AIMTEC AMEL5-AZ 5 watt | ac-dc / dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
FEATURES:




I/O Isolation 3000VAC
Operating Temp: -40 oC to +95 oC
Input: 90-305VAC, 47-440Hz, or 130-430VDC
Over load, Over Voltage, Short Circuit Protection




RoHS compliant
Energy Star compliant
Efficiency up to 76%
Soft start
Models
Single output
Model
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Temperature
range
(ºC)
Output
Voltage
(V)
Output
Current
max (A)
Maximum
capacitive
Load
(µF)
Efficiency
(%)
115
VAC
230
VAC
277
VAC
AMEL5-3.3SAZ
90-305/47-440
130-430
-40 to +95
3.3
1. 5
2200
71
71
69
AMEL5-5SAZ
90-305/47-440
130-430
-40 to +95
5
1
1100
72
73
72
AMEL5-12SAZ
90-305/47-440
130-430
-40 to +95
12
0.42
680
75
76
76
AMEL5-15SAZ
90-305/47-440
130-430
-40 to +95
15
0.333
330
75
75
73
AMEL5-24SAZ
90-305/47-440
130-430
-40 to +95
24
0.21
220
75
76
75
Note: 1. Optional mounting plate version can be ordered by adding “-ST” suffix to part number (ex. AMEL5-5SAZ-ST);
2. Optional version with incorporated filter for Earth to Ground connection can be ordered by adding “G” to the model suffix (ex.
AMEL5-5SGAZ).
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Start-up time
Conditions
Typical
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC







1.5
≦0.2
150
Recommended slow blow type
(110/230/277 VAC)
115 VAC/ Full Load
Maximum
120
80
70
15
30
40
0.2
Units
mA
mA
mA
A
A
A
mA
A
W
ms
Output Specifications
Parameters
Conditions
Typical
Maximum
Voltage accuracy
Line regulation
Load regulation
Transient recovery time
Transient response deviation
±2
±1
0-100% load
±1
200
25% load step
±2
3.3/5V models
75
Ripple & Noise*
12/15V models
100
24V models
150
Hold-up time
5
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1µF (M/C) and 47µF (E/C) parallel capacitor.
Units
%
%
%
µs
% of Vout
mV p-p
mV p-p
mV p-p
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
www.aimtec.com
F 052e R8.O
Conditions
Typical
60 sec
>1000
Tel: +1 514 620 2722
1 of 5
Rated
Units
3000
VAC
MΩ
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
Over load protection
Over voltage protection
Short circuit protection
Operating temperature
Storage temperature
Maximum case temperature
Temperature coefficient
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
66
KHz
Foldback
130
%
Zener Diode Clamp
Auto recovery
oC
With derating over 60ºC, see chart
Refer to model application
oC
-40 to +95
oC
100
0.02
% / oC
Free air convection
Non condensing
20 ~ 95
% RH
Plastic (flammability to UL 94V-0)
30
g
51.50 x 28.00 x 17.80mm (2.03 x 1.10 x 0.70inches)
> 400,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load
MTBF
> 100,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Environment Approval
Test
Shock
Vibrations
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30ms
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 052e R8.O
cULus for all models CE, CB (not including suffix “GAZ” models)
Information technology Equipment
IEC\EN\UL 60950-1
Information technology Equipment
EN 60950-1:2006+A11:2009
EMI - Conducted and radiated emission
EN55022, class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Air level 3, Contact level 2
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 2
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
Additional Surge Protective Circuitry
The AMEL5-AZ series design level surge protection is certified to IEC 61000-4-5 surge Line to Line of 1KV. However greater
protection can be enhanced by adding protective devices to ingress circuitry. For example, by adding an MOV (Metal Oxide
Varistor) device example S14K320E2 to the N / L input lines 2KV surge protection or greater, can be achieved.
MOV PN
Vrms
V
Vdc
V
Wmax (2ms)
J
Pmax
W
S14K320E2
320
420
136
0.6
Pin Out Specifications
Pin
Single
1
2
3
4
5
AC Input (N)
AC Input (L)
+V Output
-V Output
No pin
Dimensions
2.03
(51.50)
1.80
(45.72)
1
1
3
3
0.40
(10.16)
1.10
0.80
(28.00) (20.32)
TOP VIEW
TOP VIEW
4
4
0.40
(10.16)
2
2
5
5
0.11
(2.89)
17.80
(0.70)
5 Ø- 0.047 (Ø 1.2)
Ø 0.04
(1.00)
Dimensions: inch (mm)
Case Tolerance:± 0.012 (0.30)
Pin Pitch Tolerance: ± 0.012 (0.30)
0.2
(5.08)
(Min)
www.aimtec.com
F 052e R8.O
DIV: 0.2 (5.08)
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
Derating
Earth/Ground Connection for AMEL5-xxSGAZ models
L
+Vout
100-277VAC
AMEL5‐xxSGAZ
N
-Vout
AMEL5‐xxSGAZ models meet the EN55022 class B compliance when connected to Earth/Ground. These models are
incorporating an EMC compliant filter and when connected to Earth/GND, no external filtering will be needed to meet the
specified limits.
Models include: AMEL5‐3.3SGAZ, AMEL5‐5SGAZ, AMEL5‐12SGAZ, AMEL5‐15SGAZ, and AMEL5‐24SGAZ
www.aimtec.com
F 052e R8.O
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMEL5-AZ
5 Watt | AC-DC / DC-DC Converter
Dimensions of Optional ST Mounting Plate Version
Pin Out Specification ST Version
86.00
38.00
25.00
70.00
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8.O
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages