Ultra Low Loss Isolator 860 MHz — 960 MHz MAFRIN0448 Version 02 Features • • • • • <0.1 dB Insertion Loss Designed for wireless base station market 25 dB Isolation typical Low cost 31.75mm Drop-In package RoHs Compliant Description This circulator is designed specifically for wireless base station applications and features high reliability performance at a low cost. It is in a low cost package ideally suited for high volume manufacturing. M/A-Com is one of the largest suppliers of isolators and circulators in the world. Electrical Specifications: TA = +25°C, Z0 = 50 Ohms Parameter Test Conditions Units Minimum Frequency Range Over Top 1 MHz 860 Insertion Loss Isolation Return Loss Over Top dB Over Top 1 dB 23.0 25.0 Over Top 1 dB 22.0 25.0 IM3, 2 tones, 30 Watts each over Top 1 IM5, 2 tones, 30 Watts each over Top 1 (see table) 1 0.1 dBc Insertion Delay @ 883MHz, Test Fixture Degree Delay Test Fixture Removed nSec Over Top 0.08 dBc 1 tone @ 30 Watts of Top Circulation Maximum 960 1 Intermodulation Product Harmonics Typical 1 CW 1. See “Absolute Maximum Ratings” for Top. Absolute Maximum Ratings: Ordering Information Parameter Absolute Maximum Part Number Packaging Forward Power 200 Watts MAFRIN0448 Flat Pack Operating Temperature -20°C to +70°C Storage Temperature -40°C to +100°C 1. Operation of this device above any one of these parameters may cause permanent damage. 1 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information. • North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information. Ultra Low Loss Isolator 860 MHz — 960 MHz MAFRIN0448 Version 02 Isolation (S12) Insertion Loss (S21) -20°C +25°C +80°C -20°C -20 -25 -0.10 dB dB -0.05 -0.15 -30 -35 -0.20 -40 860 880 900 920 940 960 -45 840 980 860 FREQUENCY (MHz) -20°C 900 920 940 960 980 960 980 Return Loss (S22) +25°C +80°C -20°C -15 -15 -20 -20 dB -25 dB 880 FREQUENCY (MHz) Return Loss (S11) -30 -35 +25°C +80°C -25 -30 -35 -40 -45 840 +80°C -15 0.00 -0.25 840 +25°C 860 880 900 920 940 960 980 FREQUENCY (MHz) -40 840 860 880 900 920 940 FREQUENCY (MHz) 2 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information. • North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information. Ultra Low Loss Isolator 860 MHz — 960 MHz MAFRIN0448 Version 02 Environmental Specifications Outline Drawing Devices are designed to function after exposure to the shock, vibration, thermal shock and moisture conditions typically encountered in base station and other infrastructure environments. S-Parameters S-parameters are available on the M/A Com website at: www.macom.com/tech_app_resources/techapp_design_info Port Description: Port Number Description 1 RF In 2 RF Out 3 Terminated 1. 2. 3. 4. 5. Dimensions in mm. Tolerances: ± 0.3 mm unless otherwise noted. Housing: Cold Rolled Steel with SnPb 90/10 plating. Cover: CRS with SnPb 90/10 plating. Leads: Copper. 3 M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. M/A-COM makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does M/A-COM assume any liability whatsoever arising out of the use or application of any product(s) or information. • North America Tel: 800.366.2266 / Fax: 978.366.2266 • Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300 • Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298 Visit www.macom.com for additional data sheets and product information.