Conduit & Accessories M24758/5 Conduit-to-Panel Fitting M24758/5-16-A Material Designator: A = Aluminum B = Brass C = CRES 316 Basic Part No. Conduit Size Code .6875 (17.5) L .1875 (4.8) Tapered Sleeve Conduit P Dia D Dia M Dia Coupling Nut A Thread E Nuts (2) Weather Gasket Straight Knurl, Medium Coarse, 4 Places TABLE I Conduit Size Code 02 03 04 05 06 08 10 12 16 20 24 A Thread (Class 2A) 0.625 - 24 UNEF 0.750 - 20 UNEF 0.875 - 20 UNEF 1.000 - 20 UNEF 1.188 - 18 UNEF 1.438 - 18 UNEF 1.750 - 16 UN 2.000 - 16 UN 2.500 - 16 UN 3.000 - 16 UN 3.500 - 16 UN D Dia (Minimum) .250 (6.4) .370 (9.4) .500 (12.7) .620 (15.7) .750 (19.1) 1.000 (25.4) 1.250 (31.8) 1.500 (38.1) 2.000 (50.8) 2.500 (63.5) 3.000 (76.2) E Knurl Length ±.06 (15.2) .500 (12.7) .500 (12.7) .620 (15.7) .620 (15.7) .750 (19.1) .750 (19.1) .870 (22.1) .870 (22.1) 1.000 (25.4) 1.000 (25.4) 1.000 (25.4) L Cone Length ±.06 (15.2) .750 (19.1) .750 (19.1) .750 (19.1) .750 (19.1) .750 (19.1) 1.000 (25.4) 1.000 (25.4) 1.000 (25.4) 1.000 (25.4) 1.000 (25.4) 1.000 (25.4) M Dia (Maximum) .930 (23.6) 1.120 (28.4) 1.250 (31.8) 1.430 (36.3) 1.620 (41.1) 1.810 (46.0) 2.180 (55.4) 2.560 (65.0) 3.060 (77.7) 3.680 (93.5) 4.380 (111.3) P Dia (Minimum) .870 (22.1) 1.000 (25.4) 1.120 (28.4) 1.250 (31.8) 1.430 (36.3) 1.680 (42.7) 2.000 (50.8) 2.250 (57.2) 3.000 (76.2) 3.500 (88.9) 4.000 (101.6) 1. The function of the M24758/5 fitting is to terminate flexible shielding conduit directly to a panel. Two jam nuts are supplied with this fitting. One nut secures the fitting to the panel, and a second nut acts as a lock nut to the first. 2. Metric dimensions (mm) are indicated in parentheses. 3. For complete dimensions see applicable Military Specification. © 2005 Glenair, Inc. CAGE Code 06324 Printed in U.S.A. GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912 71-6 www.glenair.com E-Mail: [email protected]