VECTRON VCA3-A2H

VCA3 series
3.3, 5.0 volt CMOS Oscillator
Features
• CMOS output
• Output frequencies to 160 MHz
• Tri-state output for board test and debug
• 0/70 or –40/85 °C operating temperature
• Product is compliant to RoHS directive
and fully compatible with lead free assembly
The VCA3 Crystal Oscillator
Applications
• SONET/SDH/DWDM
• Ethernet, Gigabit Ethernet
• Storage Area Network
• Digital Video
• Broadband Access
fo
Output
Buffer /
Disable
• Microprocessors/DSP/FPGA
Description
Vectron’s VCA3 Crystal Oscillator (XO) is quartz
stabilized square wave generator with a CMOS
output, operating off a 3.3 or 5.0 volt supply.
The VCA3 uses fundamental or 3rd overtone
crystals, for output frequencies < 80MHz,
resulting in low jitter performance, typically 0.5ps
rms in the 12 kHz to 20MHz band.
Vectron International 267 Lowell Road, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail: [email protected]
Performance Characteristics
Table 1. Electrical Performance, 5V option
Parameter
Symbol
Frequency
fO
Operating Supply Voltage 1
VDD
Absolute Maximum Supply Voltage
Supply Current, Output Enabled
IDD
0.032768 to 2.0 MHz
2.01 to 30 MHz
30.01 to 50 MHz
50.01 to 160.00 MHz
Output Logic Levels
Output Logic High2
VOH
Output Logic Low2
VOL
Output Rise/Fall Time2
tR/tF
0.032768 to 2.00 MHz
2.01 to 20.00 MHz
20.01 to 160.00 MHz
Duty Cycle3 (ordering option)
SYM
Operating Temperature (ordering option)
TOP
Storage Temperature
TSTOR
Stability4 (ordering option)
∆F/T
Output Enable/Disable5
E/D
Output Enabled
Output Disabled
Start-up time
TSU
Min
0.032768
4.5
-0.7
Typical
Maximum
160.000
5.5
7.0
5.0
Units
MHz
V
V
mA
10
15
40
50
0.9*VDD
0.1*VDD
V
V
ns
10
8
5
40/60 or 45/55
0/70 or -40/85
-55
125
±10, ±20, ±25, ±32, ±50, ±100
%
°C
°C
ppm
V
4.0
0.8
10
ms
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.
2. Figure 1 defines these parameters. Figure 2 illustrates the operating conditions under which these parameters are tested and
specified.
3. Symmetry is measured defined as On Time/Period.
4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under
operation).
5. Output will be enabled if enable/disable is left open.
tR
tF
I DD
V OH
50%
VD D
V OL
+
-
4
. 1µF
.01µF
1
2
3
IC
On Time
VC
Period
Figure 1. Output Waveform
Vectron International 267 Lowell Rd, Hudson NH 03051
+
15pF
-
Figure 2. Typical Output Test Conditions (25±5°C)
Tel: 1-88-VECTRON-1
e-mail: [email protected]
VCA3 Data Sheet
Table 2. Electrical Performance, 3.3V option
Parameter
Symbol
Frequency
fO
1
Operating Supply Voltage
VDD
Absolute Maximum Operating Voltage
Supply Current, Output Enabled
IDD
0.032786 to 2.0 MHz
2.01 to 30 MHz
30.01 to 50 MHz
50.01 to 160 MHz
Output Logic Levels
Output Logic High2
VOH
Output Logic Low2
VOL
Output Rise/Fall Time2
tR/tF
0.032768 to 2.00 MHz
2.01 to 20.00 MHz
20.01 to 160.00 MHz
Duty Cycle3 (ordering option)
SYM
Operating Temperature (ordering option)
TOP
Storage Temperature
TSTOR
Stability4 (ordering option)
∆F/T
Output Enable/Disable5
E/D
Output Enabled
Output Disabled
Start-up time
TSU
Min
0.032768
2.97
-0.5
Typical
Maximum
160.000
3.63
5.0
3.3
Units
MHz
V
V
mA
8
10
20
35
0.9*VDD
0.1*VDD
V
V
ns
12
10
6
40/60 or 45/55
0/70 or –40/85
-55
125
±10, ±20, ±25, ±32, ±50, ±100
%
°C
°C
ppm
V
2.0
0.5
10
ms
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.
2. Figure 3 defines these parameters. Figure 4 illustrates the operating conditions under which these parameters are tested and
specified. For Fo>90MHz, rise and fall time is measured 20 to 80%.
3. Symmetry is measured defined as On Time/Period.
4. Includes calibration tolerance, operating temperature, supply voltage variations, aging and shock and vibration (not under
operation).
5. Output will be enabled if enable/disable is left open.
tR
tF
I DD
V OH
50%
VD D
V OL
+
-
4
. 1µF
.01µF
1
2
3
IC
On Time
VC
Period
Figure 3. Output Waveform
Vectron International 267 Lowell Rd, Hudson NH 03051
+
15pF
-
Figure 4. Typical Output Test Conditions (25±5°C)
Tel: 1-88-VECTRON-1
e-mail [email protected]
VCA3 Data Sheet
Enable/Disable Functional Description
Under normal operation the Enable/Disable is left open or set to a logic high state. When the E/D is set to a
logic low, the oscillator stops and the output is in a high impedance state. This helps reduce power
consumption as well as facilitating board testing and troubleshooting.
Tri-state Functional Description
Under normal operation the tri-state is left open or set to a logic high state. When the tri-state is set to a
logic low, the oscillator remains active but the output buffer is in a high impedance state. This helps facilitate
board testing and troubleshooting.
Table 3. Outline Diagrams and Pin Out
Pin #
Symbol
Function
1
2
3
4
E/D or NC
GND
fO
V DD
Tri-state, Enable/Disable or NC
Electrical and Case Ground
Output Frequency
Supply Voltage
Figure 5, Package drawing
Vectron International 267 Lowell Rd, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail [email protected]
VCA3 Data Sheet
Reliability
The VCA3 qualification tests have included:
Table 4. Environnemental Compliance
Parameter
Mechanical Shock
Mechanical Vibration
Temperature Cycle
Gross and Fine Leak
Resistance to Solvents
MIL-STD-883
MIL-STD-883
MIL-STD-883
MIL-STD-883
MIL-STD-883
Conditions
Method 2022
Method 2007
Method 1010
Method 1014
Method 2015
Handling Precautions
Although ESD protection circuitry has been designed into the the VCA3, proper precautions should be taken
when handling and mounting. VI employs a Human Body Model and a Charged-Device Model (CDM) for
ESD susceptibility testing and design protection evaluation. ESD thresholds are dependent on the circuit
parameters used to define the model. Although no industry wide standard has been adopted for the CDM, a
standard HBM of resistance = 1.5kohms and capacitance = 100pF is widely used and therefore can be
used for comparison purposes.
Table 5. ESD Ratings
Model
Human Body Model
Charged Device Model
Minimum
1000
1500
Conditions
MIL-STD-883 Method 3115
JESD 22-C101
Suggested IR profile
Devices are built using lead free epoxy and can also be subjected to standard lead free IR reflow conditions,
Table 6 shows max temperatures and lower temperatures. A peak temperature of 240°C minimum should be
used to reflow the lead solder.
Table 6. Reflow Profile (IPC/JEDEC J-STD-020)
Parameter
Symbol
Preheat Time
Ramp Up
Time Above 217 oC
Time To Peak Temperature
Value
tS
150 sec Min, 200 sec Max
R UP
3 oC/sec Max
tL
60 sec Min, 150 sec Max
t AMB-P
480 sec Max
Time At 260 oC (max)
tP
10 sec Max
Time At 240 °C (max)
tp2
60 sec Max
R DN
6 oC/sec Max
Ramp Down
Vectron International 267 Lowell Rd, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail [email protected]
VCA3 Data Sheet
Ordering Information:
VCA3 -
B
3
B -
25M00
Product Family
Output Frequency
Crystal Oscillator
In MHZ
Full Size 14 Pin DIP
Electrical Options
Stability Options
Voltage Options
3: Tri-state, 45/55% Duty
A: ±100ppm, 0 to 70°C
A: +5.0 Vdc +/-10%, 15pF
The following codes are not
C: ±100ppm, -40 to 85°C
B: +3.3 Vdc +/-10%, 15pF
recommended for new designs
B: ±50ppm, 0 to 70°C
C: +3.0 Vdc +/-5%, 15pF
0: No tri-state, 40/60% Duty
D: ±50ppm, -40 to 85°C
E: +5.0 Vdc +/-10%, 50pF
1: Tri-state, 40/60% Duty
E: ±25ppm, 0 to 70°C
F: +3.3Vdc +/-5%, 50pF
2: No tri-state, 45/55%Duty
F: ±25ppm, -40 to 85°C
5: Enable, 40/60% Duty
G: ±20ppm *, 0 to 70°C
6: Enable, 45/55% Duty
H: ±10ppm *, -10 to 70°C
*Aging not included.
Note: Not all combinations are available.
Tri-state with a 45/55% is the most common Electrical code and is recommended for most applications.
Devices will be shipped in Anti Static Tubes
For Additional Information, Please Contact:
www.vectron.com
USA: Vectron International • 267 Lowell Road, Hudson, NH 03051
• Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON
EUROPE: Landstrasse, D-74924, Neckarbischofsheim, Germany •
Tel: 49 (0) 7268 8010 • Fax: 49 (0) 7268 801281
ASIA: Vectron Asia Pacific Sales 1F~2F. No.8 Workshop No.308 Fenju Rd.,
WaiGaoQiao Free Trade Zone, Pudong New Area Shanghai, China 200131
•Tel: 8621 50480777 • Fax: 8621 50481881
July3, 2007
Vectron International 267 Lowell Rd, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail [email protected]