HWS50-1500/HD Series Single Output Industrial Power Supplies Features u Limited Lifetime Warranty u -10 to +71°C Operation (-40°C start up) u Universal Input (85 - 265VAC) u Conformally coated pcbs u Class 1 Div 2 option (/RYHD suffix) u Wide range AC Input Key Market Segments & Applications Specifications Model Input Voltage range (47-63Hz) Input Current (Typ) (1) Inrush Current (1) Power Factor Temperature Coefficient Overcurrent Protection Overvoltage Protection Hold Up Time (Typ) Leakage Current (60Hz) Remote Sense Indicator Remote On/Off Parallel operation DC Good Remote Adjust (PV) Operating Temperature and Derating (operation to +74°C - contact factory) Storage Temperature Humidity (non condensing) Cooling Withstand Voltage (2) Isolation Resistance Vibration (non operating) Shock (in packaging) Safety Agency Approvals Line Dip Conducted & Radiated EMI Immunity Weight (Typ) Size (WxHxD) Warranty A A V ms mA °C °C g in yrs HWS50 HWS100 HWS150 HWS300 HWS600 HWS1000 HWS1500 85-265VAC or 120-370VDC 85-265VAC or 120-330VDC (No DC input for HWS1500) 0.7 / 0.35 1.3 / 0.65 1.9 / 0.95 4.1 / 2.1 8.1 / 3.9 13.5 / 7 19 / 10 14 / 2 20 / 4 Meets EN61000-3-2 <0.02%/°C >104% Yes (See table on page 2) 20 <0.5mA <0.75mA <1.2mA ≤1.5mA No Yes Green LED = ON No Yes (Isolated from output) No Single wire connection (5 units max) No Yes No Yes (3) HWS50-150: -10°C to +71°C, (-10 ~+50°C: 100%, +60°C: 60%, +71°C: 20%) HWS300-1500: -10°C to +71°C, (-10 ~+50°C: 100%, derate linearly to 50% load from +50 to +71°C) Guaranteed start up at -40°C (see specification sheets on website for details and derating) -40 to +85°C Operating: 30 - 90%RH (10 -90% on HWS300-1500), Non operating 10 - 95%RH Convection Internal fan Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. >100MΩ at 25°C & 70%RH, Output to Ground 500VDC, >10M Output to remote on/off 100VDC MIL-STD-810F 514.5 Category 4, 10 (HWS1500 Cat 4, figure 514.5C-1) MIL-STD-810F 516.5 Category I, VI (HWS1500 <196.1m/s2) UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark Complies with SEMI F47 (200VAC line only) EN55011 / EN55022-B, FCC-B, VCCI-B (HWS1500 Class A) IEC61000-4-2 (Level 2,3), -3, -4, -6, (Level 3), -5, -8 (Level 4), -11 280 450 500 1000 1600 3200 3800 1.04x3.23x4.72 1.1x3.23x6.3 1.46x3.23x6.3 2.4x3.23x6.5 3.94x3.23x6.5 5x3.2x9.5 5x3.25x11 Limited lifetime warranty (See TDK-Lambda’s terms & conditions) (1) 100/200VAC input (2) HWS300-600 2.5kVAC Input to ground 1-800-526-2324 • www.us.tdk-lambda.com/lp/ (3) 1-6V program voltage input to adjust output 20-120% (typical) of nominal. See instruction manual for details & models with this feature. (*) Class 1 Div 2 option (/RYHD suffix 63 Disclaimer: us.tdk-lambda.com/lp/legal.htm HWS50-1500/HD Series Output Ratings Model Voltage HWS50-3/HD 3.3V HWS100-3/HD 3.3V HWS150-3/HD 3.3V HWS300-3/HD 3.3V HWS600-3/HD 3.3V HWS1000-3/HD 3.3V HWS1500-3/HD 3.3V HWS50-5/HD 5V HWS100-5/HD 5V HWS150-5/HD 5V HWS300-5/HD 5V HWS600-5/HD 5V HWS1000-5/HD 5V HWS1500-5/HD 5V HWS1000-6/HD 6V HWS1000-7/HD 7.5V HWS50-12/HD 12V HWS100-12/HD 12V HWS150-12/HD 12V HWS300-12/HD 12V HWS600-12/HD 12V HWS1000-12/HD 12V HWS1500-12/HD 12V HWS50-15/HD 15V HWS100-15/HD 15V HWS150-15/HD 15V HWS300-15/HD 15V HWS600-15/HD 15V HWS1000-15/HD 15V HWS1500-15/HD 15V HWS50-24/HD 24V HWS100-24/HD 24V HWS150-24/HD 24V HWS300-24/HD 24V HWS600-24/HD 24V HWS1000-24/HD 24V HWS1500-24/HD 24V HWS1000-36/HD 36V HWS1500-36/HD 36V HWS50-48/HD 48V HWS100-48/HD 48V HWS150-48/HD 48V HWS300-48/HD 48V HWS600-48/HD 48V HWS1000-48/HD 48V HWS1500-48/HD 48V HWS1000-60/HD 60V Adjust Max Peak Max Load Line Ripple Overvoltage Efficiency Range Curr(A) Curr(A)4 Power(W) Reg(mV) Reg(mV) Noise(mV) (V) (typ)%1 2.97 - 3.96 10 33 40 20 120 4.13-4.95 76/78 2.97 - 3.96 20 66 40 20 120 4.13-4.95 78/81 2.97 - 3.96 30 99 40 20 120 4.13-4.95 78/81 2.64 - 3.96 60 198 30 20 120 4.13-4.95 74/77 2.64 - 3.96 120 396 30 20 120 4.13-4.95 75/78 2.64 - 3.96 200 660 40 20 120 4.12-4.62 71/73 2.64 - 3.96 300 990 60 36 150 4.12-4.62 72/75 4.0 - 6.0 10 50 40 20 120 6.25-7.25 82/84 4.0 - 6.0 20 100 40 20 120 6.25-7.25 83/86 4.0 - 6.0 30 150 40 20 120 6.25-7.25 83/86 4.0 - 6.0 60 300 30 20 120 6.25-7.25 79/82 4.0 - 6.0 120 600 30 20 120 6.25-7.25 80/83 4.0 - 6.0 200 1000 40 20 120 6.25-7 76/78 4.0 - 6.0 300 1500 60 36 150 6.25-7 77/81 4.8 - 7.2 167 1002 60 36 150 7.5-8.4 79/81 6.0 - 9.0 134 160 1005 60 36 150 9.37-10.5 80/82 9.6 - 14.4 4.3 51.6 96 48 150 15-17.4 81/83 9.6 - 14.4 8.5 102 96 48 150 15-17.4 83/86 9.6 - 14.4 13 156 96 48 150 15-17.4 83/86 9.6 - 14.4 27 324 72 48 150 15-17.4 80/83 9.6 - 14.4 53 636 72 48 150 15-17.4 80/83 9.6 - 14.4 88 100 1056 100 48 150 15-17.4 82/85 9.6 - 14.4 125 1500 72 48 150 15-17.4 82/85 12.0 - 18.0 3.5 52.5 120 60 150 18.8-21.8 81/83 12.0 - 18.0 7 105 120 60 150 18.8-21.8 83/86 12.0 - 18.0 10 150 120 60 150 18.8-21.8 83/86 12.0 - 18.0 22 330 90 60 150 18.8-21.8 80/83 12.0 - 18.0 43 645 90 60 150 18.8-21.8 81/84 12.0 - 18.0 70 80 1500 120 60 150 18.7-21.8 83/85 12.0 - 18.0 100 1500 90 60 150 18.7-21.8 83/87 19.2 - 28.8 2.2 52.8 192 96 150 30-34.8 82/84 19.2 - 28.8 4.5 108 192 96 150 30-34.8 84/87 19.2 - 28.8 6.5 156 192 96 150 30-34.8 85/88 19.2 - 28.8 14 16.5 336 144 96 150 30-34.8 82/85 19.2 - 28.8 27 31 648 144 96 150 30-34.8 82/85 19.2 - 28.8 46 58.5 1104 150 96 150 30-34.8 85/87 19.2 - 28.8 65/70 (1) 105 1560 144 96 200 30-34.8 84/88 28.8 - 43.2 30.7 39 1104 150 144 200 45-49.7 85/88 28.8 - 43.2 42/46.5(2) 70 1512 150 144 200 45-49.7 84/88 38.4 - 52.8 1.1 52.8 384 192 200 55.2-64.8 83/85 38.4 - 52.8 2.1 100.8 384 192 200 55.2-64.8 84/87 38.4 - 52.8 3.3 158.4 384 192 200 55.2-64.8 85/88 38.4 - 52.8 7 336 288 192 350 55.2-64.8 82/85 38.4 - 52.8 13 624 288 192 350 55.2-64.8 83/86 38.4 - 52.8 28 29.2 1104 300 192 200 55.2-60 86/88 38.4 - 52.8 32 1536 288 192 200 55.2-64.8 86/90 48.0 - 66.0 18.4 23.4 1104 360 240 400 69-75 85/88 (4) 200-265VAC Input, 10s maximum on time, 35% duty cycle Options Other Industrial Products Suffix Blank LZSA DPP, DLP, DSP PFE /HDA /RYHD Description No Cover (HWS50-150 Only) HWS300-1500 the cover is fitted as standard The cover option for HWS50-150 is special order only HWS300-1500 the cover is fitted as standard ISA 12.12.01 (UL1604) - Class 1 Div 2 with dry contact relay DC Good signal (300W, 600W and 1500W 24V output models only, no remote on/off function.) 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 500W to 1500W Single output 10W to 960W DIN Rail Mount 300 to 1000W AC-DC Power Models For Additional Information, please visit us.tdk-lambda.com/lp/products/hws-series.htm 64 Revision B4: Nov 2011