VISHAY 30CTQ050

30CTQ...PbF Series
Vishay High Power Products
Schottky Rectifier, 2 x 15 A
FEATURES
•
•
•
•
Base 2
common
cathode
150 °C TJ operation
Center tap configuration
Very low forward voltage drop
High frequency operation
Pb-free
Available
RoHS*
COMPLIANT
• High purity, high temperature epoxy
encapsulation for enhanced mechanical strength and
moisture resistance
TO-220AB
Anode
2
1 Common 3
cathode
Anode
• Guard ring for enhanced ruggedness and long term
reliability
• Lead (Pb)-free (“PbF” suffix)
• Designed and qualified for industrial level
DESCRIPTION
PRODUCT SUMMARY
IF(AV)
2 x 15 A
VR
50/60 V
This center tap Schottky rectifier has been optimized for very
low forward voltage drop, with moderate leakage. The
proprietary barrier technology allows for reliable operation up
to 150 °C junction temperature. Typical applications are in
switching power supplies, converters, freewheeling diodes,
and reverse battery protection.
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL
IF(AV)
CHARACTERISTICS
VALUES
Rectangular waveform
VRRM
UNITS
30
A
50/60
V
IFSM
tp = 5 µs sine
1000
A
VF
15 Apk, TJ = 125 °C (per leg)
0.56
V
TJ
Range
- 55 to 150
°C
VOLTAGE RATINGS
PARAMETER
SYMBOL
Maximum DC reverse voltage
30CTQ050PbF
30CTQ060PbF
UNITS
50
60
V
VR
Maximum working peak reverse voltage
VRWM
ABSOLUTE MAXIMUM RATINGS
PARAMETER
Maximum average
forward current
See fig. 5
SYMBOL
TEST CONDITIONS
VALUES
UNITS
30
per device
IF(AV)
50 % duty cycle at TC = 105 °C, rectangular waveform
per leg
15
A
Following any rated load
condition and with rated
VRRM applied
Maximum peak one cycle
non-repetitive surge current per leg
See fig. 7
IFSM
Non-repetitive avalanche energy per leg
EAS
TJ = 25 °C, IAS = 1.50 A, L = 11.5 mH
Repetitive avalanche current per leg
IAR
Current decaying linearly to zero in 1 µs
Frequency limited by TJ maximum VA = 1.5 x VR typical
5 µs sine or 3 µs rect. pulse
10 ms sine or 6 ms rect. pulse
1000
260
13
mJ
1.50
A
* Pb containing terminations are not RoHS compliant, exemptions may apply
Document Number: 94189
Revision: 13-Aug-08
For technical questions, contact: [email protected]
www.vishay.com
1
30CTQ...PbF Series
Vishay High Power Products Schottky Rectifier, 2 x 15 A
ELECTRICAL SPECIFICATIONS
PARAMETER
SYMBOL
TEST CONDITIONS
15 A
Maximum forward voltage drop per leg
See fig. 1
VFM (1)
TJ = 25 °C
30 A
15 A
TJ = 125 °C
30 A
Maximum reverse leakage current per leg
See fig. 2
IRM (1)
Threshold voltage
VF(TO)
Forward slope resistance
rt
Maximum junction capacitance per leg
CT
Typical series inductance per leg
LS
Maximum voltage rate of change
dV/dt
TJ = 25 °C
VR = Rated VR
TJ = 125 °C
TJ = TJ maximum
VR = 5 VDC (test signal range 100 kHz to 1 MHz) 25 °C
Measured lead to lead 5 mm from package body
Rated VR
VALUES
UNITS
0.62
0.82
V
0.56
0.71
0.80
mA
45
0.39
V
8.47
mΩ
720
pF
8.0
nH
10 000
V/µs
VALUES
UNITS
- 55 to 150
°C
Note
(1) Pulse width < 300 µs, duty cycle < 2 %
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
Maximum junction and storage
temperature range
TEST CONDITIONS
TJ, TStg
Maximum thermal resistance,
junction to case per leg
3.25
RthJC
Maximum thermal resistance,
junction to case per package
DC operation
1.63
Typical thermal resistance,
case to heatsink
RthCS
Mounting surface, smooth and greased
Marking device
www.vishay.com
2
0.50
2
g
0.07
oz.
minimum
6 (5)
kgf · cm
maximum
12 (10)
(lbf · in)
Approximate weight
Mounting torque
°C/W
Case style TO-220AB
For technical questions, contact: [email protected]
30CTQ050
30CTQ060
Document Number: 94189
Revision: 13-Aug-08
30CTQ...PbF Series
1000
1000
IR - Reverse Current (mA)
IF - Instantaneous Forward Current (A)
Schottky Rectifier, 2 x 15 A Vishay High Power Products
100
10
TJ = 150 °C
TJ = 125 °C
TJ = 25 °C
1
TJ = 150 °C
100
TJ = 125 °C
10
TJ = 100 °C
1
TJ = 75 °C
0.1
TJ = 50 °C
0.01
TJ = 25 °C
0.001
0
0.4
0.8
1.2
0
2.0
1.6
10
20
30
40
50
60
VFM - Forward Voltage Drop (V)
VR - Reverse Voltage (V)
Fig. 1 - Maximum Forward Voltage Drop Characteristics
(Per Leg)
Fig. 2 - Typical Values of Reverse Current vs.
Reverse Voltage (Per Leg)
CT - Junction Capacitance (pF)
1000
TJ = 25 °C
100
0
10
20
30
40
50
60
VR - Reverse Voltage (V)
ZthJC - Thermal Impedance (°C/W)
Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage (Per Leg)
10
1
PDM
0.1
0.01
Single pulse
(thermal resistance)
0.001
0.00001
0.0001
t1
D = 0.75
D = 0.50
D = 0.33
D = 0.25
D = 0.20
0.001
0.01
t2
Notes:
1. Duty factor D = t1/t2
2. Peak TJ = PDM x ZthJC + TC
0.1
1
10
100
t1 - Rectangular Pulse Duration (s)
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics (Per Leg)
Document Number: 94189
Revision: 13-Aug-08
For technical questions, contact: [email protected]
www.vishay.com
3
30CTQ...PbF Series
Vishay High Power Products Schottky Rectifier, 2 x 15 A
14
150
140
DC
130
120
110
Square wave (D = 0.50)
80 % rated VR applied
100
90
80
See note (1)
D = 0.20
D = 0.25
D = 0.33
D = 0.50
D = 0.75
12
Average Power Loss (W)
Allowable Case Temperature (°C)
160
10
8
RMS limit
6
DC
4
2
70
60
0
0
5
15
10
20
25
5
0
10
15
20
25
IF(AV) - Average Forward Current (A)
Fig. 5 - Maximum Allowable Case Temperature vs.
Average Forward Current (Per Leg)
Fig. 6 - Forward Power Loss Characteristics (Per Leg)
IFSM - Non-Repetitive Surge Current (A)
IF(AV) - Average Forward Current (A)
1000
At any rated load condition
and with rated VRRM applied
following surge
100
10
100
10 000
1000
tp - Square Wave Pulse Duration (µs)
Fig. 7 - Maximum Non-Repetitive Surge Current (Per Leg)
L
D.U.T.
IRFP460
Rg = 25 Ω
Current
monitor
High-speed
switch
Freewheel
diode
+ Vd = 25 V
40HFL40S02
Fig. 8 - Unclamped Inductive Test Circuit
Note
Formula used: TC = TJ - (Pd + PdREV) x RthJC;
Pd = Forward power loss = IF(AV) x VFM at (IF(AV)/D) (see fig. 6);
PdREV = Inverse power loss = VR1 x IR (1 - D); IR at VR1 = 10 V
(1)
www.vishay.com
4
For technical questions, contact: [email protected]
Document Number: 94189
Revision: 13-Aug-08
30CTQ...PbF Series
Schottky Rectifier, 2 x 15 A Vishay High Power Products
ORDERING INFORMATION TABLE
Device code
30
C
T
Q
1
2
3
4
060 PbF
5
1
-
Current rating (30 = 30 A)
2
-
Circuit configuration:
6
C = Common cathode
3
-
Package
T = TO-220
4
-
Schottky “Q” series
5
-
Voltage ratings
6
-
050 = 50 V
060 = 60 V
None = Standard production
PbF = Lead (Pb)-free
Tube standard pack quantity: 50 pieces
LINKS TO RELATED DOCUMENTS
Dimensions
http://www.vishay.com/doc?95222
Part marking information
http://www.vishay.com/doc?95225
Document Number: 94189
Revision: 13-Aug-08
For technical questions, contact: [email protected]
www.vishay.com
5
Outline Dimensions
Vishay Semiconductors
TO-220AB
DIMENSIONS in millimeters and inches
A
(6)
E
E2
ØP
0.014 M B A M
(7)
A
B
Seating
plane
A
Thermal pad
(E)
A1
1
Q
(6)
D
(H1)
H1
(7)
C
D2 (6)
(6) D
2 3
D
L1 (2)
C
Detail B
D1
3xb
1
2
3
3 x b2
Detail B
C
E1 (6)
L
Base metal
View A - A
c
Plating
c1 (4)
c
A
2x e
A2
e1
(b, b2)
b1, b3
(4)
Section C - C and D - D
0.015 M B A M
Lead assignments
Lead tip
Diodes
Conforms to JEDEC outline TO-220AB
1. - Anode/open
2. - Cathode
3. - Anode
SYMBOL
MILLIMETERS
MIN.
MAX.
4.25
4.65
1.14
1.40
2.56
2.92
0.69
1.01
0.38
0.97
1.20
1.73
1.14
1.73
0.36
0.61
0.36
0.56
14.85
15.25
8.38
9.02
11.68
12.88
INCHES
MIN.
MAX.
0.167
0.183
0.045
0.055
0.101
0.115
0.027
0.040
0.015
0.038
0.047
0.068
0.045
0.068
0.014
0.024
0.014
0.022
0.585
0.600
0.330
0.355
0.460
0.507
NOTES
A
A1
A2
b
b1
4
b2
b3
4
c
c1
4
D
3
D1
D2
6
Notes
(1) Dimensioning and tolerancing as per ASME Y14.5M-1994
(2) Lead dimension and finish uncontrolled in L1
(3) Dimension D, D1 and E do not include mold flash. Mold flash
shall not exceed 0.127 mm (0.005") per side. These dimensions
are measured at the outermost extremes of the plastic body
(4) Dimension b1, b3 and c1 apply to base metal only
(5) Controlling dimensions: inches
(6) Thermal pad contour optional within dimensions E, H1, D2 and
E1
Document Number: 95222
Revision: 08-Mar-11
SYMBOL
E
E1
E2
e
e1
H1
L
L1
ØP
Q

(7)
(8)
MILLIMETERS
MIN.
MAX.
10.11
10.51
6.86
8.89
0.76
2.41
2.67
4.88
5.28
6.09
6.48
13.52
14.02
3.32
3.82
3.54
3.73
2.60
3.00
90° to 93°
INCHES
MIN.
MAX.
0.398
0.414
0.270
0.350
0.030
0.095
0.105
0.192
0.208
0.240
0.255
0.532
0.552
0.131
0.150
0.139
0.147
0.102
0.118
90° to 93°
NOTES
3, 6
6
7
6, 7
2
Dimensions E2 x H1 define a zone where stamping and
singulation irregularities are allowed
Outline conforms to JEDEC TO-220, except A2 (maximum) and
D2 (minimum) where dimensions are derived from the actual
package outline
For technical questions within your region, please contact one of the following:
[email protected], [email protected], [email protected]
www.vishay.com
1
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 11-Mar-11
www.vishay.com
1