HW HWS421

HWS421
GaAs DC-2.0 GHz SPDT High Power Switch
September 2006
V2
SOT-26
Features
• Low Insertion Loss : 0.40 dB @ 0.9 GHz
• High Isolation: 28 dB @ 0.9 GHz
• Harmonics: <-65 dBc
• Low DC Power Consumption
• Low Cost SOT-26 Plastic Lead (Pb) Free
Package
• Lead Free and RoHS Compliant Version of
HWS341
Description
The HWS421 is a GaAs MMIC SPDT high power
switch in a low cost SOT-26 plastic lead (Pb) free
package. The HWS421 features low insertion loss
with very low DC power consumption. This high
power switch can be used in GSM and PCS
systems as selection of transmit or receive function
for a common antenna.
Electrical Specifications at 25°C with 0, +3V Control Voltages
Parameter
Test Conditions
Min.
Typ.
Max.
Unit
0.40
0.50
0.60
0.70
dB
dB
Insertion Loss
DC-1.0 GHz
DC-2.0 GHz
Isolation
DC-1.0 GHz
DC-2.0 GHz
VSWR
DC-2.0 GHz
1.20:1
Input Power for One dB Compression
0.5-2.0 GHz
38
dBm
34 dBm @1 GHz
70
dBc
200
ns
nd
rd
2 & 3 Harmonics
Switching Time
Control Current
25
19
dB
dB
27.5
21.5
100
Note: All measurements made in a 50 ohm system with 0/+3.0V control voltages, unless otherwise specified.
Hexawave Inc.
2 Prosperity Road II, Science Park, Hsinchu, Taiwan. TEL 886-3-578-5100 FAX 886-3-577-0512
http://www.hw.com.tw
All specifications are subject to change without notice.
uA
HWS421
GaAs DC-2.0 GHz SPDT High Power Switch
September 2006
V2
Typical Performance Data @ +25°C
Insertion Loss vs Frequency
Harmonic Rejection @ 34 dBm, 1 GHz
85
Harmonic Rejection (dBc)
Insertion Loss(dB)
0.0
-0.2
-0.4
-0.6
-0.8
-1.0
80
2nd Harmonic
75
70
3rd Harmonic
65
60
0.5
1.0
1.5
2.0
Frequency(GHz)
2.5
3.0
Isolation vs Frequency
2.5
3.0
3.5
Control Voltage (Volt)
4.0
Absolute Maximum Ratings
-10
Parameter
Absolute Maximum
Isolation(dB)
-15
-20
RF Input Power
0.5-2.5 GHz
+38 dBm
-25
Control Voltage
+6V
-30
Operating Temperature
-40°C to +85°C
-35
Storage Temperature
-65°C to +150°C
-40
Pin Out (Top View)
0.5
1.0
1.5
2.0
Frequency(GHz)
2.5
3.0
CB
RF2
Return Loss vs Frequency
GND
CA
1
6
2
5
VC2
RFC
-10
CB
Return Loss(dB)
3
RF1
-15
4
VC1
CA
CB
-20
-25
DC blocking capacitors CB are required on all RF ports.
CB=CA=51pF for operating frequency > 500MHz.
-30
Logic Table for Switch On-Path
-35
VC1
VC2
RFC-RF1
RFC-RF2
-40
1
0
Insertion Loss
Isolation
0
1
Isolation
Insertion Loss
0.5
1.0
1.5
2.0
Frequency(GHz)
2.5
3.0
‘1’ = +3V to +5V
‘0’ = 0V to +0.2V
Hexawave Inc.
2 Prosperity Road II, Science Park, Hsinchu, Taiwan. TEL 886-3-578-5100 FAX 886-3-577-0512
http://www.hw.com.tw
All specifications are subject to change without notice.