MA-COM FR41-0007

Small Profile Drop-In Circulator
FR41-Series
FR41-Series
Small Profile Drop-In Circulator
Features
•
•
•
•
FR41
24 dB Isolation Typical, 0.25 dB Insertion Loss Typical
Custom Products Available with Alternate Configurations
such as Couplers, Attenuators, Higher Power Terminations,
Reverse Circulation and Termination on Ports 1 or 2
Available as Custom Product Without Flange for Surface
Mount Applications (Solder Reflow)
Designed for Wireless Telecommunications Systems:
AMPS, N-AMPS, D-AMPS
Description
M/A-COM’s drop-in circulators and isolators, designed for
cellular applications, feature high performance at low cost. These
designs offer the best isolation per insertion loss ratio in the
industry and are currently produced in the tens of thousands of
pieces per year. These units can be ordered so as to be compatible
with solder reflow manufacturing techniques. Both circulators and
isolators are in stock at all authorized M/A-COM distributors.
Part Number
Frequency Range (MHz)
FR41-0001
FR41-0002
FR41-0003
FR41-0004
FR41-0005
FR41-0006
FR41-0007
FR41-0008
869 – 894
925 – 960
1805 – 1880
1930 – 1990
824 – 849
880 – 915
1710 – 1785
1850 – 1910
Electrical Specifications
Units
Min.
-10 to +60° C
Typ.
Isolation
dB
22
24
—
20
22
—
Insertion Loss
dB
—
0.25
0.3
—
0.30
0.35
Forward Power
Watts
—
—
65
—
—
65
—
—
—
1.20
—
—
1.22
Parameter
VSWR
Max.
Min.
-30 to +85° C
Typ.
Max.
V2.00
M/A-COM Division of AMP Incorporated n North America: Tel. (800) 366-2266, Fax (800) 618-8883 n Asia/Pacific: Tel.+85 2 2111 8088, Fax +85 2 2111 8087
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
www.macom.com
AMP and Connecting at a Higher Level are trademarks.
Specifications subject to change without notice.
Small Profile Drop-In Circulator
FR41-Series
Typical Performance, T = +25°C
FR41-0001
Isolation
Insertion Loss
0
0
-5
-0.1
Insertion Loss (dB)
Isolation (dB)
-10
-15
-20
-25
-30
-0.2
-0.3
-0.4
-35
-0.5
917
884
852
819
-0.6
917
884
819
-45
852
-40
Frequency (MHz)
Frequency (MHz)
FR41-0002
Insertion Loss
Isolation
0
0
-5
-0 .1
Insertion Loss (dB)
Isolation (dB)
-1 0
-1 5
-2 0
-2 5
-3 0
-3 5
-0 .2
-0 .3
-0 .4
-0 .5
-4 0
-0 .6
-4 5
875
908
940
973
875
1005
908
940
973
1005
F re q u e n c y (M H z )
F r e q u e n c y (M H z )
FR41-0003
Insertion Loss
Isolation
0
0
-5
-0 .0 5
Insertion Loss (dB)
Isolation (dB)
-1 0
-1 5
-2 0
-2 5
-3 0
-3 5
-4 0
- 0 .1
-0 .1 5
- 0 .2
-0 .2 5
- 0 .3
-4 5
-5 0
1750
1795
1840
1885
-0 .3 5
1750
1930
1795
1840
1885
1930
F re q u e n c y (M H z)
F re q u e n c y (M H z )
FR41-0004
Isolation
Insertion Loss
0
0
-5
-0 .0 5
Insertion Loss (dB)
Isolation (dB)
-1 0
-1 5
-2 0
-2 5
-3 0
-3 5
-4 0
-0 .2
-0 .2 5
-0 .3
-4 5
-5 0
1880
-0 .1
-0 .1 5
1912
1943
1975
2006
F re q u e n c y (M H z )
-0 .3 5
1880
1912
1943
1975
2006
F re q u e n c y (M H z)
V2.00
M/A-COM Division of AMP Incorporated n North America: Tel. (800) 366-2266, Fax (800) 618-8883 n Asia/Pacific: Tel.+85 2 2111 8088, Fax +85 2 2111 8087
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
www.macom.com
AMP and Connecting at a Higher Level are trademarks.
Specifications subject to change without notice.