FILTRAN 6649

HPN
Home Phoneline Module
6649
The 6649 is designed to Support TUT Systems’ Home Run 1M8 Technology.
• Withstands 235 ˚C peak infrared reflow
temperature.
• Includes protection circuitry, Isolation
and EMI filtering.
MECHANICAL
1.005
0.135
0.500 ± 0.015
0.370
Recommended Footprint
6649
YYWW
7x 0.100
0.700
7x 0.100
0.700
10 TIP
(+) 1
0.500 ± 0.015
BAND
PASS
FILTER
0.267 ± 0.005
(+) 2
0.008 ± 0.004
0.039 TYP
GND 3
0.020 x 0.010 ± 0.002
(16 places)
Impedance: . . . . . . . . . . . . . . . . . . . . . . . . . . .100 ohms
Insertion loss : 6 Mhz to 9 Mhz . . . . . . . . . . . . . . .< 4 dB
Attenuation @ 1 MHz: . . . . . . . . . . . . . . . . . . . . .> 50 dB
@ 27 Mhz: . . . . . . . . . . . . . . . . . . . . . .> 60 dB
Return Loss : 6 mHz to 9 Mhz . . . . . . . . . . . .14 dB avg.
Dielectric Test : Pins (1-2) to (10-9) . . . . . . . .2000 Vrms.
ISSUE: 00/07/11
6649
ELECTRICAL SPECIFICATION
An ISO 9001 Registered Company
229 Colonnade Road, Nepean, Ontario, Canada K2E 7K3
Tel: (613) 226-1626 Fax: (613) 226-7124 www.filtran.com
9 RING