MAXIM MAX71020AEUI+R

19-6400; Rev 0; 7/12
MAX71020
Single-Chip Electricity Meter AFE
General Description
Features
S0.1% Accuracy Over 2000:1 Current Range
SExceeds IEC 62053/ANSI C12.20 Standards
STwo Differential Current Sensor Inputs
STwo Voltage Sensor Inputs
SSelectable Gain of 1 or 9 for One Current Input to
Support a Shunt
SHigh-Speed Wh/VARh Pulse Outputs with
Programmable Width
SUp to Four Pulse Outputs with Pulse Count
SFour-Quadrant Metering
SDigital Temperature Compensation
SIndependent 32-Bit Compute Engine
S45Hz to 65Hz Line Frequency Range with Same
Calibration
SPhase Compensation (±10°)
SFour Multifunction DIO Pins
S SPI Interface
S -40°C to +85°C Industrial Temperature Range
S 28-Pin TSSOP Lead(Pb)-Free Package
The MAX71020 is a single-chip, analog front-end to be
used in high-performance revenue meters. It contains
the compute engine found in Maxim’s fourth-generation
meter SOC and an improved ADC, and interfaces to the
host microcontroller of choice over a SPI interface.
The MAX71020 comes in a 28-pin TSSOP package.
Ordering Information appears at end of data sheet.
For related parts and recommended products to use with this part,
refer to www.maxim-ic.com/MAX71020.related.
Typical Operating Circuit
CT
NEUTRAL
LINE
SHUNT
LOAD
NOTE: THIS SYSTEM IS REFERENCED TO LINE
NEUTRAL
POWER SUPPLY
LINE
LINE
RESISTORDIVIDER
MUX AND ADC
IAP
IAN
V3P3A
V3P3SYS
GNDA
GNDD
MAX71020
VA
REGULATOR
VB
IBP
TEMPERATURE SENSOR
IBN
VREF
COMPUTE ENGINE
POWER-FAULT
COMPARATOR
DIO, PULSES
HOST
OSCILLATOR/PLL
XIN
SPI
INTERFACE
9.8304MHz
XOUT
For pricing, delivery, and ordering information, please contact Maxim Direct
at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
1
MAX71020
Single-Chip Electricity Meter AFE
ABSOLUTE MAXIMUM RATINGS
(All voltages with respect to GNDA.)
Voltage and Current Supplies and Ground Pins
V3P3SYS, V3P3A...................................................-0.5V to +4.6V
GNDD....................................................................-0.1V to +0.1V
Analog Input Pins
IAP, IAN, IBP, IBN, VA, VB.............................(-10mA to +10mA),
(-0.5V to (V3P3A + 0.5V))
XIN, XOUT.......................... (-10mA to +10mA), (-0.5V to +3.0V)
Digital Pins
Inputs..................................... (-10mA to +10mA), (-0.5V to +6V)
Outputs............. (-10mA to +10mA), (-0.5V to (V3P3SYS + 0.5V))
Temperature and ESD Stress
Operating Junction Temperature (peak, 100ms)............... 140°C
Operating Junction Temperature (continuous).................. 125°C
Storage Temperature Range............................. -45°C to +165°C
ESD Stress on All Pins...............................................±4kV, HBM
Lead Temperature (soldering, 10s)................................... 300°C
Soldering Temperature (reflow).......................................+250°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
PACKAGE THERMAL CHARACTERISTICS (Note 1)
TSSOP
Junction-to-Ambient Thermal Resistance (qJA)...........78°C/W
Junction-to-Case Thermal Resistance (qJC)................ 13NC/W
Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a fourlayer board. For detailed information on package thermal considerations, refer to www.maxim-ic.com/thermal-tutorial.
ELECTRICAL CHARACTERISTICS
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
RECOMMENDED OPERATING CONDITIONS
V3P3SYS and V3P3A Supply Voltage
Precision metering operation
3.0
3.6
Digital operation
2.8
3.6
-40
+85
Operating Temperature
V
NC
INPUT LOGIC LEVELS
Digital High-Level Input Voltage (VIH)
2
V
Digital Low-Level Input Voltage (VIL)
0.8
V
Input Pullup Current (IIL) RESETZ
VV3P3SYS = 3.6V, VIN = 0V
41
78
115
FA
Input Pullup Current (IIL) Other
Digital Inputs
VV3P3SYS = 3.6V, VIN = 0V
-1
0
+1
FA
Input Pulldown Current (IIH) All Pins
VIN = V3P3SYS
-1
0
+1
FA
OUTPUT LOGIC LEVELS
ILOAD = 1mA
V3P3SYS
- 0.4
ILOAD = 15mA (Note 2)
V3P3SYS
- 1.1
Digital High-Level Output Voltage (VOH)
Digital Low-Level Output Voltage (VOL)
V
ILOAD = 1mA
0
0.4
ILOAD = 15mA (Note 2)
0
0.96
V
TEMPERATURE MONITOR
TNOM (Nominal Value at 22NC)
VV3P3A = 3.3V
956
LSB
2
MAX71020
Single-Chip Electricity Meter AFE
ELECTRICAL CHARACTERISTICS (continued)
PARAMETER
CONDITIONS
Temperature Measurement Equation
Temperature Error (Note 2)
MIN
TYP
MAX
Temp = 0.33 x STEMP + 21.77
TA = -40NC to +85NC
-6
+6
TA = -20NC to +60NC
-4.8
+4.8
Duration of Temperature Measurement
TEMP_PER = 0
After Setting TEMP_START
15
UNITS
NC
NC
60
ms
4.3
mA
SUPPLY CURRENT PERFORMANCE SPECIFICATIONS
V3P3A + V3P3SYS Current (Note 2)
VV3P3A = VV3P3SYS = 3.3V, CE_E = 1,
ADC_E = 1
INTERNAL POWER-FAULT COMPARATOR SPECIFICATIONS
Overall Response Time
Falling Threshold
100mV overdrive, falling
20
200
100mV overdrive, rising
8
200
µs
3.0V comparator
2.83
2.93
3.03
2.8V comparator
2.75
2.81
2.89
V
50
136
220
mV
17
45
74
15
42
70
Difference 3.0V and 2.8V comparators
Hysteresis (Rising Threshold - Falling 3.0V comparator, TA = +22NC
Threshold)
2.8V comparator, TA = +22NC
V
mV
PLL PERFORMANCE SPECIFICATIONS
PLL Power-Up Settling Time
PLL_FAST Settling Time
PLL Lock Frequency at XOUT
VV3P3A = 0 to 3.3V step, measured from first edge
of MCK
75
VV3P3A = 3.3V, PLL_FAST rise
10
VV3P3A = 3.3V, PLL_FAST fall
10
VV3P3A = 3.3V, MCK frequency error < 1%
µs
µs
7
9.8
13
MHz
1.200
1.205
1.210
V
+1.5
mV/V
VREF PERFORMANCE SPECIFICATIONS
VREF Output Voltage, VREF (22)
TA = +22NC
VREF Power-Supply Sensitivity
(DVREF/DV3P3A)
V3P3A = 3.0V to 3.6V
-1.5
VNOM(T) = VREF(22) +
TC1(T - 22) + TC2(T - 22)2
V
VNOM Temperature Coefficient TC1
29.32 - 1.05 x TRIMT
µV/NC
VNOM Temperature Coefficient TC2
-0.56 - 0.004 x TRIMT
µV/NC2
VNOM Definition
VREF(T) Deviation from VNOM(T):
VREF(T) - VNOM(T)10 6
VNOM(T)
62
(Note 2)
-40
+40
ppm/NC
-250
+250
mV peak
ADC CONVERTER PERFORMANCE SPECIFICATIONS
Recommended Input Range
(With Respect to GNDA)
VA, VB, IBP, IBN
3
MAX71020
Single-Chip Electricity Meter AFE
ELECTRICAL CHARACTERISTICS (continued)
PARAMETER
CONDITIONS
Recommended Input Range
(With Respect to GNDA)
IAP, IAN (preamplifier enabled)
Input Impedance, No Preamplifier
fIN = 65Hz
MIN
TYP
-27.78
MAX
UNITS
+27.78 mV peak
50
ADC Gain Error vs Percentage PowerSupply Variation
VIN = 200mV peak, 65Hz
10 6 ∆Nout PK 357nV VIN
VV3P3A = 3.0V, 3.6V
100∆V3P3A 3.3
-10
100
kI
81
ppm/%
+10
mV
Input Offset
IAP = IAN = GNDA
Total Harmonic Distortion at 250mVpk
VIN = 55Hz, 250mVpk,
64kpts FFT, Blackman Harris Window
-85
dB
Total Harmonic Distortion at 20mVpk
VIN = 55Hz, 20mVpk,
64kpts FFT, Blackman Harris Window
-85
dB
FIRLEN = 15
FIRLEN =
VIN = 55Hz, 20mVpk, 64kpts FIRLEN =
LSB Size (LSB Values Do Not Include
FFT,
Blackman-Harris
the 9-Bit Left Shift at the CE Input)
FIRLEN =
window, 10MHz CKADC
FIRLEN =
Digital Full Scale
VIN = 55Hz,
10MHz CKADC
120.46
14
146.20
13
179.82
12
224.59
11
285.54
FIRLEN = 10
370.71
FIRLEN = 15
±2621440
FIRLEN = 14
±2160000
400mVpk, FIRLEN = 13
FIRLEN = 12
±1756160
FIRLEN = 11
±1105920
FIRLEN = 10
±851840
±1406080
nV
LSB
PREAMPLIFIER PERFORMANCE SPECIFICATIONS
Differential Gain,
(VIN = 28mV Differential)
TA = +25NC, VV3P3A = 3.3V, PRE_E = 1,
DIFF0_E = 1
8.9
V/V
Gain Variation vs. V3P3
(VIN = 28mV Differential)
VV3P3A = 3.0V, 3.6V
-72
ppm/%
Gain Variation vs. Temperature
(VIN = 28mV Differential) (Note 4)
TA = -40NC to +85NC
-45
ppm/NC
Differential Gain
(VIN = 15mV Differential)
4
MAX71020
Single-Chip Electricity Meter AFE
ELECTRICAL CHARACTERISTICS (continued)
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
8
mN
20
FA
Phase Shift (VIN = 28mV Differential)
TA = +25NC, VV3P3A = 3.3V
(Note 2)
0
Preamplifier Input Current (IADC0)
Preamplifier Input Current (IADC1)
PRE_E = 1, DIFF0_E = 1,
IADC0 = IADC1 = V3P3A
9
Preamplifier and ADC Total Harmonic
(VIN = 28mV Differential)
TA = +25NC; VV3P3A = 3.3V, PRE_E = 1,
DIFF0_E = 1
-80
dB
Preamplifier and ADC Total Harmonic TA = +25NC; VV3P3A = 3.3V, PRE_E = 1,
Distortion (VIN = 15mV Differential)
DIFF0_E = 1
-85
dB
15
SPI SLAVE TIMING SPECIFICATIONS
SPI Setup Time
SPI_DI to SPI_CK rise
10
ns
SPI Hold Time
SPI_CLK rise to SPI_DI
10
ns
SPI Output Delay
SPI_CLK fall to SPI_D0
SPI Recovery Time
SPI_CSZ fall to SPI_CLK
10
ns
SPI Removal Time
SPI_CLK to SPI_CSZ rise
15
ns
SPI Clock High
40
ns
SPI Clock Low
40
ns
40
SPI Clock Frequency
10
SPI Transaction Space
(SPI_CSZ Rise to SPI_CSZ Fall)
ns
MHz
1
Fs
Following power-on
1
ms
At all other times
5
RESETZ TIMING
Reset Pulse Width
Fs
Reset Pulse Rise Time (Note 2)
1
Fs
VOLTAGE MONITOR
Nominal value at +22NC (VNOM)
VV3P3A = 3.3V
Voltage Measurement Equation
130
LSB
VV3P3(CALC) = 3.29V +
(BSENSE – 130) x 0.025V +
STEMP x 242µV
Voltage Error
V
(CALC) 
100 ×  V3P3
- 1
VV3P3


-4
+4
%
Note 2: Guaranteed by design, not production tested.
Note 3:V3P3SYS and V3P3A must be connected together.
Note 4: AGND and DGND must be connected together.
5
MAX71020
Single-Chip Electricity Meter AFE
RECOMMENDED EXTERNAL COMPONENTS
NAME
FROM
TO
FUNCTION
C1
V3P3A
GNDA
CSYS
V3P3SYS
GNDD
Bypass capacitor for V3P3SYS
C1P8
VDD
GNDD
XTAL
XIN
XOUT
CXS
XIN
GNDA
CXL
XOUT
GNDA
VALUE
R 0.1 ±20%
UNITS
R 1.0 ±30%
µF
Bypass capacitor for V1P8 regulator
0.1 ±20%
µF
At cut crystal specified for 18pF load
9.8304
MHz
32 ±10%
pF
32 ±10%
pF
Bypass capacitor for 3.3V supply
Load capacitor values for crystal depend on
crystal specifications and board parasitics.
Nominal values are based on 4pF board
capacitance and include an allowance for
chip capacitance.
µF
Pin Configuration
TOP VIEW
+
VA
1
28
VB
GNDA
2
27
TEST0
V3P3A
3
26
XOUT
IBN
4
25
XIN
IBP
5
24
V3P3SYS
IAN
6
23
VDD
IAP
7
22
DIO0/WPULSE
TEST
8
21
DIO1/VPULSE
RESETZ
9
20
DIO2/XPULSE
VPP
10
19
INTZ
DIO3 / YPULSE
11
18
N.C.
GNDD
12
17
N.C.
SPI_CSZ
13
16
SPI_CLK
SPI_DO
14
15
SPI_DI
MAX71020
TSSOP
6
MAX71020
Single-Chip Electricity Meter AFE
Pin Description
(Pin types: P = Power, O = Output, I = Input, I/O = Input/Output. The circuit number denotes the equivalent circuit, as
specified under Figure 1).
PIN
NAME
TYPE
CIRCUIT
DESCRIPTION
POWER AND GROUND PINS
2
GNDA
P
—
Analog Ground. GNDA should be connected directly to the ground plane.
3
V3P3A
P
—
Analog Power Supply. A 3.3V power supply should be connected to
V3P3A. V3P3A must be the same voltage as V3P3SYS.
12
GNDD
P
—
Digital Ground. GNDD should be connected directly to the ground plane.
23
VDD
O
—
Output of the 1.8V Regulator. A 0.1µF bypass capacitor to ground
should be connected to this pin.
24
V3P3SYS
P
—
System 3.3V Supply. V3P3SYS should be connected to a 3.3V power
supply.
I
6
Differential or Single-Ended Line Current-Sense Inputs. These pins are
voltage inputs to the internal ADC. Typically, these pins are connected
to the outputs of current sensors. Unused pins must be tied to GNDA.
I
6
Line Voltage Sense Inputs. VA/VB are voltage inputs to the internal
ADC. Typically, the pins are connected to the outputs of resistordividers. Unused pins must be tied to GNDA.
8
Crystal Inputs. A 9.8304MHz crystal should be connected to XIN and
XOUT.
ANALOG PINS
7, 6
IAP, IAN
5, 4
IBP, IBN
1, 28
VA, VB
25
XIN
I
26
XOUT
O
DIGITAL PINS
22
DIO0/WPULSE
21
DIO1/VPULSE
20
DIO2/XPULSE
11
DIO3/YPULSE
8, 27
9
Multiple-Use Pins. Configurable as DIO. Alternative functions with
proper selection of associated registers are:
DIO0 = WPULSE
DIO1 = VPULSE
I/O
3, 4
TEST, TEST0
I
3
Connect to GNDD
RESETZ
I
3
Active-Low Reset
13
SPI_CSZ
I
3
14
SPI_DO
O
4
15
SPI_DI
I
3
16
SPI_CLK
I
3
19
INTZ
O
4
Active-Low Interrupt Request
VPP
I
—
Connect to GNDD
SPI Interface
OTHER PIN
10
7
MAX71020
Single-Chip Electricity Meter AFE
V3P3SYS
V3P3SYS
DIGITAL
INPUT PIN
CMOS
INPUT
ANALOG
INPUT PIN
GNDA
GNDD
DIGITAL INPUT EQUIVALENT CIRCUIT
TYPE 3
V3P3SYS
TO MUX
ANALOG INPUT EQUIVALENT CIRCUIT
TYPE 6:
ADC INPUT
V3P3SYS
V3P3SYS
DIGITAL
OUPUT PIN
CMOS
OUTPUT
GNDD
GNDA
GNDD
DIGITAL OUTPUT EQUIVALENT CIRCUIT
TYPE 4
TO
OSCILLATOR
OSCILLATOR
PIN
GNDA
OSCILLATOR EQUIVALENT CIRCUIT
TYPE 8:
OSCILLATOR I/O
Figure 1. I/O Equivalent Circuits
8
MAX71020
Single-Chip Electricity Meter AFE
Functional Block Diagram
GNDA
V3P3A
IAP
MAX71020
IAN
IBP
IBN
DC
MODULATOR
INPUT
MULTIPLEXER
PREAMPLIFIER
FIR
DECIMATOR
VB
VA
VREF
VREF
MULTIPLEXER
CONTROL
XIN
XOUT
V3P3SYS
CRYSTAL
OSCILLATOR
9.83MHz
MASTER
CLOCK
PLL
VOLTAGE
REGULATOR
MCK
VDD
CKADC (10MHz, 5MHz, 2.5MHz, 1.25MHz)
CLOCK
GENERATOR
GNDD
1.8V TO
LOGIC
SPI_CSZ
CKCE
20MHz, 5MHz
MUX_SYNC
SPI_CLK
VSTAT
VPULSE
2
XPULSE
VSTAT
PARITY
ERR
XFER_BUSY
WPULSE
V3P3A
POWER
STATUS
SPI_DO
START
CE
32-BIT
COMPUTE
ENGINE
TEMP
SENSE
VREF
SPI_DI
SPI
YPULSE
2
INTZ
INTZ
D10_WPULSE
PULSE
CONTROL
D11_VPULSE
IO_CTRL
D12_XPULSE
D13_YPULSE
RESETZ
9
MAX71020
Single-Chip Electricity Meter AFE
Hardware Description
Hardware Overview
The MAX71020 energy meter analog front-end (AFE)
integrates all primary functional blocks required to implement a solid-state residential electricity meter. Included
on the chip are:
● An analog front-end (AFE) featuring a 22-bit secondorder sigma-delta ADC
● An independent 32-bit digital computation engine
(CE) to implement DSP functions
● A precision voltage reference (VREF)
● A temperature sensor for digital temperature
compensation
● Four I/O pins
● A zero-crossing interrupt
● Resistive shunt and current transformers
are supported
● A SPI slave for connection to a host microcontroller
In a typical application, the 32-bit compute engine (CE)
of the MAX71020 sequentially processes the samples
from the voltage inputs on analog input pinsand performs
calculations to measure active energy (Wh) and reactive
energy (VARh), as well as A2h, and V2h for four-quadrant
metering. These measurements are then accessed by
the host microcontroller.
In addition to the temperature-trimmed ultra-precision
voltage reference, the on-chip digital temperature compensation mechanism includes a temperature sensor
and associated controls for correction of unwanted
temperature effects on measurement, e.g., to meet the
requirements of ANSI and IEC standards.
Temperature-dependent external components such as
crystal oscillator, resistive shunts, current transformers
(CTs) and their corresponding signal conditioning circuits
can be characterized and their correction factors can be
programmed to produce electricity meters with exceptional accuracy over the industrial temperature range.
Communications with the host is conducted over a SPI
interface. The communications protocol between the host
and the MAX71020 provides a redundant information
transfer ensuring the correctness of commands transferred from the host to the AFE, and of data transferred
from the AFE to the host.
In addition, the MAX71020 has one pin dedicated as an
interrupt output to the host. In this way, the MAX71020
notifies the host of asynchronous events.
Analog Section
Signal Input Pins
The MAX71020 has four analog inputs: two single-ended
inputs for voltage measurement, and two differential
inputs for current measurement.
IAP, IAN, IBP, and IBN pins are current sensor inputs.
The differential inputs feature preamplifiers with a selectable gain of 1 or 9, and are intended for direct connection
to a shunt resistor sensor or a current transformer (CT).
The voltage inputs in the MAX71020 are single-ended,
and are intended for sensing the line voltage. These
single-ended inputs are referenced to the GNDA pin.
All analog signal input pins measure voltage. In the
case of shunt current sensors, currents are sensed as a
voltage drop in the shunt resistor sensor. In the case of
Current Transformers (CT), the current is measured as a
voltage across a burden resistor that is connected to the
secondary winding of the CT. Meanwhile, line voltages
are sensed through resistive voltage-dividers. Voltage
inputs are single-ended and their common return is the
GNDA pin.
Some versions of the device implement a preamplifier
with a fixed gain of 9 to enhance performance when
using sensors with a low-amplitude output (for example,
current shunts). When using a device with the preamplifier enabled, you must ensure that the input amplitude is
no greater than 27.78mV peak.
Input Multiplexer
The input multiplexer sequentially applies the input signals
from the analog input pins to the input of the ADC. One
complete sampling sequence is called a multiplexer frame.
The IBP-IBN differential input may be used to sense the
neutral current, and VB may be optionally used to sense
a second voltage channel.This configuration implies that
the multiplexer applies a total of four inputs to the ADC.
For this configuration, the multiplexer sequence is as
shown in Figure 1. In this configuration IAP-IAN, IBP-IBN,
VA and VB are sampled. The physical current sensor for
the neutral current measurement and the voltage sensor
for VB may be omitted if not required.
10
MAX71020
Single-Chip Electricity Meter AFE
For a standard single-phase application with tamper sensor in the neutral path, two current inputs are configured for
differential mode, using the pin pairs IAP-IAN and IBP-IBN.
In the MAX71020, the system uses two locally connected
current sensors via IAP-IAN and IBP-IBN and configured
as differential inputs. The VA pin is typically connected to
the phase voltage via resistor-dividers.
The MAX71020 adds the ability to sample a second
phase voltage (applied at the VB pin), which makes it
suitable for meters with two voltage and two current sensors, such as meters implementing Equation 2 for dualphase operation (P = VA x IA + VB x IB).
Table 1 summarizes the AFE input configuration.
Delay Compensation
When measuring the energy of a phase (i.e., Wh and
VARh) in a service, the voltage and current for that phase
must be sampled at the same instant. Otherwise, the
phase difference, φ, introduces errors.
=
φ
t delay
T

× 360
=
t delay × f × 360 
where f is the frequency of the input signal, T = 1/f and
tDELAY is the sampling delay between current and voltage.
Table 1. ADC Input Configuration
PIN
IAP
IAN
IBP
IBN
COMMENT
The ADC results are stored in register IA.
The ADC result is stored in register VA.
VB
The ADC result is stored in register VB.
The constant delay allpass filter provides a broadband
delay 360N - θ, which is precisely matched to the difference in sample time between the voltage and the current
of a given phase. This digital filter does not affect the
amplitude of the signal, but provides a precisely controlled phase response.
The ADC multiplexer samples the current first, immediately followed by sampling of the corresponding phase
voltage, thus the voltage is delayed by a phase angle
φ relative to the current. The delay compensation implemented in the CE aligns the voltage samples with their
corresponding current samples by first delaying the current samples by one full sample interval (i.e., 360N), then
routing the voltage samples through the allpass filter, thus
delaying the voltage samples by 360N - θ, resulting in the
residual phase error between the current and its corresponding voltage of θ - φ. The residual phase error is negligible, and is typically less than ±0.0015N at 100Hz, thus it
does not contribute to errors in the energy measurements.
ADC Preamplifier
The ADC preamplifier is a low-noise differential amplifier
with a fixed gain of 9 available on the IAP and IAN currentsensor input pins. It is provided only in versions of the
MAX71020 AFE configured for use with current shunts.
The ADC results are stored in register IB.
VA
Traditionally, sampling is accomplished by using two
ADCs per phase (one for voltage and the other one for
current) controlled to sample simultaneously. Maxim’s
Teridian™ Single-Converter Technology®, however,
exploits the 32-bit signal processing capability of its CE
to implement “constant delay” allpass filters. The allpass
filter corrects for the conversion time difference between
the voltage and the corresponding current samples that
are obtained with a single multiplexed ADC.
MULTIPLEXER FRAME
MUX DIV = 4 CONVERSIONS
SETTLE
CK32
MUX STATE
S
0
1
2
3
IA
VA
IB
VB
S
0
CROSS
MUX_SYNC
Figure 2. States in a Multiplexer Frame
Teridian is a trademark and Single Converter Technology is a registered trademark of Maxim Integrated Products, Inc.
11
MAX71020
Single-Chip Electricity Meter AFE
Analog-to-Digital Converter (ADC)
A single second-order delta-sigma ADC digitizes the
voltage and current inputs to the device. The resolution
of the ADC is dependent on several factors.
● Monitoring of the input signal amplitude (for sag
detection)
Initiation of each ADC conversion is automatically controlled by logic internal to the MAX71020. At the end of
each ADC conversion, the FIR filter output data is stored
into the register determined by the multiplexer selection.
FIR data is stored LSB justified, but shifted left 9 bits.
● Scaling of samples based on temperature compensation information
● Scaling of the processed samples based on calibration coefficients
● Gain and phase compensation
FIR Filter
The finite impulse response filter is an integral part of the
ADC and it is optimized for use with the multiplexer. The
purpose of the FIR filter is to decimate the ADC output to
the desired resolution. At the end of each ADC conversion, the output data is stored into the register determined by the multiplexer selection.
Meter Equations
The MAX71020 provides hardware assistance to the CE
in order to support various meter equations. This assistance is controlled through register EQU[2:0] (equation
assist). The Compute Engine (CE) firmware implements
the equations listed in Table 2. EQU[2:0] specifies the
equation to be used based on the meter configuration
and on the number of phases used for metering.
Voltage References
A bandgap circuit provides the reference voltage to
the ADC. Since the VREF bandgap amplifier is chopper
stabilized, the DC offset voltage, which is the most significant long-term drift mechanism in the voltage references
(VREF), is automatically removed by the chopper circuit.
Pulse Generators
The MAX71020 provides up to four pulse generators,
VPULSE, WPULSE, XPULSE, and YPULSE, as well as
hardware support for the VPULSE and WPULSE pulse
generators. The pulse generators are used to output CE
status indicators and energy usage.
Digital Computation Engine (CE)
The CE, a dedicated 32-bit signal processor, performs
the precision computations necessary to accurately measure energy. The CE calculations and processes include:
● Multiplication of each current sample with its associated voltage sample to obtain the energy per sample
(when multiplied with the constant sample time)
● Frequency-insensitive delay cancellation on all four
channels (to compensate for the delay between
samples caused by the multiplexing scheme)
● 90° phase shifter (for VAR calculations)
● Pulse generation
● Monitoring of the input signal frequency (for frequency
and phase information)
The polarity of the pulses may be inverted with control bit
PLS_INV. When this bit is set, the pulses are active-high,
rather than the more usual active-low. PLS_INV inverts all
four pulse outputs.
The function of each pulse generator is determined by
the CE code. The MAX71020 provides a mains zerocrossing indication on XPULSE and voltage sag detection on YPULSE.
A common use of the zero-crossing pulses is to generate
interrupt in order to drive RTC software in places where
the mains frequency is sufficiently accurate to do so and
also to adjust for crystal aging. A common use for the
SAG pulse is to generate an interrupt that alerts the host
processor when mains power is about to fail, so that the
host processor can store accumulated energy and other
data to EEPROM before the supply voltage actually drops.
Table 2. Inputs Selected in Multiplexer Cycles
EQU
DESCRIPTION
0
1 element, 2W, 1j with neutral current sense
1
1 element, 3-W, 1j
2
2 element, 3-W
Wh and VARh FORMULA
ELEMENT 0
ELEMENT 1
VA ∙ IA
VA ∙ IB
VA(IA-IB)/2
VA ∙ IB/2
VA ∙ IA
VB ∙ IB
12
MAX71020
Single-Chip Electricity Meter AFE
Table 3. Pulse Output Function Assignments
OUTPUT
FUNCTION
XPULSE
Pulse output on each zero crossing on voltage input
YPULSE
Pulse output when voltage sag detected
VPULSE
Pulse output when programmed VARh consumption has occurred
WPULSE
Pulse output when programmed Wh consumption has occurred
XPULSE and YPULSE
Pulses generated by the CE may be exported to the
XPULSE and YPULSE pulse output pins. Pins D2 and D3
are used for these pulses, respectively. The XPULSE and
YPULSE outputs can be updated once on each pass of
the CE code. See the CE Interface Description section
for details.
VPULSE and WPULSE
By default, WPULSE and VPULSE are negative pulses
(i.e., low level pulses, designed to sink current through
an LED). PLS_MAXWIDTH[7:0] determines the maximum
negative pulse width TMAX in units of CK_FIR clock
cycles based on the pulse interval TI according to the
formula:
TMAX = (2 x PLS_MAXWIDTH[7:0] + 1) x TI
TI is based on an internal value that determines the pulse
interval and the ADC clock, both of which are determined
by the particular characteristics of the compute engine.
In the MAX71020, the default value for TI is 65.772µs, but
this value changes in customized versions of this part.
If PLS_MAXWIDTH = 255 no pulse-width checking is performed, and the pulses default to 50% duty cycle. TMAX
is typically programmed to 10ms (TMAX = 76), which
works well with most calibration systems.
The polarity of the pulses may be inverted with the control
bit PLS_INV. When PLS_INV is set, the pulses are activehigh. The default value for PLS_INV is zero, which selects
active-low pulses.
Temperature Sensor
The MAX71020 includes an on-chip temperature sensor for determining the temperature of its bandgap
reference. The primary use of the temperature data is to
determine the magnitude of compensation required to
offset the thermal drift in the system for the compensation
of current, voltage, and energy measurement. See the
Metrology Temperature Compensation section.
The temperature sensor is awakened on command from
the host microcontroller by setting the TEMP_START
control bit. The host microcontroller must wait for the
TEMP_START bit to clear before reading STEMP[15:0]
and before setting the TEMP_START bit once again.
The result of the temperature measurement can be read
from the STEMP[15:0] register. The 16-bit value is in
two’s complement form and ranges from -1024 to +1023
(decimal). The sensed temperature can be computed
from the 16-bit STEMP[15:0] reading using the following
formula:
Temp (NC) = 0.325 x STEMP + 22
An additional register, VSENSE[7:0], senses the level
of supply voltage. Table 4 shows the registers used for
temperature measurement.
Digital I/O
On reset or power-up, all DIO pins are configured as
high-impedance. DIO pins can be configured independently by the host microcontroller by manipulating the
D0, D1, D2, and D3 bit fields.
The WPULSE and VPULSE pulse generator outputs are
available on pins D0/WPULSE and D1/VPULSE, respectively.
Table 4. Temperature Measurement Registers
NAME
RST
WK
DIR
TBYTE_BUSY
0
0
R
DESCRIPTION
Indicates that hardware is still writing the result. Additional
writes to this byte are locked out while it is one. Write duration
could be as long as 6ms.
13
MAX71020
Single-Chip Electricity Meter AFE
Table 4. Temperature Measurement Registers (continued)
NAME
RST
WK
DIR
DESCRIPTION
Sets the period between temperature measurements
TEMP_PER
TEMP_PER[1:0]
0
—
R/W
TIME
0
Manual updates (see TEMP_START
description)
1
Every accumulation cycle
2
Continuous
TEMP_PER[1:0] must be zero in order for TEMP_START to
function. If TEMP_PER[1:0] = 0, then setting TEMP_START
starts a temperature measurement. Hardware clears
TEMP_START when the temperature measurement is
complete. The host microcontroller must wait for TEMP_START
to clear before reading STEMP[10:0] and before setting
TEMP_START again.
TEMP_START
0
—
R/W
STEMP[15:0]
—
—
R
The result of the temperature measurement
VSENSE[7:0]
—
—
R
The result of voltage sense reading:
V3P3SYS = VSENSE[7:0]/42.7
SPI Slave Port
The slave SPI port communicates directly with the host
microcontroller and allows it to read and write the device
control registers. The interface to the slave port consists
of the SPI_CSZ, SPI_CLK, SPI_DI, and SPI_DO pins.
SPI Transactions
SPI transactions are configured to provide immunity to
electrical noise through redundancy in the command
segment and error checking in the data field. The
MAX71020 SPI transaction is exactly 64 bits; transactions
of any other length are rejected. Each SPI transaction has
the following fields:
● A 24-bit setting packet, consisting of

11-bit address, MSB first

1-bit direction (1 means read)

11-bit inverted address, MSB first

1-bit inverted direction
● An 8-bit status, consisting of the following bits
concerning the last transaction, starting from bit 7:

11-bit address, MSB

Parity of the status byte (0 or 1 could be correct)

FIFO overflow status bit (1 means error)

FIFO underrun status bit (1 means error)

Read or write data parity (0 or 1 could be correct)
(never both read and write; address is not included
in the parity)

Address or direction mismatch error bit
(1 means error)

Result of the SPI_CSZ glitch detector
(1 means error)

A bit indicating whether or not the bit count was
exactly 64 (1 means error).

Out of bounds address, most likely due to SPI
safe bit or the memory manager (1 means error).
● A 32-bit packet of data, MSB first

If extra clocks are provided at the end during a
read, all zero is output and the status will continue
to be updated, signaling an error.

If extra clocks are provided at the end during a
write, the write will be aborted and the status
will be updated to signal an error.
● None of the fields above are optional.
● If an error is detected during the address or direction
phase, no action will be taken.
● SPI_DO is high-Z while SPI_CSZ is high.
● SPI safe mode will be supported, and SPI will not be
locked out of this bit during SPI safe.
A typical SPI transaction is as follows. While SPI_CSZ
is high, the port is held in an initialized/reset state.
During this state, SPI_DO is held in high-Z state and all
transitions on SPI_CLK and SPI_DI are ignored. When
SPI_CSZ falls, the port will begin the transaction on
the first rising edge of SPI_CLK. As shown in Table 5,
a transaction consists of a 24-bit setting field, an 8-bit
14
MAX71020
Single-Chip Electricity Meter AFE
Table 5. SPI Transaction (64 Bits)
24-BIT SETTING FIELD
Address
Dir
8-BIT STATUS
32-BIT DATA
Status from Previous Transaction: status[7:0]
Data
Status
FIFO
FIFO
Data
Setting
CSB
Bad
Bad
Parity OverRun UnderRun Parity Mismatch Glitch CK Cnt Address
data[31:0]
Inv Address Inv Dir
addr[10:0] RD addr_b[10:0] RD_b
SERIAL READ
11-BIT ADDRESS
RD
11-BIT INVERTED
ADDRESS
STATUS BYTE
RD
DATA [ADDR]
(FROM HOST) SPI_CSZ
0
(FROM HOST) SPI_CLK
A10
(FROM HOST) SPI_DI
A9
A1
(FROM AM48) SPI_DO
SERIAL WRITE
10
11
A0
HI-Z
RD
11-BIT ADDRESS
A10
22
23
A0
RD
A9
24
31
11-BIT INVERTED
ADDRESS
47
48
63
X
ST7 ST6
RD
32
RD
ST0 D31 D30
D16 D15 D14 D13
STATUS BYTE
D1
D0
DATA [ADDR]
(FROM HOST) SPI_CSZ
0
(FROM HOST) SPI_CLK
(FROM HOST) SPI_DI
X
A10
A9
A1
(FROM AM48) SPI_DO
10
11
A0
HI-Z
RD
A10
A9
22
23
A0
RD
24
ST7 ST6
31
32
47
48
D31 D30
D16 D15 D14 D13
63
D1
D0
X
ST0
Figure 3. SPI Slave Port—Typical READ and WRITE operations
status, and a 32-bit data word. The transaction ends
when SPI_CSZ is raised.
Assuming phase angles are constant, the following formulae apply:
Note that the status byte indicates the status of the previous SPI transaction except for the status byte parity.
P = Real Energy [Wh] = V x A x cos φ x t
SPI Safe Mode
Sometimes it is desirable to prevent the SPI interface
from writing to arbitrary registers and possibly disturbing
the CE operation. For this reason, the SPI_SAFE mode is
created. In this mode, all SPI writes are disabled except
to the word containing the SPI_SAFE bit. This affords the
host one more layer of protection from inadvertent writes.
S = Apparent Energy [VAh] =
Functional Description
Theory of Operation
The energy delivered by a power source into a load can
be expressed as:
t
E = ∫ V(t)I(t)dt
0
Q = Reactive Energy [VARh] = V x A x sin φ x t
P 2 + Q2
For a practical meter, not only voltage and current amplitudes, but also phase angles and harmonic content may
constantly change. Thus, simple RMS measurements are
inherently inaccurate. A modern solid-state electricity
meter IC such as the MAX71020 functions by emulating
the integral operation above, i.e., it processes current
and voltage samples through an ADC at a constant frequency. As long as the ADC resolution is high enough
and the sample frequency is beyond the harmonic range
of interest, the current and voltage samples, multiplied
with the time period of sampling yield an accurate quantity for the momentary energy. Summing the instantaneous energy quantities over time provides very accurate
results for accumulated energy.
15
MAX71020
Single-Chip Electricity Meter AFE
voltage. The following discussion assumes that V3P3A
and V3P3SYS are connected together at the PCB level.
500
During a power failure, as V3P3A falls, two thresholds
are detected. The first threshold, at 3.0V, warns the host
microcontroller that the analog modules are no longer
accurate. The second threshold, at 2.8V, warns the host
microcontroller that a serious reduction in supply voltage
has occurred. OTP reads may be affected.
400
300
200
100
0
-100
-200
CURRENT [A]
VOLTAGE [V]
ENERGY PER INTERVAL [Ws]
ACCUMULATED ENERGY [Ws]
-300
-400
-500
0
5
10
15
20
Figure 4. Voltage, Current, Momentary and Accumulated Energy
Figure 4 shows the shapes of V(t), I(t), the instantaneous
power and the accumulated energy resulting from 50
samples of the voltage and current signals over a period
of 20ms. The application of 240VAC and 100A results in
an accumulation of 480Ws (= 0.133Wh) over the 20ms
period, as indicated by the accumulated power curve. The
described sampling method works reliably, even in the
presence of dynamic phase shift and harmonic distortion.
Fault and Reset Behavior
Events at Power-Down
Power fault detection is performed by internal comparators that monitor the voltage at the V3P3A pin and
also monitor the internally generated VDD pin voltage
(1.8VDC). V3P3SYS and V3P3A must be connected
together at the PCB level, so that the comparators, which
are internally connected only to the V3P3A, are able to
simultaneously monitor the common V3P3SYS and V3P3A
Reset Sequence
When the MAX71020 receives a reset signal, either from
the RESETZ pin or from the SPI, it asynchronously halts
what it was doing. It then clears RAM and initializes configuration bits. An errant RESET can occur during an ESD
event. If this happens, the host must be notified. This is
accomplished by holding the INTZ output low until the
host clears it.
Applications Information
Sensor Connection
Figure 5 to Figure 8 show voltage-sensing resistive dividers, current-sensing current transformers (CTs) and current-sensing resistive shunts and how they are connected to the voltage and current inputs of the MAX71020. All
input signals to the MAX71020 sensor inputs are voltage
signals providing a scaled representation of either a
sensed voltage or current.
The analog input pins of the MAX71020 are
designed for sensors with low source impedance. RC filters with resistance values higher
than those implemented in the demo boards
must not be used. Refer to the demo board schematics
for complete sensor input circuits and corresponding
component values.
Table 6. VSTAT[1:0]
VSTAT[1:0]
00
DESCRIPTION
01
System Power-OK. VV3P3A > 3.0V. Analog modules are functional and accurate.
System Power is low. 2.8V < VV3P3A < 3.0V. Analog modules not accurate.
11
System power below 2.8V. Ability to monitor power is about to fail.
16
MAX71020
Single-Chip Electricity Meter AFE
RIN
VA
VIN
ROUT
GNDA
Figure 5. Resistive Voltage-Divider (Voltage Sensing)
IIN
IOUT
IAP
RBURDEN
CT
VOUT
GNDA
NOISE FILTER
1:N
Figure 6. CT With Single-Ended Input Connection (Current Sensing)
IIN
IOUT
IAP
GNDA
CT
RBURDEN
VOUT
IAN
BIAS NETWORK AND NOISE FILTER
1:N
Figure 7. CT With Differential Input Connection (Current Sensing)
IAP
GNDA
RSHUNT
VOUT
IAN
BIAS NETWORK AND NOISE FILTER
Figure 8. Differential Resistive Shunt Connections (Current Sensing)
17
MAX71020
Single-Chip Electricity Meter AFE
Connecting the MAX71020
configuration implements a single-phase measurement
with tamper-detection using one current sensor to measure the neutral current. This configuration can also be
used to create a split phase meter (e.g., ANSI Form 2S).
Figure 9 shows a typical MAX71020 configuration. The
IAP-IAN current channel may be directly connected to
either a shunt resistor or a CT, while the IBP-IBN channel is connected to a CT and is therefore isolated. This
CT
NEUTRAL
CT OR
LINE
LOAD
NOTE: THIS SYSTEM IS REFERENCED TO LINE
SHUNT
NEUTRAL
POWER SUPPLY
LINE
MUX AND ADC
V3P3A
V3P3SYS
GNDA
GNDD
IAP
RESISTORDIVIDER
IAN
LINE
MAX71020
VA
REGULATOR
VB
IBP
TEMPERATURE
SENSOR
IBN
VREF
RAM
COMPUTE
ENGINE
POWER-FAULT
COMPARATOR
PULSE /AUX
RESETZ
INTZ
HOST
OSCILLATOR/PLL
XIN
SPI
INTERFACE
9.8304MHz
XOUT
Figure 9. Connecting the MAX71020
18
MAX71020
Single-Chip Electricity Meter AFE
Metrology Temperature Compensation
Voltage Reference Precision
Since the VREF bandgap amplifier is chopper-stabilized
the DC offset voltage, which is the most significant longterm drift mechanism in the voltage references, is automatically removed by the chopper circuit. Maxim trims
the VREF voltage reference during the device manufacturing process to ensure the best possible accuracy.
The reference voltage (VREF) is trimmed to a target
value of 1.205V nominal. During this trimming process,
the TRIMT[7:0] value is stored in nonvolatile fuses.
TRIMT[7:0] is trimmed to a value that results in minimum
VREF variation with temperature.
The TRIMT[7:0] value can be read by the host microcontroller during initialization to calculate parabolic temperature compensation coefficients suitable for each
individual device. The resulting temperature coefficient
for VREF is ±40ppm/°C.
Considering the factory calibration temperature of VREF
to be +22°C and the industrial temperature range (-40°C
to +85°C), the VREF error at temperature extremes can
be calculated as:
(85°C - 22°C) x 40ppm/°C = +2520ppm = +1.252%
and
(-40°C - 22°C) x 40ppm/°C = +2480ppm = -0.248%
The above calculation implies that both the voltage and
the current measurements are individually subject to a
theoretical maximum error of approximately ±0.25%.
When the voltage sample and current sample are multiplied together to obtain the energy per sample, the
voltage error and current error combine resulting in
approximately ±0.5% maximum energy measurement
error. However, this theoretical ±0.5% error considers
only the voltage reference (VREF) as an error source.
In practice, other error sources exist in the system. The
principal remaining error sources are the current sensors
(shunts or CTs) and their corresponding signal conditioning circuits, and the resistor voltage-divider used to
measure the voltage. The 0.5% grade devices should be
used in class 1% designs, allowing sufficient margin for
the other error sources in the system.
Crystal Oscillator
The oscillator drives an AT cut microprocessor crystal at
a frequency of 9.8304MHz. Board layouts with minimum
capacitance from XIN to XOUT require less current.
Good layouts have XIN and XOUT shielded from each
other and from digital signals.
Since the oscillator is self-biasing, an external
resistor must not be connected across the
crystal.
Meter Calibration
Once the MAX71020 energy meter device has been
installed in a meter system, it must be calibrated. A complete calibration includes the following:
● Establishment of the reference temperature (e.g., typically 22NC).
● Calibration of the metrology section, i.e., calibration
for tolerances of the current sensors, voltage-dividers,
and signal conditioning components as well as of the
internal reference voltage (VREF) at the reference
temperature (e.g., typically 22NC).
The metrology section can be calibrated using the gain
and phase adjustment factors accessible to the CE. The
gain adjust­ment is used to compensate for tolerances of
components used for signal conditioning, especially the
resistive components. Phase adjustment is provided to
compensate for phase shifts introduced by the current
sensors or by the effects of reactive power supplies.
The MAX71020 supports common industry-standard calibration techniques, such as single-point (energy-only)
and multipoint (energy, VRMS, IRMS).
19
MAX71020
Single-Chip Electricity Meter AFE
Host Microcontroller Interface
Register Map
Table 7. Register Map
NAME
BYTE
R/W
ADDRESS
DEFAULT
VALUE
DESCRIPTION
CAL_IA
0x010
R/W
0x0000 4000
Calibration constant for current channel A. Unity gain = 0x0000 4000.
CAL_VA
0x011
R/W
0x0000 4000
Calibration constant for current channel B. Unity gain = 0x0000 4000.
ADJ_A
0x012
R/W
0x0000 0000
—
CAL_IB
0x013
R/W
0x0000 4000
Calibration constant for voltage channel A. Unity gain = 0x0000 4000.
CAL_VB
0x014
R/W
0x0000 4000
Calibration constant for voltage channel B. Unity gain = 0x0000 4000.
ADJ_B
0x015
R/W
0x0000 0000
—
Configures internal CE operation
CECONFIG
0x020
R/W
WRATE
0x021
R/W
0x0030 DB00
0x0000 0223
BIT
NAME
DESCRIPTION
0
PULSE_SLOW
Reduces pulse output rate by a factor of 64. Must
not be used with PULSE_FAST.
1
PULSE_FAST
Increases pulse output rate by a factor of 16.
Must not be used with PULSE_SLOW.
5:2
Reserved
—
6
FREQSEL
Select phase for frequency measurement: 0 = A,
1=B
7
Reserved
—
19:8
SAG_CNT
Number of consecutive voltage samples below
SAG_THR before a sag event is declared
20
SAG_INT
Enable sag detect output on YPULSE
21
EDGE_INT
Enable zero-crossing output on XPULSE
31:22
Reserved
—
Sets meter constant for pulse outputs. See the Pulse Generation section.
KVAR
0x022
R/W
0x0000 192C Scale factor for VAR measurements
SAG_THR
0x024
R/W
0x016C AF60 Voltage threshold for sag warnings. See the CE Status and Control section.
QUANT_VA
0x025
R/W
0x0000 0000
Truncation/noise compensation for voltage phase A
QUANT_IA
0x026
R/W
0x0000 0000
Truncation/noise compensation for current phase A
QUANT_A
0x027
R/W
0x0000 0000
Truncation/noise compensation for real power phase A
QUANT_VARA
0x028
R/W
0x0000 0000
Truncation/noise compensation for reactive power phase A
QUANT_VB
0x029
R/W
0x0000 0000
Truncation/noise compensation for voltage phase B
QUANT_IB
0x02A
R/W
0x0000 0000
Truncation/noise compensation for current phase B
QUANT_B
0x02B
R/W
0x0000 0000
Truncation/noise compensation for real power phase B
QUANT_VARB
0x02C
R/W
0x0000 0000
Truncation/noise compensation for reactive power phase B
GAIN_ADJ0
0x040
R/W
0x0000 4000
Scale value for voltage inputs VA and VB. Default value of 16,384 is unity gain.
20
MAX71020
Single-Chip Electricity Meter AFE
Table 7. Register Map (continued)
NAME
BYTE
R/W
ADDRESS
DEFAULT
VALUE
DESCRIPTION
GAIN_ADJ1
0x041
R/W
0x0000 4000
Scale value for current input IA. Default value of 16,384 is unity gain.
Scale value for current input IB. Default value of 16,384 is unity gain.
GAIN_ADJ2
0x042
R/W
0x0000 4000
WPULSE_CTR
0x045
R
—
Pulse generator counter (real power)
WPULSE_FRAC
0x046
R
—
Pulse generator numerator (real power)
WSUM_ACCUM
0x047
R
—
Pulse generator rollover accumulator (real power)
VPULSE_CTR
0x049
R
—
Pulse generator counter (reactive power)
VPULSE_FRAC
0x04A
R
—
Pulse generator numerator (reactive power)
VSUM_ACCUM
0x04B
R
—
Pulse generator rollover accumulator (reactive power)
Status of the Compute Engine
CESTATUS
0x080
R
—-
BIT
NAME
0
SAG_A
Sag status, voltage phase A
1
SAG_B
Sag status, voltage phase B
2
Reserved
3
F0
31:4
Reserved
DESCRIPTION
—Square wave at exact line frequency
—-
FREQ_X
0x082
R
—
Fundamental line frequency in units of (2520.6 x 2-32)Hz
MAINEDGE_X
0x083
R
—
Number of zero crossings of either direction during previous accumulation
period
WSUM_X
0x084
R
—
Signed sum of real energy from both wattmeter elements
W0SUM_X
0x085
R
—
Real energy from wattmeter element 0
W1SUM_X
0x086
R
—
Real energy from wattmeter element 1
VARSUM_X
0x088
R
—
Signed sum of reactive energy from both wattmeter elements
VAR0SUM_X
0x089
R
—
Reactive energy from wattmeter element 0
VAR1SUM_X
0x08A
R
—
Reactive energy from wattmeter element 1
I0SQSUM_X
0x08C
R
—
Sum of squared samples from current sensor 0
I1SQSUM_X
0x08D
R
—
Sum of squared samples from current sensor 1
V0SQSUM_X
0x090
R
—
Sum of squared samples from voltage sensor 0
V1SQSUM_X
0x091
R
—
Sum of squared samples from voltage sensor 1
IA
0x100
R
—
Most recent result of ADC conversion for current channel A
IB
0x102
R
—
Most recent result of ADC conversion for current channel B
VB
0x109
R
—
Most recent result of ADC conversion for voltage channel B
VA
0x10A
R
—
Most recent result of ADC conversion for voltage channel A
21
MAX71020
Single-Chip Electricity Meter AFE
Table 7. Register Map (continued)
NAME
BYTE
R/W
ADDRESS
DEFAULT
VALUE
DESCRIPTION
Contains identifying information for the device
DEVICEID
0x301
R
0x0000 1100
BIT
NAME
7:0
Reserved
—
DESCRIPTION
15:8
VERSION
Version index. Currently, on 0x11 is defined as die
type AM48A0A.
31:16
CHIP_ID
Family tag and feature tag of the device, currently
0x0000
STEMP
0x30A
R
—
Result of the temperature measurement. Only bits 26:16 are significant; all
other bits return zero.
BSENSE
0x30B
R
—
Result of the device VDD measurement. Only bits 23:16 are significant; all
other bits return zero.
22
MAX71020
Single-Chip Electricity Meter AFE
Table 7. Register Map (continued)
NAME
BYTE
R/W
ADDRESS
DEFAULT
VALUE
DESCRIPTION
Contains the characteristics of the four digital I/O pins
IOCFG
0x30C
R/W
BIT
NAME
DESCRIPTION
0
DI0
Reflects logic state on DIO0
1
DI1
Reflects logic state on DIO1
2
DI2
Reflects logic state on DIO2
Reflects logic state on DIO3
3
DI3
7:4
Reserved
8
D_OD0
Configures DIO0 as open drain if configured as output
9
D_OD1
Configures DIO1 as open drain if configured as output
10
D_OD2
Configures DIO2 as open drain if configured as output
11
D_OD3
Configures DIO3 as open drain if configured as output
15:12
Reserved
—
—
DO
Configures DIO0.
00: Hi-Z
01: WPULSE
10: Logic 1
11: Logic 0
D1
Configures DIO1.
00: Hi-Z
01: VPULSE
10: Logic 1
11: Logic 0
D2
Configures DIO2.
00: Hi-Z
01: XPULSE
10: XFER_BUSY
11: Logic 0
23:22
D3
Configures DIO3.
00: Hi-Z
01: YPULSE
10: CE_BUSY
11: Logic
31:24
Reserved
0x0000 0F00 17:16
19:18
21:20
—
Configures hardware aspects of the AFE
METER_CFG
0x30D
R/W
0xFF00 0080
BIT
NAME
DESCRIPTION
14:0
Reserved
—
15
PLS_INV
Force meter pulses to be positive-going rather than
negative-going
23:16
Reserved
—
31:24 PLS_MAXWID Determines the maximum width of a meter pulse
23
MAX71020
Single-Chip Electricity Meter AFE
Table 7. Register Map (continued)
NAME
BYTE
R/W
ADDRESS
DEFAULT
VALUE
DESCRIPTION
Interrupt configuration register: configure the behavior of the INTZ pin
INT_CFG
0x30F
R/W
0x0000 8000
BIT
NAME
DESCRIPTION
0
IE_WPULSE
Enables an interrupt to occur on the leading
edge of WPULSE
1
IE_VPULSE
Enables an interrupt to occur on the leading
edge of VPULSE
2
IE_YPULSE
Enables an interrupt to occur on the leading
edge of YPULSE
3
IE_XPULSE
Enables an interrupt to occur on the leading
edge of XPULSE
4
IE_XDATA
Enables an interrupt to occur at the conclusion
of the accumulation interval, indicating that fresh
data is available
5
IE_CEBUSY
6
Reserved
—
7
IE_VSTAT
Enables an interrupt to occur when the VSYS
status changes
11:8
INT_POL
Interrupt polarity for the PULSE edges. The
default polarity is falling edge.
INT_POL[3]=1: Interrupt on rising edge of
YPULSE
INT_POL[2]=1: Interrupt on rising edge of
XPULSE
INT_POL[1]=1: Interrupt on rising edge of
VPULSE
INT_POL[0]=1: Interrupt on rising edge of
WPULSE
14:12
Reserved
—
15
D_ODINTZ
31:16
Reserved
Enables an interrupt to occur when the CE
cycles is complete
Enable open-drain on the INTZ output. By
default, the pin is configured as a CMOS totempole output.
—
24
MAX71020
Single-Chip Electricity Meter AFE
Table 7. Register Map (continued)
NAME
BYTE
R/W
ADDRESS
DEFAULT
VALUE
BYTE ADDRESS
Reflects the status of several asynchronous events in the AFE
M_STAT
0x310
R
0x0100 0100
BIT
NAME
DESCRIPTION
0
F_WPULSE
Set on start of WPULSE
1
F_VPULSE
Set on start of VPULSE
2
F_XPULSE
Set on start of YPULSE
3
F_YPULSE
Set on start of XPULSE
4
F_XDATA
Set when data available
5
F_CEBUSY
6
Reserved
—
7
F_VSTAT
Set when VSYS status changes
Set at end of CE code pass
8
F_RESET
Set following AFE reset
15:9
Reserved
—
16
F_WPULSE
Copy of bit 0
17
F_VPULSE
Copy of bit 1
18
F_XPULSE
Copy of bit 2
19
F_YPULSE
Copy of bit 3
20
F_XDATA
Copy of bit 4
Copy of bit 5
21
F_CEBUSY
23:22
Reserved
—
24
F_RESET
Copy of bit 8
31:25
Reserved
—
25
MAX71020
Single-Chip Electricity Meter AFE
Table 7. Register Map (continued)
NAME
BYTE
R/W
ADDRESS
DEFAULT
VALUE
DESCRIPTION
Backup of M_STAT – updated when M_STAT is read
M_STAT_B
0x311
R
0x0100 0100
BIT
NAME
DESCRIPTION
0
FB_WPULSE
Set on start of WPULSE
1
FB_VPULSE
Set on start of VPULSE
2
FB_XPULSE
Set on start of YPULSE
3
FB_YPULSE
Set on start of XPULSE
4
FB_XDATA
Set when data available
5
FB_CEBUSY
Set at end of CE code pass
7:6
Reserved
—
8
FB_RESET
Set following AFE reset
15:9
Reserved
—
16
FB_WPULSE
Copy of bit 0
17
FB_VPULSE
Copy of bit 1
18
FB_XPULSE
Copy of bit 2
19
FB_YPULSE
Copy of bit 3
20
FB_XDATA
Copy of bit 4
21
FB_CEBUSY
Copy of bit 5
23:22
Reserved
—
24
FB_RESET
Copy of bit 8
31:25
Reserved
—
VSTAT
0x312
R
—
AFE Supply Voltage Status. Bits 1:0 reflect system power status:
00: System power-OK: VV3P3A > 3.0V
01: System power-low: 2.8V < VV3P3A < 3.0V
11: System power-fail: VV3P3A < 2.8V
RESET
0x322
WO
—
Write 0x8100 0000 to this register to reset the AFE.
26
MAX71020
Single-Chip Electricity Meter AFE
Table 7. Register Map (continued)
NAME
BYTE
R/W
ADDRESS
DEFAULT
VALUE
DESCRIPTION
Configures aspects of the temperature measurement subsystem
TEMP_CNF
TEMP_START
SPI_SAFE
0x323
0x324
0x325
R/W
R/W
R/W
0x0000 0000
BIT
NAME
1:0
Reserved
DESCRIPTION
—
3:2
TEMP_PER
Sets the period between temperature
measurements.
01: Measure every accumulation cycle
10: Continuous measurement
Other values disable automatic updates.
4
TEMP_SYS
When set, VSYS is measured at every
temperature measurement cycle
31:5
Reserved
—
0x0000 0000
Write 0x8000 0000 to start a temperature conversion cycle. When conversion
is complete, the AFE will clear bit 31 and return the register to zero.
0x0000 0000
Write 0x8000 0000 to this word to lock the SPI port. When the SPI port is
locked, no read or write operations are possible except to the SPI_SAFE
register. Clearing this register to zero disables the SPI lock and restores
normal operation.
Enables aspects of the AFE
METER_EN
0x326
R/W
0x0000 0000
BIT
NAME
0
ADC_E
1
CE_E
31:2
Reserved
DESCRIPTION
Enable ADC and VREF buffer. Must be set by
host following initialization.
Enable CE. Must be set by host following
initialization.
—
27
MAX71020
Single-Chip Electricity Meter AFE
CE Interface Description
The CE reads the ADC and stores its results in the 1KB
block at 0x000. Since all CE operations are 32 bits wide,
the CE data memory occupies the first 256 32-bit locations, from 0x000 to 0x0FF.
Note: The CE interface described in the data sheet is a
description of a CE codebase that was available at the
time of the writing. Changes may have occurred in the
codebase in the interim, and may not be reflected in this
document. Please contact your representative or Maxim
technical support for the latest information.
CE Data Format
All CE words are 4 bytes. Unless specified otherwise, they are in 32-bit two’s complement format (-1 =
0xFFFFFFFF). Calibration para­meters are copied to CE
data memory by the host microcontroller before enabling
the CE. Internal variables are used in internal CE calculations. Input variables allow the MPU to control the behavior of the CE code.
Constants
Constants used in the CE Data Memory tables are:
U f0 is the fundamental frequency of the mains phases.
U IMAX is the external RMS current corresponding to the
maximum allowed voltage on the current inputs. For
the IB input, this is 250mV peak (176.8mVRMS). In the
MAX71020, IA normally has a preamplifier enabled
on the IA inputs, so IMAX needs to be adjusted to
27.78mV peak (19.64mVRMS) for the IAP-IAN inputs.
For a 250µΩ shunt resistor, IMAX becomes 78A
(19.64mVRMS/250µΩ = 78.57A) for IA, and 707A
(176.8mVRMS/250µΩ = 707.2ARMS) for IB.
U VMAX is the external RMS voltage corresponding to
250mV peak at the VA and VB inputs.
U NACC, the accumulation count for energy measurements (typically 2520).
U The duration of the accumulation interval for energy
measurements is NACC/FS = 2520/2,520.6 ≈ 1s.
U X is a gain constant of the pulse generators. Its
value is determined by PULSE_FAST and PULSE_
SLOW(see Table 13).
U Voltage LSB (for sag threshold) = VMAX x 7.879810 - 9V.
The system constants IMAX and VMAX are used by the
host processor to convert internal digital quantities (as
used by the CE) to external, real-world metering quantities. Their values are determined by the scaling of the
voltage and current sensors used in an actual meter. The
LSB values used in this document relate digital quantities at the CE or MPU interface to external meter input
quantities. For example, if a SAG threshold of 80VRMS is
desired at the meter input, the digital value that should
be programmed into SAG_THR (register 0x024) would be
80VRMS x SQRT(2)/SAG_THRLSB, where SAG_THRLSB
is the LSB value in the description of SAG_THR (see
Table 14).
Environment
Before starting the CE (that is, before setting the CE_E
bit) the host processor must establish the equation to
be applied in EQU[2:0]. By default, default settings are
assumed to be VMAX = 600V, IMAX = 707A, and kH = 1.
CE Calculations
In Table 8, The MPU selects the desired equation by writing the EQU[2:0] (register 0x30D[14:12]).
Table 8. CE EQU Equations and Element Input Mapping
EQU
WATT AND VAR FORMULA
(WSUM/VARSUM)
0
VA IA – 1 element, 2W 1f
1
VA x (IA-IB)/2 – 1 element, 3W 1f
2
VA x IA + VB x IB– 2 element, 3W 1f
INPUTS USED FOR ENERGY/CURRENT CALCULATION
W0SUM/
VAR0SUM
W1SUM/
VAR1SUM
I0SQ
SUM
I1SQ
SUM
VA x IA
VA x IB
IA
—
VA x (IA-IB)/2
—
IA-IB
IB
VA x IA
VB x IB
IA
IB
28
MAX71020
Single-Chip Electricity Meter AFE
Table 9. CE Raw Data Access Locations
PIN
REGISTER
IA
0x100
VA
0x101
IB
0x102
VB
0x103
Table 10. CESTATUSRegister
CE ADDRESS
NAME
0x80
CESTATUS
DESCRIPTION
See the description of CESTATUS bits in Table 11
Table 11. CESTATUS (Register 0x080) Bit Definitions
CESTATUS
BIT
NAME
31:4
Not Used
3
F0
2
Not Used
1
SAG_B
Set when VB remains below SAG_THR for SAG_CNT samples. Automatically clears when VB
rises above SAG_THR.
0
SAG_A
Set when VA remains below SAG_THR for SAG_CNT samples. Automatically clears when VA
rises above SAG_THR.
DESCRIPTION
These unused bits are always zero
F0 is a square wave at the line frequency
This unused bit is always zero
CE Front-End Data (Raw Data)
Access to the raw data provided by the AFE is possible
by reading registers 0x100–0x003 as shown in Table 9.
CE Status and Control
The CE Status Word, CESTATUS, is useful for generating early warnings to the host processor (Table 10). It
contains sag warnings for phase A and B, as well as F0,
the derived clock operating at the line fre­quency. The
host microcontroller can read the CE status word at every
CE_BUSY interrupt.
CESTATUS provides information about the status of voltage and input AC signal frequency, which are useful for
generating an early power-fail warning to initiate necessary data storage. CESTATUS represents the status flags
for the preceding CE code pass (CE_BUSY interrupt).
The significance of the bits in CESTATUS is shown in
Table 11.
29
MAX71020
Single-Chip Electricity Meter AFE
Table 12. CECONFIG Register
CE ADDRESS
NAME
DATA
0x20
CECONFIG
0x0030DB00
DESCRIPTION
See the description of the CECONFIG bits in Table 13
Table 13. CECONFIG Bit Definitions
CECONFIG BIT
NAME
DEFAULT
DESCRIPTION
21
EDGE_INT
1
When 1, XPULSE produces a pulse for each zero-crossing of the mains phase
selected by FREQSEL[1:0] that can be used to interrupt the host microcontroller
20
SAG_INT
1
When 1, activates YPULSE output when a sag condition is detected
19:8
SAG_CNT
252
(0xFC)
The number of consecutive voltage samples below SAG_THR (register 0x24)
before a sag alarm is declared. The default value is equivalent to 100ms
FREQSEL[1:0] selects the phase to be used for the frequency monitor, sag
detection, and for the zero-crossing counter (MAINEDGE_X, register 0x083)
7:6
5:2
1
0
FREQSEL[1:0]
Reserved
PULSE_FAST
PULSE_SLOW
0
0
0
FREQ SEL[1:0]
PHASE SELECTED
0
0
A
0
1
B
1
X
Not allowed
Reserved
When PULSE_FAST = 1, the pulse generator input is increased 16x. When
PULSE_SLOW = 1, the pulse generator input is reduced by a factor of 64.
These two parameters control the pulse gain factor X (see table below). Allowed
values are either 1 or 0. Default is 0 for both (X = 6).
PULSE_FAST
PULSE_SLOW
X
0
0
1.5 x 22 = 6
1
0
1.5 x 26 = 96
0
1
1.5 x 2-4 = 0.09375
1
1
Do not use
0
The CE is initialized by the host microcontroller using
CECONFIG (Table 12). This register contains the
SAG_CNT, FREQSEL[1:0], PULSE_SLOW, and
PULSE_FAST fields. The CECONFIG bit definitions are
given in Table 13.
The FREQSEL[1:0] field in CECONFIG (register
0x020[7:6]) selects the phase that is utilized to generate
a sag interrupt. Thus, a SAG_INT event occurs when the
selected phase has satisfied the sag event criteria as set
by SAG_THR (register 0x24) and the SAG_CNT field in
CECONFIG (register 0x020[19:8]). When the SAG_INT
bit (register 0x020[20]) is set to 1, a sag event gener-
ates a transition on the YPULSE output. In a two-phase
system, and after a sag interrupt, the host microcontroller
should change the FREQSEL[1:0] setting to select the
other phase, if it is powered. Even though a sag interrupt
is only generated on the selected phase, both phases
are simultaneously checked for sag. The presence of
power on a given phase can be sensed by directly
checking the SAG_A and SAG_B bits in CESTATUS (register 0x080[1:0]).
The CE controls the pulse rate based on WSUM_X (register 0x084) and VARSUM_X (register 0x088).
30
MAX71020
Single-Chip Electricity Meter AFE
CE Transfer Variables
When the host microcontroller receives the XFER_BUSY
interrupt, it knows that fresh data is available in the transfer variables. CE transfer variables are modified during
the CE code pass that ends with an XFER_BUSY interrupt. They remain constant throughout each accumulation interval. In this data sheet, the names of CE transfer
variables always end with “_X”. The transfer variables
can be categorized as:
U Fundamental energy measurement variables
U Instantaneous (RMS) values
U Other measurement parameters
Fundamental Energy Measurement Variables
Table 15 describes each transfer variable for fundamental energy measurement. All variables are signed 32-bit
integers. Accumulated variables such as WSUM are
internally scaled so that internal values are no more than
50% of the full-scale range when the integration time is
one second. Additionally, the hardware does not permit
output values to fold back upon overflow.
WSUM_X (register 0x084) and VARSUM_X (register
0x088) are the signed sum of Phase-A and Phase-B Wh
or VARh values according to the metering equation specified in EQU[2:0](register 0x30D[14:12]). WxSUM_X (x =
0 or 1, registers 0x085 and 0x086) is the watt-hour value
accumulated for phase x in the last accumulation interval
and can be computed based on the specified LSB value.
Table 14. Sag Threshold and Gain Adjust Control
CE
ADDRESS
0x24
NAME
SAG_THR
DEFAULT
2.39 x 107
DESCRIPTION
The voltage threshold for sag warnings. The default value is equivalent to
113Vpk or 80VRMS if VMAX = 600VRMS.
SAG_THR =
VRMS × 2
VMAX × 7.8798 × 10 −9
0x40
GAIN_ADJ0
16384
This register scales the voltage measurement channels VA and VB. The default
value of 16384 is equivalent to unity gain (1.000).
0x41
GAIN_ADJ1
16384
This register scales the IA current channel for Phase A. The default value of
16384 is equivalent to unity gain (1.000).
0x42
GAIN_ADJ2
16384
This register scales the IB current channel for Phase B. The default value of
16384 is equivalent to unity gain (1.000).
Table 15. CE Transfer Variables
CE
ADDRESS
NAME
0x84
WSUM_X
0x85
W0SUM_X
0x86
W1SUM_X
0x88
VARSUM_X
0x89
VAR0SUM_X
0x8A
VAR1SUM_X
DESCRIPTION
CONFIGURATION
The signed sum: W0SUM_X + W1SUM_X. Not used for
EQU[2:0] = 0 (register 0x30D[14:12]) and EQU[2:0] = 1.
The sum of Wh samples from each wattmeter element.
LSBW = 6.08040 x 10-13 x VMAX x IMAX Wh
The signed sum: VAR0SUM_X + VAR1SUM_X. Not used for
EQU[2:0] = 0 and EQU[2:0] = 1.
Figure 8
The sum of VARh samples from each wattmeter element.
LSBW = 6.08040 x 10-13 x VMAX x IMAX VARh
31
MAX71020
Single-Chip Electricity Meter AFE
Instantaneous Energy Measurement Variables
I_SQSUM_X and V_SQSUM (see Table 16) are the sum
of the squared current and voltage samples acquired
during the last accumulation interval.
The RMS values can be computed by the host microcontroller from the squared current and voltage samples as
follows:
I_SQSUM × LSBI × 9,074,160
I RMS =
N ACC
Other
VRMS =
V_SQSUM × LSB V × 9,074,160
N ACC
Other transfer variables include those available for
frequency and those reflecting the count of the zerocrossings of the mains voltage. These transfer variables
are listed in Table 17.
MAINEDGE_X (register 0x083) reflects the number of
half-cycles accounted for in the last accumulated interval for the AC signal of the phase specified in the
FREQSEL[1:0] field in CECONFIG (register 0x020[7:6]).
MAINEDGE_X is useful for implementing a real-time
clock based on the input AC signal.
Pulse Generation
Table 18 describes the CE pulse generation parameters.
The combination of the CECONFIG:PULSE_SLOW and
CECONFIG:PULSE_FAST bits (register 0x020[0:1]) controls the speed of the pulse rate. The default zero values
of these configuration bits maintain the original pulse rate
given by the Kh equation, follows in this section.
WRATE (register 0x021) controls the number of pulses
that are generated per measured Wh and VARh. The
lower WRATE is, the slower the pulse rate for the measured energy quantity; or conversely, the greater the
measured energy per pulse. By default, the pulse generators take their input from the W0SUM_X (register 0x085)
and VAR0SUM_X (register 0x089) result registers.
The meter constant Kh is derived from WRATE and represents the amount of energy measured for each pulse. If
Kh = 1Wh/pulse and 120V and 30A is applied in-phase to
the meter, the meter will produce one pulse per second
(120V and 30A results in a load of 3600W, or put another
way, energy consumption of one watt-hour per second).
If the load is 240V at 150A, ten pulses per second are
generated. To compute the WRATE value, see Table 18.
The maximum pulse rate is 7.56kHz.
Table 16. CE Energy Measurement Variables
CE
ADDRESS
NAME
0x8C
I0SQSUM_X
0x8D
I1SQSUM_X
0x90
V0SQSUM_X
0x91†
V1SQSUM_X
DESCRIPTION
CONFIGURATION
The sum of squared current samples from each element.
LSBI = 6.08040 x 10-13 IMAX2 A2h
When EQU = 1, I0SQSUM_X is based on IA and IB.
Figure 8
The sum of squared voltage samples from each element.
LSBV= 6.08040 x 10-13 VMAX2 V2h
Table 17. Other Transfer Variables
CE
ADDRESS
NAME
0x82
FREQ_X
0x83
MAINEDGE_X
DESCRIPTION
Fundamental frequency:
LSB ≡
2520.6Hz
2 32
≈ 0.509 × 10 -6
The number of edge crossings of the selected voltage in the previous accumulation
interval. Edge crossings are either direction and are debounced.
32
MAX71020
Single-Chip Electricity Meter AFE
See the VPULSE and WPULSE section for details on how
to adjust the timing of the output pulses. The maximum
time jitter is 1/6 of the multiplexer cycle period (nominally 67µs) and is independent of the number of pulses
measured. Thus, if the pulse generator is monitored for
one second, the peak jitter is 67ppm. After 10s, the peak
jitter is 6.7ppm. The average jitter is always zero. If it
is attempted to drive either pulse generator faster than
its maximum rate, it simply outputs at its maximum rate
without exhibiting any rollover characteristics. The actual
pulse rate, using WSUM as an example, is:
RATE =
WRATE × WSUM × fS × X
2 46
where fS = sampling frequency (2520.6Hz), X =
pulse speed factor derived from the CE variables
PULSE_SLOW (register 0x020[0]) and PULSE_FAST
(register 0x020[1]).
Other CE Parameters
Table 19 shows the CE parameters used for suppression
of noise due to scaling and truncation effects.
CE Calibration Parameters
Table 20 lists the parameters that are typically entered to
effect calibration of meter accuracy.
CE Flow Diagrams
Figure 10 to Figure 12 show the data flow through the
CE in simplified form. Functions not shown include delay
compensation, sag detection, scaling, and the processing of meter equations.
Hz
Table 18. CE Pulse Generation Parameters
CE
ADDRESS
NAME
DEFAULT
DESCRIPTION
Kh =
K × VMAX × IMAX
Wh pulse
SUM_SAMPS × WRATE × X
0x21
WRATE
547
where:
K = 42.7868
See Table 13 for the definition of X.
The default value yields 1.0 Wh/pulse for VMAX = 600V and IMAX = 208A. The
maximum value for WRATE is 32,768 (215).
0x22
KVAR
6444
Scale factor for VAR measurement
0x45
WPULSE_CTR
0
WPULSE counter
0x46
WPULSE_FRAC
0
Unsigned numerator, containing a fraction of a pulse. The value in this register
always counts up towards the next pulse.
0x47
WSUM_ACCUM
0
Rollover accumulator for WPULSE
0x4A
VPULSE_CTR
0
VPULSE counter
0x4A
VPULSE_FRAC
0
Unsigned numerator, containing a fraction of a pulse. The value in this register
always counts up towards the next pulse.
0x4B
VSUM_ACCUM
0
Rollover accumulator for VPULSE
33
MAX71020
Single-Chip Electricity Meter AFE
Table 19. CE Parameters for Noise Suppression and Code Version
CE
ADDRESS
NAME
DEFAULT
0x25
QUANT_VA
0
0x26
QUANT_IA
0
0x27
QUANT_A
0
0x28
QUANT_VARA
0
0x29
QUANT_VB
0
0x2A
QUANT_IB
0
0x2B
QUANT_B
0
0x2C
QUANT_VARB
0
DESCRIPTION
Compensation factors for truncation and noise in voltage, current, real energy, and
reactive energy for phase A.
Compensation factors for truncation and noise in voltage, current, real energy, and
reactive energy for phase B.
QUANT_Ix_LSB= 3.28866 × 10 -13 × IMAX 2 (Amps 2 )
QUANT_Wx_LSB= 6.73518 × 10 -10 × VMAX × IMAX (Watts)
QUANT_VARx_LSB= 6.73518 × 10 -10 × VMAX × IMAX (Vars)
Table 20. CE Calibration Parameters
CE
ADDRESS
NAME
DEFAULT
0x10
CAL_IA
16384
0x11
CAL_VA
16384
0x13
CAL_IB
16384
0x14
CAL_VB
16384
0x12
PHADJ_A
0
DESCRIPTION
These constants control the gain of their respective channels. The nominal
value for each parameter is 214 = 16384. The gain of each channel is directly
proportional to its CAL parameter. Thus, if the gain of a channel is 1% slow, CAL
should be increased by 1%.
These constants control the CT phase compensation. Compensation does not
occur when PHADJ_X = 0. As PHADJ_X is increased, more compensation (lag)
is introduced. The range is ±215 – 1. If it is desired to delay the current by the
angle F, the equations are:
PHADJ_X = 2 20
0x15
PHADJ_B
0
PHADJ_X = 2 20
0.02229 × TANF
at 60Hz
0.1487 - 0.0131× TANF
0.0155 × TANF
at 50Hz
0.1241- 0.009695 × TANF
34
MAX71020
Single-Chip Electricity Meter AFE
MULTIPLEXER
I0
V0
I1
VREF
DC
MOD
DEMULTIPLEXER
I0_RAW
V0_RAW
I1_RAW
DECIMATOR
fS = 2520Hz
(ON EACH CHANNEL)
fCLK = 4.9152MHz
Figure 10. CE Data Flow (Multiplexer and ADC)
I0_RAW
I0
OFFSET
NULL
F0
CAL_I0
PHASE
COMP
LPF
W0
PHADJ_0
LPF
VAR0
V0_RAW
V0
OFFSET
NULL
90°
F0
CAL_V0
I1_RAW
OFFSET
NULL
F0
PHASE
COMP
CAL_I1
GAIN_ADJ
LPF
VAR1
LPF
W1
PHADJ_1
I1
F0
GENERATOR
F0
Figure 11. CE Data Flow (Scaling, Gain Control, Intermediate Variables)
35
MAX71020
Single-Chip Electricity Meter AFE
SUM
W0
C
W1
C
VAR0
C
VAR01
C
W0SUM_X
W1SUM_X
VAS0SUM_X
VAR1SUM_X
SUM_SAMPS
= 2520
SUM
SQUARE
I0
I2
V0
V2
I1
I2
MPU
IOSQ
VOSQ
IISQ
C
C
C
IOSQSUM_X
VOSQSUM_X
IISQSUM_X
F0
Figure 12. CE Data Flow (Squaring and Summation Stages)
Ordering Information
PART
PINACCURACY
PACKAGING
PACKAGE
(%)
MAX71020AEUI+
28 TSSOP
0.5
Bulk
MAX71020AEUI+R
28 TSSOP
0.5
Tape and reel
Note: All devices are specified over the -40°C to +85°C operating temperature range.
+Denotes a lead(Pb)–free/RoHS-compliant package.
Package Information
For the latest package outline information and land patterns
(footprints), go to www.maxim-ic.com/packages. Note that a
“+”, “#”, or “-” in the package code indicates RoHS status only.
Package drawings may show a different suffix character, but
the drawing pertains to the package regardless of RoHS status.
PACKAGE
TYPE
PACKAGE
CODE
OUTLINE
NO.
LAND
PATTERN NO.
28 TSSOP
U28+1
21-0066
90-0171
36
MAX71020
Single-Chip Electricity Meter AFE
Revision History
REVISION
NUMBER
REVISION
DATE
0
7/12
DESCRIPTION
Initial release
PAGES
CHANGED
—
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied.
Maxim reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical