DALLAS DS1904

PRELIMINARY
DS1904
RTC iButton
www.iButton.com
SPECIAL FEATURES
Real-Time Clock/calendar in binary format
Uses the same binary time/date representation
as the DS1994 but with 1 second resolution
Clock accuracy is better than ± 2 minutes per
month at 25°C
Operating temperature range from -40°C to
+70°C
Over 10 years of operation
Presence detector acknowledges when reader
first applies voltage
Meets UL#913 (4th Edit.); Intrinsically Safe
Apparatus, Approved under Entity Concept
for use in Class I, Division 1, Group A, B, C
and D Locations (application pending)
F5 MicroCan

5.89
COMMON iButton FEATURES
Unique, factory–lasered and tested 64-bit
registration number (8-bit family code + 48bit serial number + 8-bit CRC tester) assures
absolute traceability because no two parts are
alike
Multidrop controller for MicroLAN
Digital identification and information by
momentary contact
Chip-based data carrier compactly stores information
Data can be accessed while affixed to object
Economically communicates to host with a
single digital signal at 16.3k bits per second
Standard 16 mm diameter and 1-Wire protocol ensure compatibility with iButton Device
family
Button shape is self-aligning with cup-shaped
probes
Durable stainless steel case engraved with
registration number withstands harsh environments
Easily affixed with self-stick adhesive backing, latched by its flange, or locked with a
ring pressed onto its rim
0.36
0.51
16.25
YYWW REGISTERED RR
40
24
17.35
000000FBC52B
DATA
GROUND
All dimensions are shown in millimeters
ORDERING INFORMATION
DS1904L-F5
F5 MicroCan
EXAMPLES OF ACCESSORIES
DS9096P
DS9101
DS9093RA
DS9093A
DS9092
Self-Stick Adhesive Pad
Multi-Purpose Clip
Mounting Lock Ring
Snap-In Fob
iButton Probe
iButton DESCRIPTION
The DS1904 RTC iButton is a rugged real-time clock module that can be accessed with minimal
hardware. Data is transferred serially via the 1-Wire protocol, which requires only a single data lead and a
ground return. The DS1904 contains a unique 64-bit factory-lasered ROM and a real-time clock/calendar
implemented as a binary counter. The durable MicroCan package is highly resistant to environmental
1 of 12
022400
DS1904
hazards such as dirt, moisture, and shock. Accessories permit the DS1904 to be mounted on almost any
surface including printed circuit boards and plastic key fobs. The DS1904 adds functions such as
calendar, time and date stamp, stopwatch, hour meter, interval timer, and logbook to any type of
electronic device or embedded application that uses a microcontroller.
OVERVIEW
The DS1904 has two main data components: 1) 64-bit lasered ROM, and 2) real-time clock counter
(Figure 1). The real-time clock utilizes an on-chip oscillator that is connected to a 32.768 kHz crystal.
The hierarchical structure of the 1-Wire protocol is shown in Figure 2. The bus master must first provide
one of four ROM function commands: 1) Read ROM, 2) Match ROM, 3) Search ROM, 4) Skip ROM.
The protocol for these ROM functions is described in Figure 7. After a ROM function command is
successfully executed, the real-time clock functions become accessible and the master may then provide
one of the real-time clock function commands. The protocol for these commands is described in Figure 5.
All data is read and written least significant bit first.
BLOCK DIAGRAM Figure 1
LID
CONTACT
DATA
ROM
FUNCTION
CONTROL
64-BIT
LASERED
ROM
CLOCK
FUNCTION
CONTROL
READ/WRITE BUFFER
3V
LITHIUM
RTC COUNTER (32-BIT)
OSCILLATOR
CONTROL
32.768 kHz
OSCILLATOR
1 Hz
DIVIDER
64-BIT LASERED ROM
Each DS1904 contains a unique ROM code that is 64 bits long. The first eight bits are a 1-Wire family
code. The next 48 bits are a unique serial number. The last eight bits are a CRC of the first 56 bits. (See
Figure 3.) The 1-Wire CRC is generated using a polynomial generator consisting of a shift register and
XOR gates as shown in Figure 4. The polynomial is X8 + X5 + X4 + 1. Additional information about the
Dallas Semiconductor 1-Wire Cyclic Redundancy Check is available in the Book of DS19xx iButton
Standards. The shift register bits are initialized to zero. Then starting with the least significant bit of the
family code, one bit at a time is shifted in. After the 8th bit of the family code has been entered, then the
serial number is entered. After the 48th bit of the serial number has been entered, the shift register
contains the CRC value. Shifting in the eight bits of CRC should return the shift register to all zeros. The
64-bit ROM and ROM Function Control section allow the DS1904 to operate as a 1-Wire device and
follow the 1-Wire protocol detailed in the section "1-Wire Bus System".
2 of 12
DS1904
HIERARCHICAL STRUCTURE FOR 1-WIRE PROTOCOL Figure 2
1-Wire Bus
Bus
Master
Other
Devices
DS1904
Command
Level
1-Wire ROM
Commands (see Figure
DS1904
Function
(see Figure
Available
Commands
Data Fields
Affected
Read
Match
Search
Skip
64-bit
64-bit
64-bit
N/A
Write
Read
RTC Counter, Device
RTC Counter, Device
64-BIT LASERED ROM Figure 3
MSB
LSB
8-Bit CRC Code
MSB
48-Bit Serial Number
LSB
MSB
8-Bit Family Code (24h)
LSB
MSB
LSB
1-WIRE CRC GENERATOR Figure 4
Polynomial = X8 + X5 + X4 + 1
R
1ST
STAGE
X0
2ND
STAGE
X1
X2
3RD
STAGE
4TH
STAGE
X3
5TH
STAGE
X4
S
6TH
STAGE
X5
X6
7TH
STAGE
8TH
STAGE
X7
INPUT DATA
3 of 12
X8
DS1904
TIMEKEEPING
A 32.768 kHz crystal oscillator is used as the time base for the real-time clock counter. The oscillator can
be turned on or off under software control. The oscillator must be on for the real time clock to function.
The real-time clock counter is double buffered. This allows the master to read time without the data
changing while it is being read. To accomplish this, a snapshot of the counter data is transferred to a
read/write buffer, which the user accesses.
DEVICE CONTROL BYTE
The on/off control of the 32.768 kHz crystal oscillator is done through the device control byte. This byte
can be read and written through the Clock Function commands.
Device Control Byte
7
6
5
U4
U3
U2
Bit 0 - 1
0
4
U1
3
OSC
2
OSC
1
0
0
0
No function
Bits 0 and 1 are hard-wired to read all 0’s.
Bit 2 - 3
OSC
Oscillator Enable/Disable
These bits control/report whether the 32.768 kHz crystal oscillator is running. If the oscillator is running,
both OSC bits will read 1. If the oscillator is turned off these bits will all read 0. When writing the device
control byte both occurrences of the OSC bit should have identical data. Otherwise the value in bit address 3 (bold) takes precedence.
Bit 4 - 7
Un
General-purpose user flags
These non-volatile bits have no particular function within the chip. They can be read and written under
the control of the application software.
REAL-TIME CLOCK
The real-time clock is a 32-bit binary counter. It is incremented once per second. The real-time clock can
accumulate 136 years of seconds before rolling over. Time/date is represented by the number of seconds
since a reference point, which is determined by the user. For example, 12:00 a.m., January 1, 1970 could
be a reference point.
CLOCK FUNCTION COMMANDS
The “Clock Function Flow Chart” (Figure 5) describes the protocols necessary for accessing the real-time
clock. With only four bytes of real-time clock and one control byte the DS1904 does not provide random
access. Reading and writing always starts with the device control byte followed by the least significant
byte of the time data.
4 of 12
DS1904
CLOCK FUNCTION COMMAND FLOW CHART Figure 5
Master TX Control
Function Command
66H
Read Clock
?
Y
99H
Write Clock
?
Y
N
DS1904 copies
RTC Counter
to R/W Buffer
N
Bus Master TX
Device Control Byte
Bus Master RX
Device Control Byte
Bus Master TX
LS Byte (7:0)
Bus Master RX
LS Byte (7:0)
Bus Master TX
next Byte (15:8)
Bus Master RX
next Byte (15:8)
Bus Master TX
next Byte (23:16)
Bus Master RX
next Byte (23:16)
Bus Master TX
MS Byte (31:24)
Bus Master RX
MS Byte (31:24)
N
N
Bus Master
TX Reset
?
Y
Bus Master
TX Reset
?
Y
DS1904 copies
R/W Buffer
to RTC Counter
DS1904 TX
Presence Pulse
5 of 12
N
Bus Master
TX Reset
?
Y
DS1904
READ CLOCK [66h]
The read clock command is used to read the device control byte and the contents of the real-time clock
counter. After having received the most significant bit of the command code the device copies the actual
contents of the real-time clock counter to the read/write buffer. Now the bus master reads data beginning
with the device control byte followed by the least significant byte through the most significant byte of the
real-time clock. After this the bus master may continue reading from the DS1904. The data received will
be the same as in the first pass through the command flow. The read clock command can be ended at any
point by issuing a Reset Pulse.
WRITE CLOCK [99h]
The write clock command is used to set the real-time clock counter and to write the device control byte.
After issuing the command, the bus master writes first the device control byte, which becomes immediately effective. After this the bus master sends the least significant byte through the most significant byte
to be written to the real-time clock counter. The new time data is copied from the read/write buffer to the
real-time clock counter and becomes effective as the bus master generates a reset pulse. If the oscillator is
intentionally stopped, the real-time clock counter behaves as a four-byte non-volatile memory.
1-WIRE BUS SYSTEM
The 1-Wire bus is a system, which has a single bus master and one or more slaves. In all instances the
DS1904 is a slave device. The bus master is typically a microcontroller. The discussion of this bus system
is broken down into three topics: hardware configuration, transaction sequence, and 1-Wire signaling
(signal types and timing). A 1-Wire protocol defines bus transactions in terms of the bus state during
specified time slots that are initiated on the falling edge of sync pulses from the bus master. For a more
detailed protocol description, refer to Chapter 4 of the Book of DS19xx iButton Standards.
HARDWARE CONFIGURATION Figure 6
BUS MASTER
Open Drain
Port Pin
VPUP
DS1904 1-WIRE PORT
5 kΩ
Typ.
DATA
RX
TX
TX
RX = RECEIVE
TX = TRANSMIT
RX
5 µA
Typ.
100 Ω
MOSFET
Hardware Configuration
The 1-Wire bus has only a single line by definition; it is important that each device on the bus be able to
drive it at the appropriate time. To facilitate this, each device attached to the 1-Wire bus must have open
drain or 3-state outputs. The 1-Wire input of the DS1904 is open drain with an internal circuit equivalent
to that shown in Figure 6. A multidrop bus consists of a 1-Wire bus with multiple slaves attached. The 1Wire bus has a maximum data rate of 16.3k bits per second and requires a pull-up resistor of approximately 5kΩ.
6 of 12
DS1904
The idle state for the 1-Wire bus is high. If for any reason a transaction needs to be suspended, the bus
MUST be left in the idle state if the transaction is to resume. If this does not occur and the bus is left low
for more than 120 µs, one or more of the devices on the bus may be reset. Since the DS1904 gets all its
energy for operation through its VDD pin it will NOT perform a power-on reset if the 1-Wire bus is low
for an extended time period.
Transaction Sequence
The protocol for accessing the DS1904 via the 1-Wire port is as follows:
• Initialization
• ROM Function Command
• Clock Function Command
INITIALIZATION
All transactions on the 1-Wire bus begin with an initialization sequence. The initialization sequence consists of a reset pulse transmitted by the bus master followed by presence pulse(s) transmitted by the
slave(s). The presence pulse lets the bus master know that the DS1904 is on the bus and is ready to
operate. For more details, see the “1-Wire Signaling” section.
ROM FUNCTION COMMANDS
Once the bus master has detected a presence, it can issue one of the four ROM function commands that
the DS1904 supports. All ROM function commands are eight bits long. A list of these commands follows
(refer to flowchart in Figure 7):
Read ROM [33h]
This command allows the bus master to read the DS1904’s 8-bit family code, unique 48-bit serial number, and 8-bit CRC. This command should only be used if there is a single slave on the bus. If more than
one slave is present on the bus, a data collision will occur when all slaves try to transmit at the same time
(open drain will produce a wired-AND result). The resultant family code and 48-bit serial number read by
the master will be invalid.
Match ROM [55h]
The match ROM command, followed by a 64-bit ROM sequence, allows the bus master to address a specific DS1904 on a multidrop bus. Only the DS1904 that exactly matches the 64-bit ROM sequence will
respond to the following clock function command. All slaves that do not match the 64-bit ROM sequence
will wait for a reset pulse. This command can be used with a single or multiple devices on the bus.
SEARCH ROM [F0h]
When a system is initially brought up, the bus master might not know the number of devices on the 1Wire bus or their 64-bit ROM codes. The search ROM command allows the bus master to use a process
of elimination to identify the 64-bit ROM codes of all slave devices on the bus. The search ROM process
is the repetition of a simple 3-step routine: read a bit, read the complement of the bit, then write the desired value of that bit. The bus master performs this 3-step routine on each bit of the ROM. After one
complete pass, the bus master knows the 64-bit ROM code of one device. Additional passes will identify
the ROM codes of the remaining devices. See Chapter 5 of the Book of DS19xx iButton Standards for a
comprehensive discussion of a search ROM, including an actual example.
7 of 12
DS1904
ROM FUNCTIONS FLOW CHART Figure 7
Master TX
Reset Pulse
DS1904 TX
Presence Pulse
Master TX ROM
Function Command
33H
Read ROM
Command
?
Y
DS1904 TX
Family Code
1 Byte
N
55H
Match ROM
Command
?
F0H
Search ROM
Command
?
Y
N
Y
DS1904 TX Bit 0
Master TX Bit 0
DS1904 TX Bit 0
Master TX Bit 0
N
Bit 0
Match ?
N
Bit 0
Match ?
Y
Y
DS1904 TX
Serial Number
6 Bytes
DS1904 TX Bit 1
Master TX Bit 1
DS1904 TX Bit 1
Master TX Bit 1
N
Bit 1
Match ?
N
Bit 1
Match ?
Y
Y
DS1904 TX Bit 63
DS1904 TX
CRC Byte
Master TX Bit 63
DS1904 TX Bit 63
Master TX Bit 63
Bit 63
Match ?
N
N
Bit 63
Match ?
Y
Y
Master TX Control
Function Command
(SEE FIGURE 5)
8 of 12
N
CCH
Skip ROM
Command
?
Y
N
DS1904
Skip ROM [CCh]
This command can save time in a single drop bus system by allowing the bus master to access the clock
functions without providing the 64-bit ROM code. If more than one slave is present on the bus and, for
example, a read command is issued following the Skip ROM command, data collision will occur on the
bus as multiple slaves transmit simultaneously (open drain pull-downs will produce a wired-AND result).
1–WIRE SIGNALING
The DS1904 requires strict protocols to ensure data integrity. The protocol consists of four types of signaling on one line: Reset Sequence with Reset Pulse and Presence Pulse, Write 0, Write 1 and Read Data.
Except for the presence pulse the bus master initiates all these signals.
The initialization sequence required to begin any communication with the DS1904 is shown in Figure 8.
A reset pulse followed by a presence pulse indicates the DS1904 is ready to send or receive data. The bus
master transmits (TX) a reset pulse (tRSTL, minimum 480 µs). The bus master then releases the line and
goes into receive mode (RX). The 1-Wire bus is pulled to a high state via the pull-up resistor. After
detecting the rising edge on the data line, the DS1904 waits (tPDH, 15-60 µs) and then transmits the
presence pulse (tPDL, 60-240 µs).
INITIALIZATION PROCEDURE “RESET AND PRESENCE PULSES” Figure 8
MASTER TX
"RESET PULSE"
MASTER RX "PRESENCE PULSE"
tRSTH
VPULLUP
VPULLUP MIN
VIH MIN
VIL MAX
0V
tRSTL
RESISTOR
MASTER
DS1904
*
**
tR
tPDH
tPDL
480 µs ≤ tRSTL < ∞*
480 µs ≤ tRSTH < ∞**
15 µs ≤ tPDH < 60 µs
60 ≤ tPDL < 240 µs
In order not to mask interrupt signaling by other devices on the 1-Wire bus tRSTL + tR should always be less than 960 µs.
Includes recovery time
READ/WRITE TIME SLOTS
The definitions of write and read time slots are illustrated in Figure 9. The master initiates all time slots
by driving the data line low. The falling edge of the data line synchronizes the DS1904 to the master by
triggering an internal delay circuit. During write time slots, the delay circuit determines when the DS1904
will sample the data line. For a read data time slot, if a “0” is to be transmitted, the delay circuit determines how long the DS1904 will hold the data line low. If the data bit is a “1”, the DS1904 will not hold
the data line low at all.
9 of 12
DS1904
READ/WRITE TIMING DIAGRAM Figure 9
Write-one Time Slot
tSLOT
VPULLUP
tREC
VPULLUP MIN
VIH MIN
DS1904
Sampling
VIL MAX
0V
tLOW1
15µs
(OD: 2µs)
(OD: 6µs)
60µs
60 µs≤ tSLOT < 120
1 µs ≤ tLOW1 < 15 µs
1 µs ≤ tREC < ∞
RESISTO
MASTER
Write-zero Time Slot
tREC
tSLOT
VPULLUP
VPULLUP MIN
VIH MIN
DS1904
Sampling Window
VIL MAX
0V
15µs
(OD: 2µs)
(OD: 6µs)
60µs
t LOW0
RESISTOR
60 µs ≤ tLOW0 < tSLOT < 120 µs
MASTER
1 µs ≤ tREC < ∞
Read-data Time Slot
tREC
tSLOT
VPULLUP
VPULLUP MIN
VIH MIN
Master
Sampling Window
VIL MAX
0V
tSU
tRELEASE
tLOWR
tRDV
RESISTOR
MASTER
DS1904
60 µs ≤ tSLOT < 120 µs
1 µs ≤ tLOWR < 15 µs
0 ≤ tRELEASE < 45 µs
10 of 12
1 µs ≤ tREC < ∞
tRDV = 15 µs
tSU < 1 µs
DS1904
PHYSICAL SPECIFICATION
Size
Weight
Humidity
Altitude
Expected Service Life
Safety
See mechanical drawing
3.3 grams
90% RH at 50°C
10000 feet
10 years at 25°C
Meets UL#913 (4th Edit.); Intrinsically Safe
Apparatus, Approval under Entity Concept for
use in Class I, Division 1, Group A, B, C and
D Locations (application pending)
ABSOLUTE MAXIMUM RATINGS*
Voltage on 1-Wire to Ground
Operating Temperature
Storage Temperature
-0.5V to +7.0V
-40°C to +70°C
-40°C to +70°C
* This is a stress rating only and functional operation of the device at these or any other conditions
above those indicated in the operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability.
DC ELECTRICAL CHARACTERISTICS
PARAMETER
Logic 1
Logic 0
Output Logic Low @ 4 mA
Output Logic High
Input Load Current
SYMBOL
VIH
VIL
VOL
VOH
IL
(VPUP=2.8V to 6.0V; -40°C to +70°C)
MIN
2.2
-0.3
TYP
MAX
6.0
0.8
0.4
VPUP
5
CAPACITANCE
PARAMETER
Capacitance 1-Wire
NOTES
1
1,5
1
1,2
3
(tA = 25°C)
SYMBOL
CIN
MIN
AC ELECTRICAL CHARACTERISTICS
PARAMETER
Time Slot
Write 1 Low Time
Write 0 Low Time
Read Low Time
Read Data Valid
Release Time
Read Data Setup
Recovery Time
Reset High Time
Reset Low Time
Presence Detect High
Presence Detect Low
UNITS
V
V
V
V
µA
SYMBOL
tSLOT
tLOW1
tLOW0
tLOWR
tRDV
tRELEASE
tSU
tREC
tRSTH
tRSTL
tPDH
tPDL
TYP
MAX
50
UNITS
pF
NOTES
(VPUP=2.8V to 6.0V; -40°C to +70°C)
MIN
60
1
60
1
0
1
480
480
15
60
11 of 12
TYP
exactly 15
15
MAX
120
15
120
15
45
1
960
60
240
UNITS
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
µs
NOTES
7
4
6
DS1904
NOTES:
1.
2.
3.
4.
All voltages are referenced to ground.
VPUP = external pull-up voltage.
Input load is to ground.
Read data setup time refers to the time the host must pull the 1-Wire bus low to read a bit. Data is
guaranteed to be valid within 1 µs of this falling edge.
5. Under certain low voltage conditions VIL1MAX may have to be reduced to as much as 0.5V to always
guarantee a presence pulse.
6. The reset low time (tRSTL) should be restricted to a maximum of 960 µs, to allow interrupt signaling,
otherwise, it could mask or conceal interrupt pulses.
7. The master must read while the data is valid.
12 of 12