RHOMBUS-IND T

T1/CEPT/ISDN-PRI Pulse Transformer
Reinforced Insulation Per EN 41003/EN 60950
Turns Ratio* ( + 5% )
1CT:1.41CT
Parameter
Min.
Open Circuit Inductance*
1.2
Max.
Units
mH
Oscillation Voltage = 20mV
Oscillation Frequency = 100.0 KHz
Schematic Diagram
0.80
µH
20
pF
Primary DC Resistance
0.6
ohms
Secondary DC Resistance
0.8
ohms
Leakage Inductance
Oscillation Level = 20mV
Oscillation Frequency = 100.0 KHz
Interwinding Capacitance (CW/W)
Oscillation Frequency = 100.0 KHz
Isolation (HI-POT)
3000
V RMS
*Turns ratio is Primary to Secondary. Primary Pins 10-6 center tap pin 5 to
Secondary pins 1-5 center tap pin 3
1
Tested on Primary Pins 10-6
Flammability: Materials used in the production of these
units are UL94-VO and meet requirements of IEC 6952-2 needle flame test.
Physical Dimensions
inches (mm)
RHOMBUS P/N: T-13637
CUST P/N:
DATE: 07/02/98
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
NAME:
SHEET: 1 OF 1
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971