E-Series 75 Ohm Coupler — 5 - 870 MHz
ELDC-8LI-1
E-Series 75 Ohm Coupler
5 - 870 MHZ
SM - 115
Features
•
•
•
•
Low Intermod Distortion
Coupling 8.5dB Typical
Surface Mount
Tape and Reel Packaging available
Description
M/A-COM’s ELDC-8LI-1 is a high performance 75 Ohm
Coupler, in a SM-115 low cost, surface mount package. The
ELDC-8LI-1 is specifically designed for extremely low intermod
distortion in CATV appliications.
Electrical Specifications @25°C
Frequency Range 5 - 870 MHz
Units
Nominal
Typical
Minimum
Maximum
Mainline Loss
5 - 870 MHz
dB
—
1.8
—
2.9
Coupling
5 - 870 MHz
dB
8.3
—
—
± 0.5
dB
—
—
—
1.0
5 - 250 MHz
250 –500 MHz
500 - 870 MHz
dB
dB
dB
—
—
—
28
24
18
23
20
15
—
—
—
Input Return Loss
5 - 20 MHz
20 –500 MHz
500 - 870 MHz
dB
dB
dB
—
—
—
17
20
16
15
17
13
—
—
—
Output Return Loss
5 - 450 MHz
450 - 650 MHz
650 –870 MHz
dB
dB
dB
—
—
—
28
18
16
20
16
14
—
—
—
Coupled Return Loss
40 - 600 MHz
600 –870 MHz
650 - 870 MHz
dB
dB
dB
—
—
—
17
20
17
15
17
15
—
—
—
Coupling Flatness
Isolation
Please Note that the photograph above indicates package shape only, unit may be wired differently.
S 1491 C
M/A-COM Division of AMP Incorporated ■ North America: Tel. (800) 366-2266, Fax (800) 618-8883 ■ Asia/Pacific: Tel.+85 2 2111 8088,
Fax +85 2 2111 8087 ■ Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
www.macom.com
AMP and Connecting at a Higher Level are trademarks.
Specifications subject to change without notice.
E-Series 75 Ohm Coupler — 5 - 870 MHz
ELDC-8LI-1
Operating Characteristics
Absolute Maximum Ratings
Function
Pin No.
Parameter
Absolute Maximum
Input
6
RF Power
250 mW
Output
1
DC Current
30 mA
Coupled
4
Pin Temperature (10 sec)
260°C
Ground
5
Operating/Storage Temperature
-40°C to +85°C
Not Connected
2
External 75 Ohms
3
Typical Performance @ 25°C
Mainline Loss
Input Return Loss
0.0
0.0
-0.5
-5.0
-1.0
dB
dB
-10.0
-1.5
-15.0
-2.0
-2.5
-20.0
-3.0
5.0
178.0
351.0
524.0
697.0
-25.0
870.0
5.0
178.0
Frequency (MHz)
351.0
524.0
697.0
870.0
697.0
870.0
697.0
870.0
Frequency (M Hz)
Coupling
Output Return Loss
-7.0
5.0
0.0
-7.5
-5.0
-10.0
dB
dB
-8.0
-8.5
-15.0
-20.0
-9.0
-25.0
-9.5
-30.0
-10.0
-35.0
5.0
178.0
351.0
524.0
697.0
870.0
5.0
178.0
Frequency (M H z)
351.0
524.0
Frequency (M Hz)
Isolation
Coupled Port Return Loss
0.0
0.0
-5.0
-5.0
-10.0
dB
dB
-10.0
-15.0
-15.0
-20.0
-20.0
-25.0
-30.0
-25.0
5.0
178.0
351.0
524.0
697.0
870.0
Frequency (M H z)
5.0
178.0
351.0
524.0
Frequency (M Hz)
S 1491 C
M/A-COM Division of AMP Incorporated ■ North America: Tel. (800) 366-2266, Fax (800) 618-8883 ■ Asia/Pacific: Tel.+85 2 2111 8088,
Fax +85 2 2111 8087 ■ Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
www.macom.com
AMP and Connecting at a Higher Level are trademarks.
Specifications subject to change without notice.