MINI BHP-400+ High pass filter 50î© 395 to 3200 mhz Datasheet

Coaxial
High Pass Filter
50Ω
BHP-400+
395 to 3200 MHz
Features
Maximum Ratings
Operating Temperature
-55°C to 100°C
Storage Temperature
-55°C to 100°C
RF Power Input
0.5W max.
• rugged shielded case
• other standard and custom BHP models available
with wide selection of fco
CASE STYLE: FF55
Model
Price
Qty.
BHP-400+
$36.95 ea. (1-9)
Connectors
BNC
+ RoHS compliant in accordance
with EU Directive (2002/95/EC)
Applications
• lab use
• transmitters/receivers
• radio communications
The +Suffix has been added in order to identify RoHS
Compliance. See our web site for RoHS Compliance
methodologies and qualifications.
High Pass Filter Electrical Specifications
STOPBAND
(MHz)
fco (MHz)
Nom.
PASSBAND
(MHz)
(loss > 40 dB)
(loss > 20 dB)
(loss 3 dB)
(loss <1 dB)
Stopband
Typ.
Passband
Typ.
DC-210
210-290
360
395-3200
17
1.7
typical frequency response
Outline Drawing
electrical schematic
RF IN
Attenuation, dB
40
Outline Dimensions ( inch
mm )
3
1
DC
Typical Performance Data
x
σ
73.49
92.04
76.80
64.86
55.25
41.38
41.06
40.72
40.39
40.06
39.73
39.40
39.07
38.09
29.94
21.83
21.50
21.18
3.31
0.95
0.53
0.31
0.32
0.26
0.22
0.20
0.19
0.27
0.30
0.34
3.76
7.79
1.38
0.57
0.43
0.57
0.57
0.57
0.58
0.58
0.58
0.57
0.59
0.59
0.66
0.75
0.75
0.76
0.67
0.19
0.01
0.02
0.03
0.02
0.01
0.01
0.01
0.02
0.03
0.01
Return Loss
(dB)
Frequency
(MHz)
Group Delay
(nsec)
0.05
0.05
0.11
0.09
0.10
0.17
0.17
0.18
0.17
0.18
0.18
0.18
0.18
0.18
0.22
0.33
0.33
0.34
4.07
11.83
21.31
23.56
17.14
19.37
24.00
28.18
29.90
18.44
17.29
21.10
10.00
100.00
150.00
175.00
200.00
240.00
241.00
242.00
243.00
244.00
245.00
246.00
247.00
250.00
275.00
300.00
301.00
302.00
360.00
380.00
400.00
500.00
600.00
700.00
800.00
900.00
1000.00
2000.00
3000.00
4000.00
17.71
57.88
0.94
0.34
1.22
1.56
1.56
1.57
1.57
1.58
1.61
1.60
1.60
1.61
1.96
2.53
2.56
2.59
6.64
6.00
4.41
2.06
1.35
1.02
0.83
0.71
0.61
0.35
0.31
0.30
RETURN LOSS
at RF level of 0 dBm
1
GROUP DELAY (nsec)
10
25
20
15
10
5
0
1000
2000
FREQUENCY (MHz)
3000
4000
GROUP DELAY
10.0
1.0
0.1
0
0
at RF level of 0 dBm
100.0
30
RETURN LOSS (dB)
INSERTION LOSS (dB)
35
.75 1 1.1
.5
Frequency/fco
Insertion Loss
(dB)
_
10.00
100.00
150.00
175.00
200.00
240.00
241.00
242.00
243.00
244.00
245.00
246.00
247.00
250.00
275.00
300.00
301.00
302.00
360.00
380.00
400.00
500.00
600.00
700.00
800.00
900.00
1000.00
2000.00
3000.00
4000.00
INSERTION LOSS
at RF level of 0 dBm
RF OUT
20
Frequency
(MHz)
100
VSWR
(:1)
0
1000
2000
3000
0
4000
1000
2000
3000
4000
FREQUENCY (MHz)
FREQUENCY (MHz)
Mini-Circuits
®
EW
ALL N
minicircuits.com
ISO 9001 ISO 14001 CERTIFIED
P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661 For detailed performance specs & shopping online see Mini-Circuits web site
The Design Engineers Search Engine Provides ACTUAL Data Instantly From MINI-CIRCUITS At: www.minicircuits.com
RF/IF MICROWAVE COMPONENTS
REV. C
M113397
BHP-400+
080603
Similar pages