MAXIM DS600_07

DS600
±0.5 Accurate Analog-Output
Temperature Sensor
www.maxim-ic.com
FEATURES
GENERAL DESCRIPTION
The DS600 is a ±0.5°C accurate analog-output
temperature sensor. This accuracy is valid over its
entire operating voltage range of 2.7V to 5.5V and
the wide temperature range of -20°C to +100°C. The
DS600 can also act as a thermostat, with userprogrammable trip points. A shutdown mode enables
the DS600 to be placed in a low-power standby state.
The DS600 is available in an 8-pin µSOP package.
ƒ
ƒ
APPLICATIONS
ƒ
Cold-Junction Thermocouple Compensation
Portable Medical Equipment
Thermally Sensitive Systems that Require a HighAccuracy Analog-Output Temperature Sensor
ƒ
ƒ
ƒ
ƒ
ƒ
ORDERING INFORMATION
PART
TYPICAL OPERATING CIRCUIT
2.7V to 5.5V
DS600
GND
TO
CTG
TO
VOUT
SD
VTH
TEMP RANGE
DS600U
-40°C to +125°C
DS600U+
-40°C to +125°C
DS600U/T&R
-40°C to +125°C
DS600U+/T&R
-40°C to +125°C
PIN-PACKAGE
Exposed Pad
8 µSOP
Exposed Pad
8 µSOP
Exposed Pad
8 µSOP
Tape-and-Reel
Exposed Pad
8 µSOP
Tape-and-Reel
+ Denotes lead-free package.
PAD
VDD
±0.5°C Accuracy (-20°C to +100°C)
±0.75°C Accuracy Over Entire Temperature
Range of -40°C to +125°C
Requires No External Components
6.45mV/°C Output Gain with 509mV Offset at
0°C
2.7V to 5.5V Supply Voltage Range
User-Programmable Thermostat Function
Shutdown Function Puts Device into a LowPower Standby Mode
Exposed Pad 8-Pin µSOP Package for Quick
Thermal Response
PIN CONFIGURATION
TOP VIEW
TO/FROM
µC
PAD
8-Pin μSOP Package
Exposed Pad
Note: Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisions of any device
may be simultaneously available through various sales channels. For information about device errata, click here: www.maxim-ic.com/errata.
1 of 5
REV: 041607
DS600 ±0.5°C Accurate Analog-Output Temperature Sensor
ABSOLUTE MAXIMUM RATINGS
Voltage Range on Any Pin (except CTG) Relative to Ground
Voltage Range on CTG Relative to Ground
Operating Temperature Range
Storage Temperature Range
Soldering Temperature (10s)
Reflow Oven Temperature
-0.5V to +6.0V
-0.5 to +0.5V
-40°C to +125°C
-55°C to +125°C
+260°C (See IPC/JEDEC J-STD-020A)
+220°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only,
and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is
not implied. Exposure to the absolute maximum rating conditions for extended periods may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
(VCC = 2.7V to 5.5V, TA = -40°C to +125°C.)
PARAMETER
Supply Voltage
Thermometer Error
Output Gain
VOUT DC Offset
SYMBOL
CONDITIONS
VDD
TERR
MIN
TYP
2.7
-20°C to +100°C
-40°C to +125°C
ΔV/ΔT
MAX
UNITS
5.5
±0.5
±0.75
V
6.45
mV/°C
Low-Level Input Voltage (SD)
High-Level Input Voltage (SD)
VOS
VIL
VIH
SD Input Capacitance
CSD
5
pF
VTH Input Capacitance
Low-Level Output Voltage
(TO, TO)
Supply Current
CVTH
5
pF
VOL
0°C
°C
509
-0.5
0.7 x VDD
4mA sink current
mV
0.3 x VDD
VDD + 0.5
0
V
V
0.4
V
IDD
140
µA
Shutdown Current
ISD
2.5
µA
Input Current (VTH)
ITH
1
µA
Input Resistance (VTH)
RTH
0.01
5
IL
MΩ
0.01
1
µA
50
pF
Leakage Current (SD)
External Load Capacitance
on VOUT
CEL
VOUT Source Current
IOSO
10
µA
VOUT Sink Current
Output Impedance (VOUT)
IOSI
ROUT
10
µA
Power-Up Time
tPOWERUP
Nonlinearity
Comparator Offset
Comparator Response Time
tCOMP
2 of 5
100
Ω
10
ms
±0.2
°C
±3
mV
20
ms
DS600 ±0.5°C Accurate Analog-Output Temperature Sensor
PIN DESCRIPTION
PIN
1
NAME
VDD
2
TO
3
TO
4
VOUT
5
VTH
6
SD
7
8
CTG
GND
PAD
FUNCTION
Supply Voltage. 2.7V to 5.5V
Active-High Thermostat Output. Open-drain output transitions from low to high when the output
voltage exceeds VTH. In shutdown mode, (SD = 1), TO is low.
Active-Low Thermostat Output. Open-drain output transitions from high to low when the output
voltage exceeds VTH. In shutdown mode, (SD = 1), TO is high.
Temperature Output. Outputs a voltage that is proportional to the die temperature in degrees
centigrade. In shutdown mode, this pin goes high-Z.
Thermostat Trip Voltage. User-selectable voltage that sets the thermostat trip-point temperature.
TO and TO are asserted when VOUT crosses this voltage. (No on-chip hysteresis is present).
Shutdown. Power consumption and thermal sensor function are controlled through SD. This pin
functions as an active-high input pin. Driving this pin high puts the device in a low-power state and
discontinues thermal sensing.
Must be connected to GND.
Ground.
PAD. Connect to GND or float. DO NOT CONNECT TO SUPPLY. The exposed pad is the best
way to conduct temperature into the package. Connecting PAD to a ground plane can assist in
properly measuring the temperature of the circuit board.
Figure 1. Block Diagram
2.7V to 5.5V
LEVEL-SHIFT
BUFFER
VDD
TEMPERATURE
SENSOR
VOUT
THERMOSTAT
COMPARATOR
DS600
TO
SD
CONTROL
LOGIC
TO
VTH
GND
TEMPERATURE MEASUREMENT
The DS600 analog temperature sensor measures it own temperature and provides these measurements to the
user in the form of an output voltage, VOUT, that is proportional to degrees centigrade. The output voltage
characteristic is factory-calibrated for a typical output gain (ΔV/ΔT) of +6.45mV/°C and a DC offset (VOS) of 509mV.
Its operating temperature range is -40°C to +125°C, corresponding to an output voltage range of 251mV to
1315mV. (VOUT = Device Temperature (°C) x ΔV/ΔT + VOS). The DS600 has ±0.5°C accuracy over a -20°C to
+100°C temperature range and over the full 2.7V to 5.5V voltage range. Because the output voltage is positive for
the entire temperature range, there is no need for a negative supply.
Figure 2 shows the output voltage characteristic for the DS600.
3 of 5
DS600 ±0.5°C Accurate Analog-Output Temperature Sensor
Figure 2. Output Voltage Characteristic
DS600 OUTPUT CHARACTERISTIC
1.4
VOUT (V)
1
0.6
509mV
0.2
-40 -20
0
20
40
60
80 100 120
TEMPERATURE (°C)
THERMOSTAT OPERATION
The DS600 can also be used as a thermostat with either an active-high (TO) or active-low (TO) output. To function
as a thermostat, a precise voltage reference equal to the desired threshold must be applied to the VTH pin. When
the temperature with the equivalent voltage value is reached (voltage on VOUT = voltage on VTH), thermostat outputs
TO and TO become active. Figure 3 shows an example thermostat application circuit.
Figure 3. Thermostat Application Circuit
2.7V to 5.5V
500 KΩ
DS600
PAD
VDD
GND
TO
CTG
TO
VOUT
SD
VTH
4 of 5
MAX6007A
DS600 ±0.5°C Accurate Analog-Output Temperature Sensor
PACKAGE INFORMATION
For the latest package outline information, go to www.maxim-ic.com/DallasPackInfo.
Maxim/Dallas Semiconductor cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim/Dallas Semiconductor product.
No circuit patent licenses are implied. Maxim/Dallas Semiconductor reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2007 Maxim Integrated Products • Printed USA
5 of 5