Transys 1N5829(R) THRU 1N6096(R) Electronics L I M I T E D SCHOTTKY DIODES STUD TYPE 25 A Features 25Amp Rectifier 20-40 Volts High Surge Capability Types up to 40V VRRM DO-4 B Maximum Ratings N Operating Temperature: -55 C to +150 Storage Temperature: -55 C to +175 M C J Part Number 1N5829( R ) 1N5830( R ) 1N6095( R ) 1N5831( R ) 1N6096( R ) Maximum Recurrent Peak Reverse Voltage 20V 25V 30V 35V 40V Electrical Characteristics @ 25 Average Forward Current Peak Forward Surge Current NOTE (1) Maximum Instantaneous Forward Voltage Maximum Instantaneous Reverse Current At Rated DC Blocking NOTE (1) Voltage Maximum thermal resistance, junction to case Mounting torque Maximum RMS Voltage Maximum DC Blocking Voltage 14V 17V 21V 25V 28V 20V 25V 30V 35V 40V 25A TC =100 IFSM 800A 400A (1N5829~1N5831) (1N6095~1N6096) 8.3ms, Half s i ne VF 0.58V IFM =25 A; TJ = 25 IR 2.0 mA 250 mA TJ = 25 TJ =125 R jc Kgf-cm G F 1.8 /W Not lubricated 11.0~13.4 threads NOTE : (1) Pulse Test: Pulse Width 300 usec, Duty Cycle < 2% E A Notes: 1.Standard Polarity:Stud is Cathode 2.Reverse Polarity:Stud is Anode Unless Otherwise Specified IF(AV) D P DIMENSIONS DIM A B C D E F G J M N P INCHES MIN MAX 10 ¼ -32 UNF3A .437 .424 .505 ----.600 .820 .422 .453 .075 .175 ----.405 .310 ----.413 ----.065 .020 .060 .100 MM MIN MAX NOTE Threads Standard Polarity 10.77 11.10 ----12.82 15.24 20.82 10.72 11.50 1.91 4.44 ----10.29 ----7.87 10.49 ----0.51 1.65 1.53 2.54 Transys Electronics 1N5829(R) THRU L I M I T E D Figure .2- Forward Derat ing Curve Figure .1-Typical Forward Characteristics 30 Average ForwArd Rectified Current - AmPeres 40 - 125 C 20 Amps I nStantaneous Forward Current Amperes 60 25 C 10 6.0 25 20 Amps 100 1N6096(R) 15 10 5 0 4.0 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 30 60 90 120 150 180 Case Te mperature - 2.0 1000 1.0 0 0.2 0.4 0.6 0.8 1.0 Figure .4- Typical Reverse Characteristics 600 1.2 400 Volts Instantaneous Forward Voltage - Volts 200 Tj =150 C 100 60 600 450 1N5829~1N5831 300 150 1N6095~1N6096 0 1 2 4 6 8 10 20 40 Cycles Number Of Cycles At 60Hz - Cycles 60 80 100 Tj =125 C 20 10 6 m Amps 8.3ms Single Half Sine Wave JEDEC method TJ =25 750 Amps Peak Forward Surge Current -Amperes 900 Figure .3- Peak Forward Surge Current Instantaneous Reverse Leakage Current - Mill Amperes 40 4 2 TJ =75 1 .6 .4 .2 .1 .06 .04 TJ =25 .02 .01 0 10 20 Volts Revers Voltage - Volts 30 40 50