54ACT11011, 74ACT11011 TRIPLE 3-INPUT POSITIVE-AND GATES SCAS028A – D2957, JULY 1987 – REVISED APRIL 1993 • • • • Inputs Are TTL-Voltage Compatible Flow-Through Architecture Optimizes PCB Layout Center-Pin VCC and GND Configurations Minimize High-Speed Switching Noise EPIC t (Enhanced-Performance Implanted CMOS) 1-mm Process 500-mA Typical Latch-Up Immunity at 125°C Package Options Include Plastic Small-Outline Packages, Ceramic Chip Carriers, and Standard Plastic and Ceramic 300-mil DIPs 54ACT11011 . . . J PACKAGE 74ACT11011 . . . D OR N PACKAGE (TOP VIEW) 1A 1Y 2Y GND GND 3Y 3C 3B These devices contain three independent 3-input AND gates. They perform the Boolean functions Y = ASBSC or Y = A + B + C in positive logic. 1C 1B NC 1A 1Y FUNCTION TABLE (each gate) INPUTS A B C OUTPUT Y H H H H 1B 1C 2A 2B 2C 3A 3B 3C 3 14 4 13 5 12 6 11 7 10 8 9 1B 1C 2A VCC VCC 2B 2C 3A 4 3 2 1 20 19 18 5 17 6 16 7 15 8 14 9 10 11 12 13 2C 3A NC 3B 3C L X X L X L X L X X L L NC – No internal connection logic diagram (positive logic) logic symbol† 16 15 2Y GND NC GND 3Y The 54ACT11011 is characterized for operation over the full military temperature range of – 55°C to 125°C. The 74ACT11011 is characterized for operation from – 40°C to 85°C. 1A 16 2 54ACT11011 . . . FK PACKAGE (TOP VIEW) description 1 1 2A VCC NC VCC 3B • • & 2 15 1Y 1A 1B 1C 1Y 2A 2B 2C 2Y 3A 3B 3C 3Y 14 11 3 10 2Y 9 8 7 6 3Y † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for the D, J, and N packages. EPIC is a trademark of Texas Instruments Incorporated. Copyright 1993, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 2–1 54ACT11011, 74ACT11011 TRIPLE 3-INPUT POSITIVE-AND GATES SCAS028A – D2957, JULY 1987 – REVISED APRIL 1993 absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 100 mA Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed. recommended operating conditions 54ACT11011 MAX MIN MAX 4.5 5.5 4.5 5.5 VCC VIH Supply voltage VIL VI Low-level input voltage Input voltage 0 VO IOH Output voltage 0 IOL Dt /Dv Low-level output current TA Operating free-air temperature High-level input voltage 74ACT11011 MIN 2 2 0.8 High-level output current VCC VCC 0 0 – 24 24 Input transition rise or fall rate UNIT V V 0.8 V VCC VCC V – 24 mA V 24 mA 0 10 0 10 ns/ V – 55 125 – 40 85 °C electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS IOH = – 50 mA VOH IOH = – 24 mA IOH = – 50 mA} IOH = – 75 mA} TA = 25°C MIN TYP MAX 54ACT11011 74ACT11011 MIN MIN MAX 4.5 V 4.4 4.4 4.4 5.5 V 5.4 5.4 5.4 4.5 V 3.94 3.7 3.8 5.5 V 4.94 4.7 4.8 5.5 V IOL = 50 mA} IOL = 75 mA} V 0.1 0.1 5.5 V 0.1 0.1 0.1 4.5 V 0.36 0.5 0.44 5.5 V 0.36 0.5 0.44 5.5 V 0.1 V 1.65 5.5 V 1.65 II ICC VI = VCC or GND VI = VCC or GND, 5.5 V ± 0.1 ±1 ±1 IO = 0 5.5 V 4 80 40 mA mA DICC§ One input at 3.4 V, Other inputs at GND or VCC 5.5 V 0.9 1 1 mA Ci VI = VCC or GND 5V 3.5 ‡ Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms. § This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC. 2–2 UNIT 3.85 4.5 V IOL = 24 mA MAX 3.85 5.5 V IOL = 50 mA VOL VCC POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 pF 54ACT11011, 74ACT11011 TRIPLE 3-INPUT POSITIVE-AND GATES SCAS028A – D2957, JULY 1987 – REVISED APRIL 1993 switching characteristics over recommended ranges of supply voltage and free-air temperature (unless otherwise noted) (see Figure 1) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A B, A, B or C Y MIN TA = 25°C TYP MAX 54ACT11011 74ACT11011 MIN MAX MIN MAX 1.5 6.5 8.6 1.5 10.2 1.5 9.6 1.5 5.5 7.9 1.5 9.2 1.5 8.7 UNIT ns operating characteristics, VCC = 5 V, TA = 25°C PARAMETER Cpd TEST CONDITIONS Power dissipation capacitance per gate CL = 50 pF, f = 1 MHz TYP UNIT 28 pF PARAMETER MEASUREMENT INFORMATION Input (see Note B) From Output Under Test CL = 50 pF (see Note A) 3V 1.5 V 1.5 V 0V tPLH tPHL 500 Ω 50% VCC Output VOH 50% VCC VOL VOLTAGE WAVEFORMS LOAD CIRCUIT NOTES: A. CL includes probe and jig capacitance. B. Input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns. C. The outputs are measured one at a time with one input transition per measurement. Figure 1. Load Circuit and Voltage Waveforms POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 2–3 54ACT11011, 74ACT11011 TRIPLE 3-INPUT POSITIVE-AND GATES SCAS028A – D2957, JULY 1987 – REVISED APRIL 1993 2–4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1998, Texas Instruments Incorporated