PDI R0605400L

Product Specification
R0605400L
Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC
FEATURES
•
•
•
•
•
•
Excellent linearity
Superior return loss performance
Extremely low distortion
Optimal reliability
Low noise
Unconditionally stable under all terminations
R0605400L
APPLICATION
•
5 to 65 MHz CATV amplifier
for reverse channel systems
DESCRIPTION
•
Hybrid reverse amplifier employing silicon die
Si Reverse Hybrid, low current
5 – 65 MHz
40.3dB typ. Gain @ 65MHz
160mA max. @ 24VDC
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134)
SYMBOL
PARAMETER
Vi
Vov
Tstg
Tmb
RF input voltage (single tone)
DC supply over-voltage (5 minutes)
storage temperature
operating mounting base temperature
MIN.
MAX.
UNIT
- 40
- 30
50
30
+ 100
+ 100
dBmV
V
°C
°C
CHARACTERISTICS
Table 1: S-Parameter, Noise Figure, DC Current; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω
SYMBOL
PARAMETER
Gp
power gain
SL
FL
slope 1)
flatness of frequency
response
input return loss
output return loss
reverse isolation
noise figure
total current
consumption (DC)
S11
S22
S12
F
Itot
CONDITIONS
MIN.
TYP.
MAX.
UNIT
f = 5 MHz
f = 65 MHz
f = 5 to 65 MHz
f = 5 to 65 MHz
39.7
40.0
-0.1
-0.2
40.1
40.3
0.2
40.5
40.7
0.6
0.4
dB
dB
dB
dB
f = 5 to 65 MHz
f = 5 to 65 MHz
f = 5 to 65 MHz
f = 5 to 65 MHz
20.0
20.0
-
-40.0
4.5
160.0
dB
dB
dB
dB
mA
145.0
Notes:
1) The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency.
Page 1 of 4
2005 Nov 16
Document Revision Level B
Product Specification
R0605400L
Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC
CHARACTERISTICS
Table 2: Distortion data 5 – 65 MHz; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω
SYMBOL
PARAMETER
CONDITION
MIN.
1)
TYP.
MAX.
UNIT
-
- 72
dBc
CTB
composite triple beat
7 ch. flat; Vo = 50 dBmV
XMOD
cross modulation
7 ch. flat; Vo = 50 dBmV 1)
-
- 64
dB
CSO
composite second order
distortion
7 ch. flat; Vo = 50 dBmV 1)
-
- 70
dBc
d2
second order distortion
2)
- 70
dBc
output voltage
3)
-
dBmV
V0
Notes:
1)
2)
3)
Dim = -60 dB
62.0
7 channels, US frequency raster: T7 – T13 (7.0 to 43.0 MHz), +50 dBmV flat output level.
f1 = 7.00 MHz; V1 = 50 dBmV; f2 = 25.00 MHz; V2 = 50 dBmV; fTEST = f1 + f2 = 32.0 MHz.
f1 = 13.00 MHz; V1 = 50 dBmV; f2 = 25.00 MHz; V2 = V1 – 6dB; f3 = 7.00 MHz; V3 = V1 – 6dB;
fTEST = f1 + f2 - f3 = 31.00 MHz, according to DIN45004B.
Composite Second Order (CSO)
The CSO parameter (both sum and difference products) is defined by the NCTA.
Composite Triple Beat (CTB)
The CTB parameter is defined by the NCTA.
Cross Modulation (XMOD)
Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the
carrier being tested.
Page 2 of 4
2005 Nov 16
Document Revision Level B
Product Specification
R0605400L
Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC
I
U
123 5 7 89
C
E
J
S
P
R
M
K
O
T
Q
øG
N
D
B
H
L
All Dimensions in mm:
F
A
Pinning:
5 10mm
2
3 4 5 6 7
8
Notes:
Page 3 of 4
GND
GND
+VB
GND
GND
INPUT
scale
9
OUTPUT
0
1
European
Projection
2005 Nov 16
nominal
min
A
44,6 ± 0,2
44,4
max
44,8
B
13,6 ± 0,2
13,4
13,8
C
20,4 ± 0,5
19,9
20,9
D
8 ± 0,15
7,85
8,15
E
12,6 ± 0,15
12,45
12,75
F
38,1 ± 0,2
37,9
38,3
G
4 +0,2 / -0,05
3,95
4,2
H
4 ± 0,2
3,8
4,2
I
25,4 ± 0,2
25,2
25,6
J
UNC 6-32
-
-
K
4,2 ± 0,2
4,0
4,4
L
27,2 ± 0,2
27,0
27,4
M
11,6 ± 0,5
11,1
12,1
N
5,8 ± 0,4
5,4
6,2
O
0,25 ± 0,02
0,23
0,27
0,48
P
0,45 ± 0,03
0,42
Q
2,54 ± 0,3
2,24
2,84
R
2,54 ± 0,5
2,04
3,04
S
2,54 ± 0,25
2,29
2,79
T
5,08 ± 0,25
4,83
5,33
U
5,08 ± 0,25
4,83
5,33
Document Revision Level B
Product Specification
R0605400L
Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC
DEFINITIONS
Data Sheet Status
Objective Product
Specification
Preliminary Product
Specification
Product Specification
This data sheet contains target or goal specifications for product
development.
This data sheet contains preliminary data; supplementary data may
be published later.
This data sheet contains final product specifications.
Limiting values
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 60134).
Stress above one or more of the limiting values may cause permanent damage to the device.
These are stress ratings only and operation of the device at these or at any other conditions
above those given in the Characteristics sections of the specification is not implied. Exposure to
limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
Premier Devices reserves the right to make changes without further notice to any products herein.
Premier Devices makes no warranty representation or guarantee regarding the suitability of its products for any particular
purpose, nor does Premier Devices assume any liability arising out of the application or use of any product or circuit, and
specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical”
parameters which may be provided in Premier Devices datasheets and/or specifications can and do vary in different
applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated
for each customer application by customer´s technical experts. Premier Devices does not convey any license under its
patent rights nor the rights of others. Premier Devices products are not designed, intended, or authorized for use as
components in systems intended for surgical implant into the body, or other applications intended to support or sustain
life, or for any other application in which the failure of the Premier Devices product could create a situation where personal
injury or death may occur. Should Buyer purchase or use Premier Devices products for any such unintended or
unauthorized application, Buyer shall indemnify and hold Premier Devices and its officers, employees, subsidiaries,
affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees
arising out of, directly or indirectly, and claim of personal injury or death associated with such unintended or unauthorized
use, even if such claim alleges that Premier Devices was negligent regarding the design or manufacture of the part.
© Premier Devices Germany GmbH 2004
How to contact us:
Premier Devices Germany GmbH
Loeffelholzstrasse 20, D-90441 Nuernberg, Germany
Phone: +49 (0) 911 9411 233, FAX: +49 (0) 911 9411 198,
Email: [email protected], Internet: http://www.premierdevices.de/
Page 4 of 4
2005 Nov 16
Document Revision Level B