TRSYS 1N6095R

Transys
1N5829(R)
THRU
1N6096(R)
Electronics
L I M I T E D
SCHOTTKY DIODES STUD TYPE
25 A
Features
25Amp Rectifier
20-40 Volts
High Surge Capability
Types up to 40V VRRM
DO-4
B
Maximum Ratings
N
Operating Temperature: -55 C to +150
Storage Temperature: -55 C to +175
M
C
J
Part Number
1N5829( R )
1N5830( R )
1N6095( R )
1N5831( R )
1N6096( R )
Maximum
Recurrent
Peak Reverse
Voltage
20V
25V
30V
35V
40V
Electrical Characteristics @ 25
Average Forward
Current
Peak Forward Surge
Current
NOTE (1)
Maximum
Instantaneous
Forward Voltage
Maximum
Instantaneous
Reverse Current At
Rated DC Blocking
NOTE (1)
Voltage
Maximum thermal
resistance,
junction to case
Mounting torque
Maximum
RMS Voltage
Maximum DC
Blocking
Voltage
14V
17V
21V
25V
28V
20V
25V
30V
35V
40V
25A
TC =100
IFSM
800A
400A
(1N5829~1N5831)
(1N6095~1N6096)
8.3ms, Half s i ne
VF
0.58V
IFM =25 A;
TJ = 25
IR
2.0 mA
250 mA
TJ = 25
TJ =125
R jc
Kgf-cm
G
F
1.8
/W
Not lubricated
11.0~13.4 threads
NOTE :
(1) Pulse Test: Pulse Width 300 usec, Duty Cycle < 2%
E
A
Notes:
1.Standard Polarity:Stud is Cathode
2.Reverse Polarity:Stud is Anode
Unless Otherwise Specified
IF(AV)
D
P
DIMENSIONS
DIM
A
B
C
D
E
F
G
J
M
N
P
INCHES
MIN
MAX
10
¼ -32 UNF3A
.437
.424
.505
----.600
.820
.422
.453
.075
.175
----.405
.310
----.413
----.065
.020
.060
.100
MM
MIN
MAX
NOTE
Threads
Standard Polarity
10.77
11.10
----12.82
15.24
20.82
10.72
11.50
1.91
4.44
----10.29
----7.87
10.49
----0.51
1.65
1.53
2.54
Transys
Electronics
1N5829(R) THRU
L I M I T E D
Figure .2- Forward Derat ing Curve
Figure .1-Typical Forward Characteristics
30
Average ForwArd Rectified Current - AmPeres
40
-
125 C
20
Amps
I nStantaneous Forward Current Amperes
60
25 C
10
6.0
25
20
Amps
100
1N6096(R)
15
10
5
0
4.0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
30
60
90
120
150
180
Case Te mperature -
2.0
1000
1.0
0
0.2
0.4
0.6
0.8
1.0
Figure .4- Typical Reverse Characteristics
600
1.2
400
Volts
Instantaneous Forward Voltage - Volts
200
Tj =150 C
100
60
600
450
1N5829~1N5831
300
150
1N6095~1N6096
0
1
2
4
6
8 10 20
40
Cycles
Number Of Cycles At 60Hz - Cycles
60 80 100
Tj =125 C
20
10
6
m Amps
8.3ms Single Half
Sine Wave
JEDEC method TJ =25
750
Amps
Peak Forward Surge Current -Amperes
900
Figure .3- Peak Forward Surge Current
Instantaneous Reverse Leakage Current - Mill Amperes
40
4
2
TJ =75
1
.6
.4
.2
.1
.06
.04
TJ =25
.02
.01
0
10
20
Volts
Revers Voltage - Volts
30
40
50