MA-COM EKIN2-10D

E-Series I/Q Demodulator
9 – 11 MHz
EKIN2-10D
V2
Features
•
•
•
•
SM - 28 Package
Excellent Phase and Amplitude Balance
LO Power + 10 dBm Typical
Surface Mount
Tape and reel packaging available
Description
M/A-COM’s EKIN2-10D is an I/Q Demodulator. Ideally suited for Direct Demodulation in Cellular Base
Stations. Typical system applications include GSM,
DCS1800, W-CDMA, and PCS air interfaces.Parts
are packaged in tape & reel.
Electrical Specifications: TA = 25°C, Z0 = 50Ω
∗
Parameter
Test Conditions
Frequency
Units
Min
Typ
Max
LO & RF Frequency
—
9 - 11
MHz
—
—
—
Amplitude Unbalance
—
9 - 11
dB
—
0.2
0.4
Phase Unbalance
—
9 - 11
Degrees
—
1.5°
3°
3 * I/Q
—
9 - 11
dB
—
50
35
Conversion Loss
—
9 - 11
dB
—
6.0
7.0
(LO) Carrier Power
—
9 - 11
dBm
—
+10
—
LO VSWR
—
9 - 11
Ratio
—
4.5:1
—
RF VSWR
—
9 - 11
Ratio
—
1.1:1
—
I VSWR
—
9 - 11
Ratio
—
1.3:1
—
Q = -90° for RF < LO
Ordering Information
Part Number
Package
EKIN2-10DTR
Tape and Reel (300 piece Reel)
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
E-Series I/Q Demodulator
9 – 11 MHz
EKIN2-10D
V2
Absolute Maximum Ratings 1
Pin Configuration
Parameter
Absolute Maximum
Pin No.
Function
DC Offset Voltage
1 mV Typical
1
LO
RF Power (1 dB Compression)
4 dBm Maximum
2
Case Ground
Impedance
50 Ohms Nominal
3
Case Ground
Operating Temperature
-40°C to +85°C
4
Case Ground
Storage Temperature
-55°C to +125°C
5
I
6
Q
7
Case Ground
8
RF
1. Operation of this device above any one of these parameters
may cause permanent damage.
Typical Performance Curves
Phase Unbalance
Amplitude Unbalance
LO VSWR
RF VSWR
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
E-Series I/Q Demodulator
9 – 11 MHz
EKIN2-10D
V2
Typical Performance Curves
I VSWR
Q VSWR
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.