HPN Home Phoneline Module 6649 The 6649 is designed to Support TUT Systems’ Home Run 1M8 Technology. • Withstands 235 ˚C peak infrared reflow temperature. • Includes protection circuitry, Isolation and EMI filtering. MECHANICAL 1.005 0.135 0.500 ± 0.015 0.370 Recommended Footprint 6649 YYWW 7x 0.100 0.700 7x 0.100 0.700 10 TIP (+) 1 0.500 ± 0.015 BAND PASS FILTER 0.267 ± 0.005 (+) 2 0.008 ± 0.004 0.039 TYP GND 3 0.020 x 0.010 ± 0.002 (16 places) Impedance: . . . . . . . . . . . . . . . . . . . . . . . . . . .100 ohms Insertion loss : 6 Mhz to 9 Mhz . . . . . . . . . . . . . . .< 4 dB Attenuation @ 1 MHz: . . . . . . . . . . . . . . . . . . . . .> 50 dB @ 27 Mhz: . . . . . . . . . . . . . . . . . . . . . .> 60 dB Return Loss : 6 mHz to 9 Mhz . . . . . . . . . . . .14 dB avg. Dielectric Test : Pins (1-2) to (10-9) . . . . . . . .2000 Vrms. ISSUE: 00/07/11 6649 ELECTRICAL SPECIFICATION An ISO 9001 Registered Company 229 Colonnade Road, Nepean, Ontario, Canada K2E 7K3 Tel: (613) 226-1626 Fax: (613) 226-7124 www.filtran.com 9 RING