SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
BQ32002 Real-Time Clock (RTC)
1 Features
3 Description
•
•
The BQ32002 device is a compatible replacement for
industry standard real-time clocks.
1
•
•
•
•
Automatic Switchover to Backup Supply
I2C Interface Supports Serial Clock
up to 400 kHz
Uses 32.768-kHz Crystal With
–63-ppm to +126-ppm Adjustment
Integrated Oscillator-Fail Detection
8-Pin SOIC Package
–40°C to +85°C Ambient Operating Temperature
2 Applications
General Consumer Electronics
The BQ32002 features an automatic backup supply
that can be implemented using a capacitor or nonrechargeable battery. The BQ32002 has a
programmable calibration adjustment from –63 ppm
to +126 ppm. The BQ32002 registers include an OF
(oscillator fail) flag indicating the status of the RTC
oscillator, as well as a STOP bit that allows the host
processor to disable the oscillator. The time registers
are normally updated once per second, and all the
registers are updated at the same time to prevent a
timekeeping glitch. The BQ32002 includes automatic
leap-year compensation.
Device Information(1)
PART NUMBER
BQ32002
PACKAGE
SOIC (8)
BODY SIZE (NOM)
4.90 mm × 3.91 mm
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
Application Circuit
Simplified Schematic
VCC
Place supply-decoupling
capacitor near supply pin
3.0 to 3.6 V
1 µF
BQ32002
VCC
VBACK
Automatic
Backup
Switch
VCORE
Interrupt
Generator
OSCI
OSCO
4.7 kW
32-kHz
Oscillator
I2C Register
Interface With
Undervoltage
Lockout
4.7 kW
4.7 kW
IRQ
SCL
Controller
VCC
SCL
SDA
____
IRQ
Real-Time
Clock
Copyright © 2016, Texas Instruments Incorporated
SDA
Registers
GND
Copyright © 2016, Texas Instruments Incorporated
NOTE: All pullup resistors should be connected to
VCC such that no pullup is applied during
backup supply operation.
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
Table of Contents
1
2
3
4
5
6
7
Features ..................................................................
Applications ...........................................................
Description .............................................................
Revision History.....................................................
Pin Configuration and Functions .........................
Specifications.........................................................
1
1
1
2
3
4
6.1
6.2
6.3
6.4
6.5
6.6
6.7
4
4
4
4
5
6
6
Absolute Maximum Ratings .....................................
ESD Ratings..............................................................
Recommended Operating Conditions.......................
Thermal Information ..................................................
Electrical Characteristics...........................................
Timing Requirements ................................................
Typical Characteristics ..............................................
Detailed Description .............................................. 7
7.1 Overview ................................................................... 7
7.2 Functional Block Diagram ......................................... 7
7.3 Feature Description................................................... 7
7.4 Device Functional Modes........................................ 10
7.5 Programming........................................................... 10
7.6 Register Maps ......................................................... 12
8
Application and Implementation ........................ 19
8.1 Application Information............................................ 19
8.2 Typical Application .................................................. 19
9 Power Supply Recommendations...................... 21
10 Layout................................................................... 21
10.1 Layout Guidelines ................................................. 21
10.2 Layout Example .................................................... 21
11 Device and Documentation Support ................. 22
11.1
11.2
11.3
11.4
Community Resources..........................................
Trademarks ...........................................................
Electrostatic Discharge Caution ............................
Glossary ................................................................
22
22
22
22
12 Mechanical, Packaging, and Orderable
Information ........................................................... 22
4 Revision History
Changes from Revision A (December 2010) to Revision B
Page
•
Added Pin Configuration and Functions section, ESD Ratings section, Thermal Information section, Detailed
Description section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable
Information section ................................................................................................................................................................ 1
•
Deleted Trickle Charge Pump from Functional Block Diagram/Application Circuit ............................................................... 1
•
Changed Crystal series resistance maximum from 40 kΩ to 70 kΩ in Recommended Operating Conditions ...................... 4
•
Added Recommended Operating Conditions table note (1) Crystal load capacitance ±10% is allowed. ............................. 4
2
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
BQ32002
www.ti.com
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
5 Pin Configuration and Functions
D Package
8-Pin SOIC
Top View
OSCI
1
8
VCC
OSCO
2
7
IRQ
VBACK
3
6
SCL
GND
4
5
SDA
Pin Functions
PIN
NAME
NO.
TYPE
DESCRIPTION
POWER AND GROUND
VCC
8
—
Main device power
GND
4
—
Ground
VBACK
3
—
Backup device power
SERIAL INTERFACE
I2C serial interface clock
SCL
6
I
SDA
5
I/O
I2C serial data
7
O
Configurable interrupt output. Open-drain output.
OSCI
1
—
Oscillator input
OSCO
2
—
Oscillator output
INTERRUPT
IRQ
OSCILLATOR
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
3
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
6 Specifications
6.1 Absolute Maximum Ratings (1)
over operating free-air temperature range (unless otherwise noted)
MIN
MAX
VCC to GND
–0.3
4
UNIT
All other pins to GND
–0.3
VCC + 0.3
VIN
Input voltage
TJ
Operating junction temperature
–40
150
°C
Tstg
Storage temperature after reflow
–60
150
°C
(1)
V
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
6.2 ESD Ratings
VALUE
V(ESD)
(1)
(2)
Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001 (1)
2000
Charged-device model (CDM), per JEDEC specification JESD22C101 (2)
500
UNIT
V
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
6.3 Recommended Operating Conditions
MIN
VCC
Supply voltage, VCC to GND
TA
Operating free-air temperature
fo
Crystal resonant frequency
RS
Crystal series resistance
CL
Crystal load capacitance (1)
(1)
NOM
MAX
UNIT
3
3.6
V
–40
85
°C
32.768
kHz
70
12
kΩ
pF
Crystal load capacitance ±10% is allowed.
6.4 Thermal Information
BQ32002
THERMAL METRIC (1)
D (SOIC)
UNIT
8 PINS
RθJA
Junction-to-ambient thermal resistance
114.8
°C/W
RθJC(top)
Junction-to-case (top) thermal resistance
59.1
°C/W
RθJB
Junction-to-board thermal resistance
55.5
°C/W
ψJT
Junction-to-top characterization parameter
11.9
°C/W
ψJB
Junction-to-board characterization parameter
55
°C/W
(1)
4
For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report, SPRA953.
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
BQ32002
www.ti.com
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
6.5 Electrical Characteristics
over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITION
MIN
TYP
MAX
UNIT
200
μA
POWER SUPPLY
ICC
VCC supply current
VBACK
Backup supply voltage
IBACK
Backup supply current
VSO
Switchover voltage
65
Operating
Switchover
1.4
VCC
2
VCC
0.9 (1)
VCC = 0 V, VBAT = 3 V, Oscillator on, TA = 25°C
Operating → Backup
1.8
Backup → Operating
2.4
1.5
V
μA
V
LOGIC LEVEL INPUTS
VIL
Input low voltage
VIH
Input high voltage
IIN
Input current
0.3 × VCC
0.7 × VCC
0 V ≤ VIN ≤ VCC
V
V
–1
1
μA
LOGIC LEVEL OUTPUTS
VOL
Output low voltage
IL
Leakage current
IOL = 3 mA
–1
0.4
V
1
μA
REAL-TIME CLOCK CHARACTERISTICS
Pre-calibration accuracy
(1)
(2)
VCC = 3.3 V, VBAT = 3 V, Oscillator on, TA = 25°C
±35 (2)
ppm
The backup supply current is measured only after an initial power up. The device behavior is not ensured before the first power up.
Typical accuracy is measured using reference board design and KDS DMX-26S surface-mount 32.768-kHz crystal. Variation in board
design and crystal section results in different typical accuracy.
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
5
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
6.6 Timing Requirements
STANDARD MODE
PARAMETER
MIN
fscl
I2C clock frequency
0
tsch
I2C clock high time
4
2
tscl
I C clock low time
tsp
I2C spike time
tsds
I2C serial data setup time
NOM
FAST MODE
MAX
MIN
100
MAX
0
400
50
0
250
50
100
0
kHz
μs
1.3
0
UNIT
μs
0.6
4.7
2
NOM
ns
ns
tsdh
I C serial data hold time
ticr
I2C input rise time
1000
20 + 0.1Cb
(1)
0
300
ns
ticf
I2C input fall time
300
20 + 0.1Cb
(1)
300
ns
20 + 0.1Cb
(1)
300
μs
2
300
ns
tocf
I C output fall time
tbuf
I2C bus free time
4.7
1.3
μs
tsts
I2C Start setup time
4.7
0.6
μs
tsth
I2C Start hold time
4
0.6
μs
2
I C Stop setup time
tvd
(data)
Valid data time (SCL low to SDA valid)
1
1
μs
(ack)
Valid data time of ACK
(ACK signal from SCL low to SDA low)
1
1
μs
tvd
(1)
4
μs
tsps
0.6
Cb = total capacitance of one bus line in pF
6.7 Typical Characteristics
VCC = 2 V
Iback (uA)
45
20
100
Icc (uA)
107.5
90
15
80
106
70
40
10
50
35
40
30
30
ICC (uA)
60
Iback (uA)
ICC (uA)
VCC = 3.3 V
104.5
5
103
Iback (uA)
50
0
20
101.5
10
25
-10
20
0.5
1.0
1.5
2.0
Vbackup (V)
2.5
2.4
-10
2.9
3.4
Vbackup (V)
C001
Figure 1. Current Consumption vs Backup Supply Voltage
6
Iback (uA)
100
3.0
-5
Icc (uA)
0
3.9
C002
Figure 2. Current Consumption vs Backup Supply Voltage
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
BQ32002
www.ti.com
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
7 Detailed Description
7.1 Overview
The BQ32002 is a real-time clock that features an automatic backup supply with integrated oscillator-fail
detection.
7.2 Functional Block Diagram
VCC
Place supply-decoupling
capacitor near supply pin
1 µF
VCC
Automatic
Backup
Switch
VBACK
Use only
super-capacitor
or battery, not
both
.22 F
VCC
VCORE
4.7 NŸ
Interrupt
Generator
IRQ
I2C Register
Interface With
Undervoltage
Lockout
SCL
4.7 NŸ
4.7 NŸ
OSCI
32-kHz
Oscillator
SDA
OSCO
Registers
GND
Copyright © 2016, Texas Instruments Incorporated
NOTE: All pullup resistors should be connected to VCC such that no pullup is applied during backup supply operation.
7.3 Feature Description
7.3.1
IRQ Function
The IRQ pin of the BQ32002 functions as a general-purpose output or a frequency test output. The function of
IRQ is configurable in the device register space by setting the FT, FTF, and OUT bits. On initial power cycles,
the OUT bit is set to one, and the FTF and FT bits are set to zero. On subsequent power-ups, with backup
supply present, the OUT bit remains unchanged, and the FTF and FT bits are set to zero. When operating on
backup supply, the IRQ pin function is unused. IRQ pullup resistor must be tied to VCC to prevent IRQ operation
when operating on backup supply. The effect of the calibration logic is not normally observable when IRQ is
configured to output 1 Hz. The calibration logic functions by periodically adjusting the width of the 1-Hz clock.
The calibration effect is observable only every eight or sixteen minutes, depending on the sign of the calibration.
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
7
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
Feature Description (continued)
Figure 3. IRQ Pin Functional Diagram
Table 1. IRQ Function
8
FT
OUT
FTF
1
X
1
1 Hz
1
X
0
512 Hz
0
1
X
1
0
0
X
0
Submit Documentation Feedback
IRQ STATE
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
BQ32002
www.ti.com
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
7.3.2 VBACK Switchover
The BQ32002 has an internal switchover circuit that causes the device to switch from main power supply to
backup power supply when the voltage of the main supply pin VCC drops below a minimum threshold. The VBACK
switchover circuit uses an internal reference voltage VREF derived from the on-chip bandgap reference; VREF is
approximately 1.8 V. The device switches to the VBACK supply when VCC is less than the lesser of VBACK or VREF.
Similarly, the device switches to the VCC supply when VCC is greater than either VBACK or VREF.
Some registers are reset to default values when the RTC switches from main power supply to backup power
supply. See the register definitions to determine what register bits are effected by a backup switchover (effected
bits have their reset value (1/0) shown for Cycle, bits that are unchanged by backup are marked UC).
The time-keeping registers can take up to 1 second to update after the RTC switches from backup power supply
to main power supply.
V BACK > VREF
V BACK > VREF
3.3V
VB AC K
VR E F
VCC
Voltage
Voltage
VC C
–5 V/ms (max)
3.3V
VB AC K
VR E F
T ime
On VC C
Time
On V BAC K
On V BAC K
V REF > V BACK
V REF > V BACK
3.3V
3.3V
VR E F
VR E F
Voltage
VB AC K
VCC
Voltage
VB AC K
VCC
–5 V/ms (max)
T ime
On VC C
On V C C
Time
On V BAC K
On V BAC K
On V C C
Figure 4. Switchover Diagram
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
9
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
7.4 Device Functional Modes
When the device switches from the main power supply to backup supply, the time-keeping registers [0- 9] cannot
be accessed through the I2C. The access to these registers are only when VCC > VREF. The time-keeping
registers can take up to 1 second to update after the device switches from backup power supply to main power
supply.
7.5 Programming
7.5.1 I2C Serial Interface
The I2C interface allows control and monitoring of the RTC by a microcontroller. I2C is a two-wire serial interface
developed by Philips Semiconductor (see I2C-Bus Specification, Version 2.1, January 2000).
The bus consists of a data line (SDA) and a clock line (SCL) with off-chip pullup resistors. When the bus is idle,
both SDA and SCL lines are pulled high.
A master device, usually a microcontroller or a digital signal processor, controls the bus. The master is
responsible for generating the SCL signal and device addresses. The master also generates specific conditions
that indicate the START and STOP of data transfer.
A slave device receives and/or transmits data on the bus under control of the master device. This device
operates only as a slave device.
I2C communication is initiated by a master sending a start condition, a high-to-low transition on the SDA I/O while
SCL is held high. After the start condition, the device address byte is sent, most-significant bit (MSB) first,
including the data direction bit (R/W). After receiving a valid address byte, this device responds with an
acknowledge, a low on the SDA I/O during the high of the acknowledge-related clock pulse. This device
responds to the I2C slave address 11010000b for write commands and slave address 11010001b for read
commands.
This device does not respond to the general call address.
A data byte follows the address acknowledge. If the R/W bit is low, the data is written from the master. If the R/W
bit is high, the data from this device are the values read from the register previously selected by a write to the
subaddress register. The data byte is followed by an acknowledge sent from this device. Data is output only if
complete bytes are received and acknowledged.
A stop condition, which is a low-to-high transition on the SDA I/O while the SCL input is high, is sent by the
master to terminate the transfer. A master device must wait at least 60 μs after the RTC exits backup mode to
generate a START condition.
10
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
BQ32002
www.ti.com
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
Programming (continued)
ticf
SDA
ticr
tsdh
tvd
0.7 VCC
0.3 VCC
Start Condition
ticf
ticr
tsds
tsch
SCL
0.7 VCC
1
0.3 VCC
2
3
4
tscl
tsth
1/fscl
Stop Condition
tvd
SDA
0.7 VCC
tbuf
D7/A
0.3 VCC
Start Condition
tsds
SCL
0.7 VCC
8
0.3 VCC
9
tsps
Figure 5. I2C Timing Diagram
Slave
Address
(DN)
0
Sub
Address
R
(DN+1)
0 0 0
Slave
Address
ACK
0 0 0W
ACK
START
0
1
S
DataN
DataN+1
NACK
STOP
1 1
(AN)
ACK
1
ACK
START
1 1
S
Figure 6. I2C Read Mode
Figure 7. I2C Write Mode
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
11
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
7.6 Register Maps
Table 2. Normal Registers
REGISTER
ADDRESS
(HEX)
REGISTER NAME
0
0x00
SECONDS
Clock seconds and STOP bit
1
0x01
MINUTES
Clock minutes
2
0x02
CENT_HOURS
3
0x03
DAY
Clock day
4
0x04
DATE
Clock date
5
0x05
MONTH
Clock month
6
0x06
YEARS
Clock years
7
0x07
CAL_CFG1
9
0x09
CFG2
DESCRIPTION
Clock hours, century, and CENT_EN bit
Calibration and configuration
Configuration 2
Table 3. Special Function Registers
REGISTER
ADDRESS
(HEX)
REGISTER NAME
32
0x20
SF KEY 1
Special function key 1
33
0x21
SF KEY 2
Special function key 2
34
0x22
SFR
DESCRIPTION
Special function register
7.6.1 I2C Read After Backup Mode
The time-keeping registers can take up to 1 second to update after the RTC switches from backup power supply
to main power supply. An I2C read of the RTC that starts before the update has completed will return the time
when the RTC enters backup mode. To ensure that the correct time is read after backup mode, the host should
wait longer than 1 second after the main supply is greater than 2.8 V and VBACK.
12
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
BQ32002
www.ti.com
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
7.6.2 Normal Register Descriptions
Table 4. SECONDS Register
Address
Name
Initial Value
Description
D7
STOP
r/w
0
UC
STOP
10_SECOND
1_SECOND
0x00
SECONDS
0XXXXXXb
Clock seconds and STOP bit
D6
X
UC
D5
10_SECOND
r/w
X
UC
D4
D3
D2
D1
D0
X
UC
X
UC
1_SECOND
r/w
X
UC
X
UC
X
UC
BIT(S)
Name
Read/Write
Initial
Cycle
Oscillator stop. The STOP bit is used to force the oscillator to stop oscillating. STOP is set to 0 on initial application of
power, on all subsequent power cycles STOP remains unchanged. On initial power application STOP can be written to 1
and then written to 0 to force start the oscillator.
0
Normal
1
Stop
BCD of tens of seconds. The 10_SECOND bits are the BCD representation of the number of tens of seconds on the
clock. Valid values are 0 to 5. If invalid data is written to 10_SECOND, the clock will update with invalid data in
10_SECOND until the counter rolls over; thereafter, the data in 10_SECOND is valid. Time keeping registers can take up
to 1 second to update after the RTC switches from backup power supply to main power supply.
BCD of seconds. The 1_SECOND bits are the BCD representation of the number of seconds on the clock. Valid values
are 0 to 9. If invalid data is written to 1_SECOND, the clock will update with invalid data in 1_SECOND until the counter
rolls over; thereafter, the data in 1_SECOND is valid. Time keeping registers can take up to 1 second to update after the
RTC switches from backup power supply to main power supply.
Table 5. MINUTES Register
Address
Name
Initial Value
Description
D7
OF
r/w
1
0
OF
10_MINUTE
1_MINUTE
0x01
MINUTES
1XXXXXXb
Clock minutes
D6
X
UC
D5
10_MINUTE
r/w
X
UC
D4
D3
D2
D1
D0
X
UC
X
UC
1_MINUTE
r/w
X
UC
X
UC
X
UC
BIT(S)
Name
Read/Write
Initial
Cycle
Oscillator fail flag. The OF bit is a latched flag indicating when the 32.768-kHz oscillator has dropped at least four
consecutive pulses. The OF flag is always set on initial power-up, and it can be cleared through the serial interface.
When OF is 0, no oscillator failure has been detected. When OF is 1, the oscillator fail detect circuit has detected at least
four consecutive dropped pulses.
0
No failure detected
1
Failure detected
BCD of tens of minutes. The 10_MINUTE bits are the BCD representation of the number of tens of minutes on the clock.
Valid values are 0 to 5. If invalid data is written to 10_MINUTE, the clock will update with invalid data in 10_MINUTE until
the counter rolls over; thereafter, the data in 10_MINUTE is valid. Time keeping registers can take up to 1 second to
update after the RTC switches from backup power supply to main power supply.
BCD of minutes. The 1_MINUTE bits are the BCD representation of the number of minutes on the clock. Valid values are
0 to 9. If invalid data is written to 1_MINUTE, the clock will update with invalid data in 1_MINUTE until the counter rolls
over; thereafter, the data in 1_MINUTE is valid. Time keeping registers can take up to 1 second to update after the RTC
switches from backup power supply to main power supply.
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
13
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
Table 6. CENT_HOURS Register
Address
Name
Initial Value
Description
D7
CENT_EN
r/w
X
UC
CENT_EN
CENT
10_HOUR
1_HOUR
0x02
CENT_HOURS
XXXXXXXXb
Clock hours, century, and CENT_EN bit
D6
CENT
r/w
X
UC
D5
D4
D3
D2
10_HOUR
r/w
X
UC
D1
D0
X
UC
X
UC
1_HOUR
r/w
X
UC
X
UC
X
UC
BIT(S)
Name
Read/Write
Initial
Cycle
Century enable. The CENT_EN bit enables the century timekeeping feature. If CENT_EN is set to 1, then the clock
tracks the century using the CENT bit. If CENT_EN is set to 0, the clock ignores the CENT bit.
0
Century disabled
1
Century enabled
Century. The CENT bit tracks the century when century timekeeping is enabled. The clock toggles the CENT bit when
the year count rolls from 99 to 00. Because the clock compliments the CENT bit, the user can define the meaning of
CENT (1 for current century and 0 for next century, or 0 for current century and 1 for next century).
BCD of tens of hours (24-hour format). The 10_HOUR bits are the BCD representation of the number of tens of hours on
the clock, in 24-hour format. Valid values are 0 to 2. If invalid data is written to 10_HOUR, the clock will update with
invalid data in 10_HOUR until the counter rolls over; thereafter, the data in 10_HOUR is valid. Time keeping registers can
take up to 1 second to update after the RTC switches from backup power supply to main power supply.
BCD of hours (24-hour format). The 1_HOUR bits are the BCD representation of the number of hours on the clock, in 24hour format. Valid values are 0 to 9. If invalid data is written to 1_HOUR, the clock will update with invalid data in
1_HOUR until the counter rolls over; thereafter, the data in 1_HOUR is valid. Time keeping registers can take up to 1
second to update after the RTC switches from backup power supply to main power supply.
Table 7. DAY Register
Address
Name
Initial Value
Description
D7
D6
0
0
0
0
RSVD
DAY
14
0x03
DAY
00000XXXb
Clock day
D5
RSVD
r/w
0
0
D4
D3
D2
0
0
0
0
X
UC
D1
DAY
r/w
X
UC
D0
X
UC
BIT(S)
Name
Read/Write
Initial
Cycle
Reserved. The RSVD bits should always be written as 0.
BCD of the day of the week. The DAY bits are the BCD representation of the day of the week. Valid values are 1 to 7
and represent the days from Sunday to Saturday. DAY updates if set to 0 until the counter rolls over; thereafter, the data
in DAY is valid. Time keeping registers can take up to 1 second to update after the RTC switches from backup power
supply to main power supply.
1
Sunday
2
Monday
3
Tuesday
4
Wednesday
5
Thursday
6
Friday
7
Saturday
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
BQ32002
www.ti.com
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
Table 8. DATE Register
Address
Name
Initial Value
Description
D7
0x04
DATE
00XXXXXXb
Clock date
D6
D5
RSVD
r/w
0
0
RSVD
10_DATE
1_DATE
(1)
D4
D3
D2
10_DATE
r/w
0
0
X
UC
D1
D0
X
UC
X
UC
1_DATE
r/w
X
UC
X
UC
X
UC
BIT(S)
Name
Read/Write
Initial
Cycle
Reserved. The RSVD bits should always be written as 0.
BCD of tens of date. The 10_DATE bits are the BCD representation of the tens of date on the clock. Valid values are 0 to
3 (1). If invalid data is written to 10_DATE, the clock will update with invalid data in 10_DATE until the counter rolls over;
thereafter, the data in 10_DATE is valid. Time keeping registers can take up to 1 second to update after the RTC
switches from backup power supply to main power supply.
BCD of date. The 1_DATE bits are the BCD representation of the date on the clock. Valid values are 0 to 9 (1). If invalid
data is written to 1_DATE, the clock will update with invalid data in 1_DATE until the counter rolls over; thereafter, the
data in 1_DATE is valid. Time keeping registers can take up to 1 second to update after the RTC switches from backup
power supply to main power supply.
10_DATE and 1_DATE must form a valid date, 01 to 31, dependent on month and year.
Table 9. MONTH Register
Address
Name
Initial Value
Description
D7
0
0
RSVD
10_MONTH
1_MONTH
(1)
0x05
MONTH
000XXXXXb
Clock month
D6
RSVD
r/w
0
0
D5
0
0
D4
10_MONTH
r/w
X
UC
D3
D2
D1
D0
X
UC
X
UC
1_MONTH
r/w
X
UC
X
UC
BIT(S)
Name
Read/Write
Initial
Cycle
Reserved. The RSVD bits should always be written as 0.
BCD of tens of month. The 10_MONTH bits are the BCD representation of the tens of month on the clock. Valid values
are 0 to 1 (1). If invalid data is written to 10_MONTH, the clock will update with invalid data in 10_MONTH until the
counter rolls over; thereafter, the data in 10_MONTH is valid.
BCD of month. The 1_MONTH bits are the BCD representation of the month on the clock. Valid values are 0 to 9 (1). If
invalid data is written to 1_MONTH, the clock will update with invalid data in 1_MONTH until the counter rolls over;
thereafter, the data in 1_MONTH is valid.
10_MONTH and 1_MONTH must form a valid date, 01 to 12.
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
15
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
Table 10. YEARS Register
Address
Name
Initial Value
Description
D7
0x06
YEARS
XXXXXXXXb
Clock year
D6
D5
D4
D3
D2
10_YEAR
r/w
X
UC
10_YEAR
1_YEAR
X
UC
D1
D0
X
UC
X
UC
1_YEAR
r/w
X
UC
X
UC
X
UC
X
UC
BIT(S)
Name
Read/Write
Initial
Cycle
BCD of tens of years. The 10_YEAR bits are the BCD representation of the tens of years on the clock. Valid values are 0
to 9. If invalid data is written to 10_YEAR, the clock will update with invalid data in 10_YEAR until the counter rolls over;
thereafter, the data in 10_YEAR is valid. Time keeping registers can take up to 1 second to update after the RTC
switches from backup power supply to main power supply.
BCD of year. The 1_YEAR bits are the BCD representation of the years on the clock. Valid values are 0 to 9. If invalid
data is written to 1_YEAR, the clock will update with invalid data in 1_YEAR until the counter rolls over; thereafter, the
data in 1_YEAR is valid. Time keeping registers can take up to 1 second to update after the RTC switches from backup
power supply to main power supply.
Table 11. CAL_CFG1 Register
Address
Name
Initial Value
Description
D7
OUT
r/w
1
UC
OUT
FT
S
CAL
0x07
CAL_CFG1
10000000b
Calibration and control
D6
FT
r/w
0
UC
D5
S
r/w
0
UC
D4
D3
0
UC
0
UC
D2
CAL
r/w
0
UC
D1
D0
0
UC
0
UC
BIT(S)
Name
Read/Write
Initial
Cycle
Logic output, when FT = 0. When FT is zero, the logic output of IRQ pin reflects the value of OUT.
0
IRQ is logic 0
1
IRQ is logic 1
Frequency test. The FT bit is used to enable the frequency test signal on the IRQ pin. When FT is 1, a square wave is
produced on the IRQ pin. The FTF bit in the SFR register determines the frequency of the test signal.
0
Disable
1
Enable
Calibration sign. The S bit determines the polarity of the calibration applied to the oscillator. If S is 0, then the calibration
slows the RTC. If S is 1, then the calibration speeds the RTC.
0
Slowing (+)
1
Speeding (–)
Calibration. The CAL bits along with S determine the calibration amount as shown in Table 12.
Table 12. Calibration
16
CAL (DEC)
S=0
S=1
0
+0 ppm
–0 ppm
1
+2 ppm
–4 ppm
N
+N / 491520 (per minute)
–N / 245760 (per minute)
30
+61 ppm
–122 ppm
31
+63 ppm
–126 ppm
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
BQ32002
www.ti.com
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
Table 13. CFG2 Register
Address
Name
Initial Value
Description
D7
RSVD
r/w
1
1
RSVD
0x09
CFG2
10101010b
Configuration 2
D6
RSVD
r/w
0
0
D5
D4
D3
D2
RSVD
r/w
1
UC
D1
D0
1
1
0
0
RSVD
r/w
0
UC
1
1
0
0
BIT(S)
Name
Read/Write
Initial
Cycle
Reserved. The RSVD bits should always be written as 0.
7.6.3 Special Function Registers
Table 14. SF KEY 1 Register
Address
Name
Initial Value
Description
D7
0x20
SF KEY 1
00000000b
Special function key 1
D6
D5
D4
D3
D2
D1
D0
0
0
0
0
0
0
0
0
SF KEY B1
r/w
0
0
SF KEY B1
0
0
0
0
0
0
BIT(S)
Name
Read/Write
Initial
Cycle
Special function access key byte 1. Reads as 0x00, and key is 0x5E.
The SF KEY 1 and SF KEY 2 registers are used to enable access to the main special function register (SFR). Access to
SFR is granted only after the special function keys are written sequentially to SF KEY 1 and SF KEY 2. Each write to the
SFR must be preceded by writing the SF keys to the SF key registers, in order, SF KEY 1 then SF KEY 2.
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
17
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
Table 15. SF KEY 2 Register
Address
Name
Initial Value
Description
D7
0x21
SF KEY 2
00000000b
Special function key 2
D6
D5
D4
D3
D2
D1
D0
0
0
0
0
0
0
0
0
SF KEY 2
r/w
0
0
SF KEY 2
0
0
0
0
0
0
BIT(S)
Name
Read/Write
Initial
Cycle
Special function access key byte 2. Reads as 0x00, and key is 0xC7.
The SF KEY 1 and SF KEY 2 registers are used to enable access to the main special function register (SFR). Access to
SFR is granted only after the special function keys are written sequentially to SF KEY 1 and SF KEY 2. Each write to the
SFR must be preceded by writing the SF keys to the SF key registers, in order, SF KEY 1 then SF KEY 2.
Table 16. SFR Register
Address
Name
Initial Value
Description
D7
D6
D5
0
0
0
0
0
0
RSVD
FTF
18
0x22
SFR
00000000b
Special function register 1
D4
RSVD
r/w
0
0
D3
D2
D1
0
0
0
0
0
0
D0
FTF
r/w
0
0
BIT(S)
Name
Read/Write
Initial
Cycle
Reserved. The RSVD bits should always be written as 0.
Force calibration to 1 Hz. FTF allows the frequency of the calibration output to be changed from 512 Hz to 1 Hz. By
default, FTF is cleared, and the RTC outputs a 512-Hz calibration signal. Setting FTF forces the calibration signal to 1
Hz, and the calibration tracks the internal ppm adjustment. Note: The default 512-Hz calibration signal does not include
the effect of the ppm adjustment.
0
Normal 512-Hz calibration
1
1-Hz calibration
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
BQ32002
www.ti.com
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
8 Application and Implementation
NOTE
Information in the following applications sections is not part of the TI component
specification, and TI does not warrant its accuracy or completeness. TI’s customers are
responsible for determining suitability of components for their purposes. Customers should
validate and test their design implementation to confirm system functionality.
8.1 Application Information
The typical application for the BQ32002 is to provide precise time and date to a system. The backup power
supply provides additional reliability by automatically switching over from the main supply when it drops under the
voltage threshold.
8.2 Typical Application
The following design is a common application of the BQ32002.
V CC
bq32002
V CC
OSCI
32.768 kHz
1 µF
4.7 kΩ
OSCO
4.7 kΩ
4.7 kΩ
IRQ
V BACK
SCL
SDA
GND
Copyright © 2016, Texas Instruments Incorporated
Figure 8. Typical Application Schematic
8.2.1 Design Requirements
Table 17 lists the parameters for this design example.
Table 17. Design Parameters
DESIGN PARAMETER
REFERENCE
Supply Voltage
VCC
EXAMPLE VALUE
3.3 V
Backup Supply
VBACK
BR1225
Crystal Oscillator
XT
32.768 kHz
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
19
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
8.2.2 Detailed Design Procedure
8.2.2.1 Reading From a Register
The report details the read-back of the SECONDS register. Figure 9 depicts the first condition that will be used
as a benchmark to compare the values taken from the SECONDS register in the BQ32002, to the internal PC
time of the oscilloscope. In this example two modes of operation are demonstrated.
Condition 1 The main power supply, VCC, is greater than the backup power supply, VBACK, and the internal
reference voltage, VREF. In this mode, the device's internal registers are fully operational with READ
and WRITE access. Analyzing Figure 9, the known register values are compared to the system
clock; in this case, the PC clock which is shown at the bottom of the screen capture.
The BQ32002 during this condition is reading back [101][0010]= [5][2], which corresponds to
52 seconds at PC time of 2:22:43 PM.
Condition 2 VCC is now lowered to 2 V (VBACK > VCC). In this mode, the I2C communications are halted.
However, the internal time-keeping registers maintain full functional operation and accuracy which
will be available to be reliably read by the controller 1 second after the RTC switches from VBACK to
VCC supply.
Condition 3 During this final test condition, the RTC is restored to operate from the main power supply and I2C
communications are now fully functional.
Figure 10 demonstrates a read-back value from the SECONDS register of [100][0101]=
[4][5], or 45 seconds at PC time of 2:23:36 PM. This proves that the BQ32002 managed to
accurately maintain the time-keeping registers functional while the VCC dropped below VBACK.
8.2.2.2 Leap Year Compensation
The BQ32002 classifies a leap year as any year that is evenly divisible by 4. Using this rule allows for reliable
leap year compensation until 2100. Years that fall outside this rule will need to be compensated for by the
external controller.
8.2.2.3 Utilizing the Backup Supply
In order for the BQ32002 to achieve a low backup supply current as specified in the Electrical Characteristics,
the VCC pin must be initialized after every total power loss situation. Initialization Is achieved by powering on VCC
with a voltage between 3 to 3.6 V for at least 1 ms immediately after the backup supply is connected. If the VCC
is not powered on while connecting the backup supply, then the expected leakage current from VBACK will be
much greater than specified.
8.2.3 Application Curves
Figure 9. Master and Slave I2C Communication for the
SECONDS Register
20
Figure 10. Master and Slave I2C Communication for the
SECONDS Register After Recovering from the Backup
Supply
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
BQ32002
www.ti.com
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
9 Power Supply Recommendations
The BQ32002 is designed to operate from an input voltage supply, VCC, range between 3 and 3.6 V. The user
must place a minimum of 1-µF ceramic bypass capacitor rated for at least the maximum voltage as close as
possible to VCC and GND pin.
10 Layout
10.1 Layout Guidelines
The VCC pin should be bypassed to GND using a low-ESR ceramic bypass capacitor with a minimum
recommended value of 1 µF. This capacitor must be placed as close to the VCC and GND pins as possible with
thick trace or ground plane connection to the device GND pin.
Locate the 32.768-kHz crystal oscillator as close as possible to the OSCI and OSCO pins. This will minimize
stray capacitance.
10.2 Layout Example
1 µF
____
IRQ
VBACK
SCL
GND
SDA
4.7 kΩ
OSCO
4.7 kΩ
VCC
4.7 kΩ
OSCI
0.22F
Figure 11. Recommended PCB Layout
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
21
BQ32002
SLUSA96B – AUGUST 2010 – REVISED APRIL 2016
www.ti.com
11 Device and Documentation Support
11.1 Community Resources
The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective
contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of
Use.
TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration
among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help
solve problems with fellow engineers.
Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and
contact information for technical support.
11.2 Trademarks
E2E is a trademark of Texas Instruments.
All other trademarks are the property of their respective owners.
11.3 Electrostatic Discharge Caution
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
11.4 Glossary
SLYZ022 — TI Glossary.
This glossary lists and explains terms, acronyms, and definitions.
12 Mechanical, Packaging, and Orderable Information
The following pages include mechanical, packaging, and orderable information. This information is the most
current data available for the designated devices. This data is subject to change without notice and revision of
this document. For browser-based versions of this data sheet, refer to the left-hand navigation.
22
Submit Documentation Feedback
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: BQ32002
PACKAGE OPTION ADDENDUM
www.ti.com
21-Aug-2014
PACKAGING INFORMATION
Orderable Device
Status
(1)
Package Type Package Pins Package
Drawing
Qty
Eco Plan
Lead/Ball Finish
MSL Peak Temp
(2)
(6)
(3)
BQ32002D
ACTIVE
SOIC
D
8
75
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
BQ32002DR
ACTIVE
SOIC
D
8
2500
Green (RoHS
& no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
Op Temp (°C)
Device Marking
(4/5)
-40 to 85
32002
32002
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3)
MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4)
There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device.
(5)
Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation
of the previous line and the two combined represent the entire Device Marking for that device.
(6)
Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish
value exceeds the maximum column width.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
Addendum-Page 1
Samples
PACKAGE OPTION ADDENDUM
www.ti.com
21-Aug-2014
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 2
PACKAGE MATERIALS INFORMATION
www.ti.com
21-Aug-2014
TAPE AND REEL INFORMATION
*All dimensions are nominal
Device
BQ32002DR
Package Package Pins
Type Drawing
SOIC
D
8
SPQ
Reel
Reel
A0
Diameter Width (mm)
(mm) W1 (mm)
2500
330.0
12.4
Pack Materials-Page 1
6.4
B0
(mm)
K0
(mm)
P1
(mm)
5.2
2.1
8.0
W
Pin1
(mm) Quadrant
12.0
Q1
PACKAGE MATERIALS INFORMATION
www.ti.com
21-Aug-2014
*All dimensions are nominal
Device
Package Type
Package Drawing
Pins
SPQ
Length (mm)
Width (mm)
Height (mm)
BQ32002DR
SOIC
D
8
2500
367.0
367.0
35.0
Pack Materials-Page 2
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2016, Texas Instruments Incorporated
Similar pages