Series MX 2-Pole or 3-Pole 4A 460 Vac DIN-Rail SSR Part Number Description MX2P46D4T-02 4A, 460 Vac MX3P46D4S-02 4A, 460 Vac Part Number Explanation MX 46 2P D T 4 -02 FEATURES/BENEFITS • New generation of solid-state relays for DIN-rail mounting • Two- or three-pole output with single control • Tight zero-cross window for low EMI • Control visualization by LED • Integrated clamping voltage • High immunity to surges NOTES 1) Poles: 2P = 2 pole; 3P = 3 pole 2) Line Voltage: 46 = 460 Vac 3) Switch Type: D = Zero-cross turn-on 4) Control Range: T = 15–40 Vdc; S = 12–35 Vdc 5) Options: 02 = With LED MECHANICAL SPECIFICATION L3 L1 input output 6-30Vdc 400Vac 4A L2 A1+ 4- 3+ T1 T2 Input 24-460Vac 12-35Vdc 4A AC3 3.01 (76.4) L1 L2 A1+ A1- ±0.4 3.01 (76.4) ±0.4 2 1 L1 L2 T1 T2 A1- A2- A1+ T2 T3 input 10-35VDC T1 ±0.2 1.14 2.09 ±0.2 (29) ±0.1 .98 (25) (53) WEIGHT: 1.06 oz (30g) 1.87 MX2P46D4T-02 ±0.1 DESCRIPTION The Series MX relays are a new generation of solidstate relays for DIN-rail fixation. The MX relays are internally wired to provide a common control. The relays are placed on a single DIN-rail fixture, saving designers time and space. The Series MX relays provide a control status LED and internal output protection. (47.5) MX3P46D4S-02 Figure 1 — MX relays; dimensions in inches (mm) INPUT (CONTROL) SPECIFICATION Min Max Units MX2P46D4T-02 15 40 V MX3P46D4S-02 12 35 V MX2P46D4T-02 4.4 17 mA MX3P46D4S-02 7.5 30 mA APPLICATIONS • Interface applications • Vending machines • Light/lamp control • Contactor driver • Fan speed control • HVAC controls • Heating control Control Range Input Current Range BLOCK DIAGRAM A1 + A1 + Rc Must Turn-Off Voltage Rc L1 L1 T1 MX2P46D4T-02 8 V MX3P46D4S-02 6 V T1 L2 T2 L2 L3 Input Resistance (Typical) A1 - MX2P46D4T-02 2000 Ohms MX3P46D4S-02 1000 Ohms © 2003 TELEDYNE RELAYS T2 Figure 2a — MX2P relay (800) 284-7007 • www.teledynerelays.com A1 - T3 Figure 2b — MX3P relay MX 1 MX\032003\Q1 Series MX CONTROL CHARACTERISTICS OUTPUT (LOAD) SPECIFICATION Min 18 Input Current (mA) 16 Operating Range 14 24 Peak Voltage 12 Max Unit 460 Vrms 1200 V 4 Arms 2.5 Arms Load Current 10 8 Range (Resistive) .005 6 4 Inductive Load Current 2 Maximum Surge Current Rating (Non-Repetitive) 0 0 5 10 15 20 25 30 35 40 Control Voltage (V) Figure 3a — MX2P relay 30 (See Figure 5) 120 A On-State Voltage Drop 1.6 V Zero-Cross Window ±12 V Off-State Leakage Current (60Hz) 0.3 mA Turn-On Time (60Hz) 8.3 ms Turn-Off Time (60Hz) 8.3 ms Input Current (mA) 25 20 Off-State dv/dt 15 Operating Frequency 10 2 I t for match fusing (<8.3ms) 10 500 V/µs 440 Hz 50 A2S 5 ENVIRONMENTAL SPECIFICATION 0 0 5 10 15 20 25 30 35 Min Control Voltage (V) Figure 3b — MX3P relay TYPICAL APPLICATIONS Max Unit Operating Temperature –40 80 °C Storage Temperature –40 150 °C Input-Output Isolation 4000 Vrms Input-Output Capacity 3 pF 3 phases 200 up to 480 Vac L1 L2 L3 SURGE CURRENT Y wiring 150 ∆ wiring Apeak Non-Repetitive 100 50 Repetitive with initial Tj = 70°C 0 single phase 0.01 0.1 1 10 t(s) Figure 5 — MX relays Figure 4a — MX2P relay LOAD L1 L2 L3 Figure 4b — MX3P relay MX 2 NOTES: 1. Electrical parameters at 25°C unless otherwise specified. 2. For 800Hz applications, contact factory. 3. For additional/custom options, contact factory. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS MX\032003\Q1