Lumileds LHC1-4080-1208 Uniform, high efficacy and easy-to-design array Datasheet

LUXEON CoB
Uniform, High Efficacy and Easy-to-Design Array
Introduction
Philips Lumileds high uniformity array solution is a new breakthrough in efficacy for arrays. Due to its industry leading
small Light Emitting Surfaces (LES), LUXEON CoB arrays are very easy to work with and will enable easier and less
expensive designs. All LUXEON CoBs are available in 3-Step as well as 5-Step MacAdam Ellipse, ensuring uniform
optical performance in general lighting applications. Next to that, LUXEON CoB LEDs are all hot-tested at 85°C—real
world operating conditions—which means that luminaire design is simplified and testing can be minimized.
This document contains the performance data needed to design and engineer LUXEON CoB based applications.
Features
Benefits
• Efficacy: >130 lm/W, 35.5 V
• Breakthrough in LED efficacy
• Lumen packages from 1000 to >7000 lm
• Enabling halogen and CDM replacement
• Industry smallest LES (Light Emitting Surface)
• Enables smaller and less expensive reflectors
• Industry leading thermal resistance
• Enables smaller heatsinks in your system
• Best luminous and color uniformity
• More uniform and crisp light beams
• Binned within 3-Step and 5-Step MacAdam Ellipse
• Enabling luminaire to luminaire consistency
• Tested at Tj = 85°C
• Real world application testing
• Robust MCPCB solution
• Easy to handle in manufacturing and operations
• Mouse-bites available for M2-M3 screws
• Easy to screw down the arrays
• Supported by a comprehensive optical,
• Drivers, holders and optics readily available
mechanical, and electrical ecosystem
LUXEON CoB DS115 ©2014 Philips Lumileds Lighting Company.
Table of Contents
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Average Lumen Maintenance Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Environmental Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product Performance and Characterization Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Mechanical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Characteristic Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Typical Forward Current Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Typical Relative Luminous Flux vs. Forward Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Typical Radiation Patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Color Bin Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Package Info and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
i
General Information
Product Nomenclature
LUXEON CoB is tested and binned hot at Tj = 85°C with a current pulse duration of 20ms.
The part number designation is explained as follows:
LHCA–BBCC–DDEE
Where:
A — designates the generation of the product family
B B — designates ANSI color point (e.g. 30 for 3000K)
C C — designates minimum CRI level (e.g. 80 for minimum 80 CRI)
D D E E — designates product configuration (e.g. 1203 for the 1000-2000 lm package)
Therefore 3000K, 80 CRI LUXEON CoB products will be:
LHC1–3080–1203
Average Lumen Maintenance Characteristics
Lumen maintenance for solid-state lighting devices (LEDs) is typically defined in terms of the percentage of initial
light output remaining after a specified period of time. Philips Lumileds projects that LUXEON CoB will deliver—on
average—70% lumen maintenance (L70) at 50,000 hours of operation at its nominal, tested conditions. Observation
of design limits included in this data sheet is required in order to achieve this projected lumen maintenance
Environmental Compliance
Philips Lumileds is committed to providing environmentally friendly products to the solid-state lighting market.
LUXEON CoB is compliant to the European Union directives on the restriction of hazardous substances in electronic
equipment, namely the RoHS and REACH directives. Philips Lumileds will not intentionally add the following
restricted material to the LUXEON CoB: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls
(PBB) or polybrominated diphenyl ethers (PBDE).
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
2
Product Performance and Characterization Guide
Table 1. Performance and Electrical Characteristics
CRI [1]
Nominal
CCT
Part Number
2700K
2700K
2700K
2700K
2700K
2700K
2700K
2700K
3000K
3000K
3000K
3000K
3000K
3000K
3000K
3000K
3500K
3500K
3500K
3500K
3500K
3500K
3500K
3500K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
5000K
5000K
5000K
5000K
5000K
5000K
5000K
5000K
5700K
5700K
5700K
5700K
LHC1-2780-1203
LHC1-2780-1204
LHC1-2780-1205
LHC1-2780-1208
LHC1-2790-1203
LHC1-2790-1204
LHC1-2790-1205
LHC1-2790-1208
LHC1-3080-1203
LHC1-3080-1204
LHC1-3080-1205
LHC1-3080-1208
LHC1-3090-1203
LHC1-3090-1204
LHC1-3090-1205
LHC1-3090-1208
LHC1-3580-1203
LHC1-3580-1204
LHC1-3580-1205
LHC1-3580-1208
LHC1-3590-1203
LHC1-3590-1204
LHC1-3590-1205
LHC1-3590-1208
LHC1-4070-1203
LHC1-4070-1204
LHC1-4070-1205
LHC1-4070-1208
LHC1-4080-1203
LHC1-4080-1204
LHC1-4080-1205
LHC1-4080-1208
LHC1-4090-1203
LHC1-4090-1204
LHC1-4090-1205
LHC1-4090-1208
LHC1-5070-1203
LHC1-5070-1204
LHC1-5070-1205
LHC1-5070-1208
LHC1-5080-1203
LHC1-5080-1204
LHC1-5080-1205
LHC1-5080-1208
LHC1-5770-1203
LHC1-5770-1204
LHC1-5770-1205
LHC1-5770-1208
Test Current If
Luminous Flux [1]
Minimum
Typical
(mA)
Minimum (lm)
Typical (lm)
80
80
80
80
90
90
90
90
80
80
80
80
90
90
90
90
80
80
80
80
90
90
90
90
70
70
70
70
80
80
80
80
90
90
90
90
70
70
70
70
80
80
80
80
70
70
70
70
82
82
82
82
97
97
97
97
82
82
82
82
97
97
97
97
82
82
82
82
97
97
97
97
73
73
73
73
82
82
82
82
97
97
97
97
73
73
73
73
82
82
82
82
73
73
73
73
300
450
600
900
300
450
600
900
300
450
600
900
300
450
600
900
300
450
600
900
300
450
600
900
300
450
600
900
300
450
600
900
300
450
600
900
300
450
600
900
300
450
600
900
300
450
600
900
1025
1550
2000
3050
850
1275
1700
2550
1100
1625
2200
3275
900
1325
1800
2625
1150
1725
2250
3400
925
1400
1850
2775
1225
1825
2450
3650
1175
1725
2325
3500
1000
1450
1925
2900
1225
1825
2450
3700
1175
1750
2350
3500
1225
1825
2450
3700
1125
1700
2250
3400
950
1425
1900
2850
1225
1825
2450
3650
1000
1475
2000
2950
1275
1900
2550
3800
1025
1525
2075
3075
1375
2050
2750
4100
1300
1950
2600
3900
1100
1600
2150
3200
1375
2050
2750
4100
1325
1975
2650
3950
1375
2050
2750
4100
Efficacy
Typical
(lm/W)
106
106
106
106
90
90
90
90
115
115
115
115
93
93
93
93
119
119
119
119
96
96
96
96
130
130
130
130
122
122
122
122
100
100
100
100
130
130
130
130
124
124
124
124
130
130
130
130
LES [2]
(mm)
9
13
13
15
9
13
13
15
9
13
13
15
9
13
13
15
9
13
13
15
9
13
13
15
9
13
13
15
9
13
13
15
9
13
13
15
9
13
13
15
9
13
13
15
9
13
13
15
Notes for Table 1:
1. Philips Lumileds maintains a tolerance of ±6.5% on luminous flux, ±2 on CRI.
2. Light Emitting Surface (LES) is the inner diameter (phosphor area) inside the dam.
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
3
Table 2. Optical Characteristics
Nominal
CCT
Typical Total Included Angle [1] (degrees)
Typical Viewing Angle [1]
u0.90V
2u1/2
125
100
LHC1 - xxxx - xxxx
Notes for Table 2:
1. Total angle at which 90% of total luminous flux is captured.
2. Viewing angle is the off axis angle from lamp centerline where the luminous intensity is ½ of the peak value.
Electrical Characteristics
Table 3. Electrical Characteristics
Nominal
CCT
Part
Number
2700K to 5700K
2700K to 5700K
2700K to 5700K
2700K to 5700K
2700K to 5700K
LHC1-xxxx-1202
LHC1-xxxx-1203
LHC1-xxxx-1204
LHC1-xxxx-1205
LHC1-xxxx-1208
Forward Voltage V, 85°C (V)
Minimum
Typical
Maximum
33
33
33
33
33
35.5
35.5
35.5
35.5
35.5
38
38
38
38
38
Typical Temperature
Coefficient of Forward
Voltage [1] (mV/°C)
DVF / DTJ
Typical Thermal Resistance
Junction to Case [2] (°C/W)
RuJ-C
-16
-16
-16
-16
-16
0.67
0.49
0.40
0.32
0.22
Notes for Table 3:
1. Measured between Tj = 25°C and Tj = 105°C at test current.
2. Junction temperature to back of PCB.
Absolute Maximum Ratings
Table 4. Operating Condition and Ratings
Parameter
Maximum Performance
DC Forward Current
2x test current [2]
ESD Sensitivity
< 8000V Human Body Model (HBM) Class 3A JESD22-A114-E
< 400V Machine Model (MM) Class B JESD22-A115-B
Storage Temperature
-40°C - 120°C
LED Junction Temperature [1]
125°C
Operating Case Temperature at Nominal Current
-40°C - 105°C
Reverse Voltage
LUXEON CoB is not designed to be driven in reverse bias
Notes for Table 4:
1. Proper current derating must be observed to maintain junction temperature below the maximum, please see preliminary application brief for additional information on thermal measurement
guidelines.
2. Residual periodic variations due to power conversion from alternating current (AC) to direct current (DC), also called “ripple’, with frequencies ≥ 100 Hz and amplitude ±20% are acceptable,
assuming the average current throughout each cycle does not exceed 2x test If.
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
4
Mechanical Dimensions
LUXEON CoB: LHC1 – xxxx – 1202 & 1203
R1.6
2x
LUXEON CoB: LHC1 – xxxx – 1204
R1.6
2x
16±0.2
3.5
3.5
0.1
3.5
15±0.3
2
2
+0.5
13 - 0.1
+0.5
9 - 0.1
11±0.3
4.5
8
6.5
CL
24±0.2
CL
CL
19±0.2
8
6
6.5
CL
9
0.1
2
2
3.5
2
CL
3.5
1±0.1
5
2
CL
4.5
3.5
0.5±0.2
7
1±0.1
0.5±0.2
20±0.2
LUXEON CoB: LHC1 – xxxx – 1205
R1.6
2x
4.5
LUXEON CoB: LHC1 – xxxx – 1208
3.5
4.5
R1.6
2x
3.5
0.1
15±0.3
0.1
2
+0.5
13 - 0.1
8
17±0.3
CL
CL
24±0.2
8
2
+0.5
15 - 0.1
8
CL
24±0.2
8
9
CL
9
2
2
3.5
4.5
CL
20±0.2
2
7
1±0.1
0.5±0.2
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
3.5
4.5
CL
20±0.2
7
2
1±0.1
0.5±0.2
5
Characteristic Curves
Relative Spectral Distribution vs. Wavelength
Junction Temperature = 85°C, at Test Current
Figure 1. Color spectrum of 3000K, 80 minimum CRI, integrated measurement.
Relative Light Output Characteristics over Temperature at Test Current
Figure 2. Relative light output vs. junction temperature.
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
6
Typical Forward Current Characteristics
LUXEON CoB LHC1 – xxxx – xxxx, Junction Temperature = 85°C
LUXEON CoB: LHC1 – xxxx – 1202
LUXEON CoB: LHC1 – xxxx – 1204
LUXEON CoB: LHC1 – xxxx – 1203
LUXEON CoB: LHC1 – xxxx – 1205
LUXEON CoB: LHC1 – xxxx – 1208
Figure 3. Forward current vs. forward voltage.
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
7
Typical Relative Luminous Flux vs. Forward Current
LUXEON CoB LHC1 – xxxx – xxxx, Junction Temperature = 85°C
LUXEON CoB: LHC1 – xxxx – 1202
LUXEON CoB: LHC1 – xxxx – 1204
LUXEON CoB: LHC1 – xxxx – 1203
LUXEON CoB: LHC1 – xxxx – 1205
LUXEON CoB: LHC1 – xxxx – 1208
Figure 4. Typical relative luminous flux vs. current.
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
8
Typical Radiation Patterns
Figure 5. Radiation pattern for LHC1 – xxxx – 120x.
Figure 6. Polar radiation pattern for LHC1 – xxxx – 120x.
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
9
Color Bin Definition
0.44
3 SDCM and 5 SDCM
2700K
3000K
0.42
3500K
CIE 1931 y
0.40
4000K
0.38
Black Body Locus
5000K
3-Step
0.36
5700K
5-Step
0.34
0.32
0.30
0.28
0.30
0.32
0.34
0.36
0.38
0.40
0.42
0.44
0.46
0.48
0.50
CIE 1931 x
Figure 7. 3-step and 5-step MacAdam ellipse color bins.
Table 5. 3-step and 5-step MacAdam Ellipse Color Definition
Nominal
ANSI CCT
Color Space
Center Point
(cx, cy)
Major Axis,
a
Minor Axis,
b
Ellipse
Rotation Angle
2700K
Single 3-step MacAdam ellipse
(0.4578, 0.4101)
0.00810
0.00420
53.7
3000K
Single 3-step MacAdam ellipse
(0.4338, 0.4030)
0.00834
0.00408
53.2
3500K
Single 3-step MacAdam ellipse
(0.4073, 0.3917)
0.00927
0.00414
54.0
4000K
Single 3-step MacAdam ellipse
(0.3818, 0.3797)
0.00939
0.00402
53.7
5000K
Single 3-step MacAdam ellipse
(0.3447, 0.3553)
0.00822
0.00354
59.6
Nominal
ANSI CCT
Color Space
Center Point
(cx, cy)
Major Axis,
a
Minor Axis,
b
Ellipse
Rotation Angle
2700K
Single 5-step MacAdam ellipse
(0.4578, 0.4101)
0.01350
0.00700
53.7
3000K
Single 5-step MacAdam ellipse
(0.4338, 0.4030)
0.01390
0.00680
53.2
3500K
Single 5-step MacAdam ellipse
(0.4073, 0.3917)
0.01545
0.00690
54.0
4000K
Single 5-step MacAdam ellipse
(0.3818, 0.3797)
0.01565
0.00670
53.7
5000K
Single 5-step MacAdam ellipse
(0.3447, 0.3553)
0.01370
0.00590
59.6
5700K
Single 5-step MacAdam ellipse
(0.3287, 0.3417)
0.01243
0.00533
59.09
Notes for Table 5:
1. Philips Lumileds maintains a tester tolerance of ±0.005 on x,y coordinates.
2. Major and minor axis (a,b) from table 5 are a reference as depicted in figure 7.
3. 3-step for all 80- and 90 CRI part numbers.
4. 5-step for all 70 CRI part numbers.
5. Please contact Philips Lumileds for requests outside 3-step for 80- and 90 CRI parts.
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
10
Package Info and Dimensions
Table 6. Package Info
Total Units per Tube
Total Tubes per Box
Total Units per Box
LHC1 – xxxx - 1202
LHC1 – xxxx - 1203
LHC1 – xxxx - 1204
LHC1 – xxxx - 1205
LHC1 – xxxx - 1208
20
5
100
20
5
100
20
5
100
20
5
100
20
5
100
LUXEON CoB LHC1 – xxxx - 1202 and 1203
Figure 8. Package ray dimension for LUXEON CoB LHC1 – xxxx - 1202 and 1203.
LUXEON CoB LHC1 – xxxx – 1204, -1205 and -1208
Figure 9. Package ray dimension for LUXEON CoB LHC1 – xxxx – 1204, - 1205 and - 1208.
LUXEON CoB Datasheet DS115 20140328 ©2014 Philips Lumileds Lighting Company.
11
Who We Are
Philips Lumileds focuses on one goal: Creating the world’s highest performing LEDs. The company pioneered the use
of solid-state lighting in breakthrough products such as the first LED backlit TV, the first LED flash in camera phones,
and the first LED daytime running lights for cars. Today we offer the most comprehensive portfolio of high quality
LEDs and uncompromising service.
Philips Lumileds brings LED’s qualities of energy efficiency, digital control and long life to spotlights, downlights,
high bay and low bay lighting, indoor area lighting, architectural and specialty lighting as well as retrofit lamps. Our
products are engineered for optimal light quality and unprecedented efficacy at the lowest overall cost. By offering
LEDs in chip, packaged and module form, we deliver supply chain flexibility to the inventors of next generation
illumination.
Philips Lumileds understands that solid state lighting is not just about energy efficiency. It is about elegant design.
Reinventing form. Engineering new materials. Pioneering markets and simplifying the supply chain. It’s about a
shared vision. Learn more about our comprehensive portfolio of LEDs at www.philipslumileds.com.
RoHS
No. E352519
COMPLIANT
Philips Lumileds Lighting Company shall not be liable for any kind of loss of data or any other damages, direct, indirect or consequential, resulting from the use of the provided information and data. Although
Philips Lumileds Lighting Company has attempted to provide the most accurate information and data, the materials and services information and data are provided “as is” and Philips Lumileds Lighting Company
neither warranties, nor guarantees the contents and correctness of the provided information and data. Philips Lumileds Lighting Company reserves the right to make changes without notice.
You as user agree to this disclaimer and user agreement with the download or use of the provided materials, information and data.
©2014 Philips Lumileds Lighting Company. All rights reserved.
LUXEON is a registered trademark of the Philips Lumileds Lighting
Company in the United States and other countries.
www.philipslumileds.com
www.philipslumileds.cn.com
LUXEON CoB Datasheet DS115 20140328