ETC N15P10E999X

ID 2011
V4.00
RF Coaxial Lightning
& EMP Protection
• In-line RF Coaxial Protection Against Lightning
& EMP
• Ideal Protection for Cellular Infrastructure
Equipment
• Available in l/4 Stub Tuner or Gas Discharge
Tube Formats
• Maintains Protection after Initial Strike or Pulse
M/A-COM offers a complete series of RF Coaxial Lightning &
EMP Protection Devices for use in cellular infrastructure applications. EMP (electro-magnetic pulse) occurs primarily as a
result of direct lightning strikes to infrastructure equipment
which can produce fast rising electric fields within micro
seconds. These electric fields induce high voltage pulses
through unprotected antennas and coaxial transmission
cables which can ultimately lead directly to the primary communication equipment. The EMP threat, generated from unpredictable lightning strikes is a serious concern for cellular
operators around the world. Damage from a lightning strike
can result in costly repair of equipment as well as significant
loss of airtime service to subscribers.
M/A-COM RF coaxial lightning protection (LP) devices have
been designed for use in commonly deployed cellular
infrastructure including GSM, NAMPS, PCS 1900 and
DCS 1800 operating formats. The use of coaxial lightning
protection has two primary benefits for cellular applications.
First, RF coaxial lightning protection can easily be inserted
into existing infrastructure architecture either as a cable
assembly or as an in-line adapter. This facilitates cell site
design and retrofit capabilities. Secondly, the RF coaxial
protection has been designed to facilitate and not degrade
RF performance during normal operation of the system.
Surge Protectors
These devices incorporate internal gas discharge tube (GDT)
technology to provide a low impedance path to discharge the
EMP to ground. The GDT is hermetically sealed with an inert
gas which is not radioactive and requires no special handling.
GDT devices are broadband due to their inherently small
capacitance and cover frequencies up to 2.5 GHz. Once a
GDT device has been activated with an impulse and the
voltage level dissipated, the device becomes inactive and will
require subsequent maintenance or replacement. Surge
protectors are available in convenient bulkhead mounting
configurations with a wide variety of standard interface
choices including Type N, 7-16 and SMA.
l/4 Stub Tuners
l/4 stub tuners are three port coaxial devices. The third port,
extending from the main electrical path, serves as a
terminated short circuit element at a predetermined distance
from the RF transmission path. This distance is designed to
be exactly one quarter wavelength at the desired centering
frequency (Fo). l/4 stub tuners offer very low VSWR and
feature very high attenuation of incoming pulses but must be
applied across relatively narrow bandwidths (± 70 MHz).
M/A-COM offers standard designs for the most popular
cellular frequency bands to facilitate usage without the need
for a custom design. Stub tuners offer the greatest protection
for sensitive electronic components as they have neither the
sparkover or residual voltage characteristics of GDT devices.
Stub tuners are extremely reliable and maintenance free
since they incorporate no active components. Standard stub
tuner designs exist for GSM, PCS 1900 and DCS 1800
frequencies with a wide variety of connector interfaces such
as Type N and 7-16 available. Cable assemblies, including
low loss cable options, are also available to provide complete
in-line solutions for base station design.
Call your local M/A-COM sales office or global Applications
Engineering group for more information on our RF coaxial
lightning protection. M/A-COM is an ISO-9001 globally
certified manufacturer.
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
North America:
1
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific: Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Application Information
l/4 Stub Tuners
• Ideal for use with GSM, PCS and DCS
• Maintenance Free Operation
• Low VSWR Within Specified Bandwidth
• Configurations include direct attachments to
Cable variants
• Optional White Bronze™ Finish
Description
l/4 stub tuners are three port coaxial devices which employ a
short circuit element as a means of protection against lightning
or EMP strikes. The third port, extending from the side of the
main transmission path of the connector, is terminated in a
short circuit at a predetermined distance from the main path.
The distance is calculated to be exactly one quarter
wavelength (l/4) at the desired centering frequency (Fo).
In order to offer the most flexible solutions for infrastructure
applications, stub tuners are available in either an individual
connector format or as a cable assembly ready for direct
installation into a RF coaxial transmission line. A wide variety
of interface styles are available to meet existing retrofit or new
design requirements including Type N, and 7-16. Standard
crimp tooling is available to facilitate direct connector
termination to RG58 or low loss Times™ T-Flex 402 cables.
Stub tuners, by the nature of their short circuit designs, do not
have a sparkover or residual voltage as found in surge
protectors. This ensures the greatest levels of protection
against repeated lightning or EMP strikes within specified
frequency bands. Stub tuners are also extremely reliable and
maintenance free since they contain no active parts. This
characteristic can be important when considering the total cost
of ownership, including the need for replacement or repair of
the device within difficult to reach infrastructure equipment.
Application Information
The centering frequency is an important selection criteria
because l/4 stub tuner design techniques restrict the
bandwidth in which acceptable VSWR performance can be
achieved. Stub tuners exhibit a v-shaped VSWR response.
Typically this bandwidth is 8% of the centering frequency.
Specified bandwidth in excess of 8% begins to experience
degradation of VSWR at the centering frequency. Stub tuners
are frequency specific in application as opposed to surge
protectors which address a wider spectrum of frequencies. As
a result of this restriction, M/A-COM offers a wide range of
standard stub tuner devices which address commonly
deployed cellular frequency bands such as GSM, NAMPS,
PCS 1900 and DCS 1800.
Some alternative plating finishes are available with M/A-COM’s
Stub Tuner Lightning products. Standard plating finishes are
shown within the data sheet, but alternatives are available by
customer request. Details of M/A-COM’s new “White Bronze”
finish are shown in the application notes associated with this
data sheet. For more detailed information, please contact your
local M/A-COM field sales office.
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
2
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific:
Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Specifications
l/4 Stub Tuners
Requirement
Detail (Type-N, 7-16)
Electrical
Impedance
VSWR Performance in Band
Insertion Loss (Typical)
DC Resistance (stub outer to inner)
Dynamic Voltage @ 250A/ms
Residual Voltage @ 2500A, 8/20ms
Outer Conductor Contact Resistance
DC Resistance (through-path center contact)
50Ω
≤1.2:1
±0.2dB
1mW max
≤15V
≤15V
≤10mV
100MW min
Materials
Body Parts
Gasket
Female Contacts
Male Contacts
Insulators
Brass
Silicone Rubber
Beryllium Copper
Brass
P.T.F.E.
Environmental
Operating temperature range
Relative humidity (non-condensing)
-45°C to +85°C
up to 100%
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
North America:
3
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific: Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
l/4 Stub Tuners – Product Offering
DCS 1800
Part Number
Type N Clamp Bulkhead Jack
13.6
.54
ACROSS
FLATS
16.0 DIA
.63
54.7 REF
2.15
.625-24
UNEF
19.0 HEX NUT
.750
LOCKWASHER
11.0
.43
ACROSS
FLATS
N15X12E470X
25.4 SQ
1.00
13.5
.53
ACROSS
FLATS
62.9 REF
2.48
23.5
.92 REF
MAX PANEL
10.0
THICKNESS .39
Cable
RECOMMENDED
MOUNTING HOLE
42.0
REF
1.65
T-Flex402
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
± 70 MHz
1795 MHz
6,0mm±0,5 Silver
6,0mm±0,5 Silver
10,00mm
CECC22210
0.7-1.1Nm
1.7Nm
500 Matings
WASHERS
7-16 Clamp Bulkhead Jack
72.7 REF
24.6 REF 2.86
4.0 REF
.97
.16
7.5
.30
11.0 ACROSS
MAX PANEL
.43 FLATS
THICKNESS
38.0 DIA
1.50 REF
27.2
1.07 REF
41.9
1.65
REF
29.5
1.16
DIA
25.4
1.0
SQUARE
M29 X 1.5
34.9 HEX NUT
1.37
GASKET
RECOMMENDED
MOUNTING HOLE
MAX PANEL
THICKNESS
7/16
JACK
M29 X 1.5
9.1
.36
27.4
1.08 REF
44.9 DIA
1.77 REF
33.0 SQUARE
1.3
17.5
.69
3.2
.13
25.4 SQ
1.00
13.5
.53
ACROSS FLATS
13.6
.54
ACROSS FLATS
16.0 DIA
.63
.625-24
UNEF
19.0 HEX
.750 NUT
LOCKWASHER
COPPER
WASHER
CRIMP
FERRULE
11.0 ACROSS
.43 FLATS
± 70 MHz
1795 MHz
6,0mm±0,5 Silver
6,0mm±0,5 Silver
10,00mm
CECC22190
25 - 30Nm
35Nm
500 Matings
D75X15B999X
± 70 MHz
1795 MHz
6,0mm±0,5 Silver
White Bronze
8,00mm
CECC22190
25 - 30Nm
35Nm
500 Matings
RECOMMENDED
MOUNTING HOLE
Type N Crimp Bulkhead Jack
62.9 REF
2.48
23.5
.92 REF
MAX PANEL
10.0
THICKNESS
.39
T-Flex402
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
30.5
1.20
67.0
2.64
REF
44.6 REF
1.76
7/16
JACK
M29 X 1.5
CASTLE NUT
COPPER
WASHER
D75X13E470X
Part Number
7-16 Jack to 7-16 Bulkhead Jack Adapter
77.6 REF
3.06
Cable
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
27.5
1.08
7/16
JACK
Part Number
54.7
2.15
42.0 REF
1.65
REF
RECOMMENDED
MOUNTING HOLE
Part Number
Cable
N15X18E010X
RG58C/U
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
± 70 MHz
1795 MHz
6,0mm±0,5 Silver
6,0mm±0,5 Silver
10,00mm
CECC22210
0.7-1.1Nm
1.7Nm
500 Matings
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
4
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific:
Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
l/4 Stub Tuners – Product Offering
DCS 1800
Type N Jack to Type N Bulkhead Jack Adapter
57.3
REF
2.26
23.5
.93 REF
10.0
MAX PANEL
THICKNESS
.39
25.4
SQ
1.00
13.5
.53 ACROSS FLATS
Part Number
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
13.6 ACROSS
FLATS
.54
16.0 DIA
.63
.625-24 UNEF
(2 PLACES)
19.0
HEX NUT
.750
LOCKWASHER
COPPER WASHER
54.7
REF
2.15
RECOMMENDED
MOUNTING HOLE
N15X16E999X
± 70 MHz
1795 MHz
6,0mm±0,5 Silver
6,0mm±0,5 Silver
10,00mm
CECC22210
0.7-1.1Nm
1.7Nm
500 Matings
42.0
REF
1.65
GSM
7-16 Bulkhead Jack to 7-16 Bulkhead Jack
Part Number
27.4
10.8 REF
77.6
3.06 REF
MAX PANEL 9.1
THICKNESS .36
7/16
JACK
M29X1.5
44.9 DIA
1.77 REF
7/16
JACK
M29X1.5
CASTLE
NUT
COPPER
WASHER
33.0
1.30 SQ.
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
30.5
1.20 DIA
93.4
3.68 REF
17.5
.69
32
.13
RECOMMENDED
MOUNTING HOLE
D75X07B999X
± 70 MHz
925 MHz
6,0mm±0,5 Silver
White Bronze
8,00mm
CECC22190
25 - 30Nm
35Nm
500 Matings
71.0
REF
2.79
PCS 1900
Type N Clamp Bulkhead Jack
25.4 SQ
1.00
62.9 REF
2.48
23.5
.92 REF
MAX PANEL
10.0
THICKNESS
.39
13.5
ACROSS FLATS
.53
.625-24 UNEF
19.0
HEX NUT
.750
LOCKWASHER
COPPER WASHER
11.0
.43
ACROSS
FLATS
13.6 ACROSS
.54
FLATS
16.0 DIA
.63
52.9
REF
RECOMMENDED
2.08
MOUNTING HOLE
40.2 REF
1.58
25.4
1.00 SQ
13.5
.53 ACROSS FLATS
23.5
.92
10.0
.39
MAX PANEL
THICKNESS
13.6
ACROSS
.54
FLATS
.625-24 UNEF
19.0 HEX NUT
.750
LOCKWASHER
N15X09E470X
T-Flex 402
52.9
REF RECOMMENDED
2.08
MOUNTING HOLE
40.2
REF
1.58
COPPER WASHER
± 70 MHz
1920 MHz
6,0mm±0,5 Silver
6,0mm±0,5 Silver
10,00mm
CECC22210
0.7-1.1Nm
1.7Nm
500 Matings
Part Number
Cable
N15X14E010X
RG58 C/U
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
16.0 DIA
.63
CRIMP
FERRULE
11.0 ACROSS
.43 FLATS
Cable
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
Type N Crimp Bulkhead Jack
62.9
REF
2.48
Part Number
± 70 MHz
1920 MHz
6,0mm±0,5 Silver
6,0mm±0,5 Silver
10,00mm
CECC22210
0.7-1.1Nm
1.7Nm
500 Matings
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
North America:
5
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific: Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
l/4 Stub Tuners – Product Offering
PCS 1900
7-16 Clamp Bulkhead Jack
38.0 DIA
1.50 REF
27.4
REF
1.08
72.7
REF
2.86
24.6
4.0
REF
REF
.97
.16
7.5 MAX
11.0 ACROSS
.30 PANEL
.43 FLATS
29.5
DIA
1.16
25.4
1.00
SQUARE
M29 X 1.5
34.9
HEX NUT
1.37
40.2 REF
1.58
Cable
D75X12E470X
T-Flex402
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
27.5
1.08
7/16
JACK
Part Number
1920 MHz
± 70 MHz
6,00mm ± 0,5 Silver
6,00mm ± 0.5 Silver
8.00mm
CECC 22190
25-30 Nm
35 Nm
500 Matings
RECOMMENDED
MOUNTING HOLE
GASKET
7-16 Bulkhead Jack to 7-16 Bulkhead Jack Adapter
77.6 REF
3.06
MAX PANEL
THICKNESS
30.5
1.20
17.5
.69
64.6
REF
2.54
7/16
JACK
M29 X 1.5
33.0
1.3
SQUARE
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
44.9 DIA
1.77 REF
27.4
9.1 1.08 REF
.36
7/16
JACK
Part Number
M29 X 1.5
42.2 REF
1.66
CASTLE NUT
COPPER WASHER
TYPE N
JACK
3.2
.13
Part Number
25.4
SQ
1.00
13.5
.53 ACROSS FLATS
TYPE N
JACK
.625-24 UNEF
(2 PLACES)
19.0
HEX NUT
.750
LOCKWASHER
COPPER WASHER
1920 MHz
± 70 MHz
6,00mm ± 0,5 Silver
White Bronze™
8.00mm
CECC 22190
25-30 Nm
35 Nm
500 Matings
RECOMMENDED
MOUNTING HOLE
Type N Bulkhead Jack to Type N Bulkhead Jack Adapter
57.3 REF
2.26
23.5 REF
.93
MAX PANEL
10.0
THICKNESS
.39
D75X14B999X
13.6
.54
ACROSS
FLATS
Bandwidth
Center Frequency
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
N15X17E999X
± 70 MHz
1920 MHz
6,0mm±0,5 Silver
6,0mm±0,5 Silver
10,00mm
CECC22210
0.7-1.1Nm
1.7Nm
500 Matings
16.0
DIA
.63
52.7 REF
2.08
RECOMMENDED
MOUNTING HOLE
40.0
1.58 REF
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
6
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific:
Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Interseries Cable Assemblies – Product Offering
A variety of options are available to ensure the proper cable
assembly selection can be made for your application. Please
specify the following parameters below:
C1:
F1:
I1:
I2:
T-Flex 402 or RG-58
Frequency Range (GSM, PCS 1900, DCS 1800)
7-16 or N Bulkhead Jack
SMA, N, 7-16 (Straight, Right Angle Plug or
Bulkhead Jack)
L1: Overall Length as Specified
M1: Required Marking
L1
CABLE LENGTH - MOUNTING SURFACE TO CENTER LINE
(RIGHT ANGLES) OR TO REFERENCE PLANE (STRAIGHTS)
I1
MARKER SLEEVE
TYPE N JACK l/4 STUB
TUNER CONNECTOR
SHOWN FOR REF
ONLY (SEE LIST OF
CONNECTOR OPTIONS)
M1
FLEXIBLE CABLE (C1)
SEE LIST OF OPTIONS
M/A-COM
SHRINK SLEEVE
(BOTH ENDS)
I2
TYPE N RIGHT ANGLE PLUG, SHOWN FOR REF ONLY
(SEE LIST OF CONNECTOR OPTIONS)
Cable Specifications
T-FLEX 402
RG-58
Materials:
Jacket
1st Shield
2nd Shield
Dielectric
Center Contact
FEP (Fluorinated Ethylene Propylene)
Silver Plated Copper Strip
Silver Plated Copper Braid
Extruded Solid Polytetrafluoroethylene
Silver Plated Copper
PVC(Polyvinyl Chloride)
Tinned Copper
N/A
Solid Polyethylene
Bare Copper
Minimum Bend Radius:
20.32 mm (.8inch)
25.5 mm (1 inch)
Impedance:
50 ohms
50 ohms
Insertion Loss:
.09 dB/Ft; .295dB/m @ 500 MHz
.13 dB/Ft; .427 dB/m @ 1GHz
.192 dB/Ft; .629 dB/m @ 2 GHz
.099 dB/Ft; .324 dB/m @ 500MHz
.143 dB/Ft; .47 dB/m @ 1 GHz
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
North America:
7
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific: Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Application Information
Surge Protectors
• Excellent for Broadband Frequency Applications
• Field Replaceable Gas Discharge Tube
• Available Interfaces Facilitate Retrofit Capabilities
• Low VSWR up to 2.5GHz
• Specialized White Bronze™ Finish
Description
Surge protectors incorporate hermetically sealed gas discharge tube (GDT) technology within the coaxial transmission
line to provide a low impedance path to discharge the EMP to
ground. The GDT is loaded into the connector housing from
the side via a weather sealed access port. The GDT does not
require special handling or safety precautions as the inert gas
used is non-radioactive. In an active state, the transversemounted GDT introduces some inherent extra capacitance
which is compensated electrically in the design and does not
degrade overall VSWR performance. As a result, M/A-COM
surge protectors perform well in applications up to 2.5 GHz.
Surge protectors are made active when a high voltage
impulse generated from a lightning or EMP source appears
on the coaxial line. The electric field produced causes the
inert gas to ionize which then creates a very low impedance
path to ground, thus directing the current away from sensitive
electronic elements. Once the impulse ceases and the voltage level reduces, the GDT becomes inactive again leaving a
residual voltage on the coaxial line. M/A-COM supplies
devices with a selection of GDT elements to carry 10kA, 20kA
or 50kA peak current. In addition, GDT devices are available
with a wide variety of interfaces such as type N, 7-16 and
SMA to facilitate retrofit installation.
Application Information
The significant advantage of using surge protectors is their
ability to handle a wide bandwidth from DC to 2.5 GHz.
Applications where multiple frequency bands need to be
transmitted at the same time also benefit from the surge protector design characteristics, i.e. the device is required to
pass DC or low frequency AC bias voltages as well as primary transmit or receive signals, but in addition required to stop
high voltage impulses. In operation, the gas discharge tube
continues to exhibit a voltage drop of about 20 volts while the
device remains in an energized state. It is important to note
that there will be a small period prior to the device becoming
active when high energy will be present on the transmission
line. This is because the ionization of the inert gas is inherently not instantaneous. The time taken for the GDT to become
fully active is determined by the rise time of the applied
impulse, typically in the order of 1kV/µS, and the impulse
sparkover voltage which is normally 800 volts. Standard
devices will therefore take 800nS typically to reach full condition. High energy for this period of time may not be acceptable in some applications and should be considered as a system design parameter.
GDT techniques employed for lightning or EMP protection
have a finite life span once activated. When measured, this is
found to be inversely proportional to the level of energy dissipated by the device. In tests, the GDT devices will withstand
multiple impulses of 20kA but only a single impulse of 50kA.
It is important to note that once failure occurs, the device
remains a short circuit to guarantee continued protection. To
facilitate the maintenance and reduce the expense of GDT
based systems, M/A-COM has designed these devices to be
field replaceable. Replacement GDT capsules are available
for field installation after a subsequent lightning or EMP strike.
Surge protectors have been specifically designed with fullyretained sealed covers which are located in an accessible
location to facilitate maintenance. GDT capsules require only
a standard wrench for field replacement.
Surge protectors are plated standard with M/A-COM’s specialized White Bronze™ finish, specially formulated to provide corrosion resistance in potentially aggressive physical environments. White Bronze™ plating is ideal for wireless applications
due to its excellent conductivity, and non-ferrous composition
for low intermodulation characteristics. Detailed application
notes are available for proper selection of lightning protection
devices (surge protectors & stub tuners) as well as intermodulation and White Bronze™ plating. Please refer to the application section at the back of this data sheet for more details on
availability of these application notes.
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
8
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific:
Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Specifications
Surge Protectors
Requirement
Detail
Electrical
Frequency Range
Impedance
VSWR Performance
Insertion Loss (Typical)
Impulse Discharge Current (8/20µs, multiple strike)
Maximum Impulse Discharge Current (8/20µs, single strike)
Dynamic Sparkover Voltage, NEMP (1kV/µs)
Dynamic Sparkover Voltage, LEMP (1kV/µs)
Dynamic Sparkover Voltage, Static (<100V/µs)
DC to 2.5GHz
50Ω
≤1.2:1
0.2dB
20kA
50kA
2,000V
800V
230V
Materials
Body Parts
Gaskets
Female Contacts
Male Contacts
Insulators
Brass
Silicone Rubber
Beryllium Copper
Brass
P.T.F.E.
Environmental
Operating Temperature Range
Relative Humidity
-45° C to +85° C
up to 100%
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
North America:
9
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific: Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Surge Protector – Product Offering
Surge Protectors
Type-N Jack to SMA Bulkhead Jack Adapter
53.8
REF
2.12
MAX PANEL
THICKNESS
Part Number
25.4
SQ
1.00
21.5 REF
.85
10.0
.39
13.5
.53 ACROSS
FLATS
TYPE N
JACK
13.6
.54
Frequency Range
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
ACROSS
FLATS
SMA JACK
16.0 DIA
.63
.250-36 UNS
RECOMMENDED
MOUNTING HOLE
19.0
HEX NUT
.750
.625-24 UNEF
GASKET
Type-N Bulkhead Jack to
Type N Bulkhead Jack Adapter
Part Number
53.8
REF
2.12
21.5
REF
.85
7.7
MAX PANEL
THICKNESS
.30
25.4
1.00 SQ
13.5 ACROSS
.53 FLATS
TYPE N
JACK
15.2
REF
.60
13.6
.54
ACROSS
FLATS
16.0 DIA
.63
.625-24 UNEF
(2 PLACES)
19.0
HEX NUT
.750
LOCKWASHER
COPPER WASHER
21.9
.86
REF
DC to 2.5GHz
Gold
White Bronze™
10,00mm
CECC22210/CEC22110
0.7-1.1Nm
1.7Nm both ends
500 Matings
14.0
.55
ACROSS
FLATS
LOCKWASHER
TYPE N JACK
A55X01B999X
Frequency Range
Contact Plating
Body Plating
Max Panel
Compliant With
Coupling Torque
Proof Torque
Endurance
N15X10B999X
DC to 2.5 GHz
Gold
White Bronze™
10,00mm
CECC22210
0.7-1.1 Nm
1.7 Nm
500 Matings
RECOMMENDED
MOUNTING HOLE
7-16 Plug to 7-16 Jack Adapter
Part Number
31.9
1.25
ACROSS FLATS
56.5
REF
2.23
7/16 JACK
7/16 PLUG
34.0
DIA REF
1.34
Frequency Range
Contact Plating
Body Plating
Compliant With
Coupling Torque
Proof Torque
Endurance
D75X06B999X
DC to 2.5GHz
6,0mm ± 0,5 Silver
White Bronze™
CECC22190
25 - 30 Nm
35Nm
500 Matings
M29 X 1.5
25.4
SQUARE
1.00
Gas Discharge Tube Replacement
ST127893-98
d.c. Sparkover Voltage:
Impulse Sparkover Voltage:
(1kV/mS)
230V±46V
700V typ.
(900V max)
Glow Discharge Voltage:
Arc Discharge Voltage:
a.c. Discharge Current:
(1 sec, 50Hz)
Impulse Discharge Current:
(8/20mS waveform)
72V
10V
20A
20kA (50kA for
one strike)
Insulation Resistance (@100V): 10GW
Capacitance:
2pF
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
10
North America:
Part Number
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific:
Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Tools & Adapter
Crimping Tool
Part Number
G30040
Part Number
A55P23E999X
Between Series Adapters
Type N Plug to 7-16 Plug
48.6 REF
1.91
Contact Plating: 6.0mm ± 0.5 Silver
Body Plating:
White Bronze™
7/16
PLUG
TYPE N
PLUG
20.6
DIA REF
.81
34.0
DIA REF
1.34
22.0 ACROSS FLATS
.87
32.0 ACROSS FLATS
1.26
Type N Plug to Type N Plug
Part Number
N15P10E999X
Contact Plating: Gold
Body Plating:
White Bronze™
40.5
REF
1.59
TYPE N PLUG
20.6
DIA REF
.81
TYPE N
PLUG
Specifications Subject to Change Without Notice.
11
M/A-COM, Inc.
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific: Tel. +81 3 3263 8761
Fax +81 3 3263 8769
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Adapters
Between Series Adapters cont’d.
Type N Plug to 7-16 Jack
Part Number
Contact Plating: 0.6mm Silver
Body Plating:
White Bronze™
51.9
2.04 REF
7/16 JACK
A55P24E999X
TYPE N
PLUG
20.6
DIA REF
.81
M29 X 1.5
24.0
ACROSS FLATS
.94
22.0 ACROSS FLATS
.86
SMA to Type N
Part Number
31.7
1.25 REF
18.2
.72 REF
3082-2240-00
Contact Plating: Gold
Body Plating:
Gold
TYPE N PLUG
21.0
.83 DIA REF
SMA JACK
14.3
ACROSS FLATS
.53
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
12
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific:
Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Application Notes
Selecting an RF
Coaxial Lightning
Protection Device
Selecting the best form of RF coaxial lightning protection is critical for your
infrastructure applications. M/A-COM has developed an application note which
provides detailed technical information on surge protector and stub tuner lightning
protection products to assist in the understanding and specification of this technology.
Application note ID 2012, entitled “Lightning and EMP Protection Devices” is available
from your local M/A-COM Sales Office, authorized distributor or directly through our
Global Applications Engineering Group.
White Bronze™ Plating
M/A-COM’s unique Copper, Tin, Zinc alloy finish is a robust plating which is suitable
for applications requiring excellent levels of electrical performance and offers the
following attributes:
• High Corrosion Resistance
• Low Porosity
• Non-magnetic Finish
• Wear & Scratch Resistant
• Low RF Loses
• Excellent for intermodulation Sensitive Applications
Application Note ID 1014 entitled “White Bronze” is available from your local
M/A-COM Sales Office, authorized distributor or directly through our Global
Applications Engineering Group.
Intermodulation
Dissimilar metals, finishes and discontinuities within a coaxial structure give rise to
intermodulation products (IMP). This is of particular concern in applications such as
cellular base stations and antennas which require low levels of intermodulation.
M/A-COM RF coaxial lightning protection devices were designed with this phenomena in
mind and, as such, contain no ferrous or magnetic materials and utilize low porosity
White Bronze™ plating. Complete in-house capabilities exist for intermodulation testing.
Application note ID1018, entitled “Intermodulation in RF Coaxial Connectors” is
available from your local M/A-COM Sales Office, authorized distributor or directly
through Global Applications Engineering Group.
Cable Assemblies
M/A-COM can provide customers with a complete high volume interconnect solution
for cellular base stations. Our global capabilities to provide cable assemblies facilitates
lower cost implementation of lightning protection devices. Our vertically integrated
resources ensure consistent and reliable control over all critical processes from
machining and plating to completed assembly. Semi-automated cable trimming and
termination techniques are consistently applied to the manufacturing process to
support volume capacity and assure repeatable quality. Test capabilities exist for
standard electrical screening such as VSWR and insertion loss as well as specialized
testing for such parameters as intermodulation (IMP).
A wide range of standard cable assembly offerings are listed for reference within
previous sections of this data sheet. A global staff of Application Engineers are
available to assist in the proper specification of a cable assembly to suit your
application needs. M/A-COM’s extensive experience in the manufacture of coaxial
connectors and cable assemblies can provide cost effective, competitive advantage for
your business.
Specifications Subject to Change Without Notice.
13
M/A-COM, Inc.
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific: Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Application Notes
Recommended
Mounting Techniques
To ensure that proper, low level contact resistance is established between the LP device
and mounting wall, it is recommended that a minimum torque of 50 in/lbs / 5.65 n/m
be applied to tighten the connector mounting nut. A recommended minimum torque of
35 in/lbs / 3.95 n/m should also be applied for installation of replacement surge protector
capsules to ensure proper protection performance.
Surge Protector
Mounting Techniques
In order to ensure that resultant currents from lightning or EMP strikes do not interfere
with parallel transmission lines within protected electronic equipment, surge protector
devices must be installed with proper orientation. The surge protector side of the
device should be mounted in the unprotected side of the equipment while the
mounting nut is positioned internally in the protected area.
Lightning Protection
Planning
It is important when planning lightning protection, that the user can estimate the
potential number of direct strikes. This information may influence the type of device
selected or the requirement for routine maintenance checks. Significant attention must
be paid to the height of supporting structure as this, when related to the typical
number of thunderstorms in a particular region, allows us to estimate the probability of
a direct strike taking place. To assist our customers in this, the following table and
chart has been included in this note. This should enable lightning protection planners
to establish the likelihood of direct strikes across a network anywhere in the world.
Selecting your RF
Coaxial Lightning
Protection Device
Number of Thunderstorm
Days per year
hmax/m
10%
hmax/m
20%
hmax/m
50%
05
10
15
20
30
40
50
70
90
130
150
180
28
18
14
12
9.4
7.9
6.9
5.6
4.8
3.9
3.5
3.1
39
26
20
17
13
11
9.5
8.0
7.0
5.5
5.0
4.4
61
40
31
26
20
17
15
12
10.6
8.5
7.7
6.9
Table 1: Maximum height of supporting building for a given number of thunderstorm days (when
hmax is exceeded, probability of direct strike to supporting building within 15 years is greater than
10% for hmax values given in second column, 20% for hmax values given in third column and
50% for hmax values given in the fourth column).
Specifications Subject to Change Without Notice.
M/A-COM, Inc.
14
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific: Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
RF Coaxial Lightning
& EMP Protection
Application Notes
World Map of Number
of Thunderstorm Days
Per Year/Per Region
Specifications Subject to Change Without Notice.
15
M/A-COM, Inc.
North America:
Tel. (800) 366-2266
Fax (800) 618-8883
■
Asia/Pacific: Tel. +85 2 2111 8088
Fax +85 2 2111 8087
■
Europe: Tel. +44 (1344) 869 595
Fax +44 (1344) 300 020
Sales Offices / Representatives
AMERICAS Tel: 800-366-2266
Fax: 800-618-8883
Argentina
54.1.300.2013
Chicago
800.366.2266
Los Angeles
800.366.2266
San Jose
800.366.2266
Atlanta
800.366.2266
Dallas
800.366.2266
New York, Metro
800.366.2266
Seattle
800.366.2266
Baltimore
800.366.2266
Dayton
800.366.2266
Orange County
800.366.2266
St. Louis
800.366.2266
Boston
800.366.2266
Denver
800.366.2266
Philadelphia
800.366.2266
Brazil
55.11.882.4000
Florida
800.366.2266
Phoenix
800.366.2266
Canada
800.366.2266
Fort Wayne
800.366.2266
Raleigh/Durham
800.366.2266
Cedar Rapids
800.366.2266
Kansas City
800.366.2266
San Diego
800.366.2266
EUROPE/MIDDLE EAST/AFRICA
Finland
358.95123.4237
France
33.1.3465.3737
Germany
49.89.462.3410
Hungary
Tavkozlest Innovations Co.
36.1.251.0888
ASIA/PACIFIC
Tel: 44.1344.869.595 Fax: 44.1344.300.020
India
RADELCOM
91.80.558.5999
Netherlands
Hi-Tech Electronic Components BV.
31.346566024
Switzerland
Walter-Electronic A.G.
41.71.969.4343
Israel
M/A-COM ISCOM LTD.
972.3.7518421
Poland
Micro Active Components SC
48.22.659.6174
Turkey
ELEKTRO Sanayi Ve Ticaret AS
90.216.4610700
Italy (Milan)
39.2.6696368
South Africa
DS Communications cc
27.11.805.1878
United Kingdom
M/A-COM European Hdq
44.1344.869.595
Italy (Rome)
39.6.4191955
Sweden
468.580.83385
Tel: 85.2.2111.8088 Fax: 85.2.2111.8087
China
Wellink Communications
852.2884.4128
Japan (Osaka)
NIHON M/A-COM, K.K.
81.6.423.4351
Hong Kong
MA/-COM Asia Pacific Hdq
85.2.2111.8088
Japan (Tokyo)
NIHON M/A-COM, K.K.
81.3.3263.8761
Hong Kong
Gentech Industries, Ltd.
852.2521.4567
Korea
Hanaro Corporation
82.2.516.1144
New Zealand (AMP)
64.9.634.4580
Shanghai PRC
Shanghai Well Genius
Optical Communications
Equip. Ltd.
86.21.6438.1888
Singapore
Excel-Max Communications
65.243.3266
Taiwan
Evergo Corporation
886.2.715.0283
Many M/A-COM products are available through distribution.
For a complete, worldwide list of M/A-COM distributors by return fax, call our FaxFacts System
from your fax machine at 978.442.4222 and request document 4,
or visit our Website at www.macom.com.
© 1997 M/A-COM, Inc.