MA-COM 6VAQ8F

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
High Frequency Power Line Filter or Power Entry Module
AQ Series
UL Recognized
CSA Certified
3VAQ8F
6VAQ8F
AQ Series
Specifications
• Low cost solution to power line noise at high
frequencies
• High common and differential mode performance
from 10kHz to 1GHz
• Available with an IEC inlet, fuseholder and switch
• Suitable for applications where computers are
used to process secret or confidential information
Ordering Information
Maximum leakage current each Line to Ground:
3A Models
6A Models
1.2 mA
2.3 mA
.7 mA
1.2 mA
@ 120 VAC 60 Hz:
@250 VAC 50 Hz:
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max):
250 VAC
Operating Frequency:
50/60 Hz
Rated Current:
3 V AQ 8 FS
Suffix
F – Fuseholder
FS – Fuseholder & Switch
(F & FS on VAQ8 only)
Omit if none
Input / Output Style
3 – Wire leads
8 – IEC inlet* (line side)
Wire leads (load side)
2250 VDC
1450 VDC
3 or 6A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Electrical Schematics
3A Models
LINE
LOAD
6A Models
AQ Series
LINE
LOAD
Leakage current designation
V – Standard
Current Rating
3 or 6A
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Available Part Numbers
3VAQ3
3VAQ8F
3VAQ8FS
6VAQ3
6VAQ8F
6VAQ8FS
*IEC 60320-1 C14 inlet mates with C13 connector
12
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
High Frequency Power Line Filter or Power Entry Module (continued)
AQ Series
Case Styles and Dimensions
3VAQ3
6VAQ3
2.46
62.3
.515
13.08
1
2.572 C
L
65.3
12.0 Min.
304.8
.515
13.08
#6-32
1.0 ± 0.1
25.4 ± .25
#6-32
5.126
130.0
5.327±.015
135.3
12.0 Min.
304.8
(5 places)
#6-32
(2 places)
#6-32 Thd.
.5 ± .01
12.7 ± .25
(2 x)
3.061
77.8
2.0 ± .01
50.8 ± .25
.78
19.8
.50 ± .02
12.7 ± .5
3VAQ8F
6VAQ8F
6.457
164
5.68 ± .01
44.3 ± .25
4.0 ± .01
102 ± .25
5.96
152.0
5.06 ± .015
128.6 ± .38
2.35 ± .015
59.6 ± .38
.90
22.9
1.58 ±.015
40 ± .38
12.0 Min.
305.0
.958
24.3
2.48
63.0
.355
ref
9.02
#6-32
(6) inserts
.411
ref
10.4
2.328 ± .01
59 ± .35
1.125 ± .01 3.062
28.6 ± .25 77.8
#6-32
(6) inserts
.354 ±.010 ref
8.99 ± .25
2.576
65.4
.375 ± .125
9.53 ± 3.2
.375 ± .125
9.53 ± 3.2
3VAQ8FS
6VAQ8FS
5.39 ± .015
136.9 ± .38
2.35 ± .015
59.6 ± .38
1.058
26.9
.172
4.37
#6-32
(6) inserts
.44
11.2
1.575 ± .015
40.01 ± .38
.958
24.3
#6-32
(6) inserts
.411
ref
10.4
1.62
41.2
12.0 Min.
305.0
6.30
160.0
.391 ± .01
9.93 ± .25
12.0 Min.
305.0
1.62
41.2
.375 ± .125
9.53 ± 3.2
RFI Power Line Filters
4.14
105.1
4.36 ± .015
111.4 ± .38
1.98
40.1
1.66 ± .015
42.1 ± .38
CL
2.48
63.0
7.125
181.0
6.347 ± .015
161.2 ± .38
4.0 ± .015
101.55 ± .25
2.33 ±.015
59.0 ± .38
.364
9.25
12.0 Min.
304.8
1.52 ± .01 3.07
38.5 ± .25 77.8
1.12 ± .01
28.3 ± .25
.391 ± .01
9.93 ± .25
2.58
65.4
.375 ± .125
9.53 ± 3.2
13
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
High Frequency Power Line Filter or Power Entry Module (continued)
AQ Series
Recommended Panel Cutouts
.910 ± .005
23.11 ± .13
.855 ± .005
21.72 ± .13
.235 ± .005
R
5.969 ± .13
.620 ± .005
15.75 ± .13
1.295 ± .005
32.89 ± .13
.620 ± .005
Dia.
15.75 ± .13
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
3VAQ
6VAQ
db
db
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
0
10
0.01
0.1
1
10
0
100
1000
Frequency in MHz
0.01
0.1
1
10
100
1000
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)

 


Differential Mode / Symmetrical (Line to Line)


    

 




    








































14
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com