AIMTEC AMER90-36250CAZ Constant current led driver or converter Datasheet

Click on Series name for product info on aimtec.com
Series AMER90-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:







Models
Single output
Constant current LED Driver or Converter
Input range 90-305VAC/47-440Hz
High Efficiency up to 88%
115VAC Operating temperature -50 to 85°C
230VAC Operating temperature -55 to 85°C
Dimmable via resistive
5 Years Limited Warranty
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
AMER90-50180CAZ
90
36-50
1.8
90-305/47-440
130-430
AMER90-36250CAZ
90
24-36
2.5
90-305/47-440
130-430
AMER90-24375CAZ
90
12-24
3.75
90-305/47-440
130-430
Model
Add suffix “-F”





Over Temperature Protection
Waterproof Case rated IP68
Power Factor Correction
Short Circuit Protection
Over Current Protection
Mode of Operation
Efficiency
(%)
115
230
277
VAC
VAC
VAC
Constant Current
Constant Voltage②
Constant Current
87
88
86
87
86
87
87
87
87
Constant Voltage②
Constant Current
88
87
87
86
86
86
Constant Voltage②
87
86
86
No dimming option
①
Exceeding the maximum output power will permanently damage the converter.
②
The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming
option in the case.
③
In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All
models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMER90-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms(cold start)
Leakage current
Power factor
External fuse
Start-up time
www.aimtec.com
F 052.1e R3.N
Conditions
Typical
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
Maximum
1500
600
500
40
50
60
0.25
3.5
0.98
0.94
0.90
2.5
1000
Tel: +1 514 620 2722
1 of 10
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Current accuracy
±3
%
Line regulation
(LL-HL)
±2
%
Load regulation
0-100% load
±3
%
Ripple & Noise*
150
mV p-p
Hold-up time
100
ms
100-10
%
Current adjustment range⑤
④Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
⑤Note: from 0% to 10% dimming adjustment signal instability may be present.
Isolation Specifications
Parameters
Tested voltage
Conditions
I/O
I/FG
O/FG
Isolation resistance
Typical
3sec
500VDC
Rated
Units
3750
2000
500
VAC
VAC
VAC
MΩ
>1000
General Specifications
Parameters
Conditions
Typical
Maximum
Units
125
1.87
2.57
3.8
KHz
Switching frequency
Over current protection
Over current protection
Over voltage protection
Short circuit protection
Short circuit restart
Over temperature protection
Operating temperature
(See Derating Table)
Cold Start-up Time
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting
Wires
Weight
Dimensions (L X H X W)
MTBF
AMER90-50180CAZ
AMER90-36250CAZ
AMER90-24375CAZ
≧105
Refer to Constant Current vs. Constant Voltage Mode curve
Continuous
Auto recovery
>105°C
(115VAC)
-50 to +85
(230VAC)
-55 to +85
-55°C
%
oC
oC
35
100
Sec
oC
oC
% / oC
95
% RH
-55 to +95
±0.02
Free air convection
Aluminum
Epoxy (IP68 rated)
UL1015 18AWG Input & 14AWG Output *20CM
900
7.13 x 2.32 x 1.85 inches
181.00 x 59.00 x 47.00 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
A
g
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 052.1e R3.N
UL, CE
UL8750, UL60950-1, EN55022, class B, EN60529(IP68)
Information Technology Equipment
EN55022 Class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient / Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 3
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 1
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Dimensions
Wire connection:
Wire
Brown
Blue
Green
Red
Black
Blue (Dimming)
White (Dimming)
Connection
AC L
AC N
Ground
+V output
-V Output
+ Vs dimming
-Vs dimming
Analog (resistive) Dimming Application Circuit
Model Number
AMER90-50180CAZ
AMER90-36250CAZ
AMER90-24375CAZ
www.aimtec.com
F 052.1e R3.N
Tel: +1 514 620 2722
3 of 10
Maximum Pot
Value (kΩ)
11.70
16.95
28.09
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Analog (0-10V) Dimming Application Circuit
PWM (1KHz) Dimming Application Circuit
Temperature graph
Free Air Convection
55 º C
100
80
Safe Operating Area
60
40
20
0
-40
-20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 052.1e R3.N
Tel: +1 514 620 2722
4 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Efficiency vs. Input Voltage and Output Current (CC mode)
AMER90-50180CAZ
AMER90-36250CAZ
www.aimtec.com
F 052.1e R3.N
Tel: +1 514 620 2722
5 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Efficiency vs. Input Voltage and Output Current (CC mode)
AMER90-24375CAZ
PFC Value vs. Output Load Current (CC mode)
AMEPR90-50180CAZ
www.aimtec.com
F 052.1e R3.N
Tel: +1 514 620 2722
6 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
PFC Value vs. Output Load Current (CC mode)
AMER90-36250CAZ
AMER90-24375CAZ
www.aimtec.com
F 052.1e R3.N
Tel: +1 514 620 2722
7 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Constant Current Mode vs. Constant Voltage Mode
AMER90-50180CAZ
AMER90-36250CAZ
www.aimtec.com
F 052.1e R3.N
Tel: +1 514 620 2722
8 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Constant Current Mode vs. Constant Voltage Mode
AMER90-24375CAZ
Output Current vs. Radj
AMER90-50180CAZ
www.aimtec.com
F 052.1e R3.N
Tel: +1 514 620 2722
9 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER90-CAZ
up to 3.75A | AC-DC / DC-DC | LED Driver / Converter
Output Current vs. Radj
AMER90-36250CAZ
AMER90-24375CAZ
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R3.N
Tel: +1 514 620 2722
10 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages