MAXIM MAX4826ELT

19-3672; Rev 0; 5/05
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN
Features
The MAX4826–MAX4831 family of switches has internal
current limiting to prevent host devices from being
damaged due to faulty load conditions. These analog
switches have a low 0.7Ω on-resistance and operate
from a +2.3V to +5.5V input voltage range. These
devices are available with guaranteed 50mA and
100mA current limits, making them ideal for loadswitching applications. In addition to the current-limit
fault flag (FFLG), an open-drain no-load flag indicator
(NOLD) notifies the system when the current through
the switch is less than 10mA (MAX4826–MAX4829), or
5mA (MAX4830/MAX4831).
When the switch is on and a load is connected to the
port, a guaranteed blanking time of 14ms ensures that
the transient voltages settle down. If, after this blanking
time, the load current is greater than the current limit,
the MAX4826/MAX4828/MAX4830 enter a latch-off state
where the switch is turned off, and FFLG is issued to
the microprocessor. The switch can be turned on again
by cycling the power or ON.
The MAX4827/MAX4829/MAX4831 have an autoretry
feature where the switch turns off after the blanking
time, and then continuously checks to see if the overload condition is present. The current-limit fault flag
(FFLG) is issued and remains low until after the fault
condition is removed. The switch remains on after the
overload condition disappears.
The MAX4826–MAX4831 operate over the extended
-40°C to +85°C temperature range, and are available in a
tiny space-saving, 1mm x 1.5mm, 6-pin µDFN package.
♦ Guaranteed Current Limit: 50mA, 100mA
♦ Thermal Shutdown Protection
♦ Reverse-Current Protection
♦ 0.7Ω On-Resistance (MAX4826–MAX4831)
♦ 14ms Guaranteed Blanking Time
♦ Fault Flag (FFLG)
♦ No-Load Flag (NOLD)
♦ 65µA Supply Current
♦ 8µA Latch-Off Current
♦ 0.01µA Shutdown Current
♦ +2.3V to +5.5V Supply Range
♦ Undervoltage Lockout
♦ Fast Current-Limit Response Time
♦ 6-Pin µDFN Package (1mm x 1.5mm)
Applications
GPS Systems
Cell Phones
Digital Still Cameras
PDAs and Palmtop Devices
MP3 Players
Ordering Information/Selector Guide
PART
PINPACKAGE
MIN FULLLOAD LIMIT
(mA)
MAX NOLOAD LIMIT
(mA)
ON-RESISTANCE
(Ω)
TA = +25°C
MODE
TOP
MARK
PKG
CODE
MAX4826ELT
6 µDFN
50
10
1
Latch Off
AK
L611-1
MAX4827ELT*
6 µDFN
50
10
1
Autoretry
AL
L611-1
MAX4828ELT*
6 µDFN
100
10
1
Latch Off
AM
L611-1
MAX4829ELT
6 µDFN
100
10
1
Autoretry
AN
L611-1
MAX4830ELT
6 µDFN
50
5
2
Latch Off
AO
L611-1
MAX4831ELT*
6 µDFN
50
5
2
Autoretry
AP
L611-1
Note: All devices operate over the -40°C to +85°C operating range.
*Future product—contact factory for availability.
Pin Configuration appears at end of data sheet.
________________________________________________________________ Maxim Integrated Products
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
1
MAX4826–MAX4831
General Description
MAX4826–MAX4831
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN
ABSOLUTE MAXIMUM RATINGS
IN, ON, FFLG, NOLD, OUT to GND .........................-0.3V to +6V
OUT Short Circuit to GND .................................Internally Limited
Continuous Power Dissipation (TA = +70°C)
6-Pin µDFN (derate 2.1mW/C above +70°C) ...............168mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VIN = +2.3V to +5.5V, TA = -40°C to +85°C, unless otherwise noted. Typical values are at VIN = +3.3V, TA = +25°C.) (Note 1)
PARAMETER
Operating Voltage
Quiescent Current
Latch-Off Current (Note 2)
Shutdown Current
Shutdown Reverse Leakage
Forward-Current Limit
Reverse-Current Limit
SYMBOL
CONDITIONS
VIN
IQ
VON = VIN, IOUT = VIN = +2.3V to +5.0V
0, switch on
VIN = +5.0V to +5.5V
VON = VIN = 3.3V, after an overcurrent fault
(MAX4826/MAX4828/MAX4830)
ISHDN
IFWD
IREV
TYP
2.3
ILATCH
ISHDNRV
MIN
65
MAX
UNITS
5.5
V
100
120
µA
8
15
µA
VON = 0, IOUT = 0mA
0.01
1
µA
VON = 0, VIN = +2.3V, VOUT = +5.5V
0.01
1
µA
(MAX4826/MAX4827/MAX4830/MAX4831)
RL = 10Ω
50
120
(MAX4828/MAX4829) RL = 5Ω
100
240
VOUT - VIN < 0.5V
(MAX4826/MAX4827/MAX4830/MAX4831)
120
VOUT - VIN < 0.5V (MAX4828/MAX4829)
240
mA
mA
MAX4826–MAX4829
1.0
10.0
MAX4830/MAX4831
0.5
5.0
IONLK
VON = VIN or GND
-1
+1
µA
Off-Switch Leakage
ISWLK
VIN = +5.5V, VON = 0, VOUT = 0
1
µA
Undervoltage Lockout
UVLO
Rising edge
No-Load Threshold
INLTH
ON Input Leakage
Undervoltage Lockout Hysteresis
UVLOHYS
On-Resistance
RON
ON Input-Logic-High Voltage
VIH
ON Input-Logic-Low Voltage
VIL
FFLG, NOLD Output-Logic-Low
Voltage
2
0.01
1.8
2.2
100
V
mV
TA = +25°C, IOUT
= 20mA
(MAX4826–MAX4829)
0.7
1.0
(MAX4830/MAX4831)
1.4
2.0
TA = -40°C to
+85°C,
IOUT = 20mA
(MAX4826–MAX4829)
1.3
(MAX4830/MAX4831)
mA
Ω
2.6
2.0
ISINK = 1mA
_______________________________________________________________________________________
V
0.8
V
0.4
V
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN
MAX4826–MAX4831
ELECTRICAL CHARACTERISTICS (continued)
(VIN = +2.3V to +5.5V, TA = -40°C to +85°C, unless otherwise noted. Typical values are at VIN = +3.3V, TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
FFLG, NOLD Output-High
Leakage Current
CONDITIONS
MIN
TYP
MAX
UNITS
1
µA
VIN = VFFLG = VNOLD = +5.5V
Thermal Shutdown
Thermal-Shutdown Hysterisis
+150
°C
15
°C
DYNAMIC
Turn-On Time
ON from low to high; IOUT = 10mA,
CL = 0.1µF (Note 3)
50
µs
Turn-Off Time
ON from high to low; IOUT =10mA,
CL = 0.1µF (Note 3)
30
ns
Blanking Time
tBLANK
Overcurrent fault
14
60
ms
Short-Circuit Current-Limit
Response Time
VON = VIN = +3.3V, short circuit applied to
OUT
5
µs
No-Load-Detection Response
Time
IOUT falling step signal from 15mA to 0mA,
CL = 0.1µF
60
µs
Retry Time
tRETRY
Overcurrent fault (Figure 2) (Note 4)
196
840
ms
Note 1: All parts are 100% tested at TA = +25°C. Limits at TA = -40°C to +85°C are guaranteed by design.
Note 2: Latch-off current does not include the current flowing into FFLG and NOLD.
Note 3: Turn-on time is defined as the time taken for the current through the switch to go from 0mA to full load. Turn-off time is
defined as the time taken for the current through the switch to go from full load to 0mA.
Note 4: Retry time is typically 14x the blanking time.
Typical Operating Characteristics
(VIN = +3.3V, TA = +25°C, unless otherwise noted.)
70
60
50
40
30
70
VIN = 5V
60
50
VIN = 3.3V
40
30
20
20
10
10
0
VON = VIN
80
0
2.3
2.7
3.1
3.5
3.9
4.3
SUPPLY VOLTAGE (V)
4.7
5.1
5.5
-40
-15
10
35
TEMPERATURE (°C)
60
85
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
MAX4826 toc03
90
LATCH-OFF CURRENT
vs. TEMPERATURE
LATCH-OFF CURRENT (µA)
VON = VIN
VIN = +2.3V TO +5.5V
SUPPLY CURRENT (µA)
SUPPLY CURRENT (µA)
80
MAX4826 toc01
90
QUIESCENT SUPPLY CURRENT
vs. TEMPERATURE
MAX4826 toc02
QUIESCENT SUPPLY CURRENT
vs. SUPPLY VOLTAGE
VON = VIN
VIN = 5V
VIN = 3.3V
-40
-15
10
35
60
85
TEMPERATURE (°C)
_______________________________________________________________________________________
3
Typical Operating Characteristics (continued)
(VIN = +3.3V, TA = +25°C, unless otherwise noted.)
VIN = 5V
0.01
VIN = 3.3V
0.001
0.0001
0.1
VIN = 5V
0.01
VIN = 3.3V
0.001
-15
10
35
60
85
-40
-15
10
35
60
TEMPERATURE (°C)
LATCH-OFF-LEAKAGE CURRENT
vs. TEMPERATURE
NORMALIZED ON-RESISTANCE
vs. TEMPERATURE
VON = VIN = 3.3V
VIN = 5V
0.01
VIN = 3.3V
-40
85
1.0
0.8
0.6
0.4
10
35
60
85
250
-15
10
35
SWITCH TURN-ON/OFF TIMES
vs. TEMPERATURE
MAX4828/MAX4829
150
100
60
85
0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3
VIN - VOUT (V)
VIN = 5V
0.1
OFF
0.01
MAX4826 toc11
40
35
FLAG-BLANKING TIME (ms)
ON
10
TURN-ON/OFF TIMES (µs)
MAX4826/MAX4827/MAX4830/MAX4831
FLAG-BLANKING TIMEOUT
vs. TEMPERATURE
MAX4826 toc10
100
30
25
20
15
ILOAD = -10mA
0.001
-40
-15
10
10
35
TEMPERATURE (°C)
85
200
TEMPERATURE (°C)
VIN = 3.3V
60
0
-40
TEMPERATURE (°C)
1
35
300
0
-15
10
50
0.2
-40
-15
OUTPUT CURRENT vs. OUTPUT VOLTAGE
0.001
0.0001
0.001
OUTPUT CURRENT (mA)
NORMALIZED RON
1.2
0.1
0.01
MAX4826 toc08
1.4
MAX4826 toc07
1
0.1
TEMPERATURE (°C)
TEMPERATURE (°C)
10
1
0.0001
0.0001
-40
VON = VIN = OV
VOUT = 5V
MAX4826 toc09
0.1
1
10
REVERSE LEAKAGE CURRENT (nA)
SHUTDOWN LEAKAGE CURRENT (nA)
1
MAX4826 toc05
10
MAX4826 toc04
SHUTDOWN SUPPLY CURRENT (nA)
10
4
SHUTDOWN REVERSE LEAKAGE CURRENT
vs. TEMPERATURE
SHUTDOWN LEAKAGE CURRENT
vs. TEMPERATURE
MAX4826 toc06
SHUTDOWN SUPPLY CURRENT
vs. TEMPERATURE
LATCH-OFF-LEAKAGE CURRENT (nA)
MAX4826–MAX4831
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN
60
85
-40
-15
10
35
60
85
TEMPERATURE (°C)
_______________________________________________________________________________________
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN
CURRENT-LIMIT RESPONSE
CURRENT-LIMIT RESPONSE
MAX4826 toc13
MAX4826 toc12
VON = 3.3V
VOUT = GND
VON = 3.3V
VOUT = GND
CIN = 1µF
COUT = 1µF
CIN = 1µF
COUT = 1µF
VIN
2V/div
VIN = VON
1V/div
VON
2V/div
IOUT
100mA/div
IOUT
100mA/div
20µs/div
40µs/div
CURRENT-LIMIT RESPONSE
(OUT SHORTED TO GND)
SWITCH TURN-ON-TIME RESPONSE
MAX4826 toc15
MAX4826 toc14
VIN
2V/div
VIN = 3.3V
ILOAD = 10mA
VON
2V/div
VOUT
2V/div
IOUT
100mA/div
IOUT
2A/div
100µs/div
40µs/div
SWITCH TURN-OFF-TIME RESPONSE
FLAG-BLANKING RESPONSE
MAX4826 toc16
MAX4826 toc17
VIN
2V/div
VIN = 3.3V
ILOAD = 10mA
VON
2V/div
VON
2V/div
FFLG
2V/div
IOUT
10mA/div
IOUT
100mA/div
100ns/div
4ms/div
_______________________________________________________________________________________
5
MAX4826–MAX4831
Typical Operating Characteristics (continued)
(VIN = +3.3V, TA = +25°C, unless otherwise noted.)
MAX4826–MAX4831
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN
Pin Description
PIN
NAME
1
IN
FUNCTION
2
GND
Ground
3
OUT
Switch Output. Bypass OUT with a 0.1µF capacitor to ground
4
FFLG
Current-Limit Fault Output. FFLG is an open-drain output. FFLG goes low when the device stays in
forward- or reverse-current limit for more than the blanking time period. FFLG is high impedance
when a fault is not present or when ON is low.
5
NOLD
No-Load Flag Output. NOLD is an open-drain output. NOLD goes low when a load of less than 10mA
(MAX4826–MAX4829) or 5mA (MAX4830/MAX4831) is delivered to the output. NOLD is high
impedance when a fault is not present or when ON is low.
6
ON
Input. Bypass IN with a 0.1µF ceramic capacitor to ground.
Active-High Switch-On Input. Drive ON high to turn the switch on.
Detailed Description
The MAX4826–MAX4831 are forward-/reverse-currentlimited switches that operate from a +2.3V to +5.5V
input voltage range and guarantee a 50mA and 100mA
minimum current-limit threshold for different options.
The voltage drop across an internal sense resistor is
compared to two reference voltages to indicate a forward- or reverse-current-limit fault. When the load current exceeds the preset current limit for greater than
the fault-blanking time, the switch opens.
The MAX4827/MAX4829/MAX4831 have an autoretry
function that turns on the switch again after an internal
retry time expires. If the faulty load condition is still present after the blanking time, the switch turns off again
and the cycle is repeated. If the faulty load condition is
not present, the switch remains on.
The MAX4826/MAX4828/MAX4830 do not have the
autoretry option, and the switch remains in latch-off
mode until ON or the input power is cycled from high to
low and then high again.
The undervoltage lockout (UVLO) circuit prevents erroneous switch operation when the input voltage goes too
low during startup conditions.
Reverse-Current Protection
The MAX4826–MAX4831 limit the reverse current (VOUT
to VIN) from exceeding the maximum IREV value. The
switch is shut off and FFLG is asserted if the reversecurrent-limit condition persists for more than the blanking time. This feature prevents excessive reverse currents from flowing through the device.
Switch-On/Off Control
Toggle ON high to enable the current-limited switches.
The switches are continuously on only if VIN exceeds
the UVLO threshold (typically 2V) and there is no fault.
When a forward-/reverse-current fault is present or the
die exceeds the thermal-shutdown temperature of
+150°C, OUT is internally disconnected from IN, and
the supply current decreases to 8µA (latch off). The
switch is now operating in one of its off states. The
switch off state also occurs when driving ON low, thus
reducing the supply current (shutdown) to 0.01µA.
Table 1 illustrates the ON/OFF state of the MAX4826–
MAX4831 current-limit switches.
Table 1. MAX4826–MAX4831 Switch Truth Table
ON
FAULT
Low
X
OFF
High
Undervoltage lockout
OFF
Latch off
High
Thermal
OFF immediately (tBLANK period does not apply).
Latch off
OFF after tBLANK period has elapsed.
Latch off
High
6
Current limit
SWITCH ON/OFF
ON during tBLANK period, OFF during tRETRY period for the
MAX4827/MAX4829/MAX4831. Cycle repeats until fault is
removed.
SUPPLY CURRENT MODE
Shutdown
See the Autoretry section
_______________________________________________________________________________________
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN
tBLANK
NO-LOAD
THRESHOLD
VON
CURRENT
LIMIT
tBLANK
CURRENT
LIMIT
SHORT
CONDITION
REMOVED
LOAD
CURRENT
LOAD
CURRENT
ON
60µs
60µs
NOLD
STATUS
SWITCH
STATUS
OFF
Figure 1. MAX4826–MAX4831 No-Load Flag Response
Figure 2. MAX4827/MAX4829/MAX4831 Autoretry Fault
Blanking Diagram
FFLG Indicator
The MAX4826–MAX4831 feature a current-limit fault
output, FFLG. Whenever a current-limit fault is activated, FFLG goes low and the switch turns off. FFLG is an
open-drain output transistor and requires an external
pullup resistor from FFLG to IN. During shutdown (ON
is low), the pulldown on the FFLG output is released to
limit power dissipation. FFLG goes low when any of the
following conditions occur:
• The die temperature exceeds the thermal shutdown temperature limit of +150°C.
• The device is in current limit for more than the
fault-blanking period.
• VIN is below the UVLO threshold.
tBLANK
LOAD
CURRENT
ON
SWITCH
STATUS
OFF
ON PIN
VOLTAGE
FFLG
PIN STATUS
(a)
NOLD Indicator
The MAX4826–MAX4831 feature a no-load flag output,
NOLD (Figure 1). This output is pulled low every time
the current coming out of the switch is less than 10mA
(MAX4826–MAX4829), or 5mA (MAX4830/MAX4831).
NOLD is an open-drain output transistor and requires
an external pullup resistor from NOLD to a supply up to
+5.5V. Current through the switch is intended to be
positive (from IN to OUT), and for currents that are
large in magnitude but negative in sign (OUT to IN),
NOLD asserts low. For options with the autoretry feature (MAX4827/MAX4829/MAX4831), the NOLD output
is high impedance during the tRETRY period when a forward-current-limit condition is present. However, NOLD
is pulled low if a reverse current-limit condition is present during the tRETRY period. A constant time filter is
present at the output of NOLD that gives a 60µs delay
when a no-load condition is asserted. Deassertion of
NOLD is not delayed. During shutdown (ON is low), the
pulldown on NOLD is released to limit power dissipation.
tBLANK
tBLANK
tBLANK
LOAD
CURRENT
ON
SWITCH
STATUS
IN PIN
VOLTAGE
OFF
UVLO
FFLG
PIN STATUS
(b)
Figure 3. MAX4826/MAX4828/MAX4830 Latch-Off Fault
Blanking
Autorety (MAX4827/MAX4829/MAX4831)
When the forward- or reverse-current-limit threshold is
exceeded, the tBLANK timer begins counting (Figure 2).
The timer resets if the overcurrent condition disappears
before tBLANK has elapsed. A retry time delay, tRETRY,
_______________________________________________________________________________________
7
MAX4826–MAX4831
tRETRY
tBLANK
VIN
MAX4826–MAX4831
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN
is started immediately after tBLANK has elapsed, and
during that time the switch is latched off. At the end of
tRETRY, the switch is turned on again. If the fault still
exists, the cycle is repeated. If the fault has been
removed, the switch stays on.
The autoretry feature saves system power in the case of
an overcurrent or short-circuit condition. During tBLANK,
when the switch is on, the supply current is at the current limit. During tRETRY, when the switch is off, no current flows through the switch. Instead of observing the
full load current, the switch sees the equivalent load
current, multiplied by the duty cycle or ISUPPLY = ILOAD
x tBLANK / (tBLANK + tRETRY). With a typical tBLANK =
37ms and typical tRETRY = 518ms, the duty cycle is 6%
which results in a 94% power savings, as opposed to
the switch being on the entire time. The duty cycle is
consistent across the process and devices.
Latch Off (MAX4826/MAX4828/MAX4830)
When the forward- or reverse-current-limit threshold is
exceeded, the tBLANK timer begins counting. The timer
resets if the overcurrent condition disappears before
tBLANK has elapsed. The switch is shut off if the overcurrent condition continues up to the end of the blanking time. Reset the switch by either toggling ON (Figure
3a), or cycling the input voltage below UVLO, typically
2V (Figure 3b).
Fault Blanking
The MAX4826–MAX4831 feature 14ms (min) fault blanking. Fault blanking allows current-limit faults, including
momentary short-circuit faults that occur when hot swapping a capacitive load. Fault blanking also ensures that
no fault is issued during power-up. When a load transient
causes the device to enter the current limit, an internal
counter starts. If the load-transient fault persists beyond
the fault-blanking timeout, FFLG asserts low. Load-transient faults less than tBLANK do not cause FFLG assertion. Only current-limit faults are blanked.
A thermal fault and input voltage drops below the UVLO
threshold cause FFLG to assert immediately. These
faults do not wait for the blanking time.
Thermal Shutdown
The MAX4826–MAX4831 have a thermal-shutdown feature to protect the devices from overheating. The switch
turns off and FFLG goes low immediately (no fault
blanking) when the junction temperature exceeds
+150°C. The switches with the autoretry feature turn
back on when the device temperature drops approximately 15°C. The switches with the latch-off feature
require ON cycling.
8
Applications Information
Input Capacitor
To limit the input voltage drop during momentary output
short-circuit conditions, connect a capacitor from IN to
GND. A 0.1µF ceramic capacitor is adequate for most
applications; however, higher capacitor values further
reduce the voltage drop at the input and are recommended for lower voltage applications.
Output Capacitance
Connect a 0.1µF capacitor from OUT to GND. This
capacitor helps prevent inductive parasitics from pulling
OUT negative during turn-off, thus preventing the
MAX4826–MAX4831 from tripping erroneously. If the
load capacitance is too large, current may not have
enough time to charge the capacitance, and the device
assumes that there is a faulty load condition. The maximum capacitive load value that can be driven from OUT
is obtained by the following formula:
CMAX <
IFWD _ MIN × tBLANK _ MIN
VIN
Layout and Thermal Dissipation
To optimize the switch response time to output shortcircuit conditions, it is very important to keep all traces
as short as possible to reduce the effect of undesirable
parasitic inductance. Place input and output capacitors
as close as possible to the device (no more than 5mm).
IN and OUT pins must be connected with short traces
to the power bus.
During normal operation, the power dissipation is small
and the package temperature change is minimal. If the
output is continuously shorted to ground at the maximum supply voltage, the operation of the switches with
the autoretry option does not cause problems because
the total power dissipated during the short is scaled by
the duty cycle:
PMAX <
VIN _ MAX × IOUT _ MAX × t BLANK
t RETRY + t BLANK
= 88mW
where,
VIN_MAX = 5.5V, IOUT_MAX = 240mA, tBLANK = 37ms,
and tRETRY = 518ms.
Attention must be given to the MAX4826/MAX4828/
MAX4830 where the latch-off condition must be manually
reset by toggling ON from high to low. If the latch-off time
duration is not sufficiently high, it is possible for the
device to reach the thermal shutdown threshold and
never be able to turn the device on until it cools down.
_______________________________________________________________________________________
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN
TRANSISTOR COUNT: 1175
PROCESS: BiCMOS
Typical Operating Circuit
Pin Configuration
+2.3V TO +5.5V
TOP VIEW OF BOTTOM LEADS
ON
NOLD
FFLG
6
5
4
IN
ON
MAX4826–
MAX4831
MAX4826–
MAX4831
µP
FFLG
NOLD
TO EXTERNAL PORT
OUT
1
IN
2
3
GND
OUT
GND
µDFN
Functional Diagram
CURRENT < 5mA DETECTOR (MAX4830/MAX4831)
CURRENT < 10mA DETECTOR (MAX4826–MAX4829)
NOLD
REVERSE-CURRENT
DETECTOR
N
FLAG
BLANKING-TIME
CIRCUITRY
N
GND
FORWARD-CURRENT
DETECTOR
ON
GND
N
IN
+2.0V
UNDERVOLTAGE
LOCKOUT
LOGIC
AUTORETRY
OUT
GND
MAX4826–MAX4831
_______________________________________________________________________________________
9
MAX4826–MAX4831
Chip Information
Package Information
6L UDFN.EPS
(The package drawing(s) in this data sheet may not reflect the most current specifications. For the latest package outline information,
go to www.maxim-ic.com/packages.)
3
e
A
b
5
4
6
TOPMARK
2
AAA
PIN 1
INDEX AREA
PIN 1
0.075x45°
L2
L
E
3
1
A1
D
SIDE VIEW
TOP VIEW
A
1
BOTTOM VIEW
b
SECTION A-A
2
A
L1
COMMON DIMENSIONS
MIN.
0.64
-1.45
0.95
0.30
--0.17
A
A1
D
E
L
L1
L2
b
e
NOM.
0.72
0.20
1.50
1.00
0.35
--0.20
0.50 BSC.
MAX.
0.80
-1.55
1.05
0.40
0.08
0.05
0.23
TITLE:
PACKAGE OUTLINE, 6L uDFN, 1.5x1.0x0.8mm
APPROVAL
DOCUMENT CONTROL NO.
21-0147
-DRAWING NOT TO SCALE-
REV.
C
1
1
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
10 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2005 Maxim Integrated Products
Printed USA
is a registered trademark of Maxim Integrated Products, Inc.
MAX4826–MAX4831
MAX4826–MAX4831
50mA/100mA Current-Limit Switches with
NO-LOAD Flag in µDFN