AIMTEC AM6TW-4807D-RZ 6 watt | dc-dc converter Datasheet

Series AM6TW-RZ
6 Watt | DC-DC Converter
FEATURES:
• RoHS compliant
• 24 Pin DIP Package
• Wide 4:1 input range
• High efficiency up to 85%
Models
Single output
Model
AM6TW-2403S-RZ
AM6TW-2405S-RZ
AM6TW-2407S-RZ
AM6TW-2409S-RZ
AM6TW-2412S-RZ
AM6TW-2415S-RZ
AM6TW-2418S-RZ
AM6TW-2424S-RZ
AM6TW-4803S-RZ
AM6TW-4805S-RZ
AM6TW-4807S-RZ
AM6TW-4809S-RZ
AM6TW-4812S-RZ
AM6TW-4815S-RZ
AM6TW-4818S-RZ
AM6TW-4824S-RZ
Input
Voltage (V)
9-36
9-36
9-36
9-36
9-36
9-36
9-36
9-36
18-72
18-72
18-72
18-72
18-72
18-72
18-72
18-72
AM6TW-2403D-RZ
AM6TW-2405D-RZ
AM6TW-2407D-RZ
AM6TW-2409D-RZ
AM6TW-2412D-RZ
AM6TW-2415D-RZ
AM6TW-2418D-RZ
AM6TW-2424D-RZ
AM6TW-4803D-RZ
AM6TW-4805D-RZ
AM6TW-4807D-RZ
AM6TW-4809D-RZ
AM6TW-4812D-RZ
AM6TW-4815D-RZ
AM6TW-4818D-RZ
AM6TW-4824D-RZ
Input Specifications
Parameters
Voltage range
Filter
Turn on Transient process time
www.aimtec.com
F 051e R12.E
Input
Voltage (V)
9-36
9-36
9-36
9-36
9-36
9-36
9-36
9-36
18-72
18-72
18-72
18-72
18-72
18-72
18-72
18-72
Output Current
max (mA)
Isolation
(VDC)
1400
1200
830
660
500
400
330
250
1400
1200
830
660
500
400
330
250
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
Output
Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
±700
±600
±410
±330
±250
±200
±165
±125
±700
±600
±410
±330
±250
±200
±165
±125
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
±3.3
±5
±7.2
±9
±12
±15
±18
±24
±3.3
±5
±7.2
±9
±12
±15
±18
±24
Nominal
24
48
Operating temperature -40 to + 85oC
Input / Output Isolation 1500VDC
Pin compatible with multiple manufacturers
Continuous short circuit protection
Output
Voltage
(V)
3.3
5
7.2
9
12
15
18
24
3.3
5
7.2
9
12
15
18
24
Models
Dual output
Model
•
•
•
•
Typical
9-36
18-72
Tel: +1 514 620 2722
1 of 3
Maximum
Max
Capacitive
Load(uF)
Efficiency
(%)
1000
1000
470
220
1000
470
47
47
1000
1000
470
220
1000
100
10
22
75
81
82
82
83
83
83
82
75
81
82
82
82
85
83
83
Max
Capacitive
Load(uF)
Efficiency
(%)
±470
±680
±220
±100
±330
±100
±10
±22
±330
±470
±220
±100
±100
±47
±22
±22
80
82
82
82
84
80
80
81
79
82
81
81
83
81
81
81
Units
VDC
π (Pi) Network
350
ms
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6TW-RZ
6 Watt | DC-DC Converter
Input Specifications (continued)
Parameters
Start up time
Absolute Maximum Rating
Peak Input Voltage time
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Output Specifications
Parameters
Voltage accuracy
Voltage balance
Short Circuit protection
Short circuit restart
Over current protection
Line voltage regulation (Single)
Line voltage regulation (Dual)
Load voltage regulation (Single)
Load voltage regulation (Single)
3.3V output model
Load voltage regulation (Dual)
Load voltage regulation (Dual) ±
Temperature coefficient
Ripple & Noise
Rising time
General Specifications
Parameters
Nominal
24 Vin
48 Vin
Conditions
3 sec
Conditions
0 – 100% load
0 – 100% load
0 – 100% load
0 – 100% load
At 20MHz
Bandwidth
Conditions
Typical
Maximum
500
-0.7-40
-0.7-80
100
ms
Rated
1500
> 1000
500
Typical
±0.5
±0.5
±0.5
±1.5
ms
VDC
Typical
±1
±1
Units
Maximum
Continuous
Auto Recovery
120% Iout
Units
VDC
MOhm
pF
Units
%
%
%
%
%
%
±0.5
±1.5
±0.02
60
%
%
%/oC
mV p-p
10
ms
Typical
Maximum
Units
Switching frequency
100% load
260
KHz
o
Operating temperature
Full Load without Derating
-40 to +85
C
o
Storage temperature
-40 to +125
C
o
Max Case temperature
+100
C
Cooling
Free air convection
Humidity
90
%
Case material
Nickel coated copper
Weight
26
g
Dimensions (L x W x H)
Tolerance ±0.5 mm or ±0.02 inches 1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm
MTBF
>1 050 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Parameters
Agency Approval
Standards
www.aimtec.com
F 051e R12.E
CE
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B
IEC61000-4-5, Perf. Criteria B
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
NOTE: also designed to meet IEC 60950-1:2001
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6TW-RZ
6 Watt | DC-DC Converter
Pin Out Specifications
Pin
1
2
3
9
10
11
12/13
14
15
16
22
23
24
Single
Omitted
-V Input
-V Input
Omitted
Omitted
N.C.
Omitted
+V Output
Omitted
-V Output
+V Input
+V Input
Omitted
Dual
Omitted
-V Input
-V Input
Common
Omitted
-V Output
Omitted
+V Output
Omitted
Common
+V Input
+V Input
Omitted
Dimensions
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages