Aluminum electrolytic capacitors Single-ended capacitors Series/Type: B41851, B43851 Date: January 2009 © EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Single-ended capacitors B41851, B43851 Standard series 105 °C General-purpose grade capacitors Applications General-purpose applications in the entertainment industry Semi-professional to professional application range For filtering, coupling and pulse circuits Switch-mode power supplies Features Compact dimensions High CV product, i.e. very compact RoHS-compatible Construction Radial leads Charge-discharge proof, polar Aluminum case with insulating sleeve Minus pole marking on the insulating sleeve Case with safety vent from diameter 6.3 mm Delivery mode Terminal configurations and packing: Bulk Taped, Ammo pack Cut Kinked PAPR (protection against polarity reversal): crimped leads, J leads, bent leads Refer to chapter "Single-ended capacitors Taping, packing and lead configurations" for further details and ordering example. Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 36 B41851, B43851 Standard series 105 °C Specifications and characteristics in brief Series Rated voltage VR Surge voltage VS Rated capacitance CR Capacitance tolerance B41851 6.3 ... 100 V DC 1.15 VR 0.1 ... 10000 µF ±20% M B43851 160 ... 450 V DC 1.1 VR 0.47 ... 680 µF ±20% M Dissipation factor tan δ (20 °C, 120 Hz) For capacitance higher than 1000 µF add 0.02 for every increase of 1000 µF. VR (V DC) 6.3 10 16 25 35 50 63 100 160 ... 450 tan δ (max.) 0.28 0.24 0.20 0.16 0.14 0.12 0.12 0.10 0.20 Leakage current Ileak (20 °C, 5 min) Self-inductance ESL Useful life 105 °C; VR; IAC,R 40 °C; VR; 1.8 IAC,R 40 °C; VR; 2.1 IAC,R Requirements Voltage endurance test 105 °C; VR Post test requirements or 3 µA, whichever is greater Diameter (mm) ≤ 6.3 8 ... 12.5 16 18 20 ... 25 ESL (nH) 26 34 40 15 20 > 2000 h > 250000 h ∆C/C tan δ Ileak > 3000 h > 250000 h ≤ ±45% of initial value ≤ 3 times initial specified limit ≤ initial specified limit 1000 h ∆C/C tan δ Ileak 1000 h ≤ ±30% of initial value ≤ 2 times initial specified limit ≤ initial specified limit Vibration resistance test To IEC 60068-2-6, test Fc: Displacement amplitude 1.5 mm, frequency range 10 ... 2000 Hz, acceleration max. 20 g, duration 3 × 2 h. Capacitor rigidly clamped by the aluminum case. IEC climatic category To IEC 60068-1: VR ≤ 250 V: 40/105/56 (40 °C/+105 °C/56 days damp heat test) VR ≥ 350 V: 25/105/56 (25 °C/+105 °C/56 days damp heat test) Sectional specification IEC 60384-4 Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 36 B41851, B43851 Standard series 105 °C Dimensional drawings With stand-off rubber seal Diameters (mm): 6.3, 10, 12.5, 16, 18, 22, 25 With flat rubber seal Diameters (mm): 5, 8, 20 Safety vent for diameter ≥6.3 mm. Dimensions and weights Dimensions (mm) d +0.5 5 6.3 8 10 10 10 12.5 12.5 16 16 16 18 18 18 20 20 22 25 l 11 +1.0 11 +1.0 11.5 +1.5 12.5 +1.0 16 +1.0 20 +2.0 20 +2.0 25 +2.0 20 +2.0 25 +2.0 31.5 +2.0 31.5 +2.0 35 +2.0 40 +2.0 35 +2.0 40 +2.0 40 +2.0 40 +2.0 Please read Cautions and warnings and Important notes at the end of this document. a ±0.5 2.0 2.5 3.5 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 10.0 10.0 10.0 12.5 Page 4 of 36 b 0.50 ±0.05 0.50 ±0.05 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.60 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.05 0.80 ±0.1 0.80 ±0.1 0.80 ±0.1 1.0 ±0.1 1.0 ±0.1 1.0 ±0.1 1.0 ±0.1 Approx. weight g 0.5 0.7 1.0 1.6 1.9 2.6 3.6 4.5 5.5 7.5 7.8 11.0 13.0 16.0 18.0 20.0 23.0 25.0 B41851 Standard series 105 °C Overview of available types B41851 Other voltage and capacitance ratings are available upon request. VR (V DC) 6.3 10 16 25 Case dimensions d × l (mm) CR (µF) 47 5 × 11 68 5 × 11 100 5 × 11 5 6.3 × 11 × 11 8 × 11.5 8 × 11.5 8 10 × 11.5 × 12.5 × 11.5 8 × 11.5 10 × 12.5 × 12.5 10 × 12.5 10 × 16 10 × 12.5 10 × 16 10 × 20 × 16 10 × 20 10 × 20 12.5 × 20 10 × 20 10 × 20 12.5 × 20 12.5 × 25 10 × 20 12.5 × 25 12.5 × 25 16 × 25 16 × 25 220 330 6.3 × 11 470 8 680 8 1000 6.3 × 11 6.3 × 11 8 × 11.5 × 11.5 8 × 11.5 10 10 × 12.5 1500 10 2200 3300 4700 12.5 × 25 16 × 20 16 × 25 16 × 31.5 6800 16 × 25 16 × 31.5 18 × 35 10000 18 × 31.5 18 × 35 20 × 40 Please read Cautions and warnings and Important notes at the end of this document. Page 5 of 36 B41851 Standard series 105 °C VR (V DC) 35 50 63 100 Case dimensions d × l (mm) CR (µF) 0.10 5 × 11 0.22 5 × 11 0.33 5 × 11 0.47 5 × 11 0.68 5 × 11 1.0 5 × 11 5 × 11 2.2 5 × 11 5 × 11 3.3 5 × 11 5 × 11 4.7 5 × 11 5 × 11 5 × 11 5 × 11 6.3 × 11 5 × 11 5 10 × 11 8 × 11.5 33 5 × 11 6.3 × 11 6.3 × 11 8 10 × 11.5 × 12.5 47 5 × 11 6.3 × 11 6.3 × 11 10 × 12.5 68 6.3 × 11 6.3 × 11 8 × 11.5 10 × 16 100 6.3 × 11 8 × 11.5 8 × 11.5 10 × 20 220 8 × 11.5 10 × 12.5 10 × 16 12.5 × 25 330 10 × 12.5 10 × 16 10 × 20 16 × 25 470 10 × 16 10 × 20 12.5 × 20 16 × 31.5 680 10 × 20 12.5 × 20 16 × 20 18 × 40 1000 12.5 × 20 12.5 × 25 16 × 25 18 × 40 1500 16 × 20 16 × 25 18 × 31.5 2200 16 × 25 16 18 × 31.5 × 35 18 × 35 3300 16 × 31.5 18 × 35 20 × 40 4700 18 × 35 20 × 40 25 × 40 6800 18 × 40 22 Please read Cautions and warnings and Important notes at the end of this document. Page 6 of 36 B43851 Standard series 105 °C Overview of available types B43851 Other voltage and capacitance ratings are available upon request. VR (V DC) 160 200 250 350 400 450 Case dimensions d × l (mm) CR (µF) 0.47 6.3 × 11 6.3 × 11 0.68 6.3 × 11 6.3 × 11 1.0 6.3 × 11 6.3 × 11 6.3 × 11 6.3 × 11 2.2 6.3 × 11 6.3 × 11 6.3 × 11 6.3 × 11 8 × 11.5 3.3 6.3 × 11 6.3 × 11 6.3 × 11 8 4.7 6.3 × 11 6.3 × 11 8 × 11.5 8 × 11.5 10 × 12.5 10 8 × 11.5 8 × 11.5 × 11.5 8 × 11.5 10 × 12.5 × 11.5 10 × 12.5 10 × 12.5 × 16 10 × 20 10 × 20 10 8 × 11.5 8 22 10 10 × 12.5 × 16 10 × 16 10 × 20 12.5 × 20 12.5 × 25 33 10 10 × 16 × 20 10 × 20 12.5 × 20 12.5 × 25 16 × 20 16 × 25 47 10 × 20 12.5 × 20 12.5 × 20 12.5 × 25 16 × 25 16 × 25 16 × 31.5 12.5 × 25 68 12.5 × 20 12.5 × 25 16 × 25 16 × 31.5 18 × 31.5 18 × 35 100 12.5 × 25 16 × 25 16 × 25 16 × 31.5 18 × 35 18 × 40 20 × 40 220 16 18 × 31.5 × 31.5 18 × 31.5 18 × 40 330 18 × 35 20 × 35 22 × 40 470 20 × 40 22 × 40 680 25 × 40 Please read Cautions and warnings and Important notes at the end of this document. Page 7 of 36 B41851 Standard series 105 °C Technical data and ordering codes B41851 CR 120 Hz 20 °C µF Case dimensions d×l mm VR = 6.3 V DC 330 6.3 × 11 470 8 × 11.5 680 8 × 11.5 1000 10 × 12.5 1500 10 × 16 2200 10 × 20 3300 10 × 20 4700 12.5 × 25 VR = 10 V DC 100 5 × 11 220 6.3 × 11 330 8 × 11.5 470 8 × 11.5 680 10 × 12.5 1000 10 × 12.5 1500 10 × 20 2200 10 × 20 3300 12.5 × 25 4700 16 × 20 6800 16 × 25 10000 18 × 31.5 ESRmax 120 Hz 20 °C Ω IAC,R 120 Hz 105 °C mA IAC,max 120 Hz 85 °C mA Ordering code (composition see below) 1.4 1.0 0.68 0.46 0.31 0.23 0.16 0.12 195 265 295 455 525 710 840 1120 275 370 413 635 735 995 1175 1570 B41851A2337M*** B41851B2477M*** B41851F2687M*** B41851A2108M*** B41851F2158M*** B41851A2228M*** B41851A2338M*** B41851A2478M*** 4.0 1.8 1.2 0.85 0.59 0.40 0.27 0.20 0.14 0.11 0.08 0.07 105 175 220 280 330 460 510 760 1085 1190 1575 1820 150 245 310 390 460 645 715 1065 1520 1665 2205 2250 B41851A3107M*** B41851A3227M*** B41851B3337M*** B41851A3477M*** B41851A3687M*** B41851A3108M*** B41851A3158M*** B41851A3228M*** B41851A3338M*** B41851A3478M*** B41851F3688M*** B41851F3109M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm) 002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 5 × 11 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 8 of 36 B41851 Standard series 105 °C Technical data and ordering codes B41851 CR 120 Hz 20 °C µF Case dimensions d×l mm VR = 16 V DC 100 5 × 11 220 6.3 × 11 330 8 × 11.5 470 8 × 11.5 680 10 × 12.5 1000 10 × 16 1500 10 × 20 2200 12.5 × 20 3300 12.5 × 25 3300 16 × 25 4700 16 × 25 6800 16 × 31.5 10000 18 × 35 VR = 25 V DC 47 5 × 11 68 5 × 11 100 6.3 × 11 220 8 × 11.5 330 8 × 11.5 330 10 × 12.5 470 10 × 12.5 680 10 × 16 1000 10 × 20 1500 12.5 × 20 2200 12.5 × 25 3300 16 × 25 4700 16 × 31.5 6800 18 × 35 10000 20 × 40 ESRmax 120 Hz 20 °C Ω IAC,R 120 Hz 105 °C mA IAC,max 120 Hz 85 °C mA Ordering code (composition see below) 3.3 1.5 1.0 0.71 0.49 0.33 0.22 0.17 0.12 0.12 0.09 0.07 0.06 115 190 265 315 390 560 650 920 1170 1260 1500 1600 1950 160 265 370 440 545 785 910 1290 1640 1765 2100 2240 2730 B41851A4107M*** B41851F4227M*** B41851B4337M*** B41851K4477M*** B41851F4687M*** B41851A4108M*** B41851F4158M*** B41851F4228M*** B41851F4338M*** B41851A4338M*** B41851A4478M*** B41851F4688M*** B41851F4109M*** 5.6 3.9 2.7 1.2 0.80 0.80 0.56 0.39 0.27 0.18 0.14 0.10 0.08 0.06 0.06 83 90 140 240 310 320 380 440 680 770 1090 1400 1700 1850 2050 116 126 195 335 435 450 530 615 950 1080 1525 1960 2380 2590 2870 B41851A5476M*** B41851F5686M*** B41851A5107M*** B41851B5227M*** B41851F5337M*** B41851A5337M*** B41851F5477M*** B41851F5687M*** B41851A5108M*** B41851F5158M*** B41851F5228M*** B41851A5338M*** B41851A5478M*** B41851F5688M*** B41851F5109M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm) 002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 5 × 11 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 9 of 36 B41851 Standard series 105 °C Technical data and ordering codes B41851 CR 120 Hz 20 °C µF Case dimensions d×l mm VR = 35 V DC 33 5 × 11 47 5 × 11 68 6.3 × 11 100 6.3 × 11 220 8 × 11.5 330 10 × 12.5 470 10 × 16 680 10 × 20 1000 12.5 × 20 1500 16 × 20 2200 16 × 25 3300 16 × 31.5 4700 18 × 35 6800 18 × 40 VR = 50 V DC 1 5 × 11 2.2 5 × 11 3.3 5 × 11 4.7 5 × 11 10 5 × 11 22 5 × 11 33 6.3 × 11 47 6.3 × 11 68 6.3 × 11 100 8 × 11.5 220 10 × 12.5 ESRmax 120 Hz 20 °C Ω IAC,R 120 Hz 105 °C mA IAC,max 120 Hz 85 °C mA Ordering code (composition see below) 7.0 4.9 3.4 2.3 1.1 0.70 0.49 0.34 0.23 0.15 0.12 0.09 0.07 0.06 75 93 110 150 270 350 460 590 810 980 1260 1500 1780 2000 105 130 155 210 380 490 645 825 1135 1370 1765 2100 2490 2800 B41851A7336M*** B41851A7476M*** B41851A7686M*** B41851F7107M*** B41851F7227M*** B41851A7337M*** B41851A7477M*** B41851A7687M*** B41851F7108M*** B41851F7158M*** B41851F7228M*** B41851F7338M*** B41851K7478M*** B41851K7688M*** 199 90 60 42 20 9.0 6.0 4.2 2.9 2.0 0.90 13 20 25 30 46 67 90 115 150 190 300 18 28 35 42 65 94 126 160 210 265 420 B41851A6105M*** B41851A6225M*** B41851A6335M*** B41851A6475M*** B41851B6106M*** B41851A6226M*** B41851A6336M*** B41851A6476M*** B41851F6686M*** B41851A6107M*** B41851A6227M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm) 002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 5 × 11 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 10 of 36 B41851 Standard series 105 °C Technical data and ordering codes B41851 CR 120 Hz 20 °C µF Case dimensions d×l mm VR = 50 V DC 330 10 × 16 470 10 × 20 680 12.5 × 20 1000 12.5 × 25 1500 16 × 25 2200 16 × 31.5 2200 18 × 35 3300 18 × 35 4700 20 × 40 VR = 63 V DC 10 5 × 11 22 5 × 11 33 6.3 × 11 47 6.3 × 11 68 8 × 11.5 100 8 × 11.5 220 10 × 16 330 10 × 20 470 12.5 × 20 680 16 × 20 1000 16 × 25 1500 18 × 31.5 2200 18 × 35 3300 20 × 40 4700 25 × 40 ESRmax 120 Hz 20 °C Ω IAC,R 120 Hz 105 °C mA IAC,max 120 Hz 85 °C mA Ordering code (composition see below) 0.60 0.42 0.29 0.20 0.13 0.11 0.11 0.08 0.06 410 540 700 950 1260 1410 1540 1770 2100 575 755 980 1330 1765 1975 2155 2480 2940 B41851A6337M*** B41851A6477M*** B41851F6687M*** B41851F6108M*** B41851F6158M*** B41851F6228M*** B41851A6228M*** B41851K6338M*** B41851K6478M*** 20 9.0 6.0 4.2 2.9 2.0 0.90 0.60 0.42 0.29 0.20 0.13 0.11 0.08 0.06 46 70 100 120 155 200 335 510 640 770 930 1260 1650 1950 2250 65 100 140 170 220 280 470 715 895 1080 1300 1765 2310 2730 3150 B41851A8106M*** B41851F8226M*** B41851A8336M*** B41851F8476M*** B41851F8686M*** B41851F8107M*** B41851A8227M*** B41851A8337M*** B41851F8477M*** B41851F8687M*** B41851F8108M*** B41851F8158M*** B41851K8228M*** B41851A8338M*** B41851F8478M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm) 002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 5 × 11 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 11 of 36 B41851 Standard series 105 °C Technical data and ordering codes B41851 CR 120 Hz 20 °C µF Case dimensions d×l mm VR = 100 V DC 0.1 5 × 11 0.22 5 × 11 0.33 5 × 11 0.47 5 × 11 0.68 5 × 11 1 5 × 11 2.2 5 × 11 3.3 5 × 11 4.7 5 × 11 10 6.3 × 11 22 8 × 11.5 33 8 × 11.5 33 10 × 12.5 47 10 × 12.5 68 10 × 16 100 10 × 20 220 12.5 × 25 330 16 × 25 470 16 × 31.5 680 18 × 40 1000 18 × 40 ESRmax 120 Hz 20 °C Ω 1658 754 502 353 244 166 75 50 35 17 7.5 5.0 5.0 3.5 2.4 1.7 0.75 0.50 0.35 0.24 0.17 IAC,R 120 Hz 105 °C mA IAC,max 120 Hz 85 °C mA Ordering code (composition see below) 1.5 3.4 5.0 7.1 9.1 15 21 29 32 53 98 125 135 160 195 245 435 560 700 770 950 2.1 4.8 7.0 10 13 21 30 41 45 74 137 175 190 225 275 345 610 785 980 1080 1330 B41851A9104M*** B41851A9224M*** B41851A9334M*** B41851A9474M*** B41851A9684M*** B41851A9105M*** B41851A9225M*** B41851A9335M*** B41851A9475M*** B41851A9106M*** B41851B9226M*** B41851F9336M*** B41851A9336M*** B41851B9476M*** B41851A9686M*** B41851A9107M*** B41851A9227M*** B41851A9337M*** B41851A9477M*** B41851F9687M*** B41851F9108M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm) 002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 5 × 11 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 12 of 36 B43851 Standard series 105 °C Technical data and ordering codes B43851 CR 120 Hz 20 °C µF Case dimensions d×l mm VR = 160 V DC 1 6.3 × 11 2.2 6.3 × 11 3.3 6.3 × 11 4.7 6.3 × 11 10 8 × 11.5 22 10 × 12.5 22 10 × 16 33 10 × 16 33 10 × 20 47 10 × 20 47 12.5 × 20 68 12.5 × 20 100 12.5 × 25 100 16 × 25 220 16 × 31.5 220 18 × 31.5 330 18 × 35 470 20 × 40 680 25 × 40 ESRmax 120 Hz 20 °C Ω IAC,R 120 Hz 105 °C mA IAC,max 120 Hz 85 °C mA Ordering code (composition see below) 186 85 56 40 18 13 8.4 7.5 5.6 4.9 4.5 3.0 2.3 1.8 0.95 0.84 0.70 0.42 0.34 16 23 28 35 56 91 108 125 143 150 188 250 300 332 532 560 695 910 1000 27 39 48 60 95 155 184 213 243 255 320 425 510 564 904 952 1182 1547 1700 B43851A1105M*** B43851A1225M*** B43851A1335M*** B43851F1475M*** B43851F1106M*** B43851F1226M*** B43851A1226M*** B43851F1336M*** B43851A1336M*** B43851K1476M*** B43851F1476M*** B43851K1686M*** B43851F1107M*** B43851A1107M*** B43851F1227M*** B43851A1227M*** B43851F1337M*** B43851F1477M*** B43851G1687M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm) 002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 6.3 × 11 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 13 of 36 B43851 Standard series 105 °C Technical data and ordering codes B43851 CR 120 Hz 20 °C µF Case dimensions d×l mm VR = 200 V DC 1 6.3 × 11 2.2 6.3 × 11 3.3 6.3 × 11 4.7 6.3 × 11 10 8 × 11.5 22 10 × 16 33 10 × 20 47 12.5 × 20 68 12.5 × 25 100 16 × 25 220 18 × 31.5 330 20 × 35 470 22 × 40 VR = 250 V DC 0.47 6.3 × 11 0.68 6.3 × 11 1 6.3 × 11 2.2 6.3 × 11 3.3 6.3 × 11 4.7 8 × 11.5 10 10 × 12.5 22 10 × 20 33 12.5 × 20 47 12.5 × 25 68 16 × 25 100 16 × 31.5 220 18 × 40 330 22 × 40 ESRmax 120 Hz 20 °C Ω IAC,R 120 Hz 105 °C mA IAC,max 120 Hz 85 °C mA Ordering code (composition see below) 186 85 56 40 21 8.4 5.6 4.5 3.3 1.8 0.95 0.65 0.46 16 23 28 35 56 108 144 190 245 332 560 650 760 27 39 48 60 95 184 245 323 417 564 952 1105 1292 B43851A2105M*** B43851A2225M*** B43851A2335M*** B43851G2475M*** B43851G2106M*** B43851K2226M*** B43851B2336M*** B43851R2476M*** B43851K2686M*** B43851A2107M*** B43851B2227M*** B43851R2337M*** B43851R2477M*** 395 273 186 85 65 40 23 8.4 5.6 4.3 2.7 1.8 0.84 0.56 11 13 16 23 35 38 66 120 161 203 266 364 476 658 19 22 27 39 60 65 112 204 274 345 452 619 809 1119 B43851F2474M*** B43851F2684M*** B43851F2105M*** B43851F2225M*** B43851K2335M*** B43851P2475M*** B43851K2106M*** B43851F2226M*** B43851K2336M*** B43851G2476M*** B43851F2686M*** B43851K2107M*** B43851F2227M*** B43851F2337M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm) 002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 6.3 × 11 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 14 of 36 B43851 Standard series 105 °C Technical data and ordering codes B43851 CR 120 Hz 20 °C µF Case dimensions d×l mm VR = 350 V DC 0.47 6.3 × 11 0.68 6.3 × 11 1 6.3 × 11 2.2 6.3 × 11 2.2 8 × 11.5 3.3 8 × 11.5 4.7 8 × 11.5 10 10 × 16 22 12.5 × 20 33 12.5 × 25 47 16 × 25 68 16 × 31.5 100 18 × 35 VR = 400 V DC 2.2 8 × 11.5 3.3 8 × 11.5 4.7 10 × 12.5 10 10 × 20 22 12.5 × 25 33 16 × 20 47 16 × 25 68 18 × 31.5 100 18 × 40 ESRmax 120 Hz 20 °C Ω IAC,R 120 Hz 105 °C mA IAC,max 120 Hz 85 °C mA Ordering code (composition see below) 395 273 186 97 85 65 45 21 9.0 5.6 4.0 3.1 2.3 10 12 15 23 26 30 38 70 140 168 210 290 364 17 20 26 39 44 51 65 119 238 286 357 493 619 B43851A4474M*** B43851A4684M*** B43851A4105M*** B43851F4225M*** B43851B4225M*** B43851F4335M*** B43851F4475M*** B43851F4106M*** B43851F4226M*** B43851F4336M*** B43851F4476M*** B43851F4686M*** B43851F4107M*** 97 65 46 18 8.4 5.6 4.0 3.3 1.9 26 36 56 80 140 168 196 294 310 44 61 95 136 238 286 333 500 527 B43851H9225M*** B43851F9335M*** B43851F9475M*** B43851A9106M*** B43851F9226M*** B43851F9336M*** B43851F9476M*** B43851A9686M*** B43851K9107M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm) 002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 6.3 × 11 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 15 of 36 B43851 Standard series 105 °C Technical data and ordering codes B43851 CR 120 Hz 20 °C µF Case dimensions d×l mm VR = 450 V DC 2.2 8 × 11.5 3.3 10 × 12.5 4.7 10 × 12.5 10 10 × 20 22 12.5 × 25 33 16 × 25 47 16 × 31.5 68 18 × 35 100 20 × 40 ESRmax 120 Hz 20 °C Ω IAC,R 120 Hz 105 °C mA IAC,max 120 Hz 85 °C mA 97 65 45 26 14 7.6 4.8 2.7 1.8 20 28 32 56 100 125 155 193 207 34 48 54 95 170 213 264 328 352 Ordering code (composition see below) B43851F5225M*** B43851F5335M*** B43851K5475M*** B43851F5106M*** B43851F5226M*** B43851F5336M*** B43851F5476M*** B43851A5686M*** B43851A5107M*** Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d × l = 10 × 20 mm to 18 × 40 mm) 002 = for cut leads, bulk (from d × l = 10 × 12.5 mm to 22 × 40 mm) 003 = for crimped leads, blister (from d × l = 16 × 20 mm to 20 × 40 mm) 004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 6.3 × 11 mm to 12.5 × 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm) 012 = for bent 90° leads, blister (for ∅ 16 and 18 mm) Please read Cautions and warnings and Important notes at the end of this document. Page 16 of 36 B41851, B43851 Standard series 105 °C Useful life depending on ambient temperature TA under ripple current operating conditions1) VR = 6.3 ... 100 V DC VR = 160 ... 450 V DC 1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life graphs. Please read Cautions and warnings and Important notes at the end of this document. Page 17 of 36 B41851, B43851 Standard series 105 °C Frequency factor of permissible ripple current IAC versus frequency f VR ≤ 100 V DC Please read Cautions and warnings and Important notes at the end of this document. Frequency factor of permissible ripple current IAC versus frequency f VR ≥ 160 V DC Page 18 of 36 B41851, B43851 Standard series 105 °C Taping, packing and lead configurations Taping Single-ended capacitors are available taped in Ammo pack from diameter 5 to 18 mm as follows: Lead spacing F = 2.5 mm (∅ d = 5 … 6.3 mm) Lead spacing F = 3.5 mm (∅ d = 8 mm) Lead spacing F = 5.0 mm (from d × l = 10 × 12.5 mm to 12.5 × 30 mm) Lead spacing F = 7.5 mm (∅ d = 16 ... 18 mm). Lead spacing 2.5 mm (∅ d = 5 ... 6.3 mm) Last 3 digits of ordering code: 007 Dimensions in mm ∅d 5 F H W W0 W1 W2 H0 P P0 P1 I1 t ∆h D0 2.5 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 5.1 1.0 0.7 1.0 4.0 6.3 Toler- +0.8 ±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. ±0.2 max. ±0.2 ance 0.2 Please read Cautions and warnings and Important notes at the end of this document. Page 19 of 36 B41851, B43851 Standard series 105 °C Lead spacing 3.5 mm (∅ d = 8 mm) Last 3 digits of ordering code: 006 Dimensions in mm ∅d 8 Tolerance F H W W0 W1 W2 P P0 P1 I1 t ∆h 3.5 18.5 18.0 12.5 9.0 1.5 12.7 12.7 4.6 1.0 0.7 1.0 +0.8 ±1.0 0.2 ±0.5 min. ±0.5 max. ±1.0 ±0.2 ±0.5 max. ±0.2 Please read Cautions and warnings and Important notes at the end of this document. Page 20 of 36 D0 4.0 max. ±0.2 B41851, B43851 Standard series 105 °C Lead spacing 5.0 mm (∅ d = 5 ... 8 mm) Last 3 digits of ordering code: 008 Lead spacing 5.0 mm (from d × l = 10 × 12.5 mm to 12.5 × 30 mm) Last 3 digits of ordering code: 008 Dimensions in mm ∅d 5 6.3 F H W W0 W1 W2 H0 P P0 P1 I1 t ∆h D0 5.0 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 3.85 1.0 0.7 1.0 4.0 16.0 12.7 12.7 3.85 18.0 12.5 9.0 1.5 12.7 12.7 3.85 1.0 0.7 1.0 4.0 15.0 15.0 5.0 ±1.0 ±0.2 ±0.5 8 10 20.0 5.0 19.0 12.5 19.0 Toler- +0.8 ±0.75 ±0.5 min. ±0.5 max. ±0.5 ance 0.2 Please read Cautions and warnings and Important notes at the end of this document. Page 21 of 36 max. ±0.2 max. ±0.2 B41851, B43851 Standard series 105 °C Lead spacing 7.5 mm (∅ d = 16 ...18 mm) Last 3 digits of ordering code: 009 Dimensions in mm ∅d 16 F H W 7.5 18.5 18.0 18 *) Toler0.5 ±0.8 ±0.5 ance +0.75 W0 W1 W2 P P0 P1 I1 t ∆P ∆h D0 12.5 9.0 1.5 30.0 15.0 3.75 1.0 0.7 0 0 4.0 min. ±0.5 max. ±1.0 ±0.2 ±0.5 max. ±0.2 ±1.0 ±1.0 ±0.2 *) Available only for case dimensions 18 × 20, 18 × 25 and 18 × 31.5 mm Please read Cautions and warnings and Important notes at the end of this document. Page 22 of 36 B41851, B43851 Standard series 105 °C Packing units and box dimensions Ammo pack Please read Cautions and warnings and Important notes at the end of this document. Case size d×l mm Dimensions (mm) Amax Bmax Cmax 5 × 11 345 55 240 2000 6.3 × 11 345 55 290 2000 8 × 11.5 345 55 240 1000 10 × 12.5 345 55 280 750 10 × 16 345 60 200 500 10 × 20 345 60 200 500 12.5 × 20 345 65 280 500 12.5 × 25 345 65 280 500 16 × 20 315 65 275 300 16 × 25 315 65 275 300 16 × 31.5 315 65 275 300 18 × 20 315 65 275 250 18 × 25 315 65 275 250 18 × 31.5 315 65 275 250 Page 23 of 36 Packing units pcs. B41851, B43851 Standard series 105 °C Kinked or cut leads Single-ended capacitors are available with kinked or cut leads. Other lead configurations also available upon request. Kinked leads Last 3 digits of ordering code: 001 With stand-off rubber seal Case size d × l (mm) With flat rubber seal Please read Cautions and warnings and Important notes at the end of this document. Page 24 of 36 Dimensions (mm) a ±0.5 10 × 20 5.0 12.5 × 20 5.0 12.5 × 25 5.0 16 × 20 7.5 16 × 25 7.5 16 × 31.5 7.5 18 × 20 7.5 18 × 25 7.5 18 × 31.5 7.5 18 × 35 7.5 18 × 40 7.5 B41851, B43851 Standard series 105 °C Cut leads Last 3 digits of ordering code: 002 With stand-off rubber seal Case size d × l (mm) With flat rubber seal Please read Cautions and warnings and Important notes at the end of this document. Page 25 of 36 Dimensions (mm) a ±0.5 10 × 12.5 5.0 10 × 16 5.0 10 × 20 5.0 12.5 × 20 5.0 12.5 × 25 5.0 16 × 20 7.5 16 × 25 7.5 16 × 31.5 7.5 18 × 20 7.5 18 × 25 7.5 18 × 31.5 7.5 18 × 35 7.5 18 × 40 7.5 20 × 20 10.0 20 × 25 10.0 20 × 30 10.0 20 × 35 10.0 20 × 40 10.0 22 × 30 10.0 22 × 35 10.0 22 × 40 10.0 B41851, B43851 Standard series 105 °C PAPR leads (Protection Against Polarity Reversal) These lead configurations ensure correct placement of the capacitor on the PCB with regard to polarity. PAPR leads are available for diameters from 10 mm up to 20 mm. There are three configurations available: Crimped leads, J leads, bent 90° leads Crimped leads Last 3 digits of ordering code: 003 With stand-off rubber seal With flat rubber seal Suggestion for PCB hole diameter Case size d × l (mm) Dimensions (mm) B ±0.2 C ±0.5 D ±0.1 E ±0.1 16 × 20 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05 16 × 25 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05 16 × 31.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.05 18 × 20 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1 18 × 25 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1 18 × 31.5 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1 18 × 35 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1 18 × 40 1.5 3.0 1.3 0.3 7.5 0.8 ±0.1 20 × 20 1.5 3.0 1.6 0.3 10.0 1.0 ±0.1 20 × 25 1.5 3.0 1.6 0.3 10.0 1.0 ±0.1 20 × 30 1.5 3.0 1.6 0.3 10.0 1.0 ±0.1 20 × 35 1.5 3.0 1.6 0.3 10.0 1.0 ±0.1 20 × 40 1.5 3.0 1.6 0.3 10.0 1.0 ±0.1 Please read Cautions and warnings and Important notes at the end of this document. Page 26 of 36 a ±0.5 ∅b B41851, B43851 Standard series 105 °C J leads Last 3 digits of ordering code: 004 Suggestion for PCB hole diameter Case size d × l (mm) Dimensions (mm) C ±0.5 E ±0.5 J ±0.2 10 × 12.5 3.2 0.7 1.2 5.0 0.6 ±0.05 10 × 16 3.2 0.7 1.2 5.0 0.6 ±0.05 10 × 20 3.2 0.7 1.2 5.0 0.6 ±0.05 12.5 × 20 3.2 0.7 1.2 5.0 0.6 ±0.05 12.5 × 25 3.2 0.7 1.2 5.0 0.6 ±0.05 16 × 20 3.5 0.7 1.6 7.5 0.8 ±0.05 16 × 25 3.5 0.7 1.6 7.5 0.8 ±0.05 16 × 31.5 3.5 0.7 1.6 7.5 0.8 ±0.05 18 × 20 3.5 0.7 1.6 7.5 0.8 ±0.1 18 × 25 3.5 0.7 1.6 7.5 0.8 ±0.1 18 × 31.5 3.5 0.7 1.6 7.5 0.8 ±0.1 18 × 35 3.5 0.7 1.6 7.5 0.8 ±0.1 Please read Cautions and warnings and Important notes at the end of this document. Page 27 of 36 a ±0.5 ∅b B41851, B43851 Standard series 105 °C Bent 90° leads for horizontal mounting pinning Last 3 digits of ordering code: 012 Case size d × l (mm) Dimensions (mm) C ±0.5 E ±0.5 F ±0.5 a ±0.5 ∅b 16 × 20 4.0 4.0 12.0 7.5 0.8 ±0.05 16 × 25 4.0 4.0 12.0 7.5 0.8 ±0.05 16 × 31.5 4.0 4.0 12.0 7.5 0.8 ±0.05 18 × 20 4.0 4.0 13.0 7.5 0.8 ±0.1 18 × 25 4.0 4.0 13.0 7.5 0.8 ±0.1 18 × 31.5 4.0 4.0 13.0 7.5 0.8 ±0.1 18 × 35 4.0 4.0 13.0 7.5 0.8 ±0.1 18 × 40 4.0 4.0 13.0 7.5 0.8 ±0.1 Bent leads for diameter 12.5 mm available upon request. Please read Cautions and warnings and Important notes at the end of this document. Page 28 of 36 B41851, B43851 Standard series 105 °C Overview of packing units and code numbers for case sizes 5 × 11 ... 16 × 31.5 PAPR Case size d×l Taped, Ammo pack mm Standard, bulk pcs. pcs. Kinked leads, bulk pcs. Cut leads, bulk pcs. Crimped J leads, leads, blister blister pcs. pcs. 2000 5 × 11 2000 6.3 × 11 2500 2000 8 × 11.5 1000 1000 10 × 12.5 1000 750 10 × 16 1000 500 1000 10 × 20 500 500 500 500 12.5 × 20 350 500 350 350 12.5 × 25 250 500 500 500 12.5 × 30 200 12.5 × 35 175 12.5 × 40 175 16 × 20 250 300 200 200 200 200 120 16 × 25 250 300 200 200 200 200 120 16 × 31.5 200 300 250 250 344 344 120 The last three digits of the complete ordering code state the lead configuration 000 Code 006 007 008 009 001 002 003 004 012 F (mm) d (mm) 3.5 2.5 5 7.5 8 5...6.3 5...12.5 16...18 1) Available upon request Please read Cautions and warnings and Important notes at the end of this document. Page 29 of 36 1000 Bent 90° leads, blister pcs. 675 675 500 300 1) 225 1) B41851, B43851 Standard series 105 °C Overview of packing units and code numbers for case sizes 18 × 20 ... 25 × 40 PAPR Case size d×l Taped, Ammo pack mm Standard, bulk pcs. pcs. Kinked leads, bulk pcs. Cut leads, bulk pcs. Crimped J leads, leads, blister blister pcs. pcs. Bent 90° leads, blister pcs. 18 × 20 175 18 × 25 150 250 175 175 200 200 120 250 150 150 200 200 18 × 31.5 120 100 250 100 100 150 150 120 18 × 35 100 100 100 150 150 150 18 × 40 125 100 100 120 72 20 × 20 125 125 200 20 × 25 125 125 200 20 × 30 100 100 120 20 × 35 100 100 120 20 × 40 100 100 120 22 × 30 80 100 22 × 35 80 22 × 40 80 25 × 40 40 The last three digits of the complete ordering code state the lead configuration 000 Code 007 008 009 Please read Cautions and warnings and Important notes at the end of this document. F (mm) d (mm) 2.5 5 7.5 100 100 001 002 4...6.3 6.3...12.5 16...18 Page 30 of 36 003 004 012 B41851, B43851 Standard series 105 °C Cautions and warnings Personal safety The electrolytes used by EPCOS have not only been optimized with a view to the intended application, but also with regard to health and environmental compatibility. They do not contain any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide (DMAC). Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They contain flame-retarding substances which will quickly extinguish any flame that may have been ignited. As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce operating electrolytes. However, in exceptional cases, such materials must be used in order to achieve specific physical and electrical properties because no safe substitute materials are currently known. However, the amount of dangerous materials used in our products has been limited to an absolute minimum. Nevertheless, the following rules should be observed when handling Al electrolytic capacitors: Any escaping electrolyte should not come into contact with eyes or skin. If electrolyte does come into contact with the skin, wash the affected parts immediately with running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If symptoms persist, seek medical treatment. Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be well ventilated. Clothing that has been contaminated by electrolyte must be changed and rinsed in water. Please read Cautions and warnings and Important notes at the end of this document. Page 31 of 36 B41851, B43851 Standard series 105 °C Product safety The table below summarize the safety instructions that must be observed without fail. A detailed description can be found in the relevant sections of chapter "General technical information". Topic Safety information Polarity Make sure that polar capacitors are connected with the right polarity. Reverse voltage Voltages polarity classes should be prevented by connecting a diode. Do not exceed the upper category temperatur. Upper category temperature Maintenance Mounting position of screw terminal capacitors Mounting of single-ended capacitors Robustness of terminals Soldering Make periodic inspections of the capacitors. Before the inspection, make sure that the power supply is turned off and carefully discharge the electricity of the capacitors. Do not apply any mechanical stress to the capacitor terminals. Do not mount the capacitor with the terminals (safety vent) upside down. Reference Chapter "General technical information" 1 "Basic construction of aluminum electrolytic capacitors" 3.1.6 "Reverse voltage" 7.2 "Maximum permissible operating temperature" 10 "Maintenance" 11.1 "Mounting positions of capacitors with screw terminals" The internal structure of single-ended capacitors 11.4 might be damaged if excessive force is applied to "Mounting the lead wires. considerations for Avoid any compressive, tensile or flexural stress. single-ended capacitors" Do not move the capacitor after soldering to PC board. Do not pick up the PC board by the soldered capacitor. Do not insert the capacitor on the PC board with a hole space different to the lead space specified. The following maximum tightening torques must 11.3 not be exceeded when connecting screw "Mounting torques" terminals: M5: 2 Nm M6: 2.5 Nm Do not exceed the specified time or temperature 11.5 limits during soldering. "Soldering" Please read Cautions and warnings and Important notes at the end of this document. Page 32 of 36 B41851, B43851 Standard series 105 °C Topic Soldering, cleaning agents Passive flammability Active flammability Safety information Reference Chapter "General technical information" Do not allow halogenated hydrocarbons to come 11.6 into contact with aluminum electrolytic capacitors. "Cleaning agents" Avoid external energy, such as fire or electricity. 8.1 "Passive flammability" Avoid overload of the capacitors. 8.2 "Active flammability" Breakdown strength Do not damage the insulating sleeve, especially of insulating when ring clips are used for mounting. sleeves Please read Cautions and warnings and Important notes at the end of this document. Page 33 of 36 Reference Chapter "Capacitors with screw terminals" "Screw terminals accessories" B41851, B43851 Standard series 105 °C Symbols and terms Symbol English German C CR CS CS,T Cf d dmax ESL ESR ESRf Capacitance Rated capacitance Series capacitance Series capacitance at temperature T Capacitance at frequency f Case diameter, nominal dimension Maximum case diameter Self-inductance Equivalent series resistance Equivalent series resistance at frequency f Equivalent series resistance at temperature T Frequency Current Alternating current (ripple current) Root-mean-square value of alternating current Ripple current at frequency f Maximum permissible ripple current Rated ripple current Rated ripple current for base cooling Leakage current Operating leakage current Case length, nominal dimension Maximum case length (without terminals and mounting stud) Resistance Insulation resistance Balancing resistance Temperature Temperature difference Ambient temperature Case temperature Capacitor base temperature Time Period Service life (operating hours) Kapazität Nennkapazität Serienkapazität Serienkapazität bei Temperatur T Kapazität bei Frequenz f Gehäusedurchmesser, Nennmaß Maximaler Gehäusedurchmesser Eigeninduktivität Ersatzserienwiderstand Ersatzserienwiderstand bei Frequenz f ESRT f I IAC IAC,rms IAC,f IAC,max IAC,R IAC,R (B) Ileak Ileak,op l lmax R Rins Rsymm T ∆T TA TC TB t ∆t tb Please read Cautions and warnings and Important notes at the end of this document. Ersatzserienwiderstand bei Temperatur T Frequenz Strom Wechselstrom Wechselstrom, Effektivwert Wechselstrom bei Frequenz f Maximal zulässiger Wechselstrom Nennwechselstrom Nennwechselstromstrom für Bodenkühlung Ableitstrom Ableitstrom bei Betrieb Gehäuselänge, Nennmaß Maximale Gehäuselänge (ohne Anschlüsse und Gewindebolzen) Widerstand Isolationswiderstand Symmetrierwiderstand Temperatur Temperaturdifferenz Umgebungstemperatur Gehäusetemperatur Temperatur des Becherbodens Zeit Zeitraum Brauchbarkeitsdauer (Betriebszeit) Page 34 of 36 B41851, B43851 Standard series 105 °C Symbol V VF Vop VR VS XC XL Z ZT tan δ λ ε0 εr ω English Voltage Forming voltage Operating voltage Rated voltage, DC voltage Surge voltage Capacitive reactance Inductive reactance Impedance Impedance at temperature T Dissipation factor Failure rate Absolute permittivity Relative permittivity Angular velocity; 2 π f German Spannung Formierspannung Betriebsspannung Nennspannung, Gleichspannung Spitzenspannung Kapazitiver Blindwiderstand Induktiver Blindwiderstand Scheinwiderstand Scheinwiderstand bei Temperatur T Verlustfaktor Ausfallrate Elektrische Feldkonstante Dielektrizitätszahl Kreisfrequenz; 2 π f Notes All dimensions are given in mm. Please read Cautions and warnings and Important notes at the end of this document. Page 35 of 36 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 36 of 36