3
3
7.5
10
12
3
LC1D12 cde
0
—
—
—
—
—
—
—
4
LC1DT25 c
25
1
1
119.00
149.00
119.00
149.00
—
—
—
—
—
—
—
2
2
LC1D128 c
1
3
5
5
10
15
18
3
LC1D18 cd
136.00
160.00
0
32
1
1
—
—
—
—
—
—
—
4
LC1DT32 c
149.00
183.00
149.00
183.00
—
—
—
—
—
—
—
2
2
LC1D188 c
2
3
7.5
7.5
15
20
25
3
LC1D25 cd
151.00
181.00
0
40
1
1
—
—
—
—
—
—
—
4
LC1DT40 c
193.00
240.00
193.00
240.00
—
—
—
—
—
—
—
2
2
LC1D258 c
2
5
10
10
20
30
32
50
3
0
1
1
LC1D32 cd
172.00
213.00
3
5
10
10
30
30
40
3
1
1
LC1D40A
218.00
275.00
60
0
—
—
—
—
—
—
—
4
0
0
LC1DT60A
296.00
353.00
3
7.5
15
15
40
40
50
3
LC1D50A
234.00
291.00
0
1
1
5
10
20
20
40
50
65
80
3
LC1D65A
322.00
379.00
—
—
—
—
—
—
—
4
0
0
0
LC1DT80A
446.00
503.00
7.5
15
25
30
60
60
80
3
1
1
LC1D80
363.00
420.00
0
—
—
—
—
—
—
—
125
4
LC1D80004 b
489.00
524.00
0
0
489.00
524.00
—
—
—
—
—
—
—
2
2
LC1D80008 b
—
—
30
40
75
100
115
3
LC1D115
479.00
479.00
1
1
—
—
40
50
100
125
150
200
3
0
LC1D150
696.00
696.00
—
—
—
—
—
—
—
4
0
0
LC1D115004
630.00
630.00
a
Complete catalog number with coil voltage code from table on page 18-6; example, LC1D09G7.
b
For DC version of these devices replace the 'C' with 'P' (ex. LC1D80004** becomes LP1D80004**). This applies only to 80A 4 pole devices.
c
On LC1D09 - LC1D65A and LC1DT20 through LC1DT80A, for ring tongue versions add '6' to the catalog number prior to adding the voltage code
(ex. LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). No price adder for this modification.
d
On LC1D09 - LC1D65A, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. LC1D12G7 becomes
LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7 - Note that 40A to 65A spring terminals are only on the control terminations and not on power
terminations). No price adder for this modification.
e
On LC1D09 and LC1D12 only, for slip-on connector versions add "9" to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes
LC1D099G7). No price adder for this modification.
Single Phase
LC1D09
No of Poles
For Direct Mounting
to LC1
...
I12
Discount
Schedule
Class 20 with
Single Phase
Sensitivity
—
—
—
—
—
—
—
LRD1508
LRD1510
LRD1512
LRD1514
LRD1516
LRD1521
—
LRD1522
—
LRD1530
LRD1532
—
LRD313L
LRD318L
LRD325L
LRD332L
LRD340L
LRD350L
LRD365L
LR2D3522
LR2D3553
LR2D3555
LR2D3557
LR2D3559
LR2D3561
LR2D3563
—
—
—
—
Class 20 without
Single Phase
Sensitivity
—
—
—
—
—
—
—
LR3D1508A1
LR3D1510A1
LR3D1512A1
LR3D1514A1
LR3D1516A1
LR3D1521A1
—
LR3D1522A1
—
LR3D1530A1
LR3D1532A1
—
—
—
—
—
—
—
—
LR3D3522
LR3D3553
LR3D3555
LR3D3557
LR3D3559
LR3D3561
LR3D3563
—
—
—
—
$ Price
60.00
62.00
73.00
107.00
107.00
127.00
362.00
© 2009 Schneider Electric
All Rights Reserved
TeSys® F Non-reversing
Contactors &
Overload Relays
Refer to Catalog 8502CT9901
www.schneider-electric.us
TeSys D Overload Relays — Solid State
For Direct Mounting Beneath
Contractor LC1
D115–D150
D115–D150
Current Setting Range Amperes
60–100
90–150
200 V
208 V
220 V
240 V
460 V
480 V
HP
HP
HP
40
Table 18.5:
b
c
AC-3
HP
Catalog
Number a
Maximum Current
Number of
Poles
AC-1
A
$ Price
Panel Mount with Screws
d
A
115
200
TeSys F 3-Phase Overload Relays — Solid State Separate Mount b
For Direct Mounting to Contactor
LC1●●●●
Coil Voltage Codes h
Contactor
Hz
D09–D150
50/60
60
50
50
60
40–400
40–400
LC1D80–LC1D150 only
F115, F150, and F185
F265, and F330
F400— F780
e
f
g
h
i
100
Class 10 Trip c
Class 20 c
$ Price
Catalog Number
Catalog Number
30–50
F115–F185
LR9F5357
LR9F5557
298.00
48–80
F115–F185
LR9F5363
LR9F5563
298.00
60–100
F115–F185
LR9F5367
LR9F5567
298.00
90–150
F115–F185
LR9F5369
LR9F5569
298.00
132–220
F185 d –F265
LR9F5371
LR9F5571
298.00
200–330
F265–F500
LR9F7375b
LR9F7575b
333.00
300–500
F265–F500
LR9F7379b
LR9F7579b
737.00
380–630
F400–F630
LR9F7381b
LR9F7581b
905.00
When mounting overload relays LR9F5●57 to LR9F5●71 directly beneath the contactor, supporting the relays with a mounting plate is recommended.
With overload relays LR9F7●75 to LR9F7●81, use of a support mounting plate is mandatory.
IEC standard 60947-4 specifies the following trip times when the overload relay senses 7.2 times the setting current:
Class 10 — between 4 and 10 seconds
Class 20 — between 6 and 20 seconds
Interconnection kit LA7F407 is required to mount an LR9F●71 to an LC1F185.
Table 18.6:
© 2009 Schneider Electric
All Rights Reserved
575 V
600 V
75
Current Setting Range
Amps
LR43364
Class 3211 04
298.00
298.00
3
LC1F115
479.00
4
LC1F1154
630.00
3
LC1F150
696.00
40
50
100
125
150
250
4
LC1F1504
825.00
3
LC1F185
938.00
50
60
125
150
185
275
4
LC1F1854
1439.00
3
LC1F225
1059.00
Current Rated
225
315
4
LC1F2254
1935.00
3
LC1F265
1179.00
60
75
150
175
265
350
4
LC1F2654
1646.00
3
LC1F330
1621.00
75
100
200
250
330
400
4
LC1F3304
1846.00
2
LC1F4002
1521.00
100
125
250
300
400
500
3
LC1F400
1874.00
4
LC1F4004
2133.00
2
LC1F5002
4324.00
150
200
400
500
500
700
3
LC1F500
4970.00
4
LC1F5004
5617.00
2
LC1F6302
5917.00
250
300
600
800
630
1000
3
LC1F630
6474.00
4
LC1F6304
7582.00
3
LC1F780
7788.00
Current Rated
780
1600
4
LC1F7804
9940.00
—
450
800
900
800
1000
3
LC1F800
6676.00
a
Complete part number by adding coil voltage code from table below. For example: LC1F115G7. All contactors (except F780) include 1 N.O. coil
interlock contact.
30
E164862
CCN NLDX
$ Price
TeSys F 2-, 3-, and 4-Pole Contactors
Standard power ratings of 3-phase motors 50/60 Hz in
category AC-3
LC1F115
Class 20
LR9D5567
LR9D5569
24 V
B7
B6
B5
B5
B6
B7
—
48 V
E7
E6
E5
E5
E6
E7
E7
110 V
F7
F6
F5
F5
F6
F7
F7
120 V
AC
G7
G6
—
—
G6
G7
G7
DC
125 V
208 V
220 V
240 V
250 V
440 V
480 V
600 V
—
—
—
—
—
—
—
LE7
L6
—
—
L6
L7
L7
M7
M6
M5 e
M5
M6
M7
M7
U7
U6
U5
U5
U6
U7
U7
—
—
—
—
—
—
—
—
—
—
—
—
—
—
T7 e
T6
—
—
Q5
S7i
N7
X7 ef
X6 f
—
—
SC
X7
X7 g
—
—
—
—
—
—
—
—
D09-D32, DT20-D258
—
BL
EL
FL
—
—
—
ML
—
UL
—
Low Consumption
D09–D150
—
BD
ED
FD
—
GD
—
MD
—
UD
RD
F115-F330
—
BD
ED
FD
—
GD
—
MD
—
UD
RD
F400–F780
—
—
ED
FD
—
GD
—
MD
—
UD
RD
Not available for LC1D80 - LC1D150
Not available for LC1D115 or LC1D150
Not available for LC1F780. The 600 V coils for the LC1F400 - LC1F630 do not include an auxiliary contact for holding circuits.
For additional voltage codes refer to the IEC Contactor and Starter Catalog 8502CT9901.
For use with F265—F330 only.
Table 18.7:
Volts AC/DC
50/60 HZ
Coil Voltage Codes for AC and DC Voltages for F800 (includes built-in surge suppressor)
24
—
48
—
110
FW
120
FW
127
FW
208
—
220
MW
240
MW
277
—
380
QW
415
QW
440
QW
480
—
575
—
600
—
660
—
TeSys F contactor accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-11
TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-49
I12
Discount
Schedule
18-5
IEC CONTACTORS AND
STARTERS
Table 18.4:
Class 10
LR9D5367
LR9D5369
18
Table 18.3:
TeSys® D 3- and 4-Pole Reversing, AC or DC Operating Coil
Contactors
Refer to Catalog 8502CT9901
www.schneider-electric.us
Each 3-pole device is pre-wired with line and load side power wiring for reversing applications.
Each 4-pole device is pre-wired with load side power wiring
Table 18.8:
3-Pole & 4-Pole Mechanically Interlocked Contactors
Maximum Horsepower Ratings
Maximum Current
Built In Auxiliary
$ Price
No. of N.O.
Catalog
Contacts
Inductive
Resistive
Power
Number
(per contactor)
AC
DC
AC3
AC1
Poles
ab
Control Control
115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp Amperes
Amperes
N.O.
N.C.
0.5
1
2
2
5
7.5
9
3
1
1
LC2D09c
234.00 317.00
20
—
—
—
—
—
—
—
4
1
1
LC2DT20
234.00 317.00
1
2
3
3
7.5
10
12
3
1
1
LC2D12c
317.00 368.00
25
—
—
—
—
—
—
—
4
1
1
LC2DT25
317.00 368.00
1
3
5
5
10
15
18
35
3
1
1
LC2D18c
344.00 400.00
—
—
—
—
—
—
—
32
4
1
1
LC2DT32
419.00 443.00
2
3
7.5
7.5
15
20
25
3
1
1
LC2D25c
374.00 436.00
40
—
—
—
—
—
—
—
4
1
1
LC2DT40
456.00 477.00
2
5
10
10
20
30
32
50
3
1
1
LC2D32c
415.00 503.00
3
5
10
10
30
30
40
60
3
1
1
LC2D40A
565.00 650.00
3
7.5
15
15
40
40
50
70
3
1
1
LC2D50A
596.00 680.00
5
10
20
20
50
50
65
80
3
1
1
LC2D65A
778.00 857.00
7.5
15
30
30
60
60
80
3
1
1
d
—
125
—
—
—
—
—
—
—
4
—
—
d
—
—
—
30
40
75
100
115
3
1
1
LC2D115 e 1165.00 1165.00
200
—
—
—
—
—
—
—
4
—
— LC2D115004 e 1391.00 1391.00
—
—
40
50
100
125
150
200
3
1
1
LC2D150e 1598.00 1598.00
a
Use voltage codes from the “Voltage Codes” table below to complete the catalog number. For example: LC2D09G7
b
Includes mechanical interlock without electrical contacts. Installer to complete wiring for electronically interlocking contactor operating coils by utilizing
a N.C. auxiliary contact integrated in the contactor or optional LADN or LAD8N auxiliary contact block.
c
For LC2D09–LC2D32, electrical interlock can be included by adding a ”V” to the end of the catalog number (ex: LC2DO9B7V). List price adder: $5.00.
d
For these items, order two non-reversing contactors and one mechanical interlock separately. See page 18-4 and 18-14 for selection.
e
Includes mechanical interlock (Type LA9D11502) with pre-wired electrical contacts for interlocking contactor operating coils.
Single Phase
LC2D09
18
IEC CONTACTORS AND
STARTERS
Table 18.9:
Three Phase
Coil Voltage Codes i
Contactor
Hz
D09–D150
50/60
50
60
50 Hz
F115, F150, F185
60 Hz
F265, F330
40–400 Hz
F400–F780
40–400 Hz
LC1D80–LC1D150
24 V
B7
B5
B6
B5
B6
B7
—
48 V
E7
E5
E6
E5
E6
E7
E7
110 V
120 V
125 V
208 V
220 V
240 V
250 V
440 V
480 V
600 V
G7
—
G6
—
G6
G7
F7
AC
—
—
—
—
—
—
—
DC
LE7
—
L6
—
L6
L7
L7
M7
M5 f
M6
M5
M6
M7
M7
U7
U5
U6
U5
U6
U7
U7
—
—
—
—
—
—
—
—
—
—
—
—
—
—
T7 f
—
T6
—
Q5
S7 j
N7
X7 f
—
X6 gf
—
SC
X7
X7 h
—
—
—
—
—
—
—
—
F7
F5
F6
F5
F6
F7
F7
D09-D32,
DT20-D258
—
BL
EL
FL
—
—
—
ML
—
UL
—
Low Consumption
D09–D150
—
BD
ED
FD
—
GD
—
MD
—
UD
RD
F115–F330
—
BD
ED
FD
—
GD
—
MD
—
UD
RD
F400–F780
—
—
ED
FD
—
GD
—
MD
—
UD
RD
f
Not available for LC1D80 - LC1D150.
g
Not available for LC1D115 or LC1D150.
h
Not available for LC1F780. The 600 V coils for the LC1F400 - LC1F630 do not include an auxiliary contact for holding circuits.
i
For additional voltage codes refer to the IEC Contactor and Starter Catalog 8502CT9901.
j
For use with F265—F330 only.
Table 18.10:
Volts AC/DC
50/60 Hz
Coil Voltage Codes for AC and DC Coil Voltages for F800 (includes built-in surge suppressor)
24
—
48
—
110
FW
120
FW
127
FW
208
—
220
MW
240
MW
277
—
380
QW
415
QW
440
QW
480
—
575
—
600
—
660
—
TeSys D contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
E164862
CCN NLDX
LR43364
Class 3211 04
18-6
I12
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® F 3-Pole Reversing, AC or DC Operating Coil
Contactors
Refer to Catalog 8502CT9901
www.schneider-electric.us
HOW TO ORDER:
Components are available for customer assembly of TeSys F reversing contactors. For
example, the following components must be ordered to build a 75 hp @ 460 V reversing
contactor with a 120 V/60 Hz coil:
Table 18.11:
Catalog Number
LC1F115G6
DZ2FF1
LADN11
LA9FF976
LA9FF970
3-Pole Contactors
Maximum Horsepower Ratings
Three Phase
Maximum Current
Holding Circuit
Contact Built
Into Coil
Catalog
$ Price
Numbera
230 V
460 V
575 V
N.O.
N.C.
hp
hp
hp
40
75
100
115
200
1
0
LC1F115
479.00
50
100
125
150
250
1
0
LC1F150
696.00
60
125
150
185
275
1
0
LC1F185
938.00
75
150
200
265
350
1
0
LC1F265
1179.00
100
200
250
330
400
1
0
LC1F330
1621.00
125
250
300
400
500
1
0
LC1F400
1874.00
200
400
500
500
700
1
0
LC1F500
4970.00
300
600
800
630
1000
1
0
LC1F630
6872.00
Current rated
780
1600
0
0
LC1F780
7788.00
—
450
800
900
800
1000
0
0
LC1F800
6676.00
a
Use coil voltage codes from the “Voltage Codes” table on page 18-6 to complete the contactor catalog number.
Inductive
AC3
Amperes
200 V
hp
30
40
50
60
75
100
150
250
Table 18.13:
Resistive
AC1
Amperes
Auxiliary contact (electrical interlocking) - 2 must be purchased
For use with
Number of
Contacts
Maximum Number
of Blocks
Per Contactor
1
1
2
2
4
2
LC1F
to be ordered
separately
b
1
—
1
2
2
1
4
—
3
2
—
1
1
2
3
—
4
1
2b
Catalog Number
LADN10
LADN01
LADN11
LADN20
LADN22
LADN13
LADN40
LADN04
LADN31
LADC22
$ Price
13.10
13.10
20.70
20.70
41.50
41.50
41.50
41.50
41.50
41.50
including 1 N.O. + 1 N.C. make-before-break
Table 18.14:
Accessories—For the assembly of three-pole reversing contactors
(horizontal mounting)
With 2 Identical
Contactors c
c
Contact Arrangement
Set Of Power Connections
Catalog Number
LC1F115
LA9FF976
LC1F150
LA9F15076
LC1F185
LA9FG976
LC1F265
LA9FH976
LC1F330
LA9FJ976
LC1F400
LA9FJ976
LC1F500
LA9FK976
LC1F630, F800
LA9FL976
For two contactors of different size, refer to pages 18-15.
$ Price
106.00
96.00
113.00
151.00
225.00
198.00
306.00
568.00
Horizontal Mounting
Mechanical Interlock Kit
Catalog Number
LA9FF970
LA9FF970
LA9FG970
LA9FJ970
LA9FJ970
LA9FJ970
LA9FJ970
LA9FL970
$ Price
53.00
53.00
53.00
76.00
76.00
76.00
76.00
76.00
TeSys F contactor accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-11
TeSys F overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-42
E164862
CCN NLDX
LR43364
Class 3211 04
© 2009 Schneider Electric
All Rights Reserved
I12
Discount
Schedule
18-7
IEC CONTACTORS AND
STARTERS
Table 18.12:
Description
Contactors
Lugs (page 18-12)
Auxiliary contacts
Power connections
Mechanical interlock
18
LC1F265
Quantity
2
6
2
1
1
TeSys® D & F Auxiliary Contacts, Time Delay, Mechanical Latch
Contactor
Accessories
Refer to Catalog 8502CT9901
www.schneider-electric.us
Table 18.15:
Standard, instantaneous auxiliary contact blocks
Snap-On
Mounting
Composition
Number of
Contacts
To front of
LC● DT20–D258 (4P),
LC●D09–D150a
or
To right side of
LC ● F
4a
2
Front Mounted
Auxiliary Blocks
(shown on TeSys D
contactor)
18
a
b
c
d
IEC CONTACTORS AND
STARTERS
e
To front of
LC ●D80 and D115
or
To left side of
LC●F
1
To side of
LC●D09 to D150 only
(not for use on TeSys F)
2
0
1
Standard Contacts Dusttight Contacts
N.O.
To front of
—
LP● D40–D80, LC ● DT20–D258 (4P),
2
LC ● D09 to D80
1
or
To right side of
—
LC ●F
f
Device supplied with 4 ground terminal points.
Table 18.17:
$ Price
LADN22 b
LADN13 b
LADN40 b
LADN04 b
LADN31 b
LADC22 bc
LADN11 b
LADN20 b
LADN02b
41.50
41.50
41.50
41.50
41.50
41.50
20.70
20.70
20.70
LADN10 d
LADN01 d
13.10
13.10
N.C.
—
—
1
N.O.
2
2
2
N.C.
—
—
—
—
2
—
Catalog Number
$ Price
LA1DX20
LA1DZ40
LA1DZ31
65.00
82.00
82.00
LA1DY20f
77.00
Pneumatic time delay contact blocks
Time Delay
Contacts
Snap-On
Mounting
N.O.
Range of
Time Delay
Type
N.C.
Catalog
Number h
$ Price
0.1 to 3 sg
LADT0
131.00
0.1 to 30 s
LADT2
131.00
10 to 180 s
LADT4
131.00
1 to 30 si
LADS2
131.00
0.1 to 3 sg
LADR0
131.00
On de-energization 0.1 to 30 s
1
1
LADR2
131.00
(off-delay)
10 to 180 s
LADR4
131.00
Scale range is expanded between 0.1 and 0.6 seconds on the dial for more accurate settings at the lower end of
the range.
For spring terminal versions of these blocks, add a “3” to the end of the catalog number. (Ex. LADT23). No price
adder for this modification.
With switching time of 40 ms ± 15 ms between the opening of the N.C. contact to the closing of the N.O. contact.
To front of
LP● D40–D80,
LC● DT20–D258 (4P),
LC ● D09 to D150
or
To right side of
LC● F
i
1
0
Catalog Number a
Instantaneous blocks with dust-tight auxiliary contacts (IP54)
NEMA 12
Snap-On
Mounting
h
N.C.
2
3
0
4
1
2c
1
0
2
1
1
LAD8N11 e
20.70
2
0
LAD8N20 e
20.70
For low consumption coils (LC1D09 to D32 only), only one front-mounted two-contact block allowed. No sidemounted contact blocks allowed.
For spring terminal versions of these blocks, add a “3” to the end of the catalog number. (Ex. LADN223). No price
adder for this modification.
Including 1 N.O. + 1 N.C. make before break overlapping contacts.
This block cannot be added to the LC1D 09 to D32 contactors; a maximum of 2 blocks can be mounted on the
LC1D40A to LC1/LP1D80 contactors only.
1 block may be added to the left side of the LC1D 09 to D32, AC coils only; 1 block may be added to each side of
the LC1D 40A to D80 contactors, AC coils only. Cannot be installed on TeSys D contactors with DC coils.
Table 18.16:
g
N.O.
2
1
4
0
3
2c
1
2
0
Table 18.18:
1
On energization
(on delay)
1
Mechanical latch blocks with manual or electrical unlatch
(TeSys D only)
Front snap-on
mounting onto
Catalog number
to be completed
by the code corresponding
to the coil voltage
Application
$ Price
For silent operation and energy
LAD6K10jk
conservation
For
silent
operation
and
energy
LC1 D80 to D150 LP1 D80
LA6DK20jk
conservation
j
Does not include internal coil clearing contact.
k
Complete catalog number by adding coil voltage code. For example: LAD6K10F.
LC●D09 to D65A
Table 18.19:
77.00
77.00
Coil Voltage Codes for LA6DK mechanical latch blocks
Volts
12
24
32/36
42/48
60/72
100
110/
127
200/
208
220/
240
380/
415
440/
480
500/
600
AC or DC
J
B
C
E
EN
K
F
L
M
Q
R
S
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
E164862
CCN NLDX
LR43364
Class 3211 04
18-8
I12
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® D Coil Suppressors, Cabling Accessories
Contactor Accessories
Refer to Catalog 8502CT9901
www.schneider-electric.us
RC Coil Suppressor
•
•
Limitation of transient voltage to 300% of nominal voltage maximum
Oscillating frequency limited to 400 Hz maximum. Slight increase in drop-out time (1.2 to 2 times normal)
Table 18.20:
Resistor/capacitor circuit (RC) for reduction of “electrical noise” in AC contactor coils
Installed by
LA4DA1U
Mounting on
Operating voltage 50/60 Hz
24–28 V
50–127 V
110–240 V
24-48 V
LC1D40A to LC1D65A (3P), 50-127 V
LC1DT60A to LC1DT80A
110-240 V
(4P)
380-415 V
24–48 V
LC●D80 to D150 (3 or 4P) 50–127 V
LC●D80 to D115 (4P)
110–240 V
380–415 V
LC1D09 to LC1D32 (3P)
LC●DT20 to DT40 (4P),
Snapping into cavity on right side without toolsb
Snap-on mounting and connection without tools to the
contactor coil terminals
Screw connection to the contactor coil terminals
Catalog Number
LAD4RCE
LAD4RCG
LAD4RCU
LAD4RC3E
LAD4RC3G
LAD4RC3U
LAD4RC3N
LA4DA2E
LA4DA2G
LA4DA2U
LA4DA2N
$ Price
26.20
26.20
26.20
26.20
26.20
26.20
26.20
26.20
26.20
26.20
26.20
Varistor Coil Suppressor
Limitation of transient voltage value to 200% of nominal voltage maximum
Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times normal)
Table 18.21:
LA4DA2U
Varistor (peak limiting) for reduction of “electrical noise” in AC or DC contactor coils
Installed by
Mounting on
Operating voltage 50/60 Hz
24–48 V
50–127 V
Snapping into cavity on right side without toolsb
110–250 V
LC1D40A to LC1D65A (3P), 24-48 V
Snap-on mounting and connection without tools to the
LC1DT60A to LC1DT80A 50-127 V
contactor coil terminals
(4P)
110-250 V
24–48 Vac
LC
●D80 to D115 (3P or 4P)
Screw connection to the contactor coil terminals
50–127 Vac
LC●D12, D25 (4P)
110–250 Vac
24–48 Vdc
Screw connection to the contactor coil terminals
LC●D80 (3P or 4P)
50–127 Vdc
110–250 Vdc
a
For DC coils 3-pole contactors are fitted with built-in surge suppression as standard.
LC●D09 to D32a
TeSys D contactors
Catalog Number
LAD4VE
LAD4VG
LAD4VU
LAD4V3E
LAD4V3G
LAD4V3U
LA4DE2E
LA4DE2G
LA4DE2U
LA4DE3E
LA4DE3G
LA4DE3U
$ Price
26.20
26.20
26.20
26.20
26.20
26.20
26.20
26.20
26.20
26.20
26.20
26.20
IEC CONTACTORS AND
STARTERS
•
•
•
•
No overvoltage or oscillating frequency
Polarized component. Increased drop-out time (6 to 10 times normal)
Table 18.22:
Diode for reduction of “electrical noise” in DC contactor coils
Installed on the upper part by
Snap-on mounting and connection w/o tools to the contactor coil terminals
Clip-on front mounting
LA4DC3U
18
Diode Coil Suppressor
Screw connection of wire to the contactor coil terminals
Mounting on
LC●D09 - D32
LC●D40A to D65,
D65A to DT80A
D80 (3P)
D80 (4P)
Operating voltage DC
24–250 V
Catalog Number
LAD4DDL
$ Price
26.20
24–250 V
LAD4D3U
26.20
24–250 V
LA4DC3U
26.20
Bidirectional Diode Coil Suppressor
•
•
Protection provided by limiting the transient voltage to 2 Uc max.
Maximum reduction of transient voltage peaks
Table 18.23:
Bidirectional peak limiting diode
Installed by
Mounting on
Operating Voltage 50/60 Hz and DC Catalog Number
$ Price
24 (AC only)
LAD4TB
26.20
Snapping into cavity on right side of contactor b
72 (AC only)
LAD4TS
26.20
12 - 24 V
LAD4T3B
26.20
25 - 72 V
LAD4T3S
26.20
LC1D40A to LC1D65A (3P),
Clip-on front mounting and connection without tools
LC1DT60A to LC1DT80A
73 - 125 V
LAD4T3G
26.20
to the contactor coil terminals c
(4P)
126 - 250 V
LAD4T3U
26.20
251 - 440 V
LAD4T3R
26.20
24 (AC only)
LA4DB2B
56.00
72 (AC only)
LA4DB2S
26.20
Screw Mounting d
LC●D80
24 (DC only)
LA4DB3B
56.00
72 (DC only)
LA4DB3S
56.00
b
Installing suppressor into the cavity makes the electrical connection. Overall width of contactor remains the same.
c
For LC●D09 through LC●D65A with DC or low consumption DC coils, 3-pole contactors are fitted with built-in bidirectional diode suppression as
standard.
d
Mounting at the top of the contactor on coil terminals A1 and A2.
LC●D09 to LC●D32 (3P)c
DT20 to DT40 (4P)
Table 18.24:
Cabling Accessories
Usage
Mounting on
For adapting existing wiring to a new product or for use with
top mount accessory.
LC1D09 to D38
LC1DT20 to DT60
AC only
For adapting existing wiring to a new product or for use with LC1D40A to LC1D65A
top mount accessory
(with no coil suppressor)
LAD4BB• •
© 2009 Schneider Electric
All Rights Reserved
Operating voltage 50/60 Hz
Without coil suppression
24-48 V
With coil
suppression
50-127 V
(varistor)
110-250 V
—
Catalog Number
LAD4BB
LAD4BBVE
LAD4BBVG
LAD4BBVU
LAD4BB3
$ Price
23.00
23.00
23.00
23.00
26.20
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
I12
Discount
Schedule
18-9
TeSys® D Electronic Timers and Interface Modules
Contactor Accessories
Refer to Catalog 8502CT9901
www.schneider-electric.us
The following accessories require use of cabling accessories (LAD4BB●●) for proper mounting. See page 18-9 for
illustration.
Electronic Serial Timer Modules
These solid state modules delay the energizing and de-energizing of the contactor coil.
Table 18.25:
Operational Voltage a
Type
24–250 Vac
Catalog Number
$ Price
0.1–2 s
LA4DT0U
1.5–30 s
LA4DT2U
25–500 s
LA4DT4U
For 24 V operation, the contactor must be fitted with a 21 V coil: coil voltage code Z5 for 50 Hz; Z6 for 60 Hz; ZD for DC.
On-delay
a
Time Delay
100–250 Vac
LC1D09–D65A
82.
82.
82.
LC1D80–D150
Interface Modules b
These modules allow the contactor coils to be energized from low voltage and low current level signals. They come in
mechanical relay and solid state versions. The relay plus manual operation versions include a lever for manually
turning the contactor on and off. When a module receives a low level signal, it allows the separate sourced control
voltage to flow to the contactor coil. It saves space and wiring time compared to conventional interposing relays.
Table 18.26:
18
Operational Voltage
Interface Type
IEC CONTACTORS AND
STARTERS
LA4DFB
b
24–250 Vac
LC1D09–D150
Relay
LC1D09–D150
Relay Plus
LC1D09–D150
Manual Operation
LC1D09–D150
Solid State
LC1D09–D65
Adapter required for D09 - D65A, see table 18.24.
100–250 Vac
Input Voltage
Catalog Number
24 Vdc
48 Vdc
24 Vdc
48 Vdc
24 Vdc
LA4DFB
LA4DFE
LA4DLB
LA4DLE
LA4DWB
LC1D80–D115
$ Price
55.
55.
71.
71.
71.
Automatic-Manual-Stop Control Modules
These modules allow for local and/or remote operation of the contactor coil. Each module includes a lever to switch
from automatic to manual operation and a dial to turn the contactor on and off.
Table 18.27:
Operational Voltage
24–100 Vac
LC1D09–D150
Catalog Number
100–250 Vac
—
$ Price
LA4DMK
35.
Low Voltage Ride Through Module (meets SEMI F47 requirements)
By ensuring SEMI F47 compliance of AC powered IEC contactors and relays, the low voltage ride through modules can
be used to increase the voltage sag immunity of semiconductor processing equipment. These modules make it
possible for AC powered Telemecanique contactors and relays to exceed the requirements of SEMI F47, both in the
magnitude and duration of a voltage sag event—even with accessories such as auxiliary contact blocks and pneumatic
timers.
The low voltage ride through modules can be used with Telemecanique contactors from 9 A through 80 A, as well as
the CAD series of control relays
Table 18.28:
For use on:
Catalog Number
$ Price
Contactor
Relay
LC1D●●B7
CAD●●B7
LADLVRT24V c
124.
CAD●●G7
LADLVRT120V c
124.
LC1D●●G7
LC1D●●LE7
CAD●●LE7
LADLVRT208V c
124.
Top mount bracket (required when using above modules) D09 - D32
LAD4BB c
23.
Top mount bracket (required when using above modules) D40 - D65
LAD4BB3 c
23.
Fuse
LA9D941
120.
c
LAD4BB must be used when the low voltage ride through module is being used with contactors 32 A and less, and TeSys CAD Series of Control Relays.
The LAD4BB3 must be used with the D40 - D65A. See table 18.24 on page 18-10.
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
LADLVRT
LADLVRT
E1
E1
A1
E2
A1
E2
1.25
32
A2
A2
A1
1.85
47
A2
LAD4BB
Contactors 32 A and less
18-10
Contactors 40 A–80 A
I12
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® D and F Accessories
Contactor Accessories
Refer to Catalog 8502CT9901
www.schneider-electric.us
For Power Pole or Control Connection
For use with
contactors
LC1/LP1
Sold in
lots of
Catalog
Number
D09, D12
D09–D32
1
1
LAD92560
LA9D3260
8.70
12.00
D40A-D65A
1
LAD96560
10.00
D09–D32
D40A–D65A
D80
F115
F150, F185
F265, F330, F400
F500
F630, F800
D09–D32
D40A-D65A
D80
F115
F150, F185
F265, F330, F400
F500
F630, F800
DT20, DT25
D80
LP1D40–D80
D115, D150
D80
D115, D150
10
1
2
4
4
4
4
4
10
1
1
1
1
1
1
1
2
2
10
10
10
3
LA9D2561
LAD9P32
LA9D80961
LA9FF602
LA9FG602
LA9FH602
LA9FK602
LA9FL602
LAD9P3
LAD9P33
LA9D80962
LA9FF601
LA9FG601
LA9FH601
LA9FK601
LA9FL601
LA9D1263
LA9D80963
LA9D09966
LA9D11567
LA9D8067
GV7AC03
26.20
6.00
6.50
55.00
65.00
169.00
228.00
278.00
10.00
25.00
6.50
6.80
8.20
12.00
21.80
38.20
8.70
17.50
2.20
4.00
5.50
31.10
For use with
contactors
LC1/LP1
4-pole contactors
D80 - D115
D09-D65A, DT20-DT80A,
LADN, LADT, LADR
For holder LA9D92
Sold in
lots of
Catalog
Number
$ Price each
100
LA9D92
.06
4 poles
3 poles
Connectors for
larger cable sizes
LA9D1260
Everlink® terminal
block
#8 AWG (10 mm2)
#4 AWG (25 mm2)
3 poles
2 poles
Links
for the parallel
connection of
3 poles
(Wye-Delta
Shorting Strap)
LA9D2561
4 poles
Second coil connection
Control circuit take-off from main pole
Spreaders for increasing pole pitch to 45 mm
Table 18.30:
For Marking
Description
LA9D40961
Reference label holder snap-on 8 x 22 mm
Reference label holder snap-on 8 x 18 mm 3 poles
Sheet of 300 labels self adhesive 7 x 21 mm
Table 18.31:
Set of shims for mounting LAD8N and LA8DN
Retrofit plate for replacement of LC1D40-D65 with
LC1D40A-D65A
35 mm DIN Rail – 2 meters long
LAD90
.06
1
LA9D93
4.30
For use with
contactors
LC1/LP1
D80
Sold in
lots of
Catalog
Number
$ Price each
1
LA9D511
9.80
D40A-D65A
1
LAD7X3
25.00
LC1D09 to D80
10
AM1DP200
5.20
$ Price
3 poles
3 poles
4 poles
Catalog
Number
LA5D1158031
LA5D150803
LA5D115804
$ Price
3 poles
3 poles
4 poles
Catalog
Number
LA5D11550
LA5D15050
LA5D115450
Replacement contacts
For use with
contactors
LC1D115
LC1D150
LC1D115
LA9D6567
Three-pole
Four-pole
Table 18.33:
100
For Mounting
Description
Table 18.32:
$ Price each
239.00
239.00
318.00
Arc chambers
For use with
contactors
LC1D115
LC1D150
LC1D115
Three-pole
Four-pole
90.00
90.00
119.00
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7
TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20
LA9D511
© 2009 Schneider Electric
All Rights Reserved
I12
Discount
Schedule
IEC CONTACTORS AND
STARTERS
Description
18
Table 18.29:
18-11
TeSys® F Contactors
Contactor Accessories
Refer to Catalog 8502CT9901
www.schneider-electric.us
Table 18.34:
LA9D09981
Suppressor Blocks
Operating limit: up to 220 V, 50/60 Hz coils
Description
For Use
Catalog Number
With coils LX1FF, FG, FH, F115, F150, F185, F225, F265, F330
LA9F980
FK, FL, FX, F400, F500, F630, F780, LX9FF, FG, FH, F115, F150, F185, F225,
With coils LX1FJ,
LA9D09980
F265, F330
Mounting bracket (for 35 mm DIN rail or panel mounting) for suppressor block
LA9D09981
$ Price
21.80
Suppressor block
(clip-on mounting to coil)
Table 18.35:
LA9F980
20.70
5.50
Lugs and Lug Kits a
Kit Catalog Cable Size AWG
Contactor LugNumber
Type LC1 Contactor Only
range
Directly
mounted to
contactor
Overload Relay
Lugs Required
Cable size AWG range
Line side of
Load side of
contactor
overload
14 to 2/0
6 to 3/0
6 to 3/0
6 to 300 MCM
F115
F150, F185
DZ2FF6
DZ2FG6
—
14 to 2/0
6 to 3/0
LR9F5•57 to F5•69
LR9F5•57 to F5•71
LR9F5•71
F115
F150 to F185
F225, F265
Line side of
Load side of
contactor
overload
3 each DZ2FF1 3 each DZ2FG1
1 each DZ2FG6
1 each DZ2FH6
F225, F265,
F330
F400
F500
DZ2FH6
6 to 300 MCM
LR9F7•75 to F7•79
F265 or F330
3 each DZ2FH1
6 to 300 MCM
4 to 500 MCM
DZ2FJ6
DZ2FK6
4 to 500 MCM
2 x 2 to 600 MCM
LR9F7•75 to F7•81
LR9F7•75 to F7•81
F400
F500
4 to 500 MCM
2x2 to 600 MCM
4 to 500 MCM
4 to 500 MCM
F630, F800
DZ2FL6
3 x 2 to 600 MCM
LR9F7•81
F630
3 each DZ2FJ1
3 each DZ2FK1
1 each DZ2FL1
DZ2FL2
DZ2FL3
3x2 to 600 MCM
4 to 500 MCM
LC1•
18
1 each DZ2FR1
F780
DZ2FX6
4 x 1/0 to 750 MCM
—
—
—
—
a
Lug kits ending in the number “6” include 6 identical lugs. In some cases the LR9F overload relay mounted directly on the load side of an LC1F contactor
will require a different size lug for your choice of contactor and overload. If the two sizes are different, order 3 of each size lug. Mounting hardware (screws,
washers, and nuts) are provided with the contactors and overload relays, not with the lugs. See Table 18.37 for pricing.
IEC CONTACTORS AND
STARTERS
Table 18.36:
Lugs—2 and 4-Pole c
Contactor
Type LC1
b
c
Lug Kit
Catalog Number
Qty. Required
2-Pole
4
4
4
4
4
b
4
AL/CU
Cable Size
4-Pole
8
8
8
8
8
b
8
F115
DZ2FF1
14 to 2/0
F150, F185
DZ2FG1
6 to 3/0
F225, F265, F330
DZ2FH1
6 to 300 MCM
F400
DZ2FJ1
4 to 500 MCM
F500
DZ2FK1
2 X 2 to 600 MCM
F630
DZ2FLb
3 X 2 to 600 MCM
F780
DZ2FX1
4 X 1/0 to 750 MCM
For 2-pole F630 contactors, order 2 DZ2FL1 (L1 and T2), and 2 DZ2FL3 (L2 and T1).
For 4-pole F6304, order 2 DZ2FL1 (L1 and T4), 4 DZ2FL2 (L2, T2, L3, T3) and 2 DZ2FL3 (L4 and T1).
Lugs for LC1F contactors and overload relays must be ordered separately. Each kit consists of one (1) lug. Mounting hardware (screws, washers, nuts)
are provided with the contactors, not the lugs. See Table 18.37 for pricing.
Table 18.37:
Lugs Pricing
Lug Catalog Number
DZ2FF6
DZ2FG6
DZ2FH6
DZ2FJ6
DZ2FK6
DZ2FL6
DZ2FX6
DZ2FF1
DZ2FG1
$ Price
39.30
65.00
65.00
65.00
131.00
164.00
163.80
6.50
11.00
Lug Catalog Number
DZ2FH1
DZ2FJ1
DZ2FK1
DZ2FL1
DZ2FL2
DZ2FL3
DZ2FR1
DZ2FX1
$ Price
11.00
11.00
21.80
27.30
55.00
27.30
173.30
27.30
These clear plastic protective shrouds are an effective means to meet international touch-safe requirements for power
terminals. They are designed to be used with power cables that have been bolted to the terminal.
NOTE: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits.
Table 18.38:
Power Terminal Protection Shrouds
For Use With 2-, 3-, And 4-pole Contactors
LA9F70z
LC1F115
LC1F150, F185
LC1F225, F265, F330, F400 and F4002, F500 and F5002
LC1F630, F6302 and F800
LC1F1154
LC1F1504 and F1854
LC1F2254, F2654, F3304, F4004, F5004
LC1F6304
Number of Shrouds
Per Set
6
6
6
6
8
8
8
8
Catalog Number
$ Price
LA9F701
LA9F702
LA9F703
LA9F704
LA9F706
LA9F707
LA9F708
LA9F709
42.40
61.00
82.00
93.00
58.00
80.00
111.00
120.00
For contactors LC1F115, LC1F150, and LC1F185, an available touch-safe terminal block may be used in place of lugs
for power connections.
Table 18.39:
Insulated Terminal Blocks
For contactor
type LC1
F115, F150, F185
For overload
relay LR9
F5•57, F5•63, F5•67, F5•69
Maximum
Cable Size
300 MCM
Catalog Number
LA9F103
$ Price
55.00
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-5, 18-7
TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys F replacement coils and parts . . . . . . . . . .pages 18-18, 18-18, 18-20
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47
18-12
I12
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® F Contact Kits, Arc Chambers
Replacement Parts
Refer to Catalog 8502CT9901
www.schneider-electric.us
Replacement contact sets a
Catalog Number
LA5F400802
LA5F500802
LA5F630802
LA5FF431
LA5FG431
LA5FH431
LA5F400803
LA5F500803
LA5F630803
LA5F780801d
LA5F800803
LA5FF441
LA5FG441
LA5FH441
LA5F400804
LA5F500804
LA5F630804
LA5F780801d
$ Price
717.
1111.
1651.
239.
418.
793.
1076.
1589.
2488.
1651.
2488.
318.
549.
966.
1435.
2461.
3304.
1651.
For use on contactors
Catalog Number
LC1F4002
2 poles
LA5F400250
Two-pole
LC1F5002
2 poles
LA5F500250
LC1F6302
2 poles
LA5F630250
LC1F115
3 poles
LA5F11550
LC1F150
3 poles
LA5F15050
LC1F185
3 poles
LA5F18550
LC1F265
3 poles
LA5F26550
LC1F330
3 poles
LA5F33050
Three-pole
LC1F400
3 poles
LA5F40050
LC1F500
3 poles
LA5F50050
LC1F630
3 poles
LA5F63050
LC1F780
1 pole
LA5F780150d
LC1F800
3 poles
LA5F80050
LC1F1154
4 poles
LA5F115450
LC1F1504
4 poles
LA5F150450
LC1F1854
4 poles
LA5F185450
LC1F2654
4 poles
LA5F265450
Four-pole
LC1F3304
4 poles
LA5F330450
LC1F4004
4 poles
LA5F400450c
LC1F5004
4 poles
LA5F500450c
LC1F6304
4 poles
LA5F630450b
LC1F7804
1 pole
LA5F780150d
Supplied per pole are: 2 fixed contacts, 1 moving contact, 2 deflectors, 1 backplate, mounting screws and washers.
Comprises single-pole components.
Comprises 2-pole components.
2 identical components per pole are supplied.
$ Price
280.
305.
431.
90.
101.
179.
269.
287.
305.
341.
646.
431.
750.
119.
131.
248.
299.
414.
573.
610.
861.
431.
Two-pole
Three-pole
LA5FG431
Four-pole
LA5F11550
a
b
c
d
2 poles
2 poles
2 poles
3 poles
3 poles
3 poles
3 poles
3 poles
3 poles
1 pole
3 poles
4 poles
4 poles
4 poles
4 poles
4 poles
4 poles
1 pole
Arc chambers
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7
TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47
© 2009 Schneider Electric
All Rights Reserved
I12
Discount
Schedule
18-13
IEC CONTACTORS AND
STARTERS
Table 18.41:
For use on contactors
LC1F4002
LC1F5002
LC1F6302
LC1F115, F150
LC1F185
LC1F265
LC1F330, F400
LC1F500
LC1F630
LC1F780
LC1F800
LC1F1504, F1154
LC1F1854
LC1F2654
LC1F3304, F400, F4004
LC1F5004
LC1F6304
LC1F7804
18
Table 18.40:
TeSys® D Reversing Contactors
Contactors Accessories
Refer to Catalog 8502CT9901
www.schneider-electric.us
Table 18.42:
Contactors
Mechanical interlock
Reversing contactors comprising two identical,
horizontally mounted contactors:
Catalog
Number
LC1D09, LC1D12, LC1D18, LC1D25, LC1D32
LAD9R1e
$ Price
Set of power connections
With incorporated
electrical interlock
(2 N.C. contacts)
Without electrical
interlock
Catalog Number
32.10
Reversing contactors
for motor control
$ Price Catalog Number
LAD9R1Ve
45.50
LADT9R1e
36.90
LADT9R1Ve
45.50
e
Kit including mechanical interlock and wiring.
LC1D40, LC1D50, LC1D/LP1D65
LA9D50978
31.70
LAD4CM
45.00
$ Price Catalog Number
Included with kit
Not Available
Not Available
Included with kit
$ Price
18
LC1DT20, LC1DT25, LC1DT32, LC1DT40
Four pole
contactors
IEC CONTACTORS AND
STARTERS
LC1D40A, D50A, D65A
LA9D4002
45.90
Not Available
LA9D6569
53.00
LA9D65A69
75.00
LA9D6570
63.00
Not Available
LC1D80 AC coil
LA9D50978
31.70
LA9D4002
45.90
LA9D8069
65.00
LA9D8070
79.00
LC1D80 DC coil
LA9D80978
31.70
LA9D8002
65.00
LA9D8069
65.00
LA9D8070
79.00
LA9D11502
78.00
LA9D11569
129.00
LA9D11571
(3P)
LA9D11570
(4P) (D115 only)
53.00
LC1D115 and LC1D150
Not Available
53.00
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
18-14
I12
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® F Reversing Contactors
Contactors Accessories
Refer to Catalog 8502CT9901
www.schneider-electric.us
Component parts for the assembly of F-Line 3-pole reversing
contactors
Set of Power Connections
Catalog Number
Horizontal Mounting
LC1F115
LC1F150
LC1F185
LC1F265
LC1F330
LC1F400
LC1F500
LC1F630 or F800
Vertical Mounting
LC1F115 or F150
LC1F185
LC1F265
LC1F330
LC1F400
LC1F500
LC1F630 or F800
LC1F780
LA9F•970
LA9F•976
Table 18.44:
LA9F•977
Table 18.45:
LC1F185 or 1854
LC1F265 or 2654
LC1F330 or 3304
L2
L3
A1
A2
A1
1
3
5
1
3
5
2
4
6
2
4
6
U
V
A2
W
Reversing (motors) Application
1N
1L2
1L3
A1
A2
2L1
1L1
—
—
—
—
—
—
—
—
53.00
53.00
53.00
76.00
76.00
76.00
76.00
76.00
LA9FF4F
LA9FG4G
LA9FH4H
LA9FJ4J
LA9FJ4J
LA9FK4K
LA9FL4L
LA9FX970 b
97.00
113.00
126.00
149.00
149.00
149.00
149.00
508.00
Three-Pole
Four-Pole
LA9FF982
LA9F15082
LA9FG982
LA9FH982
LA9FJ982
LA9FJ982
LA9FK982
LA9FL982
LA9FF977
LA9F15077
LA9FG977
LA9FH977
LA9FJ977
LA9FJ977
LA9FK977
LA9FL977
d
d
d
d
d
d
d
b
d
d
d
d
d
d
d
c
$ Price
53.00
53.00
53.00
83.00
113.00
113.00
154.00
233.00
—
—
—
—
—
—
—
—
Mechanical
Interlock Kit
Catalog Number
LA9FF970
LA9FF970
LA9FG970
LA9FJ970
LA9FJ970
LA9FJ970
LA9FJ970
LA9FL970
LA9FF4F
LA9FG4G
LA9FH4H
LA9FJ4J
LA9FJ4J
LA9FK4K
LA9FL4L
LA9FX970 c
$ Price
53.00
53.00
53.00
76.00
76.00
76.00
76.00
76.00
97.00
113.00
149.00
149.00
149.00
149.00
149.00
508.00
Vertical mounting of 2 contactors of different ratings a
Upper Contactor
L1
d
d
d
d
d
d
d
b
LA9FF970
LA9FF970
LA9FG970
LA9FJ970
LA9FJ970
LA9FJ970
LA9FJ970
LA9FL970
Set of Power Connections
LC1F115/4
LC1F150/4
LC1F185/4
LC1F265/4
LC1F330/4
LC1F400/4
LC1F500/4
LC1F630/4
Vertical Mounting
LC1F115/4
LC1F185/4
LC1F265/4
LC1F330/4
LC1F400/4
LC1F500/4
LC1F630/4
LC1F780/4
LA9FX970
106.00
96.00
113.00
151.00
225.00
225.00
306.00
568.00
$ Price
Component parts for the assembly of TeSys F 3-pole or 4-pole transfer
contactors
Horizontal
Mounting
LA9F•4•
LA9FF976
LA9F15076
LA9FG976
LA9FH976
LA9FJ976
LA9FJ976
LA9FK976
LA9FL976
Mechanical Interlock Kit
Catalog Number
$ Price
Lower Contactor e
Mechanical Interlock Kit
Catalog Number
LA9FG4F
LA9FH4F
LA9FH4G
LA9FJ4F
LA9FJ4G
LA9FJ4H
LA9FK4F
LA9FK4G
LA9FK4H
LA9FK4J
LA9FL4F
LA9FL4G
LA9FL4H
LA9FL4J
LA9FL4K
LC1F115/150 or 1154/1504
LC1F115/150 or 1154/1504
LC1F185/1854 or 265/265A
LC1F115/150 or 1154/1504
LC1F400 or 4004
LC1F185 or 1854
LC1F265/2654 or 330/330A
LC1F115/150 or 1154/1504
LC1F185 or 1854
LC1F500 or 5004
LC1F265/2654 or 330/330A
LC1F400 or 4004
LC1F115/150 or 1154/1504
LC1F185 or 1854
LC1F630, 6304 or LC1F265/2654 or 330/330A
LC1F800
LC1F400 or 4004
LC1F500 or 5004
a
With identical or different numbers of poles.
b
Double mechanical interlock with 2 mechanical links and 3 power connection bars.
c
Double mechanical interlock with 2 mechanical links and 4 power connection bars.
d
Power connection to be assembled by the customer, except for contactors LC1F780 and F7804.
e
Lower contactor must have equal or lower current rating.
$ Price
113.00
126.00
126.00
126.00
126.00
149.00
149.00
126.00
149.00
149.00
116.00
126.00
149.00
149.00
149.00
2L3
2L2
2N
1
3
5
7
1
3
5
7
2
4
6
8
2
4
6
8
A1
A2
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7
TeSys F overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys F replacement coils and parts . . . . . . . . . . . . . . .pages 18-18 to 18-20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-42 to 18-47
L1 L2 L3 N
Transfer/Changeover Applications
© 2009 Schneider Electric
All Rights Reserved
I12
Discount
Schedule
18-15
IEC CONTACTORS AND
STARTERS
With
2 Identical
Contactors a
18
Table 18.43:
TeSys® D and F Overload Relay Accessories
Overload Relays
Refer to Catalog 8502CT9901
www.schneider-electric.us
TeSys D Overload Relay Accessories
Table 18.46:
Mounting Kits and Platesa
Description
LA7D901
For use with overload relays:
LRD01–35 and LR3D01–35
LRD01–35 and LRD01–35
for ring tongue terminals
Separate mounting kits for mounting to 35 mm
LRD15••
DIN rail or for panel mounting with screws
LR2D15••
LR2D25••
LRD3•••, LR3D3•••, LR2D35••
LRD01–35, LR3D01–35, LR2D15••
Mounting plates for screw mounting
LR2D25••
at 110 mm (4.3") centers
LRD3•••, LR3D3••, LR2D35••
a
When using mounting plates, separate mounting kits are also required.
Table 18.47:
Catalog Number
LAD7B10
LAD7B106
8.70
LAD7B105
LA7D1064
LA7D2064
LA7D3064
DX1AP25
DX1AP26
LA7D902
10.40
8.70
13.10
17.50
11.00
12.00
16.40
Accessories
Description
Standard
Packaging
10
10
For use with
18
Pre wiring kit allows direct connection of the N.C. contact LC1D09 through D18
of relay LRD01–D32 or LR3D01–D32 to the contactor LC1D25, D32
All relays except LRD01–D32, LR3D01–D32 and
Stop button locking device
LR9D
LRD01-D32, LRD3, LR3D01-D32, LR3D3
Remote stop/tripping or electrical resetc
All relays except LRD01–D32, LR3D01–D31
Reset by flexible cable 500 mm (19.6 in.)
LRD01-D32, LRD3, LR3D3
b
Part number to be completed by adding coil voltage code. For example: LAD703F.
IEC CONTACTORS AND
STARTERS
LA7D03
Table 18.48:
c
d
$ Price
8.70
Catalog Number
$ Price
LAD7C1
LAD7C2
8.70
8.70
10
LA7D901
2.20
1
1
1
LAD703b
LA7D03b
LAD7305
43.70
43.70
100.00
Control Circuit Voltages for LA7D03 and LAD703
Volts
12
24
48
110
220/230
380/400
415/440
AC 50/60 Hz
Jd
B
E
F
M
Q
N
DC
J
B
E
F
M
—
—
The time that the LA7D03 can remain energized depends on its rest time; 1 s pulse with 9 s rest time; 5 s pulse with 30 s rest time; 10 s pulse with 90 s
rest time; maximum pulse duration of 20 s with rest time of 300 s. Consumption on inrush and sealed: < 100 VA
Not available for LRD01-D32, LR3D01-D32.
TeSys F Overload Relay Accessories
Table 18.49:
Mounting plate for overload relay
For use with relays
LR9F5•57, F5•63, F5•67, F5•69 and F5•71
LR9F7•75, F7•79 and F7•81
Catalog Number
LA7F901
LA7F902
$ Price
27.30
38.20
LA7F90•
These clear plastic protective shrouds are an effective means to meet international finger-safe requirements for power
terminals. They are designed to be used with power cables that have been bolted to the terminal.
NOTE: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits.
Table 18.50:
Power terminal protection shrouds, single-pole
For use with relays
LR9F5•57
LR9F5•63, F5 67, F5•69
LR9F5•71
LR9F7•75, F7•79, F7•81
t
Table 18.51:
LR9F5•57, F5•63, F5•67, F5•69
LR9F5•71
LR9F7•75, F7•79, F7•81
Table 18.52:
For relays
LR9F5•57, F5•63, F5•67, F5•69
LR9F5•57, F5 63
LR9F5•71
LR9F7•75, F7 •• 79
LR9F7•81
LR9F7•75, F7•79, F7•81
LR9F7•81
e
Mounting plate required.
For contactor
LC1F115
LC1F150 and F185
LC1F265
LC1F265...F400
LC1F400
LC1F500
LC1F630
t
Table 18.53:
Catalog Number
LA7F701
LA7F702
LA7F703
$ Price
27.30
38.20
49.20
Connection accessories (for mounting overload relays beneath reversing contactors)e
Application
LA7F701
$ Price
42.40
61.00
86.00
82.00
Power terminal protection shrouds, 3-pole
For use with relays
LA9F70•
Catalog Number
LA9F701
LA9F702
LA9F705
LA9F703
Set of 3 bars
Catalog Number
LA7F401
LA7F402
LA7F403
LA7F404
LA7F404
LA7F405
LA7F406
$ Price
19.70
21.80
27.30
30.50
30.50
38.20
43.70
Marking accessories
Description
Marker holder, snap-in
Sold in units of:
100
Catalog Number
LA7D903
$ Price
.03 each
Main overload selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-2, 18-3
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-45 to 18-47
TeSys T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91
18-16
I12
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® D and Old D2 AC Coils
Contactors Repair Parts
Refer to Catalog 8502CT9901
www.schneider-electric.us
Rated Nominal Voltage
Catalog Number 50/60 Hz
12
21a
24
32
36
42
48
60
100
110
115
120
127
200
208
220/230
230
230/240
277
380/400
400
415
440
480
575
600
690
LXD1J7
LXD1Z7
LXD1B7
LXD1C7
LXD1CC7
LXD1D7
LXD1E7
LXD1EE7
LXD1K7
LXD1F7
LXD1FE7
LXD1G7
LXD1FC7
LXD1L7
LXD1LE7
LXD1M7
LXD1P7
LXD1U7
LXD1W7
LXD1Q7
LXD1V7
LXD1N7
LXD1R7
LXD1T7
LXD1SC7
LXD1X7
LXD1Y7
Specifications
$ Price
26.20
26.20
26.20
26.20
26.20
26.20
50/60 Hz
Average consumption
- Inrush (inductance .75)
- Sealed (inductance .3)
70 VA
7 VA
80–110% of nominal @ 50 Hz,
Operating range@ 60
85–110% of nominal @ 60 Hz
Voltage for special coils fitted in contactors with serial timer modules,
with 24 V supply.
oC
a
Table 18.56:
Table 18.55:
Rated Nominal
Voltage V
For LC1D09, D12, D18—For old D2 style
contactors where the catalog number
includes the auxiliary contact
arrangement
Catalog
Number
50 Hz
LX1D2Z5
LX1D2B5
LX1D2C5
LX1D2D5
LX1D2E5
LX1D2F5
—
LX1D2G5
—
LX1D2M5
LX1D2P5
LX1D2U5
LX1D2W5
—
LX1D2Q5
LX1D2V5
LX1D2N5
LX1D2R5
—
LX1D2S5
—
—
LX1D2Y5
Catalog
Number
60 Hz
LX1D2Z6
LX1D2B6
—
—
LX1D2E6
LX1D2F6
LX1D2G6
—
LX1D2L6
LX1D2M6
—
LX1D2U6
—
LX1D2W6
LX1D2Q6
—
—
LX1D2R6
LX1D2T6
—
LX1D2S6
LX1D2X6
—
21 b
24
32
42
48
110
120
127
208
220
230
240
256
277
380
400
415
440
480
500
575
600
660
Specifications
Average
50 Hz
60 Hz
consumption
Inrush
60 VA
70 VA
(inductance .75)
Sealed
7 VA
7.5 VA
(inductance .3)
80–110 % of
80–110% of
Operating range
at θ < 55oC / 131oF nominal voltage nominal voltage
Catalog
Number
50/60 Hz
LX1D2Z7
LX1D2B7
—
LX1D2D7
LX1D2E7
LX1D2F7
LX1D2G7
—
—
LX1D2M7
LX1D2P7
LX1D2U7
—
—
LX1D2Q7
LX1D2V7
LX1D2N7
LX1D2R7
—
—
—
—
—
$ Price
52.40
ys
k
S
c
to th Te
S
ed d wi
t
i
Limplace
re
e
ll b
i
W
52.40
52.40
52.40
52.40
50/60 Hz
70 VA at 50 or 60 Hz
8 VA at 50 or 60 Hz
85–110% of
nominal voltage
For LC1D25, D32—For old D2 style contactors where the catalog number includes the auxiliary
contact arrangement
Rated Nominal Voltage (V)
21b
24
32
42
48
110
120
127
208
220
230
240
256
277
380
400
415
440
480
500
575
600
660
Catalog Number 50 Hz
Catalog Number 60 Hz
Catalog Number 50/60 Hz
LX1D4Z5
LX1D4B5
LX1D4C5
LX1D4D5
LX1D4E5
LX1D4F5
—
LX1D4G5
—
LX1D4M5
LX1D4P5
LX1D4U5
LX1D4W5
—
LX1D4Q5
LX1D4V5
LX1D4N5
LX1D4R5
—
LX1D4S5
—
—
LX1D4Y5
LX1D4Z6
LX1D4B6
—
—
LX1D4E6
LX1D4F6
LX1D4G6
—
LX1D4L6
LX1D4M6
—
LX1D4U6
—
LX1D4W6
LX1D4Q6
—
—
LX1D4R6
LX1D4T6
—
LX1D4S6
LX1D4X6
—
LX1D4Z7
LX1D4B7
—
LX1D4D7
LX1D4E7
LX1D4F7
LX1D4G7
—
—
LX1D4M7
LX1D4P7
LX1D4U7
—
—
LX1D4Q7
LX1D4V7
LX1D4N7
LX1D4R7
—
—
—
—
—
50 Hz
60 Hz
50/60 Hz
90 VA
7.5 VA
100 VA
8.5 VA
100 VA at 50 or 60 Hz
8.5 VA at 50 or 60 Hz
ys
k
S
c
e
to th T
S
ed d wi
t
i
Limplace
re
e
ll b
Wi
$ Price
72.00
72.00
72.00
72.00
72.00
Specifications
Average consumption
- Inrush (inductance .75)
- Sealed (inductance .3)
Operating range
80–110% of
80–110% of
85–110% of
at θ < 55oC / 131oF
nominal voltage
nominal voltage
nominal voltage
b
For use in 24 volt applications involving serial timer modules refer to page 18-10.
TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
© 2009 Schneider Electric
All Rights Reserved
I12
Discount
Schedule
IEC CONTACTORS AND
STARTERS
LX1D2
For LC1D09–D32, LC1DT20–40
(TeSys D) Contactors and CAD Relays
18
Table 18.54:
18-17
TeSys® D, Old D2, and F AC Coils
Contactors Repair Parts
Refer to Catalog 8502CT9901
www.schneider-electric.us
Table 18.57:
18
IEC CONTACTORS AND
STARTERS
Rated
Nominal
Voltage V
24
32
42
48
110
120
127
208
220
230
240
256
277
380
400
415
440
480
500
575
600
660
For old D2 style LC1D40, D50, Table 18.58:
D65, D80
Catalog
Number
50 Hz
LX1D6B5
LX1D6C5
LX1D6D5
LX1D6E5
LX1D6F5
—
LX1D6G5
—
LX1D6M5
LX1D6P5
LX1D6U5
LX1D6W5
—
LX1D6Q5
LX1D6V5
LX1D6N5
LX1D6R5
—
LX1D6S5
—
—
LX1D6Y5
Catalog
Number
60 Hz
LX1D6B6
—
—
LX1D6E6
LX1D6F6
LX1D6G6
—
LX1D6L6
LX1D6M6
—
LX1D6U6
—
LX1D6W6
LX1D6Q6
—
—
LX1D6R6
LX1D6T6
—
LX1D6S6
LX1D6X6
—
Catalog
Number
50/60 Hz
LX1D6B7
—
LX1D6D7
LX1D6E7
LX1D6F7
LX1D6G7
—
LX1D6LE7
LX1D6M7
LX1D6P7
LX1D6U7
—
—
LX1D6Q7
LX1D6V7
LX1D6N7
LX1D6R7
—
—
—
—
—
$ Price
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
170.00
41.50
41.50
41.50
41.50
41.50
41.50
170.00
41.50
41.50
41.50
For old style and new TeSys style contactors where the catalog
number may or may not include the auxiliary contact arrangement.
Specification
50 Hz
Average consumption:
-inrush (inductance .75) 200 VA
-sealed (inductance .3) 20 VA
Operating range
at θ < 55oC / 131oF
60 Hz
50/60 Hz
Rated
Nominal
Voltage V
12
24
32
42
48
100
110
115
120
127
200
208
220
230
240
277
380
400
415
440
480
500
575
600
660
690
For TeSys D LC1D40A, D50A, Table 18.59:
D65A, DT60A, DT80A
Catalog
Number
50 Hz
LXD3J5
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Specification
Catalog
Number
60 Hz
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
50 Hz
Average consumption:
220 VA 245 VA at 50 or 60 Hz -inrush (inductance .3) 160 VA
22 VA 26 VA at 50 or 60 Hz -sealed (inductance .3) 7.0 VA
80–110% 80–110%
of nominal of nominal
voltage
voltage
85–110%
of nominal voltage
Operating range at
θ < 55oC / 131oF
Catalog
Number
50/60 Hz
—
LXD3B7
LXD3C7
LXD3D7
LXD3E7
LXD3K7
LXD3F7
LXD3FE7
LXD3G7
LXD3FC7
LXD3L7
LXD3LE7
LXD3M7
LXD3P7
LXD3U7
LXD3W7
LXD3Q7
LXD3V7
LXD3N7
LXD3R7
LXD3T7
LXD3S7
LXD3SC7
LXD3X7
LXD3YC7
LXD3Y7
60 Hz
$ Price
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
41.50
Rated
Nominal
Voltage V
24
32
42
48
110
115
120
127
208
220/230
230
240
277
380/400
400
415
440
480
500
For TeSys D LC1D115, D150
Catalog
Number
50 Hz
LX1D8B5
LX1D8C5
LX1D8D5
LX1D8E5
LX1D8F5
LX1D8FE5
—
LX1D8FC5
—
LX1D8M5
LX1D8P5
LX1D8U5
—
LX1D8Q5
LX1D8V5
LX1D8N5
LX1D8R5
—
LX1D8S5
Catalog
Number
50/60 Hz
LX1D8B7
LX1D8C7
LX1D8D7
LX1D8E7
LX1D8F7
LX1D8FE7
LX1D8G7
LX1D8FC7
LX1D8L7
LX1D8M7
LX1D8P7
LX1D8U7
LX1D8W7
LX1D8Q7
LX1D8V7
LX1D8N7
LX1D8R7
LX1D8T7
LX1D8S6
$ Price
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
78.00
For old style and new TeSys style contactors where the catalog
number may or may not include the auxiliary contact arrangement.
50/60 Hz
Specification
Average consumption:
140 VA 140 Va (Inductance: .9) -inrush (inductance .3)
7.5 VA 7.5 Va (Inductance: .9) -sealed (inductance .3)
85–110% 85–110%
of nominal of nominal
voltage
voltage
Catalog
Number
60 Hz
LX1D8B6
—
—
LX1D8E6
LX1D8F6
—
LX1D8G6
—
LX1D8L6
LX1D8M6
—
LX1D8U6
LX1D8W6
LX1D8Q6
—
—
LX1D8R6
LX1D8T6
—
80–115%
of nominal voltage
Operating range at
θ < 55oC / 131oF
50 Hz
60 Hz
50/60 Hz
300 VA
22 VA
300 VA
22 VA
350 Va (Inductance: .9)
18 Va (Inductance: .9)
85–110% 85–110%
of nominal of nominal
voltage
voltage
80–115%
of nominal voltage
Table 18.60:
For LC1F115, F150, F185, F265, F330, F400, F500, F630, F780, F800 —
LX1 coils are the standard coils that are included when a voltage code is added to the contactor part number. The LX9 coils may be ordered separately for special
applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block with a N.O. contact should be added to the
contactor. Both the LX1 and LX9 coils can be used on the previous F-line contactors.
Device
Type
LX1D6
Hz
50
F115–F150
60
40–400
50
F185
60
F225
40–400
40–400
F265–F330
40–400
40–400
F400d
40–400
40–400
F500d
40–400
40–400
F630d
40–400
F780, FX c 40–400
F800
50/60
c
d
e
f
g
Catalog
Number
24 V
48 V
110 V
120 V
208 V
Catalog Number Suffixg
220 V 240 V 277 V 380 V
415 V
440 V
480 V
600 V
$ Price
LX1FF•
LX1FF•
LX9FF•
LX1FG•
LX1FG•
LX9FG•
LX1FH•
LX9FH•
LX1FJ•
LX9FJ• f
LX1FK•
LX9FK• f
LX1FL•
LX9FL• f
LX1FX•
LX4F8• e
024
020
—
024
020
—
0242
—
—
910
—
910
—
910
—
—
048
040
048
048
040
048
0482
0482
048
917
048
917
048
917
—
—
110
092
110
110
092
110
1102
1102
110
925
110
925
110
924
110
FW
127
095
127
127
095
127
1272
1272
110
925
110
925
110
925
110
FW
200
162
200
200
162
200
2002
2002
200
930
200
930
200
930
200
—
220
184
220
220
184
220
2202
2202
220
931
220
931
220
930
220
MW
415
340
415
415
340
415
3802
3802
415
936
415
936
415
936
415
QW
415
360
415
415
360
415
4402
...
415
937
415
937
415
936
415
QW
500
380
500
450
380
500
5002
5002
415
937
415
937
415
937
415
—
600
475
—
600
475
—
6002
—
600
—
600
—
600
—
—
—
78.00
78.00
78.00
108.00
108.00
108.00
138.00
138.00
287.00
287.00
360.00
360.00
398.00
483.00
795.00
725.00
LC1F780 contactors operate on 2 coils as a set. The LX1FX part
number includes both coils.
The 600 V coils for the F400, F500 and F630 do not include an auxiliary
contact for holding circuits. If required, select appropriate contacts from
page 18-8.
Also requires rectifier DR5TE4U for 110 V–240 V coils, DR5TE4S for
380 V–440 V coils. See table below for pricing.
Coil circuit requires a separately mounted rectifier. Order from
Rectifier Table.
Complete catalog number by adding suffix. For example: LX1FF024.
240
187
220
240
187
220
2402
2402
240
932
240
932
240
931
220
MW
264
220
260
264
220
260
2772
2772
280
932
280
932
260
932
280
—
Table 18.61:
Coil
LX9F•910
LX9F•917
LX9F•925
LX9F•926
LX9F•931
LX9F•936
LX9F•937
LX9F•938
380
316
380
380
316
380
3802
3802
380
936
380
936
380
935
380
QW
Rectifier Table
Rectifier Catalog Number
DR5TF4V
DR5TF4V
DR5TE4U
DR5TE4U
DR5TE4U
DR5TE4S
DR5TE4S
DR5TE4S
$ Price
75.00
75.00
75.00
75.00
75.00
75.00
75.00
75.00
Application Note on Contactor Drop-out Times:
Contactors using LX1, FH, FJ, FK, FL, and FX coils have
longer drop-out times. For critical applications such as
emergency stop functions:
•
•
•
18-18
Select a fast drop-out coil (LX9), or
Use a maintained contact Stop button, or
Use an interposing relay.
I12
Discount
Schedule
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
TeSys F contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-17 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-40 to 18-47
© 2009 Schneider Electric
All Rights Reserved
TeSys® D, and Old D2 DC Coils
Contactors Repair Parts
Refer to Catalog 8502CT9901
www.schneider-electric.us
For old D2 LP1D09, D12, D18 Contactors
ac
ys
k
S
c
to th Te
S
ed d wi
t
i
Limplace
re
e
ll b
i
W
Catalog Number
Catalog Number
Wide range
12
21b
24
36
48
60
72
110
125
220
250
440
600
LX4D2JD
LX4D2ZD
LX4D2BD
LX4D2CD
LX4D2ED
LX4D2ND
LX4D2SD
LX4D2FD
LX4D2GD
LX4D2MD
LX4D2UD
LX4D2RD
LX4D2XD
LX4D2JW
—
LX4D2BW
LX4D2CW
LX4D2EW
—
LX4D2SW
LX4D2FW
—
LX4D2MW
—
—
—
$ Price
79.00
79.00
79.00
79.00
79.00
79.00
79.00
79.00
79.00
79.00
79.00
79.00
79.00
Table 18.63:
9W
80–110% of
nominal voltage
11 W
70–125% of
nominal voltage
For old D2 LP1D25, D32 ac
Catalog
Number
Catalog Number
Wide range
$ Price
12
21 b
24
36
48
60
72
110
125
220
250
440
600
LX4D4JD
LX4D4ZD
LX4D4BD
LX4D4CD
LX4D4ED
LX4D4ND
LX4D4SD
LX4D4FD
LX4D4GD
LX4D4MD
LX4D4UD
LX4D4RD
LX4D4XD
LX4D4JW
—
LX4D4BW
LX4D4CW
LX4D4EW
—
LX4D4SW
LX4D4FW
—
LX4D4MW
—
—
—
110.00
110.00
110.00
110.00
110.00
110.00
110.00
110.00
110.00
110.00
110.00
110.00
110.00
s
y
k
S
toc th Te
S
ed d wi
t
i
Limplace
re
e
b
ll
Wi
Specifications
Average consumption
11 W
13 W
80–110% of nominal
70–125% of nominal
Operating range at
o
o
voltage
voltage
θ < 55 C / 131 F
a
For old style contactors where the catalog number includes the auxiliary
contact arrangement (ex. LP1D2510). The new style TeSys DC
controlled contactors (ex. LC1D25BD) do not have replaceable coils.
b
For use in 24 volt applications with serial timer modules. Refer
to page 18-10.
c
No replacement DC coils for TeSys D contactors.
Note: DC coils for LC1D09-D32, LC1DT20 - LC1DT40, and LCIDttA
contactors are not replaceable.
Specifications
LCIDttA
LC1D09-D32,
LC1DT20 - LC1DT40
© 2009 Schneider Electric
All Rights Reserved
Average consumption
Inrush 5.4 w
Sealed 5.4 w
Inrush 19 w
Sealed 7.4 w
Low consumption
Inrush 2.4 w
Sealed 2.4 w
I12
Catalog Number
Wide range
12
24
36
48
60
72
110
125
220
250
440
600
LX4D6JD
LX4D6BD
LX4D6CD
LX4D6ED
LX4D6ND
LX4D6SD
LX4D6FD
LX4D6GD
LX4D6MD
LX4D6UD
LX4D6RD
LX4D6XD
LX4D6JW
LX4D6BW
LX4D6CW
LX4D6EW
—
LX4D6SW
LX4D6FW
—
LX4D6MW
—
—
—
$ Price
124.00
124.00
124.00
Specifications
Table 18.65:
Rated
Nominal Voltage
V
LC1D09-D32,
LC1DT20 - LC1DT40
Catalog
Number
Average consumption
22 W
23 W
Operating range at
80–110%
75–120%
θ < 55oC /131oF
of nominal voltage of nominal voltage
Specifications
Average consumption
Operating range at
θ–55oC / 131oF
For old D2 LP1D40, D50, D65 ac
Rated
Nominal Voltage
V
For old D2 LP1D80 and LC1D80a
Rated
Nominal Voltage
V
Number
Catalog Number Catalog
Wide Range d
12
24
36
48
60
72
110
125
220
250
440
600
LX4D7JD
LX4D7BD
LX4D7CD
LX4D7ED
LX4D7ND
LX4D7SD
LX4D7FD
LX4D7GD
LX4D7MD
LX4D7UD
LX4D7RD
LX4D7XD
LX4D7JW
LX4D7BW
LX4D7CW
LX4D7EW
—
LX4D7SW
LX4D7FW
—
LX4D7MW
—
—
—
$ Price
134.00
134.00
134.00
Specifications
Average consumption
22 W
23 W
Operating range
80–110%
70–120%
o
o
at θ < 55 C / 131 F
nominal voltage
nominal voltage
d
Wide range coils cannot be used with contactors utilizing both front and
side mount auxiliaries.
Table 18.66:
For TeSys D LC1D115, 150
Rated Nominal Voltage
V
Catalog Number
24
48
60
72
110
125
220
250
440
LX4D8BD
LX4D8ED
LX4D8ND
LX4D8SD
LX4D8FD
LX4D8GD
LX4D8MD
LX4D8UD
LX4D8RD
Average consumption
Operating range at
θ < 55oC / 131oF
Inrush 365 W, Sealed 5 W
70%–120% of
nominal voltage
$ Price
78.00
78.00
Operating range
70 - 125% @ 60oC
75 - 125% @ 60oC
70 - 125% @ 60oC
Discount
Schedule
IEC CONTACTORS AND
STARTERS
Rated
Nominal Voltage
V
Table 18.64:
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
18-19
18
Table 18.62:
TeSys® F DC Coils
Contactors Repair Parts
Refer to Catalog 8502CT9901
www.schneider-electric.us
TeSys F DC Coils
LX4 coils are the standard coils when a voltage code is added to the part number. The LX9 coils may be ordered
separately for special applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate
auxiliary contact block with a N.O. contact should be added to the contactor. Both the LX4 and LX9 coils can be used
on previous F-line devices.
Table 18.67:
Device
Type
LX4 coils for LC1F115, F150, F185, F265, F400, F500, F630, F780, F800
•
Catalog
Number
24 V
•
•
•
•
•
•
•
•
•
•
•
F115, F150
F185, F225
F265, F330
36V
48 V
60 V
72 V
Catalog Number Suffix
110 V
125 V
18
LX4FF
024
035
048
060
070
110
125
LX4FG
024
035
048
060
070
110
125
024
035
048
060
070
110
125
LX4FH
LX4FJ
—
—
048
060
070
110
125
F400
LX9FJ c
—
—
918
—
—
926
927
—
—
048
060
070
110
125
LX4FK
F500
LX9FK c
—
—
918
—
—
926
927
—
—
048
060
070
110
125
LX4FL
F630
—
—
918
—
—
926
927
LX9FK c
F780
LX4FX a
—
—
—
—
—
110
125
F800
LX4F8 b
—
—
—
—
—
FW
FW
a
LC1F780 contactors operate on 2 coils as a set. The LX4FX part number includes both coils.
b
Also requires rectifier DR5TE4U, $72.00 list price.
c
Coil Circuit requires a separately mounted resistor. Order from Table 18.68 below.
220 V
250 V
440 V
220
220
220
220
932
220
932
220
932
220
MW
250
250
250
250
—
250
—
250
—
250
—
440
440
440
440
938
440
938
440
938
440
QW
$ Price
78.00
108.00
138.00
287.00
287.00
360.00
360.00
398.00
398.00
795.00
725.00
Table 18.68:
IEC CONTACTORS AND
STARTERS
Coil
Resistor
Catalog
Number
LX9FJ918
LX9FJ926
LX9FJ927
LX9FJ932
LX9FJ938
DR2SC0047
DR2SC0030
DR2SC0390
DR2SC1200
DR2SC4700
Qty.
Required $ Price
1
1
1
1
1
13.70
13.80
13.70
13.70
13.70
Coil
Resistor
Catalog
Number
Qty.
Required
LX9FK918
LX9FK926
LX9FK927
LX9FK932
LX9FK938
DR2SC0039
DR2SC0220
DR2SC0330
DR2SC1000
DR2SC3300
1
1
1
1
1
$ Price
13.70
13.70
13.70
13.70
13.70
Coil
Resistor
Catalog
Number
Qty.
Required
LX9FL918
LX9FL925
LX9FL926
LX9FL931
LX9FL937
DR2SC0047
DR2SC0270
DR2SC0330
DR2SC1000
DR2SC3900
2
2
2
2
2
$ Price
13.70
13.70
13.70
13.70
13.70
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-5, 18-7
TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys F replacement coils and parts . . . . . . . . . .pages 18-18, 18-18, 18-20
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47
18-20
I12
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® D in Metal Enclosures
Enclosed Starters
Refer to Catalog 8502CT9901
www.schneider-electric.us
TeSys D enclosed full voltage starters are available in Type 1 and Type 12/3R enclosures through 50 hp at 460 V. The
enclosed D-line accepts standard D-Line accessories and all Insta-Kits™ control units and control power transformer
kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure.
For extra capacity, please refer to your local distributor or nearest Square D/Schneider Electric sales office.
Enclosed Full Voltage Non-reversing Starters
Max. Horsepower Ratings (AC3)
1 Phase
3 Phase
115
230
200 V
230 V
460 V
575V
0.333
1
2
3
3
5
5
7.5
10
15
2
3
5
5
7.5
10
12
20
30
2
3
5
7.5
10
10
15
20
30
5
7.5
10
15
20
30
40
40
60
7.5
10
15
20
25
30
40
50
60
1
2
2
3
3
5
7.5
Table 18.70:
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Auxiliary Contacts On Each
Contactor
200V
230 V
460 V
575 V
N.O.
N.C.
2
3
5
5
7.5
10
12
20
30
2
3
5
7.5
10
10
15
20
30
5
7.5
10
15
20
30
40
40
60
7.5
10
15
20
25
30
40
50
60
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Current Rating Catalog Number
of Contactor
Type 1
9
12
18
25
32
40
50
65
80
Catalog Number Nomenclature
Catalog Number Example:
$ Price
Type 12/3R
109.
137.
153.
170.
191.
273.
300.
393.
473.
LE1D093A72•••••
LE1D123A72•••••
LE1D183A72•••••
LE1D253A72•••••
LE1D323A72•••••
LE1D403A72•••••
LE1D503A72•••••
LE1D653A72•••••
LE1D803A72•••••
175.
202.
219.
235.
245.
393.
420.
514.
610.
LE2D093A62•••••
LE2D123A62•••••
LE2D183A62•••••
LE2D253A62•••••
LE2D323A62•••••
LE2D403A62•••••
LE2D503A62•••••
LE2D653A62•••••
LE2D803A62•••••
$ Price
Catalog Number
$ Price
Type 12/3R
305.
355.
385.
415.
464.
655.
710.
900.
1248.
LE2D093A72•••••
LE2D123A72•••••
LE2D183A72•••••
LE2D253A72•••••
LE2D323A72•••••
LE2D403A72•••••
LE2D503A72•••••
LE2D653A72•••••
LE2D803A72•••••
382.
453.
483.
513.
573.
819.
874.
1030.
1412.
iOverload
Relay Range
Select code from the below:
LE1D093A62 O G 7 1 07
Base Catalog Number
Wiring Method
Control Power Transformer f
Contactor/Starter Coil Voltage g
Coil Frequency h
Overload Relay Type j
Overload Relay Range i
fControl
Power Transformer
Add price from page 18-23. Select letter for primary
voltage of CPT:
Voltage
No Transformer used
208
240
480
600
Code
Oa
L
M
T
X
a
Letter O, not zero.
Note: If control transformer is used, the only options available are 24 or 120
volts as the secondary of the transformer. Also, DC voltages are not
available when control power transformer is used.
gContactor/Starter
Coil Voltage
Select coil voltage from table:
Voltage
24
120
208
240
480
AC
B
G
L
U
T
X
DC
B
—
—
—
—
—
hCoil
LE1D093A62•••••
LE1D123A62•••••
LE1D183A62•••••
LE1D253A62•••••
LE1D323A62•••••
LE1D403A62•••••
LE1D503A62•••••
LE1D653A62•••••
LE1D803A62•••••
Catalog Number
Enclosed Full Voltage Reversing Starters
Max. Horsepower Ratings (AC3) 3 Phase
Table 18.71:
9
12
18
25
32
40
50
65
80
$ Price
600
Frequency
Select:
7 = dual frequency coils (50/60 Hz.)
6 = 60 Hz.
D=DC
Note: For 9 to 65 A contactors, only dual frequency coils are available; 80
A contactors, the 24 V to 240 V coils are dual frequency only (50/60
Hz.). The 480 V to 600 V coils are 60 Hz. only. See catalog for other
restrictions.
Code
01
02
03
04
05
06
07
08
10
12
13
14
16
18
21
Range
For use on
Contactors
D09–D32b
D09–D32b
D09–D32b
D09–D32b
D09–D32b
D09–D32b
D09–D32b
D09–D32
D09–D32
D09–D32
D40, D50, D65
D09–D32
D12–D32
D40, D50, D65
D18–D32
D25–D32b
D25–D32c
D80
D40, D50, D65
D25–D32c
D25–D32
D40, D50, D65
D40, D50, D65
D40, D50, D65
D80
D80
D80
D80
D65–D80
D65–D80
D40, D50, D65
$ Price Adder
0.1–0.16
60.
0.16–0.25
60.
0.25–0.40
60.
0.40–0.63
60.
0.63–1.0
60.
1.0–1.6
60.
1.6–2.5
60.
2.5–4
60.
4–6
60.
5.5–8
60.
9–13
107.
7–10
62.
9–13
62.
12–18
107.
12–18
62.
16–24
62.
22
17–25
62.
17–25
107.
25
17–25
107.
30
23-28
73.
32
23–32
73.
32
23–32
107.
40
30–40
107.
50
37–50
107.
53
30–38
107.
55
30–40
107.
57
37–50
107.
59
48–65
107.
61
55–70
107.
63
63–80
107.
65
48–65
107.
b
Available for Class 10 only.
c
Available for Class 20 only.
Note: If no overload relay is required, leave this portion of the catalog blank.
Add appropriate Price Adder to the base price of the starter.
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-48
jOverload
relay type
Select:
0 = No overload relay
1 = Class 10 Trip
2 = Class 20 Trip
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
IEC CONTACTORS AND
STARTERS
0.5
Auxiliary Contacts Current Rating Catalog Number
of Contactor
N.O.
N.C.
Type 1
18-21
18
Table 18.69:
TeSys® D Fusible Disconnect Switch or Circuit Breaker
Enclosed Combination
Starters
Refer to Catalog 8502CT9901
www.schneider-electric.us
IEC combination starters combine the requirements of motor overload and short circuit protection in one convenient
compact package. All devices provide Type 2 Coordination through 30 hp at 460 V. Devices are available in Type 1 and
Type 12/3R enclosures. The IEC combination starter line accepts standard TeSys D accessories and all Insta-Kits™
pilot devices and control power transformer kits. Standard capacity control power transformers with built-in fuse block
can be installed in the standard enclosure. For extra capacity, please refer to your local distributor or nearest
Square D/Schneider Electric sales office.
NOTE: Use tables and notes from page 18-21 to complete the catalog numbers.
Table 18.72:
Enclosed full voltage non-reversing fusible combination starters
Max. Horsepower Ratings (AC3)
Fuse Clip Rating
3 Phase
200 V
2
3
5
5
7.5
10
230 V
2
3
5
7.5
10
10
18
Table 18.73:
460 V
5
7.5
10
15
20
30
575 V
7.5
10
15
20
25
30
Amperes
30 A
30 A
30 A
30 A
60 A
60 A
Fuse Clip Rating
3 Phase
IEC CONTACTORS AND
STARTERS
230 V
2
3
5
7.5
10
10
Table 18.74:
460 V
5
7.5
10
15
20
30
575 V
7.5
10
15
20
25
30
Amperes
30 A
30 A
30 A
30 A
60 A
60 A
230 V
2
3
5
7.5
10
10
Table 18.75:
460 V
5
7.5
10
15
20
30
575 V
7.5
10
15
20
25
30
N.O.
1
1
1
1
1
1
N.C.
1
1
1
1
1
1
Auxiliary Contacts
Each Contactor
3 Phase
230 V
2
3
5
7.5
10
10
Table 18.76:
460 V
5
7.5
10
15
20
30
575 V
7.5
10
15
20
25
30
426.
468.
484.
500.
653.
708.
Catalog Number
Type 12/3R
LE1D096B72•••••
LE1D126B72•••••
LE1D186B72•••••
LE1D256B72•••••
LE1D326C72•••••
LE1D406C72•••••
$ Price
551.
592.
607.
623.
829.
877.
Aux. Contacts
Each Contactor
N.O.
1
1
1
1
1
1
N.C.
1
1
1
1
1
1
Current
Rating of
Contactor
9
12
18
25
32
40
Catalog Number
Type 1
LE2D096B62•••••
LE2D126B62•••••
LE2D186B62•••••
LE2D256B62•••••
LE2D326C62•••••
LE2D406C62•••••
$ Price
712.
778.
808.
833.
1089.
1179.
Catalog Number
Type 12/3R
LE2D096B72•••••
LE2D126B72•••••
LE2D186B72•••••
LE2D256B72•••••
LE2D326C72•••••
LE2D406C72•••••
$ Price
837.
915.
950.
980.
1281.
1371.
Circuit Breaker
Maximum
Current Rating
Current
Rating of
Contactor
15 A
15 A
30 A
30 A
50 A
50 A
9
12
18
25
32
40
Catalog Number
Type 1
LE1D097D62•••••
LE1D127D62•••••
LE1D187E62•••••
LE1D257E62•••••
LE1D327F62•••••
LE1D407F62•••••
$ Price
569.
622.
647.
668.
870.
944.
Catalog Number
Type 12/3R
LE1D097D72•••••
LE1D127D72•••••
LE1D187E72•••••
LE1D257E72•••••
LE1D327F72•••••
LE1D407F72•••••
$ Price
730.
789.
808.
834.
1088.
1179.
N.O.
1
1
1
1
1
1
N.C.
1
1
1
1
1
1
Circuit Breaker
Maximum
Current Rating
Current
Rating of
Contactor
15 A
15 A
30 A
30 A
50 A
50 A
9
12
18
25
32
40
Catalog Number
Type 1
LE2D097D62•••••
LE2D127D62•••••
LE2D187E62•••••
LE2D257E62•••••
LE2D327F62•••••
LE2D407F62•••••
$ Price
836.
944.
1010.
1075.
1403.
1522.
Catalog Number
Type 12/3R
LE2D097D72•••••
LE2D127D72•••••
LE2D187E72•••••
LE2D257E72•••••
LE2D327F72•••••
LE2D407F72•••••
$ Price
972.
1096.
1174.
1251.
1631.
1770.
Enclosed full voltage non-reversing non-fused combination starters
Max. Horsepower Ratings (AC3)
3 Phase
230 V
2
3
5
7.5
10
10
Table 18.77:
460 V
5
7.5
10
15
20
30
575 V
7.5
10
15
20
25
30
Fuse Clip Rating
Amperes
30 A
30 A
30 A
30 A
60 A
60 A
UL Class
CC
CC
J
J
J
J
Auxiliary
Contacts
N.O.
1
1
1
1
1
1
N.C.
1
1
1
1
1
1
Current
Rating of
Contactor
9
12
18
25
32
40
Catalog Number
Type 1
LE1D096A62•••••
LE1D126A62•••••
LE1D186A62•••••
LE1D256A62•••••
LE1D326A62•••••
LE1D406A62•••••
$ Price
416.
458.
474.
490.
643.
698.
Catalog Number
Type 12/3R
LE1D096A72•••••
LE1D126A72•••••
LE1D186A72•••••
LE1D256A72•••••
LE1D326A72•••••
LE1D406A72•••••
$ Price
541.
532.
597.
613.
819.
867.
Enclosed full voltage reversing non-fused combination starters
Max. Horsepower Ratings (AC3)
3 Phase
200 V
2
3
5
5
7.5
10
9
12
18
25
32
40
Type 1
LE1D096B62•••••
LE1D126B62•••••
LE1D186B62•••••
LE1D256B62•••••
LE1D326C62•••••
LE1D406C62•••••
$ Price
Enclosed full voltage reversing circuit breaker combination starters
Max. Horsepower Ratings (AC3)
200 V
2
3
5
5
7.5
10
UL Class
CC
CC
J
J
J
J
Auxiliary
Contacts
3 Phase
200 V
2
3
5
5
7.5
10
N.C.
1
1
1
1
1
1
Catalog Number
Enclosed full voltage non-reversing circuit breaker combination starters
Max. Horsepower Ratings (AC3)
200 V
2
3
5
5
7.5
10
N.O.
1
1
1
1
1
1
Current
Rating of
Contactor
Enclosed full voltage reversing fusible combination starters
Max. Horsepower Ratings (AC3)
200 V
2
3
5
5
7.5
10
UL Class
CC
CC
J
J
J
J
Auxiliary
Contacts
230 V
2
3
5
7.5
10
10
460 V
5
7.5
10
15
20
30
575 V
7.5
10
15
20
25
30
Fuse Clip Rating
Amperes
30 A
30 A
30 A
30 A
60 A
60 A
UL Class
CC
CC
J
J
J
J
Aux. Contacts
Each Contactor
N.O.
1
1
1
1
1
1
N.C.
1
1
1
1
1
1
Current
Rating of
Contactor
9
12
18
25
32
40
Catalog Number
Type 1
LE2D096A62•••••
LE2D126A62•••••
LE2D186A62•••••
LE2D256A62•••••
LE2D326A62•••••
LE2D406A62•••••
$ Price
702.
768.
798.
823.
1079.
1169.
Catalog Number
Type 12/3R
LE2D096A72•••••
LE2D126A72•••••
LE2D186A72•••••
LE2D256A72•••••
LE2D326A72•••••
LE2D406A72•••••
$ Price
827.
905.
940.
970.
1271.
1361.
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-48
18-22
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
Enclosed Combination
Starters
Enclosure Modifications/Insta-Kits™/Overload Relay
Refer to Catalog 8502CT9901
www.schneider-electric.us
Factory Modifications and INSTA-KITS™ selection
L1
Add the Factory Modification Code to the end of the catalog number created from page
18-21. With the use of INSTA-KITS™, only one operator scheme is allowed. Only the
combinations of operators and pilot lights shown below can be ordered.
L2
START
STOP
1
23
4 A
Pilot lights will be at the coil voltage indicated in the catalog number for the starter.
Table 18.78:
Start/Stop
L1
ON
X1
X2
OLR
B 95 96
PL
1
23
4 A
61
M
62
X1
X2
PL
On-Off Selector Switch
L1
L2
OFF
X1
HAND AUTO
3
4
3
PL
X2
95 96
M
4
61
62
X1
PL
X2
Remote by Customer Connection
HOA Selector Switch
L1
L2
L3
13
B
M A
14
98
96
97
95
$ Price
Insta-Kits
(for field
installation)
$ Price
Control Units Only
For-rev-stop Push Button
A06L
131.
LA9CA06LT
71.00
Start/Stop Push Button
A06G
65.
LA9CA06GT
32.80
I/O (Start/Stop) Push Button
N/A
—
N/A
—
I/O Push Button (double touch)
A06I
83.
LA9CA06IO
41.50
Emergency Stop
N/A
—
N/A
—
Hand-Off-Auto Selector Switch
A06E
65.
LA9CA06ET
32.80
On/off Selector Switch
A06D
65.
LA9CA06DT
41.50
Start/Mushroom Head Stop Push Button
A06X
65.
LA9CA06XT
63.00
Pilot Lights only
LED Pilot light, 24, 120 or 240 V
A16S
134.
LA9CA16STd
66.00
Green-Red Pilot light, Direct supply, 24 or 120 V b
A06S
112.
LA9CA06STd
62.00
Green-Red Transformer Pilot Light, 120, 208/240, 480
A06F
207.
LA9CA06FTd
113.00
or 600 V b
Available combination of control units and pilot lights
Hand-Off-Auto Selector Switch w/24, 120 or 240 V
A16U
213.
LA9CA16UTd
177.00
LED Pilot Light
Start/Stop Push Button w/ 24, 120 or 240 V LED Pilot
A16V
213.
LA9CA16VTd
177.00
Light
On/off Selector w/ 24, 120 or 240 V LED Pilot Light
A16W
213.
LA9CA16WTd
177.00
Start/Stop Push Button w/ Green-Red Transformer
A06N
177.
LA9CA06NTd
95.00
Pilot Light
Start/Stop Push Button w/Green-Red Pilot Light
A06V
177.
LA9CA06VT
95.00
Hand-Off-Auto Selector Switch w/Green-Red Pilot
A06U
273.
LA9CA06UT
97.00
Light
Hand-Off-Auto Selector Switch w/Green-Red
147.00
A06J
273.
LA9CA06JTd
Transformer Pilot Light
On/off Selector w/Green-Red Pilot Light
A06W
177.
LA9CA06WT
95.00
On/off Selector w/Green-Red Transformer Pilot Light
A06H
273.
LA9CA06HTd
147.00
Control Power Transformer
Standard VA, 2 fuses in Primary, 1 Fuse in secondary
A206P
260.
c
—
50 VA extra, 2 fuses in Primary, 1 Fuse in secondary
A207P
456.
c
—
100 VA extra, 2 fuses in Primary, 1 Fuse in secondary
A208P
634.
c
—
a
Add these forms to the catalog number selected on page 18-21. The numbers as shown are for use in NEMA 1
Enclosures. For uses in NEMA 12/3R change the 6 to a 7 (ex A06U becomes A07U). Price remains the same. The
change DOES NOT apply to control power transformer forms.
b
Pilot lights are wired such that the light is on when the contactor is energized. For non-LED type pilot lights, a green
lens is installed on the unit when shipped. A red lens is included for use as applicable.
c
Select Insta-Kits™ from table below.
L2
OFF
Factory
Modification
Codea
Description
Table 18.79:
T1
T2
T3
D-Line AC Magnetic Starter
2-3 Poll
d
Total VA
Insta-Kits™ Catalog Number
$ Price
50
LA9TFD32d
140.00
100
LA9TFD80d
246.00
150
LA9TFD15d
343.00
™
Complete the part number for the Insta-Kits by selecting the voltage code from the appropriate tables below.
Table 18.80:
L1 L2 L3
21
+
21
B
F A
+
B
R A
24
120
208/240
480
600
Code
B
G
M
T
X
Table 18.81:
+
Primary Voltage
22
+
22
95
98
96
Voltage Codes for control power transformers
120
208
Secondary Voltage
Code
97
Voltage Codes for pilot lights
Voltage (Vac)
240
480
600
208
240
24
E
D
C
480
600
T
X
120
B
A
L
M
"C"
T1 T2 T3
D-Line AC Magnetic Reversing Starter
3-Pole
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
18-23
IEC CONTACTORS AND
STARTERS
14
18
13
OLR
95 96
B
M
®
TeSys K 3-Pole Non-Reversing Contactors
Contactors
Refer to Catalog 8502CT9901
www.schneider-electric.us
3-Pole Non-Reversing Mini-Contactors
Table 18.82:
AC operating coils
Maximum Horsepower Ratings
1Ø
Maximum Current
Inductive Resistive
AC3
AC1
115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp Amperes Amperes
0.5
LC1K0610G7
1.5
1.5
3
3
6
15
Screw-clamp
0.5
1.5
2
3
5
5
9
20
Screw-clamp
0.5
1.5
3
3
7.5
10
12
20
Screw-clamp
Table 18.83:
Catalog
Number
$ Price
N.O.
N.C.
1
—
—
LC1K0610 a b
57.
1
—
1
—
1
—
1
—
1
LC1K0601 ab
LC1K0910 ab
LC1K0901 ab
LC1K1210 ab
LC1K1201 ab
57.
75.
75.
86.
86.
Coil voltage codes for AC contactors
Up to and including 240 V coil with integral suppression device available. Add 2 to the code
required. Example J72. Price adder $10.00.
12
24
42
48
110
120
127
200/
208
220/
230
230
230/
240
277
380/
400
400/
415
440
480
660/
690
Code
J7
B7
D7
E7
F7
G7
FC7
L7
M7
P7
U7
UE7
Q7
N7
R7
T7
Y7
18
Volts AC 50/60 Hz
Table 18.84:
IEC CONTACTORS AND
STARTERS
LP1K0610
1.5
Auxiliary
Contacts
Type of
Connection
3Ø
DC operating coils
0.5
1.5
1.5
1.5
3
3
6
15
Screw-clamp
0.5
1.5
2
3
5
5
9
20
Screw-clamp
0.5
1.5
3
3
7.5
10
12
20
Screw-clamp
Table 18.85:
1
—
1
—
1
—
LP1K0610 ab
LP1K0601 ab
LP1K0910 ab
LP1K0901 ab
LP1K1210 ab
LP1K1201 ab
—
1
—
1
—
1
75.
75.
92.
92.
106.
106.
Coil voltage codes for DC contactors
Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price
adder $10.00.
Volts DC
12
20
24
36
48
60
72
100
110
125
200
220
230
240
250
Code
JD
ZD
BD
CD
ED
ND
SD
KD
FD
GD
LD
MD
MPD
MUD
UD
,
Table 18.86:
DC–Low consumption operating coils (devices have built-in transient suppression)
0.5
1.5
1.5
1.5
3
3
6
15
Screw-clamp
0.5
1.5
2
3
5
5
9
20
Screw-clamp
0.5
1.5
3
3
7.5
10
12
20
Screw-clamp
1
—
1
—
1
—
LP4K06105●
Table 18.87:
a
b
E164862
CCN NLDX
(screw terminals)
LR43364
Class 3211 04
E164862
CCN NLDX2
(slip-on &
solder-pin
terminals)
18-24
LP4K0610
LP4K0601
LP4K0910
LP4K0901
LP4K1210
LP4K1201
ab
ab
ab
ab
ab
ab
92.
92.
110.
110.
126.
126.
Coil voltage codes for DC contactors—Low consumption
Volts DC
12
24
48
Code
JW3
BW3
EW3
For TeSys K contactors with spring terminal clamps, add a “3” before the coil voltage code (ex. LC1K06103G7).
For TeSys K contactors with solder pin terminals, add a “5” before the coil voltage code (ex. LC1K09105B7).
For TeSys K contactors with slip-on terminals, add a “7” before the coil voltage code (ex. LC1K12107M7).
Complete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7.
Table 18.88:
LR2K0316
—
1
—
1
—
1
72
SW3
Overload relays for 3-Pole contactors with screw-clamp terminals
Class 10, Relay setting range–A
Catalog Number
0.1 to 0.16
0.16 to 0.23
0.23 to 0.36
0.36 to 0.54
0.54 to 0.8
0.8 to 1.2
1.2 to 1.8
1.8 to 2.6
2.6 to 3.7
3.8 to 5.5
5.5 to 8
8 to 11.5
10 to 14
LR2K0301
LR2K0302
LR2K0303
LR2K0304
LR2K0305
LR2K0306
LR2K0307
LR2K0308
LR2K0310
LR2K0312
LR2K0314
LR2K0316
LR2K0321
$ Price
59.
59.
59.
59.
59.
59.
59.
59.
59.
59.
59.
59.
59.
LR2K overload relays:
•
•
•
•
•
•
AC or DC protection
Ambient compensated bimetallic
Class 10
Single phase sensitivity
Manual or auto reset
Full load current dial
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-27
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-49
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® K 3-Pole Reversing Contactors
Contactors
Refer to Catalog 8502CT9901
www.schneider-electric.us
3-Pole Reversing Mini-Contactors
AC operating coils
Maximum Horsepower Ratings
1Ø
Maximum Current
3Ø
115V
hp
230V
hp
200V
hp
230V
hp
460V
hp
575V
hp
0.5
1.5
1.5
1.5
3
3
0.5
1.5
2
3
5
0.5
1.5
3
3
7.5
Inductive Resistive
AC3
AC1
A
A
Auxiliary
Contacts
Type of
Connection
6
15
Screw-clamp
5
9
20
Screw-clamp
10
12
20
Screw-clamp
LC2K09107
Volts AC
50/60 Hz
Code
Table 18.91:
12
24
42
48
110
120
127
J7
B7
D7
E7
F7
G7
FC7
1.5
1.5
0.5
1.5
2
3
5
0.5
1.5
3
3
7.5
200/2
08
L7
220/
230
M7
230
P7
3
3
6
15
Screw-clamp
5
9
20
Screw-clamp
10
12
20
Screw-clamp
12
JD
20
ZD
24
BD
36
CD
48
ED
60
ND
72
SD
100
KD
110
FD
1.5
1.5
1.5
3
3
6
15
Screw-clamp
0.5
1.5
2
3
5
5
9
20
Screw-clamp
0.5
1.5
3
3
7.5
10
12
20
Screw-clamp
LP2K09105
a
b
130.
130.
167.
167.
191.
191.
230/
240
U7
380/
400
Q7
277
UE7
400/
415
N7
440
480
R7
T7
660/
690
Y7
1
—
1
—
1
—
LP2K0610 ab
LP2K0601 ab
LP2K0910 ab
LP2K0901 ab
LP2K1210 ab
LP2K1201 ab
—
1
—
1
—
1
167.
167.
202.
202.
232.
232.
125
GD
200
LD
220
MD
230
MPD
240
MUD
250
UD
DC–Low Consumption Operating Coils (devices have built-in transient suppression)
0.5
Table 18.94:
LC2K0610 ab
LC2K0601 ab
LC2K0910 ab
LC2K0901 ab
LC2K1210 ab
LC2K1201 ab
Coil voltage codes for DC contactors
Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price
adder $20.00.
Volts DC
Code
Table 18.93:
—
1
—
1
—
1
DC operating coils
1.5
LP2K0910
1
—
1
—
1
—
$ Price
Coil voltage codes for AC contactors
Up to and including 240 V coil with integral suppression device available. Add 2 to the code
required. Example J72. Price adder $20.00.
0.5
Table 18.92:
N.C.
1
—
1
—
1
—
—
1
—
1
—
1
LP5K0610 ab
LP5K0601 ab
LP5K0910 ab
LP5K0901 ab
LP5K1210 ab
LP5K1201 ab
202.
202.
238.
238.
274.
274.
Coil voltage codes for DC contactors—Low consumption
Volts DC
12
24
48
Code
JW3
BW3
EW3
For TeSys K contactors with spring terminal clamps, add a “3” before the coil voltage code (ex. LP2K09103BD).
For TeSys K contactors with solder pin terminals, add a “5” before the coil voltage code (ex. LP5K09105BW3).
For TeSys K contactors with slip-on terminals, add a “7” before the coil voltage code (ex. LC2K06107B7).
Complete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7.
72
SW3
Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-24
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-27
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-49
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
18-25
IEC CONTACTORS AND
STARTERS
Table 18.90:
Catalog Number
N.O.
18
Table 18.89:
TeSys® K 4-Pole Contactors
Contactors
Refer to Catalog 8502CT9901
www.schneider-electric.us
Table 18.95:
AC Operating Coils
Maximum Horsepower Ratings
1 PH
115 V
hp
Maximum Current
3 PH
230 V
hp
200 V
hp
230 V
hp
460 V
hp
2
3
5
Inductive Resistive
AC3
AC1
A
A
575 V
hp
Power
Poles
Type of Connection
Catalog
Number
N.O.
N.C.
$ Price
4-Pole Mini Contactor
0.5
LC2K090045
1.5
0.5
1.5
3
3
7.5
4-Pole Mechanically Interlocked Contactors
0.5
1.5
2
3
5
0.5
1.5
3
3
7.5
Table 18.96:
5
9
15
Screw-clamp
10
12
20
Screw-clamp
4
2
4
—
2
—
LC1K09004 ab
LC1K09008 ab
LC1K12004 ab
75.
81.
86.
5
10
9
12
20
20
Screw-clamp
Screw-clamp
4
4
—
—
LC2K09004 ab
LC2K12004 ab
167.
191.
Coil voltage codes for AC contactors
Up to and including 240 V coil with integral suppression device available. Add 2 to the code
required. Example J72. Price adder $10.00 ($20.00 for mechanically interlocked contactors)
Volts AC 50/60 Hz
12
24
42
48
110
120
127
Code
J7
B7
D7
E7
F7
G7
FC7
Table 18.97:
200/208 220/230
L7
230
230/ 240
277
P7
U7
UE7
M7
380/400 400/415
Q7
N7
440
480
660/690
R7
T7
Y7
DC operating coils
18
4-Pole Mini Contactor
0.5
1.5
2
3
5
IEC CONTACTORS AND
STARTERS
0.5
1.5
3
3
7.5
4-Pole Mechanically Interlocked Contactors
0.5
1.5
2
3
5
0.5
1.5
3
3
7.5
Table 18.98:
Screw-clamp
4
2
4
—
2
—
LP1K09004 ab
LP1K09008 ab
LP1K12004 ab
92.
98.
106.
Screw-clamp
Screw-clamp
4
4
—
—
LP2K09004 ab
LP2K12004 ab
202.
232.
5
9
15
Screw-clamp
10
12
20
5
10
9
12
20
20
Coil voltage codes for DC contactors
Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price
adder $10.00 ($20.00 for mechanically interlocked contactors)
Volts DC
12
20
24
36
48
60
72
100
110
125
200
220
230
240
250
Code
JD
ZD
BD
CD
ED
ND
SD
KD
FD
GD
LD
MD
MPD
MUD
UD
Table 18.99:
DC–Low consumption operating coils (devices have built-in transient suppression)
4-Pole Mini Contactor
0.5
1.5
2
3
5
0.5
1.5
3
3
7.5
4-Pole Mechanically Interlocked Contactors
5
9
15
Screw-clamp
10
12
20
Screw-clamp
4
2
4
—
2
—
LP4K09004 ab
LP4K09008 ab
LP4K12004 ab
110.
116.
126.
LP5K09004
ab
LP5K12004 ab
238.
0.5
1.5
2
3
5
5
9
20
Screw-clamp
4
—
0.5
1.5
3
3
7.5
10
12
20
Screw-clamp
4
—
274.
Table 18.100: Coil voltages for DC contactors—Low consumption
a
b
Volts DC
12
24
48
72
Code
JW3
BW3
EW3
SW3
For TeSys K contactors with spring terminal clamps, add a “3” before the coil voltage code (ex. LC1K09103L7).
For TeSys K contactors with solder pin terminals, add a “5” before the coil voltage code (ex. LP4K06015JW3).
For TeSys K contactors with slip-on terminals, add a “7” before the coil voltage code (ex. LP2K090047BD).
Complete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7.
Overload Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-24
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-27
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-49
18-26
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® K Contactors and Accessories
Contactors and
Accessories
Refer to Catalog 8502CT9901
www.schneider-electric.us
Table 18.101: Instantaneous auxiliary contact blocks
Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors.
Auxiliary Contacts
Type of connection
LA1KN11
a
N.O.
2
—
1
4
Screw clamp
3
2
1
—
2
—
1
4
Slip-on 1 x .250" or 2 x .110"
3
2
1
—
Block of 4 contacts cannot be used with LP4K or LP5K contactors.
Catalog
Number
N.C.
—
2
1
—
1
2
3
4
—
2
1
—
1
2
3
4
$ Price
LA1KN20
LA1KN02
LA1KN11
LA1KN40 a
LA1KN31 a
LA1KN22 a
LA1KN13 a
LA1KN04 a
LA1KN207
LA1KN027
LA1KN117
LA1KN407 a
LA1KN317 a
LA1KN227 a
LA1KN137a
LA1KN047 a
14.20
14.20
14.20
27.30
27.30
27.30
27.30
27.30
14.20
14.20
14.20
27.30
27.30
27.30
27.30
27.30
Table 18.102: Electronic time delay auxiliary contact blocks
Note:
Note:
Note:
Note:
Timing Range
Voltage (V)
Type
(S)
24 to 48 Vac or Vdc
On-delay
1 to 30
110 to 240 Vac
On-delay
1 to 30
Relay outputs, with single pole double throw, 240 Vac/dc, 2 A max.
Maximum switching capacity 250 VA / 150 W
Operating temperature: -10 to + 60°C (14 to 140°F)
Reset time: 1.5 s during time delay, 0.5 after time delay
Contacts
SPDT
SPDT
Catalog
Number
LA2KT2E
LA2KT2U
$ Price
32.80
32.80
Table 18.103: Suppressor Module with incorporated LED indicator
Clip-on front mounting
$ Price
each
12 to 24 Vac and dc
Varistor
5
LA4KE1B b
9.80
32 to 48 Vac and dc
Varistor
5
LA4KE1E b
9.80
50 to 129 Vac and dc
Varistor
5
LA4KE1FC b
9.80
130 to 250 Vac and dc
Varistor
5
LA4KE1UG b
9.80
12 to 24 Vdc
Diode + Zener
5
LA4KC1B c
9.80
32 to 48 Vdc
Diode + Zener
5
LA4KC1E c
9.80
220 to 250 Vac
RC
5
LA4KA1U d
9.80
b
Protection by limitation of the transient voltage to 2 Uc maximum. Maximum reduction of the transient voltage peaks. Slight time delay on drop-out (1.1
to 1.5 times normal).
c
No overvoltage or oscillation frequency. Polarized component. Slight time delay on drop-out (1.1 to 1.5 times normal).
d
Protection by limitation of the transient voltage to 3 Uc maximum and limitation of the oscillation frequency. Slight time delay on drop-out
(1.2 times normal).
Voltage range
LA2KT2U
Type
Sold in
lots of
Catalog
Number
Table 18.104: Paralleling Links
Description
For 2 poles with screw-clamp terminals
For 4 poles with screw-clamp terminals
Sold in
lots of
4
2
Catalog
Number
LA9E01
LA9E02
$ Price
each
2.20
3.50
Table 18.105: Power Connectors
Description
Sold in
lots of
Catalog
Number
Set of 6 power connections for reversing
contactors with screw-clamp terminals
Set of 4 power connections for changeover
contactors with screw-clamp terminals
$ Price
each
100
LA9K0969
6.20
100
LA9K0970
6.20
Table 18.106: Marking strips
Description
Clips onto front of the contactor
Sold in
lots of
100
Catalog
Number
LA9D90
$ Price
each
.06
Table 18.107: Accessories for overload relays
Description
Terminal block for separate clip-on mounting of the overload relay onto 35 mm
omega rail (AM1DP200)
Type of Connection
Catalog Number
Screw-clamp
LA7K0064
$ Price
11.90
E164862
CCN NLDX
LR43364
Class 3211 04
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
18-27
18
LA1KN22
IEC CONTACTORS AND
STARTERS
Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors.
TeSys® U Simple Motor Starter
Motor Starters
Refer to Catalog 8502CT0201
www.schneider-electric.us
The TeSys U motor starter is integrated, simple to choose and to install, consisting of a control unit snapped in a power
base. TeSys U can be configured to fit specific applications as well. Optional accessories: reverser, current limiter,
predictive maintenance options and communication options.
To get details information about TeSys U, visit our web at www.us.schneider-electric.com/TeSysU.
1
Power Base
2
+
Function Modules
3
Control Unit
TeSys® U Motor Starter
=
Auxiliary Contacts
Selecting TeSys U Motor Starters in Three Steps
Table 18.108: Step 1. Select Power Base (Only two different bases up to 32 amps.)
18
Three Phase (HP max.)
Single Phase (HP max.)
Control
Connection
Max. Current
(Amps)
200/208 V
220/240 V
460 V
575/600 V
120 V
240 V
With screw
terminations
12
32
3
10
3
10
7.5
20
10
25
1.5
2
2
5
Self-Protected Power Base
Catalog
Number
LUB12
LUB32
$ Price
246.00
345.00
IEC CONTACTORS AND
STARTERS
Table 18.109: Step 2. Select Control Unit g
Standard
Advanced
Advanced
Advanced
3-phase
$ Price
3-phase
$ Price
single-phase
$ Price
3-phase
$ Price
Class 10 trip e
Class 10 trip e
Class 10 trip e
Class 20 trip e
0.15–0.6
LUCAX6••
120.00
LUCBX6••
150.00
LUCCX6••
150.00
LUCDX6••
150.00
120.00
LUCB1X••
150.00
LUCC1X••
150.00
LUCD1X••
150.00
0.3–1.4
LUCA1X••
1.25–5.0
LUCA05••
120.00
LUCB05••
150.00
LUCC05••
150.00
LUCD05••
150.00
3–12
LUCA12••
120.00
LUCB12••
150.00
LUCC12••
150.00
LUCD12••
150.00
120.00
LUCB18••
150.00
LUCC18••
150.00
LUCD18••
150.00
4.5–18 f
LUCA18••
8–32 f
LUCA32••
120.00
LUCB32••
150.00
LUCC32••
150.00
LUCD32••
150.00
e
Complete catalog number by adding appropriate code from voltage code table below. For example: LUCAX6FU.
f
Control units for 4.5–18 and 8–32 can be used ONLY with 32 amp rated power bases (LUB32 / LU2B32).
g
The control unit contains solid state overload relay and control power source for TeSys U. For more details on the different control units, their functions,
and placement on the power base, see 18-29
Setting Range
(Amps)
Power Base
Table 18.110: Voltage Codes
Volts
24
48–72
110–240
DC
BLh
—
—
AC
B
—
—
DC or AC
—
ESi
FU
h
DC voltage with range of 0.90 to 1.10 of nominal.
i
48–72 Vdc; 48 Vac
Table 18.111: Step 3. Select Auxiliary Contacts (optional)
Control Unit
Auxiliary Contact Blocks
Contact
Normal
Status
Terminals
Auxiliary Contact
Contact State for Each Modea
Contact
Indicates
Ready condition
Fault condition
Ready condition
Screw
Fault condition
Auxiliary Contact Function Modules
Screw
N.O.
N.C.
N.O.
N.O.
Screw
Pole state
2 N.O.
Screw
Pole state
1 N.O. and 1 N.C.
Off
Ready
Run
Short
Circuit
Trip
Overload
Trip
(Manual
Reset)
O
I
O
O
I
I
I
O
I
I
I
O
O
O
O
I
O
O
O
I
O
O
O
I
O
I
I
I
O
O
O
O
I
O
Screw
Pole state
2 N.C.
1
I
O
I
a
I–indicates closed contact; O–indicates open contact
b
Requires multifunction or advanced control unit plus fault differentiation module LUFDA10.
E164862
CCN NLDX
LR43364
Class 3211 08
18-28
Accessory
Current Limiter
Reverser
Line phase barrier
Multifunction Control Unit
Function modules
Communication modules
Soft Starter + TeSys U
Powerbus
Configuration and connection accessories
Quick Description
Increases the breaking capacity to 130kA @ 460 V
Stacked or side mounted
Required for use as a self-protected combination starter (UL508E)
Has functions for monitoring and predictive maintenance
Fault differentiation, Thermal overload, Motor load indication
Integrates into existing networks, major portocols are available
Use Altistart U01Soft Starter with TeSys U
Use TeSys U with a prewired system
PowerSuite software, busbar, external handle
Catalog
Number
$ Price
LUA1C11
LUA1C20
34.5
LUFN20
I
I
Overload
Trip
(Remote/
Auto
Reset)b
I
I
I
O
LUFN11
34.5
LUFN02
For details & selection, see pages:
18-30
18-30
18-30
18-30
18-30
18-31
18-32
18-31
18-31
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-29 to 18-31
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-50
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® U Simple Motor Starter
Control Units
Refer to Catalog 8502CT0201
www.schneider-electric.us
Table 18.112: Control Units and Functions
Standard
Advanced
LUCA
LUCB
Multifunction
LUCC
LUCD
LUCM
IEC CONTACTORS AND
STARTERS
Reference
Protection type
Class 10
Class 20
Class 5…30
Single Phase: LUCC Class 10 only
Protection functions
Short circuit
Over current
Thermal overload
Phase loss
Phase imbalance
Ground fault
Under load, long start, jam
Control functions
Manual reset
Automatic or local/remote reset
Fault differentiation
Thermal alarm
Motor load display
Fault history
Alarm Threshold adjustment
Tripping test
18
= built-in the control unit
= works with the related function modules (see Table 18.119 on page 30)
Power Base and plug-in accessories
Find below where to install the accessories to the power base. Only one accessory can be installed in each location.
b
e
j
m
b
Control Unit or
mMultifunction Control
Line Phase Barrier
Reverser Unit mounts under power base
Current Limiter attaches under power base
Multifunction Control Unit
Control Circuit
Contact Block
Auxiliary
Function or Communication Module
Auxiliary Contact Block
ej
Power Base (front view)
© 2009 Schneider Electric
All Rights Reserved
Side View
18-29
TeSys® U Simple Motor Starter
Accessories
Refer to Catalog 8502CT0201
www.schneider-electric.us
Table 18.113: Line Phase Barrier (optional) a
Catalog
Number
LU9SP0
Description
Line Phase Barrier
For use as a self protected combination starter, UL508E, incoming line phase barrier must be used.
a
See page 18-29 for placement on the power base.
$ Price
15.00
Table 18.114: Reverser b
Control
Connection
Three Phase
(HP max.)
Max. Current
(Amps)
200/208 V
Self-Protected
Starter Base
220/240 V
460 V
575 V
3
10
7.5
20
10
25
12
3
With screw terminations
32
10
b
See page 18-29 for placement on the power base.
c
Voltage code required.
Catalog
Number
LU2B12c
LU2B32c
$ Price
488.00
720.00
Select Control Unit Optionsef
Standard
Advanced
Advanced
3-phase
$ Price
3-phase
$ Price
single-phase
$ Price
Class 10 trip d
Class 10 trip d
Class 10 trip d
0.15–0.6
LUCAX6••
120.00
LUCBX6••
150.00
LUCCX6••
150.00
120.00
LUCB1X••
150.00
LUCC1X••
150.00
0.3–1.4
LUCA1X••
120.00
LUCB05••
150.00
LUCC05••
150.00
1.25–5.0
LUCA05••
3–12
LUCA12••
120.00
LUCB12••
150.00
LUCC12••
150.00
120.00
LUCB18••
150.00
LUCC18••
150.00
4.5–18 d
LUCA18••
8–32 d
LUCA32••
120.00
LUCB32••
150.00
LUCC32••
150.00
d
Complete catalog number by adding appropriate code from voltage code table below. For example: LUCAX6FU.
e
Control units for 4.5–18 and 8–32 can be used ONLY with 32 amp rated power bases (LUB32 / LU2B32).
f
The control unit contains solid state overload relay and control power source for TeSys U.
For more details on the different control units, their functions, and placement on the power base see page 18-29.
Setting Range
(Amps)
18
Reverser Unit assembled
under the Power Base
IEC CONTACTORS AND
STARTERS
Advanced
3-phase
Class 20 trip d
$ Price
LUCDX6••
LUCD1X••
LUCD05••
LUCD12••
LUCD18••
LUCD32••
150.00
150.00
150.00
150.00
150.00
150.00
Catalog
Number
$ Price
LUALB1
171.00
LUALF1
78.00
Table 18.115: Voltage Codes
g
h
i
Volts
24
48–72
110–240
DC
BLgb
—
—
AC
B
—
—
DC or AC
—
ESj
FU
Voltage code to use for a power base with a communication module.
DC voltage with range of 0.90 to 1.10 of nominal.
48–72 Vdc; 48 Vac
Table 18.116: Current Limiter jk
Accessory
Control Unit
Multifunction
Limiter cartridge
Replacement cartridge for LUALB1
Parallel wiring
130 kA at 460 V
60 kA at 575 V
130 kA at 460 V
65 kA at 575 V
Mounting
Direct mounting to LUB•
and LU2B•
—
Increases the breaking capacity of the motor starter.
See page 18-29 for placement on the power base.
Table 18.117: Control Unit Multifunction lm
l
m
Setting Range
Multifunction programmable
(Amps)
0.15–0.6
LUCMX6BL
0.3–1.4
LUCM1XBL
1.25–5.0
LUCM05BL
3–12
LUCM12BL
4.5–18
LUCM18BL
8–32
LUCM32BL
Offers motor management system capabilities. For more details see the LUCM on page 18-31.
See page 18-29 for placement on the power base.
$ Price
615.00
Table 18.118: Function Modules no
Module
Alarm differentiation
Technical Data
Current limiter/isolator
j
k
Current Limiter and its
Cartridge
Application
Additional current limiting aspects
for the starter
Fault differentiation with
manual reset
(thermal overload)
Fault differentiation with
auto reset
Thermal overload
pre-alarm
Description
For use with:
Provides indication between an overload trip Advanced control units only
and a short circuit trip.
Signals when the motor current reaches 1.05
of the full load setting on the control unit.
Provides a signal proportional to the average
currents in the three phases divided by the full
Motor load indication
load current setting of the control unit. The
output corresponds to a load status of 0–2
times the full load setting of the control unit.
Provides a convenient way to reduce control
wiring and allow for connecting starters to a
Parallel wiring
communications network by providing 24 Vdc
for the starters.
n
Offers customization for specific application requirements.
o
See page 18-29 for placement on the power base.
Operation
Requirements
24–250 Vac or Vdc
(power from control unit)
Advanced control units only
24–250 Vac or Vdc
(power from control unit)
Advanced or multi-function
control units
4–20 mA
(requires separate 24 Vdc power
supply)
Advanced or multi-function
control units(24 Vdc only) and LU9G02
LU9BN11C or LU9MRC pre- splitter box and PLC network
wired connector
Catalog
Number
$ Price
LUFDH20
156.00
LUFDA10
156.00
LUFW10
156.00
LUFV2
188.00
LUFC00
57.00
Motor load indicator
18-30
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® U Simple Motor Starter
Accessories
Refer to Catalog 8502CT0201
www.schneider-electric.us
AS-Interface
Modbus
DeviceNet
Profibus
Description
Catalog
Number
$ Price
ASILUFC5
188.00
ASILUFC51
188.00
LULC033
218.00
LULC15
218.00
LULC08
218.00
LULC14
218.00
LULC07
218.00
LULC09
218.00
Configuration and Connection Accessories
CANopen
\
Table 18.120: Control Circuit Accessories f
Accessory
Control circuit contact block
Through-the-door operating
mechanism
Application
Switches control circuit power via LUB•
handle
(NEC430-74 compliance)
Use in enclosures 7.5 to
20 inches deep. Use with LUB• only.
Technical Data
5 amp at 600 Vac
5 amp at 250 Vdc
Use with electronic or triac output
controllers
See page 29 for placement on the power base.
r
Side mounting to LUB•
and LU2B• only
—
Black / Blue
Red / Yellow
Operating handle (NEMA 12) Use with LU9AP00
Control circuit filters
Mounting
—
Enclosure door
Enclosure door
Up to 150 VAC max. Directly to coil terminals
Non-reversing
Reversing
Catalog
Number
$ Price
LUA8E20
71.00
LU9AP00
125.00
LU9AP11
LU9AP12
LUA4F11
LUA4F12
31.50
31.50
39.30
39.30
Table 18.121: PowerSuite Configuration Software and Accessories
Itema
Catalog Number
PowerSuite software
VW3A8104
PC connection kit
VW3A8106
Pocket PC connection kit
VW3A8111
a
For complete details on all components included with each item, refer to Catalog #8502CT0201.
b
Items under Discount Schedule CP4C.
$ Priceb
225.00
113.00
143.00
Powerbus
Table 18.122: GV2 Cabling Accessories—Bus Bars
Description
Application
For feeding 2 GV2 starters or TeSys U
3-Pole, 63 A Bus Bar
For feeding 3 GV2 starters or TeSys U
For feeding 4 GV2 starters or TeSys U
For feeding 5 GV2 starters or TeSys U
Pitch
45
54
72
45
54
45
54
72
54
Standard Pack
1
1
1
1
1
1
1
1
1
Catalog Number
GV2G245
GV2G254
GV2G272
GV2G345
GV2G354
GV2G445
GV2G454
GV2G472
GV2G554
$ Price Each
23.30
23.30
23.30
28.70
28.70
34.20
34.20
34.20
34.20
Additional accessories and components are available, including:
•
•
•
•
Mounting accessories
Gateways
Cabling accessories
Magelis® remote display unit
For the complete line of TeSys U-Line motor starter accessories and all technical details (specifications,
wiring diagrams, etc.) pertaining to the product line, refer to Catalog 8502CT0201.
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
18-31
18
Operation
For use with:
Requirements
Advanced
or
multi-function
Allows the TeSys U starter to be connected control units (24 Vdc only)
Requires separate 24 Vdc
AS-Interface
directly to the network using AS-Interface
supply and AS-Interface
Communication
and LU9BN11C or LU9MRC power
protocols.
network
pre-wired connector
or multi-function Requires separate 24 Vdc
Allows the TeSys U starter to be connected Advanced
AS-Interface V2
units (24 Vdc only)
directly to the network using AS-Interface V2 control
supply and AS-Interface
Communication
and
LU9BN11C
or LU9MRC power
protocols.
V2 network
pre-wired connector
or multi-function
the TeSys U starter to be connected Advanced
Modbus® Communication Allows
control units (24 Vdc only)
Requires separate 24 Vdc
directly to the network using
Protocol
and
LU9BN11C
or LU9MRC power supply
Modbus protocols.
pre-wired connector
Advanced or multi-function
Advantys™ STB
Allows the TeSys U starter to be connected to control units (24 Vdc only)
Requires separate 24 Vdc
Communication
the network using the Advantsys STB protocol and LU9BN11L or LU9MRL power supply
pre-wired connector
Advanced or multi-function
CANopen
Allows the TeSys U starter to be connected to control units (24 Vdc only)
Requires separate 24 Vdc
Communication
the network using the Can Open protocol
and LU9BN11L or LU9MRL power supply
pre-wired connector
Advanced or multi-function
the TeSys Ustarter to be connected to control units (24 Vdc only)
Requires separate 24 Vdc
Beckoff Communication Allows
the network using the Beckoff protocol
and LU9BN11L or LU9MRL power supply
pre-wired connector
Advanced or multi-function
the TeSys Ustarter to be connected to control units (24 Vdc only)
Requires separate 24 Vdc
Profibus Communication Allows
the network using the Profibus protocol
and LU9BN11L or LU9MRL power supply
pre-wired connector
Advanced or multi-function
DeviceNet®
Allows the TeSys U starter to be connected to control units (24 Vdc only)
Requires separate 24 Vdc
Communication
the network using the Device Net protocol
and LU9BN11L or LU9MRL power supply
pre-wired connector
p
Communication capabilities can be integrated into existing automation architecture via a variety of protocols.
q
See 18-29 for placement on the power base.
Module
IEC CONTACTORS AND
STARTERS
Table 18.119: Communication Modules de
ATSU01 Altistart® Drive and TeSys® U Simple Motor Starter
Soft Starters
Refer to Catalog 8502CT9901
www.schneider-electric.us
Altistart Drive and TeSys U Motor Starter
Table 18.123: Soft Start/Soft Stop Unit for 0.75 to 15 kW Motors (Can be combined with the TeSys U Starter)
Motor
Starter
Motor Power (1)
230 V
460 V
HP
HP
Nominal Current
Part Number
$ Price
ATSU01N206LT
133.00
ATSU01N209LT
ATSU01N212LT
152.00
175.00
ATSU01N222LT
219.00
ATSU01N232LT
300.00
A
3-Phase supply voltage: 200 ... 480 V 50/60 Hz
1
2
6
1.5
3
2
5
9
3
7.5
12
5
10
22
7.5
15
10
20
32
a
Standard motor power ratings, HP power ratings indicated according to standard UL 508.
Table 18.124: Accessories
18
Description
Power connector between
ATSU 01N2••LT
and TeSys U
Used for Starter
Reference
$ Price
ATSU01N2••T
VW3G4104
10.00
Table 18.125: TeSys U Starter and Soft Start Unit Combinations
IEC CONTACTORS AND
STARTERS
Motor Power
TeSys U
Voltage
200 V
ATSU01••
b
Soft Starter
460 V
Power Base
Control Unit b
HP
HP
1
2
ATSU01N206LT
LUC•05BL
1.5
3
ATSU01N206LT
LUC•12BL
2
5
ATSU01N209LT
LUC•12BL
LUB 12
3
—
ATSU01N212LT
LUC•12BL
—
7.5
ATSU01N212LT
LUC •18BL
5
10
ATSU01N222LT
LUC•18BL
7.5
15
ATSU01N222LT
LUC•32BL
LUB 32
10
20
ATSU01N232LT
LUC•32BL
Depending on the configuration of the chosen TeSys U starter, replace the • with “A” for standard, “B” for advanced, and “M” for multifunction. See
page 18-28 for a complete list of available control units. Control voltage must be 24 Vdc.
E231693
CCN NLDX
LR96921
Class 3211 06
18-32
CP1G
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® GV2 and GV3 Manual Starter and Protector
Starters
Refer to Catalog 2520CT0001
www.schneider-electric.us
The GV family of products are 3-pole, horsepower rated, UL 508 listed, manual starters. They include a manual
disconnect, class 10 ambient-compensated thermal overload relay, and an instantaneous magnetic trip mechanism in
one compact unit.
Any GV manual starter can be used alone for local manual control of a motor with individual full-load currents up to 220
amps. The GV family of products may also be used in group motor installations in accordance with National Electric
Code article 430-53. Group motor installations give you greater panel density for smaller size and require fewer parts
and less wiring necessary for installation when compared to conventional panel designs.
The GV2P and GV3P products also have an additional UL 508 type E rating as a stand alone self-protected manual
combination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7 for the GV2P
or part number GV3G66 for the GV3P. The GV2P and the GV3P self-protected manual combination starter may also
be combined with specific size contactors from the LC1D product family for a UL 508 Type F combination starter
construction. These products have UL-listed short circuit current rating from 10–100 KA depending on application size
and voltage. See www.us.telemecanique.com for more information.
How to Order
GV2ME
To order the basic motor starter, select the model number (GV2ME••, GV2P••, or GV3P••) with the appropriate thermal
setting from the table below. The thermal trip range and setting should be determined from the motor nameplate fullload current.
Table 18.126:
Group Motor
Applications
3Ø
GV2/3M push button
GV2/3P rotary handle
115 V
230 V
200 V
230 V
460 V
575 V
Max. Fuse or
Catalog
Catalog
$ Price
hp
hp
hp
hp
hp
hp
Circuit Breaker
Number
Number
0.11–0.16
—
—
—
—
—
—
450 A
GV2ME01a
159.
GV2P01
0.16–0.25
—
—
—
—
—
—
450 A
GV2ME02a
159.
GV2P02
0.25–0.40
—
—
—
—
—
—
450 A
GV2ME03a
159.
GV2P03
0.40–0.63
—
—
—
—
—
—
450 A
GV2ME04a
180.
GV2P04
0.63–1
—
—
—
—
0.5
0.5
450 A
GV2ME05a
180.
GV2P05
1–1.6
—
0.1
—
—
0.75
1
450 A
GV2ME06a
180.
GV2P06
1.6–2.5
—
0.667
0.5
1
1.5
450 A
GV2ME07a
180.
GV2P07
0.5
2.5–4
1/8
0.333
0.75
1
2
3
450 A
GV2ME08a
180.
GV2P08
4–6.3
1/4
0.5
1.5
1.5
3
5
450 A
GV2ME10a
180.
GV2P10
6–10
0.5
1.5
2
3
5
7.5
450 A
GV2ME14a
180.
GV2P14
9–14
0.75
2
3
3
10
10
450 A
GV2ME16a
224.
GV2P16
13–18
1
3
5
5
10
15
450 A
GV2ME20a
224.
GV2P20
17–23
1.5
3
5
7.5
15
20
450 A
GV2ME21a
224.
GV2P21
20–25
2
3
5
7.5
15
20
450 A
GV2ME22a
224.
GV2P22
24–32
2
5
10
10
20
30
450 A
GV2ME32
224.
GV2P32
9–13
0.5
1.5
3
3
7.5
10
—
—
GV3P13
New!
12–18
0.75
2
5
5
7.5
10
—
—
GV3P18
17–25
1.5
3
7.5
7.5
15
20
—
—
GV3P25
23–32
2
3
10
7.5
20
25
—
—
GV3P32
30–40
3
5
10
10
25
30
—
—
GV3P40
37–50
3
7.5
15
10
30
40
—
—
GV3P50
48–65
3
10
20
15
40
50
—
—
GV3P65
a
For spring terminals add 3 to the catalog number, for example, GV2ME013. GV2ME32 is not available with spring terminals.
$ Price
212.
212.
212.
233.
233.
233.
233.
233.
233.
233.
278.
278.
278.
278.
278.
404.
404.
404.
404.
504.
504.
504.
Table 18.127:
Maximum Horsepower Ratings
GV3P
Thermal
Setting
(A)
12–20
15–25
25–40
30–50
48–80
60–100
90–150
132–220
GV7RE20
1Ø
3Ø
Toggle Operator
115 V
hp
230 V
hp
200 V
hp
230 V
hp
460 V
hp
575 V
hp
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
5
7.5
10
15
30
30
50
75
10
15
30
30
60
75
100
150
15
20
30
40
75
100
150
200
Standard Interrupt
Catalog
Number
GV7RE20
GV7RE25
GV7RE40
GV7RE50
GV7RE80
GV7RE100
GV7RE150
GV7RE220
$ Price
417.
417.
417.
417.
417.
456.
502.
502.
High Interrupt
Catalog
Number
GV7RS20
GV7RS25
GV7RS40
GV7RS50
GV7RS80
GV7RS100
GV7RS150
GV7RS220
$ Price
813.
813.
813.
813.
813.
891.
978.
978.
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-36
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-34 to 18-35
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55
E164864
CCN NLRV
LR81630
Class 3211 05
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
18-33
IEC CONTACTORS AND
STARTERS
GV2P21 with
GV2GH7 installed
1Ø
18
Maximum Horsepower Ratings
Thermal
Setting
(A)
TeSys® GV2 and GV3 Manual Starters and Protectors
Starters Accessories
Refer to Catalog 2520CT0001
www.schneider-electric.us
Table 18.128: Voltage Trips
Only one trip or fault signaling contact can be installed per GV2/GV3 device.
Characteristics
Voltage
Frequency
Catalog Numbera
$ Price
50 Hz
GVA•025
24 V
60 Hz
GVA•026
50 Hz
GVA•055
48 V
60 Hz
GVA•056
100–110 V
50/60 Hz
GVA•107
50 Hz
GVA•115
110–115 V
60 Hz
GVA•116
120–127 V
50 Hz
GVA•125
127 V
60 Hz
GVA•115
Undervoltage or
200 V
50 Hz
GVA•207
Voltage trips
Shunt trip
200–220 V
60 Hz
GVA•207
81.00
GV2 & GV3P
(external mount,
50 Hz
GVA•225
1 block right side only)
220–240 V
60 Hz
GVA•226
50 Hz
GVA•385
380–400 V
60 Hz
GVA•386
415–440 V
50 Hz
GVA•415
415 V
60 Hz
GVA•416
440 V
60 Hz
GVA•385
480 V
60 Hz
GVA•415
500 V
50 Hz
GVA•505
600 V
60 Hz
a
To order an under voltage trip: replace the bullet ( •) with a U, example: GVAU025. To order a shunt trip: replace the bullet ( •) with an S, example:
GVAS025.
Description
GVAU116
18
IEC CONTACTORS AND
STARTERS
Table 18.129: Auxiliary Contact Blocks
Description
GVAE11
Instantaneous auxiliary contacts
GV2 + GV3P
Fault signaling contact +
instantaneous auxiliary contact
GV2 + GV3P
Mounting
Location
Max. No. of
Blocks
Frontbg
1
Left Hand Side
2
Left Hand Sided
1
Contact Type
Sold in lots of
Catalog Number
N.O. or N.C.c
N.O. + N.C.
N.O. + N.O.
N.O. + N.C.
N.O. + N.O.
N.O. (fault) + N.O.
N.O. (fault) + N.C.
N.C. (fault) + N.O.
N.C. (fault) + N.C.
1
10
1
1
1
1
1
1
1
GVAE1
GVAE11e
GVAE20e
GVAN11e
GVAN20e
GVAD1010
GVAD1001
GVAD0110
GVAD0101
21.80
35.70
35.70
35.70
35.70
54.00
54.00
54.00
54.00
GVAM11
35.70
Short circuit signaling contact
Left Hand Side
1
SPDT
1
GV2 + GV3P
Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.
Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.
The GVAD is always mounted next to the starter.
For spring terminals add 3 to the catalog number. Example: GVAE113
One trip or one fault signaling can be fitted per GV3.
Cannot be used with GV2GH7 insulator.
$ Price
b
c
d
e
f
g
Table 18.130: Voltage Trips–Technical Data (GV2AU, GV2AS)
Rated Voltage–660 Vac
h
Model
Inrush
Sealed
Pick-Up Voltage
GVAU
12 VA / 8 W
3.5 VA / 1.1 W
0.8 to 1.1
GVAS
14 VA / 10.5 W
5 VA / 1.6 W
0.7 to 1.1
From the loss of voltage at the trip terminals to the opening of the starter contacts.
Drop-Out Voltage
0.35 to 0.7
0.2 to 0.75
Operating Timeh
10 to 15 ms
10 to 15 ms
GVAD0101
Table 18.131: GV3P Accessories New!
Description
Set of 3-pole 115 A busbars
(tap-offs: 2, pitch: 64 mm)
Set of 3-pole 115 A busbars
(tap-offs: 3, pitch: 64 mm)
Cover “Larger Spacing” UL 508 type E
(Only one cover required on supply side)
IP 20 cover
(Two covers required per starter)
Padlocking device
For use with up to 4 padlocks (not supplied)
Ø 6 mm shank maximum
For GV3P
Catalog Number
GV3P••
GV3G264
$ Price
25.00
GV3P••
GV3G364
45.00
GV3P••
GV3G66
18.00
GV3P••
LAD96570
12.00
GV3P••
GV3P•••
GV2V03
15.00
GVAN11
18-34
CP10
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® GV7 Manual Starters and Protectors
Starters Accessories
Refer to Catalog 2520CT0001
www.schneider-electric.us
Table 18.132: Auxiliary contact blocks (auxiliary contact functions depends on location inside the device)
Description
Standard
Instantaneous
Trip Indication
Fault Indication
Low Level
Instantaneous
Trip Indication
Fault Indication
Max. No. of Blocks
Contact Type
Catalog Number
$ Price
Inside Device
2 per device
1 per device
1 per device
N.O. + N.C.
N.O. + N.C.
N.O. + N.C.
GV7AE11
35.70
Inside Device
2 per device
1 per device
1 per device
N.O. + N.C.
N.O. + N.C.
N.O. + N.C.
GV7AB11
35.70
Table 18.133: Voltage Trips
Mounting Location
Max. No. of Blocks
Undervoltage Trip
Inside Device
1 per device
Shunt Trip
Inside Device
1 per device
Fault Indication
Inside Device
1 per device
Voltage
48 Vac
110–130 Vac
200–240 Vac
380–440/480 Vac
525 Vac
48 Vac
110–130 Vac
200–240 Vac
380–440/480 Vac
525 Vac
24–130
110–415
50 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50 Hz
50 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50 Hz
Catalog Number
GV7AU055
GV7AU107
GV7AU207
GV7AU387
GV7AU525
GV7AS055
GV7AS107
GV7AS207
GV7AS387
GV7AS525
GV7AD111
GV7AD112
$ Price
64.00
64.00
72.00
Table 18.134: Wiring Accessories
Description
GV7RE20
Box Lugs
Phase Barriers, Bus Bars & Shrouds
Terminal Extension Kit
Terminal Shroud Kit
Phase Barriers
Insulating Barriers
Busbars and Covers
GV7AD111
Application
Sold in lots of 3 for GV7R•20–150i
Sold in lots of 3 for GV7R•220i
Increases center distance between phases to 45 mm
Covers terminal connections for touch safe protection
Provides maximum phase separation at connection points
Provides insulation between connectors and backplate
Connect to LC1F115–185 contactor
Connect to LC1F225–265 contactor
Operating Handles and Accessories
Black rotary operating handle with black legend plate (mounts directly on device)
Red rotary operating handle with yellow legend plate (mounts directly on device)
Conversion accessory to mount device directly on panel door
Black rotary operating handle with black legend plate and extension kit (185–600 mm)
Red rotary operating handle with yellow legend plate and extension kit (185–600 mm)
Padlocking device for toggle handle (max. 38 mm padlocks)
i
Wire size: GV7AC021—#14–3/0; GV7AC022—#14–350 kcmil.
Catalog Number
GV7AC021
GV7AC022
$ Price
19.70 each
24.90 each
GV7AC03
GV7AC01
GV7AC04
GV7AC05
GV7AC06
GV7AC07
46.70
41.90
31.10
24.90
46.70
46.70
GV7AP03
GV7AP04
GV7AP05
GV7AP01
GV7AP02
GV7V01
86.00
86.00
14.00
102.00
102.00
14.00
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55
GV7AS055
GV7AP03
© 2009 Schneider Electric
All Rights Reserved
GV7AC021
GV7V01
GV7AE11
I11
Discount
Schedule
18-35
IEC CONTACTORS AND
STARTERS
Description
18
GV7AC01
Mounting Location
TeSys® Manual Starters and Protectors LS1 Fuseholders
Starters Accessories
Refer to Catalog 2502CT0001
www.schneider-electric.us
•
•
•
•
•
•
45 mm wide (same dimensions as GV2ME)
Available with screw clamp and spring type terminals
Mounts directly to LC1D09–D32 contactors (with use of GV2AF3 or GV2AF4)
Meets application needs for fusible starter
Uses GV2AE instantaneous contact blocks to open control circuits
DIN rail mounted
Table 18.135:
Description
Dimensions
Fuse Type
IN
mm
Spring terminals, 3-pole
CC, KTK-R
0.41 x 1.5
10.3 x 38
Screw clamp terminals, 3-pole
CC, KTK-R
0.41 x 1.5
10.3 x 38
Spring terminals, 3-pole
aM, gG
0.39 x 1.5
10 x 38
Screw clamp terminals, 3-pole
aM, gG
0.39 x 1.5
10 x 38
Auxiliary main pole adder
aM, gG
0.39 x 1.5
10 x 38
a
Can be mounted on left-hand or right-hand side of the 3-pole LS1D32 block.
Use In
Catalog Number
US Markets
US Markets
European Markets
European Markets
European Markets
LS1D303
LS1D30
LS1D323
LS1D32
LA8D324a
$ Price
86.
86.
101.
86.
65.
Table 18.136: Specifications
Type
Max. voltage
Max. current
18
LS1D30, LS1D303
LS1D32, LS1D323, LS1DT32
600 V 3 Phase
30 A
IEC 60947-1, 60947-2, 60947-4-1, EN60204, BS4841, UL 508,
CSA 222.2 No. 14, NFC 63-650, 63-120, 79-130, VDE 0113, 0660
UL, CSA
BV
“TH”
“TH”
o
-58 to 158 F
(-50 to +70o C)
Conforming to standards
LS1D30
IEC CONTACTORS AND
STARTERS
Product approvals
Protective treatment
Ambient air temperature
—operation
Wiring
Number of conductors and cross sectional area (c.s.a.)
Max.
AWG (2–6 mm2)
Solid cable
Flexible cable without cable end
Flexible cable with cable end
Resistance to mechanical impact conforming to IEC 60947-1 §7-1-6
Tightening torque
Sensitivity to phase failure
2–#8
2–#8 AWG (2–6 mm2)
2–#10 AWG (2–4 mm2)
0.5 J
15 in-lb (1.7 N•m)
No
Min.
mm2)
2–#16 (2–1
2–#14 (2–1 mm2)
2–#16 AWB (2–1 mm2)
Table 18.137: Specifications
Operating Positions:
File E164864
CNN NLRV
30
90
90
30
File LR81630
Class 3211 05
Rated voltage—600 V
Rated thermal current—25 A (GV2), 63 A (GV3)
Mechanical life:
GV2:
18-36
100,000 operations
I11
Discount
Schedule
Shock resistance—30 g (conforming to IEC 600 68-2-27)
Vibration resistance—5 g (5 to 150 Hz) (IEC 600 68-2-26)
Ambient temperature:
-40 to 176oF (-40 to +80oC) for storage
-4 to 140oF (-20 to +60oC) open operation
-4 to 104oF (-20 to +40oC) enclosed operation
Maximum operating life—25 operations per hour
Operating current of magnetic trip is approximately 13 times maximum
thermal trip (non-adjustable setting)
© 2009 Schneider Electric
All Rights Reserved
TeSys® GV2 Manual Starters and Protectors
Starters Accessories
Refer to Catalog 2520CT0001
www.schneider-electric.us
Table 18.138: GV2 Mounting Accessories
Description
7.5 mm compensation plate
Mounting plate
For mounting GV2ME or GV2P and contactor LC1D09 thru D32
Common mounting plate
Adapter plate
Combination block
GV2GH7
Standard Catalog Number
Pack b
Application
For GV2 plus any 3-pole LC1D09 thru LC1D25 contactor.
(supplied with GV1G02 connector)
For screw mounting of GV2M
Interconnect for GV2 plus any 3-pole LC1K or LP1K contactor
Interconnect GV2 and LC1D09 thru D32
Interconnect GV2 and LC1D09 thru D32 mounted on LAD31
To allow mounting of GV2M and GV2P on a common bus bar
1
10
10
10
10
10
10
10
GK2AF01
GV2AF02
GV2AF01
GV2AF3
GV2AF4
GV1F03
LAD31
LAD311
$ Price Each
21.60
7.10
14.00
3.20
3.20
5.40
6.20
12.30
Table 18.139: GV2 Cabling Accessories—Bus Bars
Description
Application
Pitch
45
54
72
45
54
45
54
72
54
For feeding 2 GV2 starters
3-Pole, 63 A Bus Bar
For feeding 3 GV2 starters
For feeding 4 GV2 starters
For feeding 5 GV2 starters
Standard Pack b
1
1
1
1
1
1
1
1
1
Catalog Number
GV2G245
GV2G254
GV2G272
GV2G345
GV2G354
GV2G445
GV2G454
GV2G472
GV2G554
$ Price Each
23.30
23.30
23.30
28.70
28.70
34.20
34.20
34.20
34.20
Description
Terminal blocks
LAD31
Application
Top feed for use with bus bars
Bottom feed, to be used with bus bars; can be fitted with GV1L3
current limiter
To cover unused bus bar outlets
For connecting a GV2 to an LC1D09 thru D25 contactor
Protective end cover
3-pole flexible connector
Conduit adapter (1•2" NPT)
Incoming line insulator
For GV2P when used in UL 508 Type E applicationsa
a
Cannot be used with front-mounted auxiliary contact block.
Standard Pack b Catalog Number
1
GV1G09
$ Price Each
34.20
1
GV2G05
34.20
5
10
1
10
GV1G10
GV1G02
GV2AK1
GV2GH7
3.60
14.30
16.20
15.00
Table 18.141: GV2 Other Accessories
Through-Door operator - GV2P
Application
Front mount, 3-pole visible isolation on incoming side of GV2P
Increases interrupt capacity when attached to GV2M
For operating GV2P through enclosure door (red handle, yellow
legend plate) For NEMA 1 use. IP54
Standard Pack b Catalog Number
1
GV2AK00
1
GV1L3
1
GV2AP02
$ Price Each
71.40
117.00
135.00
18
Description
Visible isolation block - GV2P
Current limiter - GV2M
Table 18.142: GV2 Enclosures
Description
Mounting
Rating
NEMA 1, IP41
IP55
NEMA 1, IP41
IP55
NEMA 1, IP41
IP55
Surface mount
Enclosures for GV2M
with or without accessories
(maximum of 1 accessory
Flush mount
on right and left)
Enclosures are not UL or CSA listed. Flush mount reduced width
(max. of 1 accessory on right)
Catalog Number
GV2MC01
GV2MC02
GV2MP01
GV2MP02
GV2MP03
GV2MP04
$ Price Each
54.00
78.00
31.10
54.00
27.90
49.70
Table 18.143: GV2 Enclosures Accessories
Description
Padlocking device for GV2M (when
padlocked, starter is automatically in Off
position)
Type
Spring return
LAD311
Key release (Ronis key no. 455)
Turn to Release
Latching / Padlockable Turn to Release
Sealing kit
For enclosures GV2MC01 and GV2MP01
110 V
Green
110 V
Red
110 V
Orange
110 V
White
220/240 V
Green
220/240 V
Red
Pilot Light (neon)
220/240 V
Orange
220/240 V
White
380/440 V
Green
380/440 V
Red
380/440 V
Orange
380/440 V
White
b
Orders must specify multiples of quantities listed.
c
Supplied with IP55 sealing kit.
Mushroom head stop push button
(40 mm, red) c
Latching
Standard Packb Catalog Number
$ Price Each
1
GV2V01
26.90
1
1
1
1
10
10
10
10
10
10
10
10
10
10
10
10
10
GV2K011
GV2K021
GV2K031
GV2K04
GV2E01
GV2SN13
GV2SN14
GV2SN15
GV2SN17
GV2SN23
GV2SN24
GV2SN25
GV2SN27
GV2SN33
GV2SN34
GV2SN35
GV2SN37
35.90
104.00
52.00
117.00
18.00
26.90
GV2AF3 / GV2AF4
© 2009 Schneider Electric
All Rights Reserved
I11
Discount
Schedule
IEC CONTACTORS AND
STARTERS
Table 18.140: GV2 Other Cabling Accessories
18-37
Wiring, Communications,
and Busbar System
TeSys® Contactors and Motor Protectors with Spring Terminals
Refer to Catalog 8502CT0101
www.schneider-electric.us
Table 18.144: Splitter Boxes
A total of up to eight starters is permissible after extensions. Use multiple quantities of the same catalog number to
create the desired line-up.
Description
APP2R4H1
Type of Control-command
Connection on
Control System Side
50 A power splitter box
No. of I/O per
Starter
—
$ Price
LAD322
LAD324
APP2R4H1
APP2R4H2
APP2R2E
APP2R4E
APP2R2AS
APP2R4AS
52.00
93.00
124.00
124.00
124.00
124.00
124.00
124.00
1I/1O
2I/1O
Via module APP1C••• a
—
2I/1O
1I/1O
AS-i
a
Catalog Number
2
4
4
4
2
4
2
4
—
1 x HE10 8I/8O
1 x HE10 16I and 1 x HE10 8O
50 A power and control splitter box
No. of Starters
per Unit
Connection to an APP1C••• module via APP2CX adaptor (LAD35).
Table 18.145: Power Connection Components for One Starter
LAD35
Description
Kit Consists of:
Catalog Number
Assembly and power connection kit
One LAD31 plate for GV2ME and two LAD34 power connection modules
LAD351
Reversing kit b
One set of bus bars and one mechanical interlock
LAD32
b
To create a TeSys D reverser, use two LC1D contactors, one assembly and power connection kit, and one reversing kit.
$ Price
21.00
20.70
18
Table 18.146: Power Connection Accessories for One Starter
Description
IEC CONTACTORS AND
STARTERS
Upstream terminal block (50 A max)
Downstream terminal block (50 A max)
LAD3B
Use
Catalog Number
Power supply for one or two power splitter boxes
Connection of motor cables
LAD3B
LAD331
$ Price
83.00
5.00
Table 18.147: Control Connection Module for One Starter
Description
Control connection module
(integrating contact block GVAE20)
LAD33
Max. Connection
Cross-Section
16 mm2 (6 AWG)
6 mm2 (10 AWG)
c
d
D-Line
Coil Voltage
12–240 Vac or
24–125 Vdc
24–48 Vdc
Type of Coil Control
Relay
Electromechanical c
Without relay d
Type of Starter
Catalog Number
Non-reversing
Reversing
Non-reversing
Reversing
APP2D1
APP2D2
APP2D1D
APP2D2D
$ Price
41.40
72.00
31.10
31.10
Relay supplied mounted on the front panel of the control connection.
The use of TeSys D low consumption contactors is recommended.
Table 18.148: Spare or Replacement Parts
Description
Type of Control-command
Connection on Control
System Side
No. of I/O
per Starter
Plate for mounting a GV2ME manual starter
—
—
Power connection module
—
1 x HE10 8I/8O
1 x HE10 16I and 1 x HE10 8O
—
1I/1O
2I/1O
Control-command splitter box (single, for
mounting on a power splitter box)
Per module APP1C••• e
AS-Interface
Replacement electromechanical relay (for control connection module)
e
Connection to an APP1C••• module via APP2CX adaptor (LAD35).
—
2I/1O
1I/1O
—
No. of
Starters
Sold in
Lots of
Catalog Number
1
1
1
4
4
2
4
2
4
1
10
10
10
1
1
1
1
1
1
10
LAD31
LAD311
LAD341
APP2R4H3
APP2R4H4
APP2R2C
APP2R4C
APP2R2A
APP2R4A
APP2ER
$ Price
6.20
12.30
7.50
11.30
11.30
11.30
11.30
11.30
11.30
7.50
APP2D1•
18-38
I11
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
TeSys® AK5 Panel Busbar System
Busbar Accessories
Refer to Catalog 8502CT0101
www.schneider-electric.us
The AK5 pre-fabricated bus bar system provides a quick and easy method of mounting control devices. All components
are finger safe, UL Listed, CSA approved and CE marked. Although the AK5 system can be screw mounted onto any
type of support, it must be mounted on the AM1DL201 DIN rail when component mounting plates incorporating a tapoff are used. When using tap-offs, the nominal operating current of the bus bar (160 Amperes @ 35o) must not be
exceeded.
Table 18.149: 160 Ampere Three Phase Busbar System
Maximum number of mounting plates
Tap-off
IN
AK5JB143
1.42
Standard Width Plate
mm
IN
36
2.13
Extension Plate
mm
IN
54
2.80
Length
Catalog Number
$ Price
mm
IN
mm
6
4
2
71
13.39
344
AK5JB143
210.00
9
6
3
17.64
452
AK5JB144
266.00
12
8
4
21.85
560
AK5JB145
286.00
15
10
5
26.05
668
AK5JB146
345.00
24
16
8
38.69
992
AK5JB149
393.00
27
18
9
42.90
1100
AK5JB1410
540.00
AK5PA231
mm
Thermal
Current Amperes
Application
Catalog Number
$ Price
2.13
54
25 A
LUS or LUB 12 and 32 & GV2
AK5PA231
98.00
2.13
54
25 A
GV2 & Contactor
AK5PA232
120.00
4.25
108
25 A
GV2 & Reversing Contactor
AK5PA232S
206.00
Table 18.151: Bus Tap-off
Plugs into busbar for wiring to a separately mounted device.
Width
AK5PA232S
AK5PC33
IN
Length of
Leads
Thermal
Current Amperes
mm
IN
Catalog Number
$ Price
mm
1.42
36
32 A
9.84
250
AK5 PC33
23.00
1.42
36
32 A
39.37
1000
AK5 PC33L
37.80
Table 18.152: Extension Plates
Used to mount wider components. Bolt to standard mounting plates
(after DIN rails are removed).
Width
IN
mm
2.80
71
Application
Catalog Number
GV & Reversing contactor
AK5PE27
$ Price
26.30
Table 18.153: Mounting Rail
Must be used for mounting plates with tap-offs.
Depth
Length
mm
mm
Catalog
Number
15
2000
AM1DL201
Description
75 mm Omega Rail
$ Price
41.10
AM1DL201
Table 18.154: Approvals: IEC 439, UL, CSA, DNV, LROS
File E161251
CCN NMTR
© 2009 Schneider Electric
All Rights Reserved
File LR 89150
Class 6228-01
I11
Discount
Schedule
18-39
18
Width
IN
IEC CONTACTORS AND
STARTERS
Table 18.150: Mounting Plate Tap-off
Plugs into busbar mounted on AM1DL201 DIN rail.
TeSys® D Contactors, AC Coil
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
Table 18.155: TeSys D Contactors AC Control Circuits
LC1D09 to D18 (3-pole) and LC1DT12 to LC1DT40 (4 pole)
LC1D25 to D38 (3-pole)
Minimum electrical clearance
Minimum electrical clearance
Minimum electrical clearance
1.73
44
Minimum electrical clearance
b
b
b1
b
b
LA4
c
.39
10
c
.39
10
c1
c2
c2
c3
c3
AC Coil
.51
13
(LAD8)
D09 to D18
c
c2
c3
a
b
AC coil, without add-on accessories
DC coil
AC coil, with LAD4BB b
3.70 (94)
AC coil, with LA4D*2 b
4.33 (110) a
AC coil, with LA4DF, DT b
4.68 (119) a
AC coil, with LA4DR, DW, DL b
4.96 (126) a
AC coil, without cover or add-on blocks
3.30 (84)
AC coil, with cover, without add-on blocks
3.38 (86)
DC coil, without cover or add-on blocks
3.66 (93)
DC coil, with cover, without add-on blocks
3.76 (95)
AC coil, with LADN or C (two or four contacts) 4.60 (117)
DC coil, with LADN or C (two or four contacts) 4.96 (126)
AC coil, with LAD6K10
5.07 (129)
DC coil, with LAD6K10
5.43 (138)
AC coil, with LADT,R,S
5.39 (137)
AC coil, with LADT,R,S and sealing cover
5.55 (141)
DC coil with LADT,R,S
5.76 (146)
DC coil with LADT,R,S and sealing cover
5.90 (150)
Including LAD4BB
Not applicable to devices with DC coils
c1
c2
c2
c3
c3
1.77
45
D093 to D18 D099 to D189
IN (mm)
3.89 (99)
IN (mm)
3.14 (80)
D25 to D38 D183 and D323 DT20 and DT25 DT203 and DT253 DT32 to DT40 DT323 and DT403
IN (mm)
3.36 (85)
4.21 (107)
3.75 (95.5)
3.85 (98)
4.84 (123) a 4.30 (111.5) a 4.48 (114) a
5.19 (132) a 4.76 (120.5) a 4.84 (123) a
5.67 (139) a 5.0 (127.5) a 5.11 (130) a
3.30 (84)
3.30 (84)
3.54 (90)
3.38 (86)
3.38 (86)
3.62 (92)
3.66 (93)
3.66 (93)
3.89 (99)
3.76 (95)
3.76 (95)
3.97 (101)
4.60 (117)
4.60 (117)
4.84 (123)
4.96 (126)
4.96 (126)
5.19 (132)
5.07 (129)
5.07 (129)
5.31 (135)
5.43 (138)
5.43 (138)
5.66 (144)
5.39 (137)
5.39 (137)
5.62 (143)
5.55 (141)
5.55 (141)
5.78 (147)
5.76 (146)
5.76 (146)
5.98 (152)
5.76 (146)
5.76 (146)
6.14 (156)
IN (mm)
3.89 (99)
IN (mm)
3.34 (85)
IN (mm)
3.89 (99)
IN (mm)
3.58 (91)
IN (mm)
4.13 (105)
4.21 (107)
4.84 (123) a
5.19 (132) a
5.47 (139) a
3.54 (90)
3.62 (92)
3.89 (99)
3.97 (101)
4.84 (123)
5.19 (132)
5.31 (135)
5.66 (144)
5.62 (143)
5.78 (147)
5.98 (152)
6.14 (156)
3.85 (98)
4.48 (114)
5.02 (129)
7.48 (190)
3.54 (90)
3.62 (92)
—
3.90 (99)
4.84 (123)
4.84 (123)
5.31 (135)
5.31 (135)
5.62 (143)
5.78 (147)
5.62 (143)
5.78 (147)
—
—
—
—
3.54 (90)
3.62 (92)
—
3.90 (99)
4.84 (123)
4.84 (123)
5.31 (135)
5.31 (135)
5.62 (143)
5.78 (147)
5.62 (143)
5.78 (147)
—
—
—
—
3.85 (98)
3.93 (100)
—
4.21 (107)
5.15 (131)
5.15 (131)
5.62 (143)
5.62 (143)
5.94 (151)
6.10 (155)
5.94 (151)
6.10 (155)
—
—
—
—
3.85 (98)
3.93 (100)
—
4.21 (107)
5.15 (131)
5.15 (131)
5.62 (143)
5.62 (143)
5.94 (151)
6.10 (155)
5.94 (151)
6.10 (155)
Table 18.156: AC Coil
LC1D80004 (4P)
5.75* (LA1)
146
2.95 (3P) 3.34 (4P)
85
75
.51
13
(LA8)
6.50** (LA2, LA3, LA6 DK1)
165
.51
13
(LA8)
xcept LA1DN10, DN01 = 136
+4 mm with lead sealing device
a
with LA4 D•2
with LA4 DB3 or LAD 4BB3
with LA4 DF, DT
with LA4 DM, DW, DL
without cover or add-on blocks
c
with cover, without add-on blocks
with LAD N (1 contact)
c1
with LAD N or C (2 or 4 contacts)
c2 with LAD 6K10 or LA6 DK
with LAD T, R, S
c3
with LAD T, R, S and sealing cover
b1
b1
c
c2
6.77** (LA2, LA3, LA6 DK2)
172
LC1
Minimum electrical clearance
c1
6.02* (LA1)
153
.51
13
(LA8)
3.34 (3P) 3.78 (4P)
96
85
.51
13
(LA8)
*except LA1DN10, DN01 = 136
** +4 mm with lead sealing device
LC1 D40A…D65A (3P), LC1 DT60A…DT80A (4P) AC OR DC
0.47
12
4.92
125
5.00
127
5.00
127
5.20 (LA4 DA2, DE2)
132
5.59 (LA4 DF, DT)
142
5.91 (LA4 DM, DR, DW, DZ)
150
4.49
114
5.51 (LA4 DA2, DE2)
140
5.79 (LA4 DF, DT)
147
6.18 (LA4 DM, DR, DW, DZ)
157
LC1D40, D50, D65 (3P), LC1D65004 (4P)
4.80
122
IEC CONTACTORS AND
STARTERS
c1
IN (mm)
3.03 (77)
4.61
117
18
b1
c
.39
10
c1
1.77
45
DC Coil
LC1
b
c
.39
10
c1
0.49
12.5
(LAD 8N)
a
0.49
12.5
(LAD 8N)
D40A…D65A
DT60A…DT80A
D40008
IN (mm)
2.17 (55)
—
5.35 (136)
6.18 (157)
6.54 (166)
4.65 (118)
4.72 (120)
—
5.91 (150)
6.42 (163)
6.73 (171)
6.89 (175)
IN (mm)
2.76 (70)
—
—
—
—
4.65 (118)
4.72 (120)
—
5.91 (150)
6.42 (163)
6.73 (171)
6.89 (175)
IN (mm)
3.35 (85)
5.31 (135)
—
5.59 (142)
5.91 (150)
4.92 (125)
—
5.47 (139)
5.79 (147)
6.26 (159)
6.57 (167)
6.73 (171)
c3
18-40
© 2009 Schneider Electric
All Rights Reserved
TeSys® D Contactors, DC Coil
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
Table 18.157: DC Coil
LC1D40, D50, D65 (3P), LC1D650004, (4P)
LC1D80 (3P), LC1D800004(4P)
Minimum electrical clearance
2.95(3P) 3.34(4P)
75
85
8.03* (LA1)
204
8.78d (LA6 DK2, LA2, LA3)
223
7.13
181
4.96
126
4.96
126
5.20 (LA4 DC3)
132
5.47 (LA4 DF, DT)
139
5.75 (LA4 DM, DR, DW, DZ)
146
6.73
171
.47
12
5.51 (LA4 DC3)
140
5.79 (LA4 DF, DT)
147
6.06 (LA4 DM, DR, DW, DZ)
154
Minimum electrical clearance
.47
12
8.27* (LA1)
210
9.02d (LA6 DK3, LA2, LA3)
223
3.34 (3P) 3.78(4P)
85
96
*except LA1DN10, DN01 = 143
d + 4 mm with lead sealing device
*except LA1DN10, DN01 = 136
d + 4 mm with lead sealing device
c
=
G
=
LC1
D115
D1156
D150
D1506
c
5.12 (132)
4.53 (115)
5.12 (132)
4.53 (115)
G (3-poles)
3.78/4.33 (96/110)
3.78/4.33 (96/110)
3.78/4.33 (96/110)
3.78/4.33 (96/110)
G (4-poles)
5.12/5.67 (130/144)
5.12/5.67 (130/144)
—
—
6.22
158
LA4
LA8
c
LC1
D115, D150
D115004
D1156, D1506
D1150046
C
5.12 (132)
5.12 (132)
4.53 (115)
4.53 (115)
18
6.61c (LA2, LA3)
168
6.85 (LA4D•2, D•3)
174
7.28 (DF, DT)
185
7.40 (DM, DR, DW, DL)
188
LC1D115, D150
A
4.72 (120)
6.10 (155)
4.72 (120)
6.10 (155)
a
5.91q (LA1)
150 6.10 (LA6-DK20)
155
a
b
With 2 or 4 contacts.
+ 4 mm with sealing cover.
LR9D solid-state overload relay
Direct mounting beneath contactors
LC1D115 and D150
5.20
132
d
35 mm DIN rail dimensions
AM1DP200 and DR200
d
0.10 (2.5)
10.04
255
4.72
120
AM1DE••• and ED•••
.41 (10.5)
5.20
132
d
35 mm DIN rail dimensions
AM1DP200 and DR200
d
0.10 (2.5)
5.35
136
6.85
174
5.91
150
7.44
189
10.51
267
LR2D4 bimetallic overload relay
Direct mounting beneath contactors
LC1D115 and D150
4.72
120
AM1DE••• and ED•••
.41 (10.5)
Note: All dimensions are in Inches (mm).
© 2009 Schneider Electric
All Rights Reserved
IEC CONTACTORS AND
STARTERS
=
5.12
130
6.22
158
=
LC1D115, D150
Panel mounted with 1/4” screws
18-41
TeSys® F Contactors
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
All dimensions shown in mm.
To convert to inches divide by 25.4.
LC1F115 to F330
S
s1
Table 18.158:
a
M
b2
a
b
b1
b2
c
f
G
G1
J
J1
=
b
=
F115
LC1
c
Q
L
P
Q1
P
18
a
f
c
X1 (see table 18.158)
Protective cover Type
LA9F70•.
J
J1
IEC CONTACTORS AND
STARTERS
b1
=
a
=
=
G1
=
G
Y
LC1F400 to F500
S
2.20
56
=
M
b2
b
=
8.23
209
e
Q
P
c
Q1
P
a
f
=
=
4.7
120
7.09
180
8 X 8.5 dia.
=
G1
Dual Dimensions:
18-42
145
181
48
43
74
25
44.5
38
20.5
145
181
48
43
74
25
44.5
38
20.5
220/380
415/440
500
660
1000
LC1F115, F150
20
25
30
40
20
LC1F185
20
25
30
40
30
LC1F265
20
25
40
50
40
LC1F330
25
35
40
50
50
Note: X1: Minimum clearance according to the operational voltage and the
breaking capacity.
J
a
b
b2
c
f
F400
2-Pole
213
206
375
213
119
3-Pole
213
206
375
213
119
F500
4-Pole
261
206
375
213
119
2-Pole
233
238
400
226
141
Gd
80
80
80
80
G min.
66
66
66
66
G max.
102
102
150
120
G1d
170
170
170
170
G1 min.
156
156
156
156
G1 max.
192
192
240
210
d
Supplied
J
19.5
19.5
67.5
39.5
L
145
145
145
146
M
181
181
181
208
P
48
48
48
55
Q
69
43
43
76
Q1
96
74
74
102
S
25
25
25
30
e
Protective cover.
Note: f = Minimum distance required for coil removal.
3-Pole
233
238
400
226
141
4-Pole
288
238
400
226
141
80
66
120
170
156
210
140
66
175
230
156
265
39.5
146
208
55
46
77
30
34.5
146
208
55
46
77
30
Table 18.161:
=
G
.92
23.5
F330
Table 18.160:
1.49
38
M10 X 30 dia.
L
F265
Table 18.159:
LC1
(see table 18.160) X1
F185
343434Pole Pole Pole Pole Pole Pole
168.5 208.5 201.5 243.5 213 261
174 174 203 203 206 206
137 137 145 145 145 145
305 305 370 370 375 375
176 176 207 207 219 219
130 130 147 147 147 147
111 151 142 190 154.5 202.5
80
80
96
96
96
96
106 106 106 106 106 106
120 120 120 120 120 120
L
107
107 107
107 113.5 113.5 141 141
M
147
147 150
150
154 154 178 178
P
37
37
40
40
40
40
48
48
Q
29.5 29.5 26.5
26
29
29
39
34
Q1
60
60
57.5 55.5 59.5 59.5 66.5 66.5
S
15
15
20
20
20
20
25
25
S1
27
27
34
34
34
34
38
38
Y
44
44
44
44
44
44
38
38
Z
13.5 13.5 13.5 13.5 13.5 13.5 21.5 21.5
b
+6 mm with time delay block (for F115 and F150).
c
Optimal terminal shroud
Note: f = minimum distance required for coil removal.
Voltage in V
Z
F150
433-Pole Pole
Pole 4-Pole
163.5 200.5 163.5 200.5
162
162 170
170
137
137 137
137
265
265 301
301
165b 165b 165b 165b
131
131 131
131
106
143 106
143
80
80
80
80
106
106 106
106
120
120 120
120
Voltage in V
220/230
415/440
500
660
1000
LC1F400
30
40
40
50
60
LC1F500
40
45
50
60
60
Note: X1: Minimum clearance according to the operational voltage and the
breaking capacity.
INCHES
Millimeters
© 2009 Schneider Electric
All Rights Reserved
TeSys® F Contactors
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
LC1F630 and LC1F800
2.52
64
1.57
40
2.83
72
Dual Dimensions:
6 x M12 x 45
INCHES
Millimeters
c
=
=
7.09
180
10.39
264
18.28
464
11.02
280
11.97
304
=
=
4 x Dia. 10.5 mm
9.84
250
7.76
197
Q
6.10
155
3.15
80
3.15
80
G supplied
G min.
J1
7.13*
181
a
a
G
2.38
60
Q1
G max.
J1
Q
Q1
IEC CONTACTORS AND
STARTERS
X1
LC1F630
* = minimum distance
required for coil
removal.
c Protective terminal
cover.
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
2P
12.17
309
7.09
180
3.94
100
7.68
195
2.70
68.5
4.02
102
5.00
127
3P
12.17
309
7.09
180
3.94
100
7.68
195
2.70
68.5
2.36
60
3.50
89
4P
15.31
389
9.45
240
5.91
150 10.83
275
2.70
68.5
2.36
60
3.50
X1:Minimum clearance according to the
operational voltage and the breaking capacity.
Voltage in V
380
415/440
X1 in mm
60
60
89
500 660 1000
60
70
80
LC1F780, F7804
1.02
26
12 x M14 x 45
2.36
60
18
=
15.74
400
17.08
434
13.70
348
11.02
280
.86
22
=
1.02
26
6.50
165
9.84
250
X1
6.30
160
7.52
191
27.64f
702
7.20*
183
380
415/440
660
1000
X1 in mm
90
100
120
120
LC1F780 mounting
7.52
191
7.20*
183
f Overall length (3 poles)
X1: Minimum clearance according to the operational voltage and the breaking
capacity.
Voltage in V
6.30
160
33.93a
862
a Overall length (4 poles)
*minimum distance required for coil removal.
5.00
127
5.00
127
LC1F7804 mounting
6 x Dia. 10.5 mm
3.50
90
9.45
240
© 2009 Schneider Electric
All Rights Reserved
9.45
240
5.20
132
5.00
127
5.00
127
7.09
180
7.09
180
8 x Dia. 10.5 mm
3.50
90
9.45
240
7.48
190
9.45
240
4.00
102
18-43
TeSys® D Reversing Contactors
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
2 x LP1D40, D65, D80, D95
LC2D09 to D32
LC2DT20 to DT60
2 x LC1DT20 to DT60
G1
=
4.33
110
=
2.36
60
b
3.94
100
b
2.76
70
=
c
a
IN (mm)
DT20 and DT25
3.54 (90)
DT32 to DT60
3.54 (90)
c, e2: includes cabling.
b
c
G
IN (mm)
3.34 (85)
3.58 (91)
IN (mm)
3.54 (90)
3.85 (98)
IN (mm)
3.14 (80)
3.14 (80)
a
LC2 or 2 x LC1
b
c
1.57
40
G
e1
e2
a
1.57
40
G
=
G1
IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm)
D40 to D65
7.16 (182) 5.0 (127) 7.4 (190) 1.19 (5) 0.43 (11) 2.2 (57) 3.8 (97)
D80 and D95 8.14 (207) 5.0 (127) 8.4 (215) 0.51 (13) 0.78 (20) 3.7 (96) 4.3 (111)
c, e1 and e2: includes cabling.
=
e1
Dimensions shown in millimeters
(mm ÷ 25.4 = inches)
=
5.12
130
6.22
158
IEC CONTACTORS AND
STARTERS
LC2D115 and D150
2 x LC1D115 and D150
Panel mounted with 1/4” screw
e2
18
a
LC2 or 2 x LC1
=
e2
=
G
=
e2
c
.51
13
2xM0.16
2xM4
=
.31
8
e1
6xØ0.26
6xØ6.5
=
G
c
=
a
LC2 or 2 x LC1 (3-pole)
D115, D150
LC2 or 2 x LC1 (4-pole)
a
266
a
c
148
c
e1
56
e1
e2
18
e2
G
242/256
G
D115
c, e1 and e2 includes cabling
334
148
—
60
310/324
NOTE: For dimensions of TeSys F reversing contactors, please refer to Catalog 8502CT9901.
18-44
© 2009 Schneider Electric
All Rights Reserved
TeSys® D Overload Relays
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
Independent mounting on 110 mm centers
LRD-01-35
Independent mounting on 50 mm centers or on rail AM1DP200 or DE200
1.38
35
.39
10
1.81
46
=
=
=
LAD7B106
4.33
110
=
1.77
45
.20
5
.08
2
.24
6
3.15
80
4.92
125
1.50
38
1.97
50
3.15
80
.59
15
LAD7B106
Remote tripping or electrical reset
DX1AP25
3.54
90
LAD703 a
2xØ0.26
2xØ6.5
LRD, LR2D and LR9D
“Reset” by flexible cable LA7D305 and LAD7305
Mounting with cable straight
Mounting with cable bent
e
a
Can only be mounted on RH side of relay LRD-01 to 35
c
e
IEC CONTACTORS AND
STARTERS
1.26
32
M10x0.04
M10x1
c: up to 21.6in (550 mm)
e: up to 0.79in (20 mm)
LRD3tt
Beneath LC1DttA contactor
Separate mounting
3.43
87
7.28
185
18
LC1D pp A
2.17
55
4.57
116
2.17
55
LR2D1, LR3D1
Separate mounting at 50 mm (1.97”) centers or on AM1DP200 or DE200 rail
d
2xØ0.18
2xØ4.5
3.54
90
0.31
8
0.67
17
3.86
98
LR2D1, LR3D1
Separate mounting at 110 mm (4.33”) centers
d
2xØ0.18
2xØ4.5
=
0.51
0.87 13
22
LR2D2, LR3D2
Separate mounting at 110 mm (4.33”) centers
2.24
57
=
=
=
1.81
46
=
DX1AP25
2.17
55
1.57
40
=
1.97/2.56
50/65
LA7-D2064
LA7D2064
DX1AP25
LA7D1064
=
=
3.86
98
=
1.71
43.5
1.48
43.5
3.11
79
0.16
4
1.77
45
1.38
35
1.97/2.56
50/65
=
LA7-D1064
LR2D2, LR3D2
Separate mounting at 50 mm (1.97”) centers or on AM1DP200 or DE200 rail
0.12
3
4.84
123
Mounting
Holes
1.97
50
=
=
4.33
110
4.92
125
4.33
110
4.92
125
1.97
50
Mounting
Holes
4.25
108
© 2009 Schneider Electric
All Rights Reserved
2 x Ø6.5 mm
Screws
4.25
108
2 x Ø6.5 mm
Screws
18-45
TeSys® D Thermal Overload Relays
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
LRD-01-35
Direct mounting beneath contactors with screw
18
LC1•
b
c
LRD-013-353
Direct mounting beneath contactors with spring terminal connections
LC1•
b
D09–D18
D25–D38
4.84 (123)
5.39 (137)
See Catalog 8502CT9901
pages 122, 123.
c
D093–383
4.84 (123)
See Catalog 8502CT9901
pages 122, 123.
IEC CONTACTORS AND
STARTERS
LRD-3•••
Direct mounting beneath contactors
LC1-D40 to D95 and LP1-D40 to D80
AM1•
DL201
DL200
d
0.28 (7)
0.67 (17)
b
LC1D40
LC1D50
LC1D65
LC1D80
LC1D95
LC1D40, LP1D40
LC1D50
LC1D65, LP1D65
LC1D80, D95, LP1D80
LRD4•••
Direct mounting beneath contactors
LC1D115 and D150
a
AM1DL200 and DR200
AM1DE200 and ED•••
d
0.10 (2.5)
0.41 (10.5)
For Additional characteristics and Catalog Number information, see Catalog 8502CT9901
18-46
c
e
AC Control Circuit
4.37 (111)
4.69 (119) 2.85 (72.4)
4.37 (111)
4.69 (119) 2.85 (72.4)
4.37 (111)
4.69 (119) 2.85 (72.4)
4.55 (115.5) 4.88 (124) 3.03 (76.9)
4.55 (115.5) 4.88 (124) 3.03 (76.9)
DC Control Circuit
4.37 (111)
6.93 (176) 2.85 (72.4)
4.37 (111)
6.93 (176) 2.85 (72.4)
4.37 (111)
6.93 (176) 2.85 (72.4)
4.55 (115.5) 7.06 (179.4)
3.03 (76.9)
g(3P)
g(4P)
0.18 (4.5)
0.18 (4.5)
0.18 (4.5)
0.37 (9.5)
0.37 (9.5)
0.51 (13)
—
0.51 (13)
0.87 (22)
—
0.18 (4.5)
0.18 (4.5)
0.18 (4.5)
0.51(13)
—
0.51(13)
0.37 (9.5)
0.87(22)
LR9D
Direct mounting beneath contactors
LC1D115 and D150
d
AM1DP200 and DR200
0.10 (2.5)
AM1DE200 and ED•••
0.41 (10.5)
© 2009 Schneider Electric
All Rights Reserved
TeSys® F Overload Relays
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
bc
2.80
71
2.80
71
4.53
115
4xØ5.5
.79
20
P1
P2
Ø11
1.18
30
4xØ5.5
3.15
80
Ø13
3.15
80
2.44
62
1.57
40
3.23
82
5.39
137
.24
6
.87
22
2.76
70
5.94
151
7.44
189
.98
25
2.05
52
2.60
66
9.02
229
1.77
45
4.29
109
2.05
52
2.60
66
1.57
40
P1
48
55
LR9F7•75
LR9F7•79, F7•81
Terminal shroud LA9-F70•
7.87
200
.79
20
.55
14
1.65
42
IEC CONTACTORS AND
STARTERS
LR9F7•81
(for mounting beneath LC1F630)
.24
6
c
2.36
60
3.78
96
1.97
50
2.36
60
2.99
76
LR9F7•75, F7•79, F7•81
Common side view
5.04
128
4.72
120
4xØ5.5
4.53
115
1.85
.11
47
3
Terminal shroud LA9F70•
6.5 x 13.5 for LR9F5•57 and 8.5 x 13.5 for LR9F5•63, F5•67, F5•69
cf
1.97
50
1.97
50
1.57
40
2.99
76
1.89
48
3.98
101
.98
25
1.97
50
1.57
40
18
a
b
1.89
48
Ø11
.22
6
2.24
57
1.77
45
aq
4.88
124
.11
3
LR9F5•57, F5•63, F5•67, F5•69
.22
6
LR9F5•71
Common side view
P2
48
55
3.03
77
3.03
77
Direct mounting beneath reversing contactors or star-delta contactors
b
H1
b
H3
H3
Direct mounting beneath contactor LC1-F
7.60
193
H2
H2
H4
LA7F40
e
LA7F40p
Bar
Busbar
Bus
d
d
LC1 contactors
F115
F150
F185
F225
d
e
With LR9 relays
F5•57, F5•63, F5•67, F5•69
F5•57, F5•63, F5•67, F5•69
F5•57, F5•63, F5•67, F5•69
F5•71
F7•75, F7•79
F265
F5•71
F7•75, F7•79
F330
F7•75, F7•79
F400
F7•75, F7•79, F7•81
F500
F7•75, F7•79, F7•81
F630
F7•81
Relay mounting plate, see page 18-16.
Connection Accessories, see page 18-16.
© 2009 Schneider Electric
All Rights Reserved
b
240
246
250
273
308
279
314
317
317
346
510
H1
30
30
30
40
50
40
60
60
60
70
110
H2
76
76
76
76
108.8
76
108.8
108.8
108.8
108.8
108.8
H3
120
120
120
120
120
120
120
120
180
180
180
LC1 contactors
F115
F150
F185
F225
F265
F330
F400
F500
F630
With LR9 relays
F5•57, F5 • 63, F5•67, F5•69
F5•57, F5•63, F5•67, F5•69
F5•57, F5•63, F5•67, F5•69
F5•71
F7•75, F7•79
F5•71
F7•75, F7•79
F7•75, F7•79
F7•75, F7•79, F7•81
F7•75, F7•79, F7•81
F7•81
b
279
283
285
319
360
332
363
364
364
390
509
H4
60
60
60
80
100
90
100
100
100
110
120
H2
76
76
76
76
108.8
76
108.8
108.8
108.8
108.8
108.8
H3
120
120
120
120
120
120
120
120
180
180
180
18-47
TeSys® D Combination and Non-combination Starters
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
NEMA 1
D09-25 (FVNR)
D09-40 (FVR); D32-40 (FVNR)
10.00
254
5.00
7.50
127
191
3.00
7.50
76
191
18.00
203
419
16.50
R
318
12.52
18
14.02
18
356
.69
457
8.00
R
IEC CONTACTORS AND
STARTERS
Provision for 1/4" Screw
Provision for 1/4" Screw
NEMA 12/3R
D09-25 (FVNR)
D09-40 (FVR); D32-40 (FVNR)
10.00
254
5.00
7.75
127
197
8.00
3.00
7.75
457
18.00
499
19.63
356
14.00
378
18.88
197
397
15.63
14.88
76
480
203
R
R
Provision for 1/4" Screw
Provision for 1/4" Screw
A
13
.50
Non-combination Starter Dimensions
.75
E
B
19
J
K
C
R
F
14
.56
D/2
D
G
H
Provision for 1/4" Screw
Table 18.162: Non-combination Starter Dimensions
TYPE 1
Non-reversing
Reversing
A
D09-32
—
6.77
D40-65
D09-32
8.66
D80
D40-80
10.63
Note: All dimensions in inches.
18-48
B
10.04
10.83
13.98
C
6.25
7.21
7.21
D
5.38
7.25
9.22
E
9.00
9.75
12.94
F
1–1.25
1.25–1.5
1.25–1.5
TYPE 12/3R
G
0.5–0.75
0.5–0.75
0.5–0.75
H
—
1–1.25
1–1.25
J
1–0.25
1–0.25
1–1.25
K
0.5–0.75
0.5–0.75
0.5–0.75
D
5.38
5.38
5.38
E
11.37
12.15
15.30
© 2009 Schneider Electric
All Rights Reserved
TeSys® K Contactors
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
LR2K
Direct mounting under the contactor
Separate mounting with LA7-K0064 terminal block on 35 mm
(AM1DP200 or AM1DE200)
1.38
35
4.57
116
2.28
58
2.56
65
3.15
80
1.50
38
4 x Ø4
1.97
50
.31
8
rail
1.77
45
1.77
45
13
A1
13
5
3
Wiring Scheme
1
Three-phase
2.95
75
3.09 (DP200)
78
3.38 (DE200)
86
95
95
Internal
Links
96
98
A2
96
Test
LC1, LP1, LP4K
mini-contactors
On baseplate
96
6
98
LC2, LC8, LP2, LP5K
reversing mini-contactors
On baseplate
LA1-K
8 x Ø4
2.28
58
1.97
50
2.28
58
4 x Ø4
1.38
35
1.77
45
2.24
57
1.97
50
LA1-K
2.24
57
1.22
31
3.15
80
3.54
90
On AM1DP200 or DE200 rail ( 35 mm)
2.28
58
2.28
58
On AM1DP200 or DE200 rail ( 35 mm)
2.24
57
On printed circuit board
2.24
57
1.77
45
3.54
90
On printed circuit board for reversing contactors or 2 mini-contactors side-by-side
A1
10 x Ø.051
10 x Ø1.3
.34
9
1.77
45
.34
A1 9
A1
2.28
58
1.97
50
2.05
52
2.28
58
.34
9
A2
20 x Ø.051
20 x Ø1.3
A2
1.97
50
2.05
52
1.22
31
95
4
2
97
A1
– KM1
Reset/Stop
1.77
45
1.77
45
A2
Table 18.163:
LA2KT
Electronic time delay contact blocks
On mini-contactors or reversing mini-contactors
1.34
34
Dual Dimensions:
© 2009 Schneider Electric
All Rights Reserved
2.28
58
1.06
27
LA2-KT
1.50
38
INCHES
Millimeters
1.34
34
2.24
57
18-49
18
96
6
4
2
O
IEC CONTACTORS AND
STARTERS
14
A2
6
4
2
95
97
14
– KM1
5
3
1
A
H
TeSys® U Motor Starters
Dimensions
Refer to Catalog 8502CT0201
www.schneider-electric.us
Starter Controllers
Reversing
Rail Mounting
126
4.96
1.18
Ø4
.15
1.14
163
6.42
224
8.82
73
2.87
154
6.06
X1
45 X2
1.77
Screw Mounting
29
30
X2
135a
5.31
Rail Mounting
135a
5.31
120/125
4.72/4.92
X1
126
4.96
Screw Mounting
Ø4
.15
233
9.17
Non-reversing
45
1.77
18
Note: Minimum electrical clearance:
X1 = 35 mm for Ue = 440 V and 70 mm for Ue = 500 and 690 V,
X2 = 0
a
Maximum depth (with MODBUS® communication module)
Reversing block for mounting separately from power base
Rail Mounting
Screw Mounting
104
4.09
115
4.53
113
4.45
113
4.45
45
1.77
36
1.41
93
3.66
Limiter disconnector LUALB1
154
6.06
135a
5.31
a
45
1.77
Maximum depth (with MODBUS communication module)
Door interlock mechanisms
LU9AP00
Door cut-out
= =
54
2.12
55
2.16
Ø43
1.69
230
9.06
IEC CONTACTORS AND
STARTERS
Ø4
.15
= =
54
2.12
4xØ3.5
.13
Dual Dimensions:
508
20.01
18-50
11.5
.45
8
.31
INCHES
Millimeters
Ø7
.27
© 2009 Schneider Electric
All Rights Reserved
Altistart® U01 and TeSys® U Soft Starters
Dimensions
Refer to Catalog 8502CT9901
www.schneider-electric.us
TeSys U combination
(non-reversing power base) and ATSU 01N212LT
Mounting on § (35mm) rail with VW3 G4104 connector
TeSys U combination
(non-reversing or reversing power base) and
ATSU 01N2206LT to ATSU 01N212LT
Side-by-side mounting
45
1.77
135
5.31
284
11.18
150
5.91
124
4.88
154
6.06
72.2
2.84
99
3.9
9
0.354
IEC CONTACTORS AND
STARTERS
9
0.354
TeSys U combination
(non-reversing or reversing power base) and ATSU 01N222LT
to ATSU 01N232LT
Side-by-side mounting
TeSys U combination
(non-reversing power base) and
ATSU 01N222LT to ATSU 01N232LT
Mounting on § (35mm) rail with VW3 G4104 connector
135
5.31
18
154
6.06
72.2
2.84
45
1.77
99
3.9
314
12.36
170
6.69
9
0.354
VW3 G4104 Power connector
46.6
1.83
9
0.354
44.8
1.76
6
0.24
28
1.10
20
0.79
© 2009 Schneider Electric
All Rights Reserved
18-51
TeSys® Manual Starters and Protectors
Dimensions
Refer to Catalog 2520CT0001
www.schneider-electric.us
GV2AD, AM, AN, AU, AS, AX
GV2AE
Block GV2AD, AM, AN
Block GV2AU, AS, AX
Mounting of GV2M
On 35 mm
rail
C = 78.5 mm (3.09") on AM1DP200 (35 x 7.5 mm)
C = 86 mm (3.39") on AM1DE200, ED200 (35 x 15 mm)
16
44
.63 1.73
66
2.60
44.5
1.75
44.5
1.75
9.3
.37
GV2P
9.3
.37
81
3.19
18
.71
c
GV2AD, AM, AN, AU, AS, AX
14
.55
On 35 mm
rail
C = 98.5 mm (3.88") on AM1DP200
(35 x 7.5 mm)
C = 106 mm (4.17") on AM1DE200, ED200
(35 x 15 mm)
98
3.86
32
1.26
=
Block GV2AD, AM, AN
Block GV2AU, AS, AX
Mounting of GV2P
44.5
1.75
9.3
.37
9.3
.37
81
3.19
18
.71
44.5
1.75
GV2AF4 + LAD31
Combination GV2P + TeSys D range
contactor
GV2P + GV2GH7
GV2P + GV2GH7 + TeSys D contactor
for UL 508 Type E application
b
45
1.77
c
c1
3.6 (91.4)
3.6 (91.4)
3.8 (96.52)
3.8 (96.52)
44
1.73
45
1.77
c
13.5
.53
for UL 508 Type E application
b
IEC CONTACTORS AND
STARTERS
c1
d1
c
103
4.07
Combination GV2ME + TeSys D range contactor
d
GV2ME +
b
c1
c
d1
d
LC2D09 to D18
7.4 (188.6)
3.6 (92.7)
3.9 (98.2)
3.9 (98.3)
4.1 (103.8)
LC2D25 and D32
7.8 (199)
3.9 (99)
4.11 (104.5)
3.9 (98.3)
1.4 (103.8)
GV2P +
b
c1
c
—
—
•
LC2D25 and D32
7.9 (199.5)
4.6 (116.8)
4.8 (122.3)
—
—
• (bracket cut-out)
Flush mounting enclosure GV2MP0
=
Surface mounting enclosure GV2MC0
a
LC2D09 to D18
6.61 (168.1)
4.6 (116.8)
4.8 (122.3)
—
—
84
3.31
93
3.66
a
=
13
0.51
=
1...6 /0.04...0.24
84
3.31
=
93.5
3.68
106.5
4.19
=
71
2.8
6.5
0.25
92.8
3.65
4 knock-outs for 16 mm
plastic cable glands or no.
16 conduit.
GV2
MP01, MP02
MP03, MP04
18-52
b
130
5.12
=
147
5.79
b1
=
2xØ5.3x6.3
=
18
15
.59
50
1.97
82
3.23
191
7.50
26
1.02
44.5
1.75
=
44.5
1.75
45
1.77
61
2.40
89
3.50
GV2AK00
84
3.31
11
.43
44.5
1.75
=
89
3.5
45
1.77
=
15
.59
10
.39
GV2M
b
IN
5.51
5.24
b1
mm
140
133
IN
5.00
4.61
mm
127
117
© 2009 Schneider Electric
All Rights Reserved
TeSys® Manual Starters and Protectors
Dimensions
Refer to Catalog 2520CT0001
www.schneider-electric.us
GV2M with GK2AF01 and LC1K
GV2M with GV2AF01 and LC1K
GV2M with GV2AF01 and LC2K
Adapter plate GK2AF01
5
.2
35
1.38
dimensions in mm
4xØ3.5 Ø43
0.14
1.7
50/60
1.97/2.36
=
54
2.13
=
=
54
2.13
5.2
0.21
= =
80
3.15
Sets of bus bars, GV2G445, GV2G454, GV2G472
with terminal block GV2G05
Sets of bus bars with terminal block GV1G09
35
1.38
13
0.51
35
1.38
Sets of bus bars GV2G245, GV2G254,
GV2G272
p
l
1.2
30
l
18
2.5
63
.71
18
.12
3
7.5 mm height compensation plate
GV1F03
4.2
.17
=
1.5...5/0.06...0.20
min.=150
max.=290
5.91
11.42
35
1.38
GV2M on panel with GV2AF02 adapter
plate
Door cut-out
7
.276
53
2.1
54
2.13
9.5
.37
39
1.54
Mounting external operator GV2AP0•
65
2.56
24
.94
90
3.54
IEC CONTACTORS AND
STARTERS
45
1.77
79
3.11
105 ± 5
4.13 ± .2
135
5.31
45
1.77
45
1.77
152
6.0
152
6.0
55
2.17
Ø5.5
.22
1.8
45
GV2G445
GV2G454
GV2G472
I
7.0" (179 mm)
8.1" (206 mm)
10.2" (260 mm)
0.16 x 1.8" (4 x 45 mm)
0.16 x 2.1" (4 x 54 mm)
0.16 x 1.8" (4 x 45 mm)
P
1.8" (45 mm)
2.1" (54 mm)
2.8" (72 mm)
GV2G245
GV2G254
GV2G272
GV2G354
I
3.5" (89 mm)
3.9" (98 mm)
4.6" (116 mm)
6.0" (152 mm)
0.08 x 1.8" (2 x 45 mm)
0.08 x 2.1" (2 x 54 mm)
0.08 x 2.8"(2 x 72 mm)
0.12 x 2.1" (3 x 54 mm)
GV3 P
Dimensions
Mounting on rail AM1 DE200 or AM1 ED201
X1
(1)
64
64
132
68
68
(2)
144
55
X1
136
9
18
Blocks GV ANpp , GV ADpp , GV AM11
Block GV3 AUpp and GV3 ASpp
Mounting on pre-slotted mounting plate AM1 PA
X1 = Electrical clearance (ISC max)
40 mm for Ue < 500 V, 50 mm for Ue < 690 V
Mounting on panel, using M4 screws
16
183
3xØ4
136
37,5
137,5
137,5
AF1 EA4
136
18,7 18,7
Note: Leave a space of 9 mm between 2 manual motor protectors: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible: please consult your regional
sales office.
© 2009 Schneider Electric
All Rights Reserved
18-53
TeSys® GV7 Manual Starters and Protectors
Dimensions
www.schneider-electric.us
1 GV7R
Panel Mounting
Flush Mounting
side by side
4.25
108
=
=
4.25
108
=
=
4.92
125
1.85
3.0 47
76
=
2xØ0.24
2xØ6
=
1.14
29
==
1.14
29
3.27
83
Minimum clearance
18
Painted or insulated metal plate, insulation or insulated bar
Bare metal plate
U < 440 V
440 V < U < 600 V
U > 600 V
=
=
4.25
108
x1
x2
IN (mm)
0 (0)
0.20 (5)
0.39 (10)
IN (mm)
1.18 (30)
1.38 (35)
1.38 (35)
0.79 (20)
1.38 (35)
x2
3.46
88
x1
x1
x2
1.38 1.38 1.38
35 35 35
IEC CONTACTORS AND
STARTERS
Note: Minimum distance between 2 units mounted side by side = 0.
21
22
24
82
84
81
92
94
91
11
14
12
Add-on auxiliary contacts, GV7AE11, GV7AB11
5/L3
3/L2
1/L1
Motor controllers GV7R
6/T3
4/T2
2/T1
Note: A self-adhesive label, supplied with the contact, can be affixed to the front face of the starter
to allow personalized marking according to the function of the contact or contacts.
GV7AS•••
GV7AD111, AD112
50 ms
98
97
50 ms
13
97
D4
C2
97
D1
C1
GV7AU•••
50 ms
21
23
98
14
98
– KA1
18-54
A1
– KM1
A2
– KA1
A2
– KA1
B1
A1
22
24
– KA1
© 2009 Schneider Electric
All Rights Reserved
TeSys® GV7 Manual Starters and Protectors
Dimensions
www.schneider-electric.us
GV7AC03
Spreaders
1.61
41
4.49
114
1.77 1.77
45
45
1.18
30
Smooth Terminals
a
Connectors
Z
2.76
70
0.75
19
Z
2.76
70
X
X
X
IEC CONTACTORS AND
STARTERS
Z
0.41
10.5
Cabling
a (in/mm)
0.77/19.5
0.85/21.5
•
•
GV7R
GV7R 220
GV7AP03, GV7A04
60
0
1.10
28
6.10
155
© 2009 Schneider Electric
All Rights Reserved
4.76
121
3.58
91
2.17
55
1.42
36
1.14
29
3.5
89
=
18
DD
73
1.77
2.87 45
I
60
Flush Mounting
1.85
3.0 47
76
Direct Rotary Handle
=
3.82
97
18-55
TeSys® GV7 Manual Starters and Protectors
Dimensions
www.schneider-electric.us
GV7AP03 or GV7AP04, GV7AP05
Direct Rotary Handle
Front Fuse Center
Enclosure viewed from top
0.36
9.25
=
0.35
9
3.94
100
4.72
120
2.32
59
=
h
e
1.61
41
4.92
125
4.72
120
2.72
69
2.0
51
=
=
3.94
100
d
Door cutouts require a minimum distance between the center of the
manual motor protector and the door hinge point (h) of d >/= 3.94 in
(100 mm) + (h x 5)
GV7AP01, GV7AP02
Extended Rotary Handle
0.36
9.25
18
=
=
I
2.95
75
0.35
9
60
0
IEC CONTACTORS AND
STARTERS
60
l
=
=
2.95
75
Note: I: 7.28" (185 mm) minimum, 23.62" (600 mm) maximum. The shaft of the extended rotary handle GV7AP01 or
GV7AP02 must be cut to length: I - 4.96" (126 mm)
18-56
© 2009 Schneider Electric
All Rights Reserved
Similar pages