TOKO 919AS-6R4M

Fixed Inductors for Surface Mounting
づ
け
面実装用 固定インダクタ
D10F
Inductance Range: 10~1500µH
Recommended patterns
DIMENSIONS/外形寸法図
推奨パターン図
12.0
9.7 Max.
2.8
5.0 Max.
8.6
1.0
方向表示
Direction indication
2.3 1.7
1.7 2.3
9.0
11.5 Max.
1.05
(Unit: mm)
(Unit: mm)
FEATURES/特長
• Low profile (9.7×11.5mm Max. square and 5.0mm Max.
height).
• Suitable for large current.
• Ideal for CCFL driving inverter circuit applications.
• RoHS compliant.
•
•
•
•
薄形構造(9.7×11.5mm 角Max.、高さ5.0mm Max.)
大電流対応
各種機器の冷陰極管駆動回路用
RoHS指令対応
SELECTION GUIDE FOR STANDARD COILS
TYPE D10F (Quantity/reel; 500 PCS)
東光品番
インダクタンス(1)
許容差
直流抵抗(2)
最大許容電流(3)
TOKO
Part
Number
Inductance(1)
L (µH)
Tolerance
(%)
DC Resistance(2)
(Ω) Max.
Rated
DC Current(3)
(A) Max.
#A814AY-100M
#A814AY-120M
#A814AY-150M
#A814AY-180M
#A814AY-220M
#A814AY-270M
#A814AY-330M
#A814AY-390M
#A814AY-470K
#A814AY-560K
#A814AY-680K
#A814AY-820K
#A814AY-101K
#A814AY-121K
#A814AY-151K
#A814AY-181K
#A814AY-221K
#A814AY-271K
#A814AY-331K
#A814AY-391K
#A814AY-471K
#A814AY-561K
#A814AY-681K
#A814AY-821K
#A814AY-102K
#A814AY-122K
#A814AY-152K
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
470
560
680
820
1000
1200
1500
(1) Inductance is measured with a LCR meter 4284A (Agilent Technologies)
or equivalent.
Test frequency at 100kHz
(2) DC resistance is measured with a Digital Multimeter TR6871 (Advantest)
or equivalent.
(3) Maximum allowable DC current is that which causes a 10% inductance
reduction from the initial value, or coil temperature to rise by 40°C
whichever is smaller.(Reference ambient temperature: 20°C)
± 20
± 20
± 20
± 20
± 20
± 20
± 20
± 20
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
± 10
0.047
0.050
0.058
0.067
0.075
0.087
0.095
0.120
0.150
0.180
0.200
0.230
0.270
0.330
0.400
0.530
0.600
0.840
1.000
1.090
1.250
1.630
1.900
2.440
2.800
3.670
4.370
2.60
2.48
2.27
2.15
2.00
1.84
1.72
1.58
1.44
1.28
1.20
1.09
1.05
0.92
0.80
0.73
0.69
0.60
0.53
0.49
0.46
0.41
0.38
0.34
0.31
0.27
0.25
(1) インダクタンスはLCRメータ4284A(Agilent Technologies)または同等品により測
定する。
測定周波数は100kHzです。
(2) 直流抵抗はデジタルマルチメータTR6871(Advantest)または同等品により測定する。
(3) 最大許容電流は、直流重畳電流を流した時インダクタンスの値が初期値より10%減
少する直流電流値、または直流電流により、コイルの温度が40℃上昇の何れか小さ
い値です。(周囲温度20℃を基準とする。
)