MA-COM MAAVSS0001TR-3000

RoHS
Compliant
2.25 V Voltage Variable Absorptive Attenuator, 42 dB
1.8 - 2.5 GHz
Features
•
•
•
•
•
•
•
•
MAAVSS0001
V3
Functional Schematic
Single Positive Voltage Control, 0 to +2.25 Volts
42 dB Typical Attenuation Range at 2.4 GHz
Low DC Power Consumption
Lead-Free SOT-25 Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
260°C Reflow Compatible
RoHS* Compliant Version of AT-119
5
VCC
4
VCTL
Description
M/A-COM’s MAAVSS0001 is a GaAs MMIC voltage
variable absorptive attenuator in a lead-free
SOT-25 surface mount plastic package. M/A-COM
fabricates the MAAVSS0001 with a proven
monolithic GaAs 0.5 micron gate process that
features full chip passivation for performance and
reliability.
1
RF
2
GND
3
RF
100pF
Applications
The MAAVSS0001 is ideally suited for applications
that require fine tuning, linear attenuation with
voltage, and very low power consumption.
Pin Configuration
Typical applications for the MAAVSS0001 include
automatic gain control circuits in satellite radio
receivers and other wireless receivers.
Ordering Information1
Part Number
Package
MAAVSS0001
Bulk Packaging
MAAVSS0001TR-3000
3000 piece reel
MAAVSS0001SMB
Sample Test Board
(Includes 5 Samples)
100pF
Pin
Function
Description
1
RF
RF (input / output)
2
GND
Ground
3
RF
RF (input / output)
4
VCTL
Control Voltage
5
VCC
DC Supply Voltage
Absolute Maximum Ratings 2,3
@ TA = +25°C (unless otherwise specified)
1. Reference Application Note M513 for reel size information.
Parameter
Absolute Maximum
Input Power
+21 dBm
Supply Voltage VCC
-1 V ≤ VCC ≤ +8 V
Control Voltage VCTL
-1 V ≤ VCTL ≤ VCC +0.5 V
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
2.25 V Voltage Variable Absorptive Attenuator, 42 dB
1.8 - 2.5 GHz
MAAVSS0001
V3
Electrical Specifications: TA = 25°C, Frequency = 2.4 GHz, VCC = 3.3 V, Z0 = 50 Ω
Parameter
Test Conditions 4,5
Units
Min.
Typ.
Max.
Insertion Loss
VCTL = 2.25 V
dB
—
2.4
3.2
Maximum Attenuation
VCTL = 0.5 V
dB
37
42
—
Attenuation Slope
0.75 V < VCTL < 1.75 V
dB/V
24
—
—
Return Loss
0.0 V < VCTL < 0.75 V
0.75 V < VCTL < 1.75 V
1.75 V < VCTL < 2.25 V
dB
dB
dB
—
—
—
6
10
14
—
—
—
Input Power for 1dB Change in Attenuation
0.75 V < VCTL < 2.25 V
dBm
—
10
—
Input 3rd Order Intercept Point
0.75 V < VCTL < 2.25 V
dBm
—
15
—
Switching Speed
50% VCTL to 10% / 90% RF
nS
—
100
—
Transients
VCTL = 3 V, In-Band
mV
—
10
—
4. External DC blocking capacitors are required on all RF ports.
5. VCC = +3.3 V @ 50 µA typical. VCTL = 0 V to +2.25 V @ 50 µA typical.
Application Schematic
Handling Procedures
VCC
VCTL
Static Sensitivity
100 pF
RF IN/
OUT
Please observe the following precautions to avoid
damage:
220 pF
100 pF
RF IN/
OUT
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
15 pF
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
2.25 V Voltage Variable Absorptive Attenuator, 42 dB
1.8 - 2.5 GHz
MAAVSS0001
V3
Typical Performance Curves
Attenuation vs. Control Voltage @ +25°C
Insertion Loss vs. Frequency
@ 2.25 V Control Voltage
4.0
0
3.5
10
3.0
20
2.5
2.0
30
1.5
40
+25°C
-40°C
+85°C
1.0
1.8 GHz
2.1 GHz
2.4 GHz
50
0.5
0.0
60
0.5
1.0
1.5
2.0
2.5
3.0
3.0
2.5
Frequency (GHz)
2.0
1.5
1.0
0.5
0.0
Control Voltage (Volts)
Typical Device Variation, 2.4 GHz
Attenuation vs. Frequency @ 0.0 V Control Voltage
0
0
10
10
20
20
30
30
40
40
50
50
+25°C
-40°C
+85°C
60
60
3.0
2.5
2.0
1.5
1.0
0.5
0.5
0.0
1.0
1.5
2.0
2.5
3.0
Frequency (GHz)
Control Voltage (Volts)
Return Loss vs. Control Voltage
Insertion Loss Delta Normalized to +25°C (-40°C)
0
8
6
-5
4
-10
2
-15
0
-2
-20
1.8 GHz
2.1 GHz
2.4 GHz
1.8 GHz
2.1 GHz
2.4 Ghz
-4
-25
-6
-30
-8
2.0
1.5
1.0
0.5
0.0
Control Voltage (Volts)
3
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Control Voltage (Volts)
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
RoHS
Compliant
2.25 V Voltage Variable Absorptive Attenuator, 42 dB
1.8 - 2.5 GHz
MAAVSS0001
V3
Typical Performance Curves
Insertion Loss Delta Normalized to +25°C (+85°C)
Input IP3 vs. Control Voltage @ +25°C
8
40
6
35
4
30
2
25
0
20
-2
15
1.8 GHz
2.1 GHz
2.4 GHz
-4
10
5
-6
0
-8
3.0
2.5
2.0
1.5
1.0
0.5
3.0
0.0
2.5
2.0
1.5
1.0
0.5
0.0
Control Voltage (Volts)
Control Voltage (Volts)
Input Power for 1 dB Change in Attenuation
Input IP3 vs. Control Voltage over Temperature
40
30
IIP3 @ +25C
IIP3 @ +85C
IIP3 @ -40C
35
25
30
20
25
20
15
15
10
10
5
1.8 GHz
2.4 GHz
5
0
3.0
0
3.0
2.5
2.0
1.5
1.0
0.5
0.0
2.5
2.0
1.5
1.0
0.5
0.0
Control Voltage (V)
Control Voltage (Volts)
Lead-Free SOT-25†
†
Reference Application Note M538 for lead-free solder reflow recommendations.
4
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.