INTERSIL MUR3040PT

MUR3040PT, RURH1540CC, MUR3060PT,
RURH1560CC
Data Sheet
January 2000
File Number
2774.4
15A, 400V - 600V Ultrafast Dual Diodes
Features
MUR3040PT, RURH1540CC, MUR3060PT, and
RURH1560CC are ultrafast dual diodes (trr < 55ns) with
soft recovery characteristics. They have a low forward
voltage drop and are of planar, silicon nitride passivated,
ion-implanted, epitaxial construction.
• Ultrafast with Soft Recovery . . . . . . . . . . . . . . . . . . . <55ns
These devices are intended for use as energy
steering/clamping diodes and rectifiers in a variety of
switching power supplies and other power switching
applications. Their low stored charge and ultrafast recovery
with soft recovery characteristics minimizes ringing and
electrical noise in many power switching circuits thus
reducing power loss in the switching transistor.
• Planar Construction
• Operating Temperature. . . . . . . . . . . . . . . . . . . . . . .175oC
• Reverse Voltage Up to . . . . . . . . . . . . . . . . . . . . . . . .600V
• Avalanche Energy Rated
Applications
• Switching Power Supply
• Power Switching Circuits
• General Purpose
Formerly developmental type TA09905.
Packaging
Ordering Information
PART NUMBER
JEDEC TO-218AC
PACKAGE
BRAND
MUR3040PT
TO-218AC
MUR3040PT
RURH1540CC
TO-218AC
RURH1540C
MUR3060PT
TO-218AC
MUR3060PT
RURH1560CC
TO-218AC
RURH1560C
ANODE 1
CATHODE
ANODE 2
CATHODE
(FLANGE)
NOTE: When ordering, use the entire part number.
Symbol
K
A2
A1
(Per Leg) TC = 25oC, Unless Otherwise Specified
MUR3040PT
RURH1540CC
Peak Repetitive Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VRRM
400
Absolute Maximum Ratings
Working Peak Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VRWM
DC Blocking Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VR
Average Rectified Forward Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IF(AV)
(TC = 145oC)
Repetitive Peak Surge Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IFRM
(Square Wave 20kHz)
Nonrepetitive Peak Surge Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IFSM
(Halfwave 1 Phase 60Hz)
Maximum Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PD
Avalanche Energy (See Figures 7 and 8) . . . . . . . . . . . . . . . . . . . . . . . . . . .EAVL
Operating and Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . TSTG, TJ
1
MUR3060PT
RURH1560CC
UNITS
400
400
15
600
600
600
15
V
V
V
A
42
30
A
200
200
A
100
20
-55 to 175
100
20
-55 to 175
W
mJ
oC
1-888-INTERSIL or 321-724-7143 | Copyright
© Intersil Corporation 2000
MUR3040PT, RURH1540CC, MUR3060PT, RURH1560CC
(Per Leg) TC = 25oC, Unless Otherwise Specified
Electrical Specifications
MUR3040PT, RURH1540CC
MUR3060PT, RURH1560CC
MIN
TYP
MAX
MIN
TYP
MAX
UNITS
IF = 15A
-
-
1.25
-
-
1.5
V
IF = 15A, TC = 150oC
-
-
1.12
-
-
1.2
V
VR = 400V
-
-
100
-
-
-
µA
VR = 600V
-
-
-
-
-
100
µA
VR = 400V, TC = 150oC
VR = 600V, TC = 150oC
-
-
500
-
-
-
µA
-
-
-
-
-
500
µA
IF = 1A, dIF/dt = 100A/µs
-
-
55
-
-
55
ns
IF = 15A, dIF/dt = 100A/µs
-
-
60
-
-
60
ns
ta
IF = 15A, dIF/dt = 100A/µs
-
30
-
-
30
-
ns
tb
IF = 15A, dIF/dt = 100A/µs
-
17
-
-
20
-
ns
1.5
oC/W
SYMBOL
TEST CONDITION
VF
IR
trr
RθJC
-
-
1.5
-
-
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300µs, D = 2%).
IR = Instantaneous reverse current.
trr = Reverse recovery time at dIF/dt = 100A/µs (See Figure 6), summation of ta + tb.
ta = Time to reach peak reverse current at dIF/dt = 100A/µs (See Figure 6).
tb = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 6).
RθJC = Thermal resistance junction to case.
pw = pulse width.
D = duty cycle.
Typical Performance Curves
500
80
IR, REVERSE CURRENT (µA)
IF, FORWARD CURRENT (A)
100
175oC
10
100oC
25oC
175oC
10
1.0
100oC
0.1
0.01
25oC
1
0.001
0
0.5
1.0
1.5
VF, FORWARD VOLTAGE (V)
FIGURE 1. FORWARD CURRENT vs FORWARD VOLTAGE
2
2.0
0
100
200
300
400
500
VR, REVERSE VOLTAGE (V)
FIGURE 2. REVERSE CURRENT vs REVERSE VOLTAGE
600
MUR3040PT, RURH1540CC, MUR3060PT, RURH1560CC
Typical Performance Curves
IF(AV) , AVERAGE FORWARD CURRENT (A)
60
50
t, TIME (ns)
40
trr
30
ta
20
tb
10
0
10
1
20
16
14
DC
12
SQ. WAVE
10
8
6
4
2
0
120
130
140
150
160
170
180
TC, CASE TEMPERATURE (oC)
IF, FORWARD CURRENT (A)
FIGURE 3. trr, ta AND tb CURVES vs FORWARD CURRENT
FIGURE 4. CURRENT DERATING CURVE
Test Circuits and Waveforms
VGE AMPLITUDE AND
RG CONTROL dIF/dt
t1 AND t2 CONTROL IF
L
DUT
CURRENT
SENSE
RG
IF
+
VGE
-
IGBT
t1
VDD
dIF
trr
dt
ta
tb
0
0.25 IRM
t2
IRM
FIGURE 5. trr TEST CIRCUIT
FIGURE 6. trr WAVEFORMS AND DEFINITIONS
I = 1A
L = 40mH
R < 0.1Ω
EAVL = 1/2LI2 [VR(AVL) /(VR(AVL) - VDD)]
Q1 = IGBT (BVCES > DUT VR(AVL))
VAVL
L
CURRENT
SENSE
R
+
VDD
IL
IL
I V
Q1
VDD
DUT
t0
FIGURE 7. AVALANCHE ENERGY TEST CIRCUIT
t1
t2
t
FIGURE 8. AVALANCHE CURRENT AND VOLTAGE
WAVEFORMS
All Intersil semiconductor products are manufactured, assembled and tested under ISO9000 quality systems certification.
Intersil semiconductor products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see web site www.intersil.com
3