Product Specification R0605400L Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC FEATURES • • • • • • Excellent linearity Superior return loss performance Extremely low distortion Optimal reliability Low noise Unconditionally stable under all terminations R0605400L APPLICATION • 5 to 65 MHz CATV amplifier for reverse channel systems DESCRIPTION • Hybrid reverse amplifier employing silicon die Si Reverse Hybrid, low current 5 – 65 MHz 40.3dB typ. Gain @ 65MHz 160mA max. @ 24VDC LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 60134) SYMBOL PARAMETER Vi Vov Tstg Tmb RF input voltage (single tone) DC supply over-voltage (5 minutes) storage temperature operating mounting base temperature MIN. MAX. UNIT - 40 - 30 50 30 + 100 + 100 dBmV V °C °C CHARACTERISTICS Table 1: S-Parameter, Noise Figure, DC Current; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω SYMBOL PARAMETER Gp power gain SL FL slope 1) flatness of frequency response input return loss output return loss reverse isolation noise figure total current consumption (DC) S11 S22 S12 F Itot CONDITIONS MIN. TYP. MAX. UNIT f = 5 MHz f = 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz 39.7 40.0 -0.1 -0.2 40.1 40.3 0.2 40.5 40.7 0.6 0.4 dB dB dB dB f = 5 to 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz f = 5 to 65 MHz 20.0 20.0 - -40.0 4.5 160.0 dB dB dB dB mA 145.0 Notes: 1) The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency. Page 1 of 4 2005 Nov 16 Document Revision Level B Product Specification R0605400L Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC CHARACTERISTICS Table 2: Distortion data 5 – 65 MHz; VB = 24V; Tmb = 30°C; ZS = ZL = 75 Ω SYMBOL PARAMETER CONDITION MIN. 1) TYP. MAX. UNIT - - 72 dBc CTB composite triple beat 7 ch. flat; Vo = 50 dBmV XMOD cross modulation 7 ch. flat; Vo = 50 dBmV 1) - - 64 dB CSO composite second order distortion 7 ch. flat; Vo = 50 dBmV 1) - - 70 dBc d2 second order distortion 2) - 70 dBc output voltage 3) - dBmV V0 Notes: 1) 2) 3) Dim = -60 dB 62.0 7 channels, US frequency raster: T7 – T13 (7.0 to 43.0 MHz), +50 dBmV flat output level. f1 = 7.00 MHz; V1 = 50 dBmV; f2 = 25.00 MHz; V2 = 50 dBmV; fTEST = f1 + f2 = 32.0 MHz. f1 = 13.00 MHz; V1 = 50 dBmV; f2 = 25.00 MHz; V2 = V1 – 6dB; f3 = 7.00 MHz; V3 = V1 – 6dB; fTEST = f1 + f2 - f3 = 31.00 MHz, according to DIN45004B. Composite Second Order (CSO) The CSO parameter (both sum and difference products) is defined by the NCTA. Composite Triple Beat (CTB) The CTB parameter is defined by the NCTA. Cross Modulation (XMOD) Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the carrier being tested. Page 2 of 4 2005 Nov 16 Document Revision Level B Product Specification R0605400L Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC I U 123 5 7 89 C E J S P R M K O T Q øG N D B H L All Dimensions in mm: F A Pinning: 5 10mm 2 3 4 5 6 7 8 Notes: Page 3 of 4 GND GND +VB GND GND INPUT scale 9 OUTPUT 0 1 European Projection 2005 Nov 16 nominal min A 44,6 ± 0,2 44,4 max 44,8 B 13,6 ± 0,2 13,4 13,8 C 20,4 ± 0,5 19,9 20,9 D 8 ± 0,15 7,85 8,15 E 12,6 ± 0,15 12,45 12,75 F 38,1 ± 0,2 37,9 38,3 G 4 +0,2 / -0,05 3,95 4,2 H 4 ± 0,2 3,8 4,2 I 25,4 ± 0,2 25,2 25,6 J UNC 6-32 - - K 4,2 ± 0,2 4,0 4,4 L 27,2 ± 0,2 27,0 27,4 M 11,6 ± 0,5 11,1 12,1 N 5,8 ± 0,4 5,4 6,2 O 0,25 ± 0,02 0,23 0,27 0,48 P 0,45 ± 0,03 0,42 Q 2,54 ± 0,3 2,24 2,84 R 2,54 ± 0,5 2,04 3,04 S 2,54 ± 0,25 2,29 2,79 T 5,08 ± 0,25 4,83 5,33 U 5,08 ± 0,25 4,83 5,33 Document Revision Level B Product Specification R0605400L Si Reverse, low current, 5 – 65MHz, 40.3dB typ. Gain @ 65MHz, 160mA max. @ 24VDC DEFINITIONS Data Sheet Status Objective Product Specification Preliminary Product Specification Product Specification This data sheet contains target or goal specifications for product development. This data sheet contains preliminary data; supplementary data may be published later. This data sheet contains final product specifications. Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 60134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification. Premier Devices reserves the right to make changes without further notice to any products herein. Premier Devices makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose, nor does Premier Devices assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters which may be provided in Premier Devices datasheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer´s technical experts. Premier Devices does not convey any license under its patent rights nor the rights of others. Premier Devices products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the Premier Devices product could create a situation where personal injury or death may occur. Should Buyer purchase or use Premier Devices products for any such unintended or unauthorized application, Buyer shall indemnify and hold Premier Devices and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, and claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Premier Devices was negligent regarding the design or manufacture of the part. © Premier Devices Germany GmbH 2004 How to contact us: Premier Devices Germany GmbH Loeffelholzstrasse 20, D-90441 Nuernberg, Germany Phone: +49 (0) 911 9411 233, FAX: +49 (0) 911 9411 198, Email: [email protected], Internet: http://www.premierdevices.de/ Page 4 of 4 2005 Nov 16 Document Revision Level B