AIMTEC AM30K-4805S-NZ 30 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM30K-NZ
30 Watt | DC-DC Converter
FEATURES:








RoHS compliant
Remote On/Off control
High Efficiency up to 90%
Input Under voltage protection
Trim adjustment
Power modules for PCB mounting
Operating temperature range: -40 to +85ºC
Standard package
Models
Single output
Model
Input Voltage
(V)
Output
Voltage
(V)
18 – 36
18 – 36
18 – 36
18 – 36
36 – 75
36 – 75
36 – 75
36 – 75
5
12
15
24
5
12
15
24
AM30K-2405S-NZ
AM30K-2412S-NZ
AM30K-2415S-NZ
AM30K-2424S-NZ
AM30K-4805S-NZ
AM30K-4812S-NZ
AM30K-4815S-NZ
AM30K-4824S-NZ
Output Current
max (A)
Maximum
capacitive load
(µF)
Efficiency
(%)
10200
3240
1100
900
10200
3240
1100
900
88
89
89
88
89
90
90
90
6
2.5
2
1.25
6
2.5
2
1.25
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input
voltage and at rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
Typical
12
24
48
Filter
Start up time
Absolute Maximum Rating
Under Voltage protection
Units
VDC
ms
20
40
VDC
80
100
ms
3.5 to 12VDC or open circuit
0 to 1.2VDC or short circuit between pin 2 and 3
8
16
VDC
33
12 Vin
24 Vin
48 Vin
Peak Input Voltage time
Remote On/Off Control
Maximum
9-18
18-36
36-75
(Pi) Network
25
On
Off
9-18 Vin OFF
18-36 Vin OFF
36-75 Vin OFF
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R8.J
Conditions
Typical
60 sec
At 500Vdc
100KHz / 1V
>1000
1000
Tel: +1 514 620 2722
1 of 3
Rated
Units
1500
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30K-NZ
30 Watt | DC-DC Converter
Output Specifications
Parameters
Conditions
Voltage accuracy
Line voltage regulation
Load voltage regulation
Short Circuit protection
Short Circuit restart
Over current protection
Temperature coefficient
Ripple & Noise
Transient Response Recovery
Time
Transient response overshoot
Voltage adjustment range
Typical
Maximum
±1
±0.2
±0.5
Continuous
Auto Recovery
>120
0.02
100
200
LL-HL
10% to 100% Load
Input Voltage Range
20MHZ Bandwidth
25% load step change
Units
%
% of Vin
%
160
%
%/oC
mV p-p
μs
±2
±10
±5
% of Vout
%
Typical
Maximum
Units
95
KHz
oC
oC
oC
95
%
General Specifications
Parameters
Conditions
Switching frequency
Operating temperature
Storage temperature
Case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L X W X H)
MTBF
100% load
With derating above +71°C
Tolerance ±0.5mm
g
50.80 x 40.60 x 11.10mm
Dimensions
50.80
(2.00)
4
2
5
3
2.54
(0.10)
Printed Face
Bottom View
10.16
(0.40)
1
6
45.72
(1.80)
5.10 10.16
(0.20) (0.40)
7.62 10.16 5.08
(0.30) (0.40) (0.20)
+V Input
-V Input
On/Off Control
+V Output
-V Output
Trim
Black Anodized Aluminum
45
2.00 x 1.60 x 0.44 inches
>1 000 000 hrs
40.60
(1.60)
Single
1
2
3
4
5
6
-40 to +85
-55 to +105
Free air convection
Pin Out Specifications
Pin
300
2.54
(0.10)
4.10
(0.16)
11.10
(0.44)
Dimensions mm (inch)
Case Tolerance ±0.50 (±0.02)
Pin Pitch Tolerance ±0.35 (±0.014)
Ø 1.50
(0.06)
www.aimtec.com
F 051e R8.J
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30K-NZ
30 Watt | DC-DC Converter
Trimming
Derating
Free Air Convection
71ºC
Output Power (%)
100
80
60
Safe Operating Area
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
Recommended EMI Filtering (if required by end application)
Note: should your application not require filtering, no additional circuits are required.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R8.J
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages