MCC MURX0520 0.5 amp super fast recovery rectifier 100 to 600 volt Datasheet

MCC
MURX0510
THRU
MURX0560
omponents
21201 Itasca Street Chatsworth
!"#
$ % !"#
Features
•
•
•
•
•
0.5 Amp Super Fast
Recovery Rectifier
100 to 600 Volts
For Surface Mount Application
Low Leakage
Low Forward Voltage Drop
Extremely Low Thermal Resistance
Super Fast Recovery Time For High Efficiency
Maximum Ratings
•
•
•
SOD-123
Operating Temperature: -40к to +150к
Storage Temperature: -40к to +150к
Maximum Thermal Resistance: 200к/W Junction to Ambient
Maximum
DC
Blocking
Voltage
MCC
Part Number
Device
Marking
Maximum
Recurrent
Peak Reverse
Voltage
MURX0510
U1
100V
70V
100V
MURX0520
U2
200V
140V
200V
MURX0530
U3
300V
210V
300V
MURX0540
U4
400V
280V
400V
MURX0550
U5
500V
350V
500V
MURX0560
U6
600V
420V
600V
Maximum
RMS
Voltage
A
B
C
E
H
D
DIM
Electrical Characteristics @ 25к Unless Otherwise Specified
Average Forward
Current
IF(AV)
0.5 A
TL = 115к
Peak Forward Surge
Current
IFSM
8.0A
8.3ms, half sine
Maximum
Instantaneous
Forward Voltage
VF
1.35V
IFM =0.5A;
TA = 25к
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR
5.0µA
TA = 25к
Maximum Reverse
Recovery Time
Trr
75ns
IF=0.5A, IR=1.0A,
Irr=0.25A
Typical Junction
Capacitance
CJ
10pF
Measured at
1.0MHz, VR=4.0V
J
G
A
B
C
D
E
G
H
J
DIMENSIONS
INCHES
MM
MIN
MAX
MIN
MAX
.140
.152
3.55
3.85
.100
.112
2.55
2.85
.055
.071
1.40
1.80
----.053
----1.35
.012
.031
0.30
.78
.006
----0.15
--------.01
----.25
----.006
----.15
SUGGESTED SOLDER
PAD LAYOUT
0.093”
0.048”
*Pulse Test: Pulse Width 300µsec, Duty Cycle 2%
www.mccsemi.com
0.036”
NOTE
MCC
MURX0510 thru MURX0560
Figure 1
Typical Forward Characteristics
2.0
Figure 2
Forward Derating Curve
1.0
.6
.6
.4
.5
.2
25°C
Amps
.4
.1
.06
.3
Amps
.04
.2
.02
.01
.1
Single Phase, Half Wave
60Hz Resistive or Inductive Load
.006
0
.004
50
75
100
125
175
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
.6
.4
.8
1.0
1.2
1.4
Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
10
6
TJ=25°C
4
2
pF
150
°C
.002
.001
0
1
.6
.4
.2
.1
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
400
Junction Capacitance - pF versus
Reverse Voltage - Volts
www.mccsemi.com
1000
MCC
MURX0510 thru MURX0560
Figure 4
Typical Reverse Characteristics
Figure 5
Peak Forward Surge Current
100
9.0
60
40
7.5
TA=150°C
20
6.0
10
4.5
6
Amps
4
3.0
1.5
2 TA=100°C
0
µAmps 1
1
4
2
6
.6
8 10
20
40
60 80 100
Cycles
.4
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
.2
TA=25°C
.1
.06
.04
.02
.01
2
60
4
80
100
120
140
Volts
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 6
Reverse Recovery Time Characteristic And Test Circuit Diagram
50Ω
10Ω
trr
+0.5A
0
Pulse
Generator
Note 2
25Vdc
1Ω
Notes:
1. Rise Time = 7ns max.
Input impedance = 1 megohm, 22pF
2. Rise Time = 10ns max.
Source impedance = 50 ohms
3. Resistors are non-inductive
Oscilloscope
Note 1
-0.25
1.0
1cm
Set Time Base for 20/100ns/cm
www.mccsemi.com
Similar pages