MA-COM SR6M4012

SCHRACK
General Purpose Relays
Safety Relay SR6 D/M
n
4 pole safety relay with either
2 NO+2 NC or 3 NO+1 NC contacts
n
Forcibly guided contacts according to EN 50205
n
Rated current 8 A
n
High insulation distances for safe separation of
electrical circuits
Applications
Emergency shut-off, press control, machine control, elevator
and escalator control, safety modules
F0206-ED
Approvals
V
REG.-Nr. 128935, Z E214024, T 968/EL 350.04/09
Technical data of approved types on request
Contact data
Contact configuration
3 NO contacts and 1 NC contact
or
2 NO contacts and 2 NC contacts
Contact set
single contact, forcibly guided
type A according to EN 50205
Type of interruption
micro disconnection
Rated voltage / max. switching voltage AC
250 / 400 VAC
Rated current
8A
Maximum breaking capacity AC
2000 VA
Contact material
AgSnO2
Minimum contact load
10 mA / 5 V
Contact resistance
w 100 mOhm / 1 A / 24 VDC
w 20 Ohm / 10 mA / 5 VDC
Rated frequency of operation with / without load
6 min-1 / 150 min-1
Contact ratings
Type Contact Load*)
EN60947-5-1
SR6
1 NO
SR6
1 NO
IEC 947-5-1 (AC15) utilization category 250 VAC / 5 A
IEC 947-5-1 (DC13) utilization category 24 VDC / 6 A
Ambient
temp. [°C]
Cycles
23°C
23°C
6,050
6,050
*) load on one pole
Coil data
Rated coil voltage range DC coil
Operative range to IEC 61810
5...110 VDC
2
Coil versions, DC-coil
Coil
Rated
Operate
Release / Reset
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
005
5
3.8
0.5
21+10%
1190
006
6
4.5
0.6
30+10%
1200
009
9
6.8
0.9
68+10%
1191
012
12
9.0
1.2
120+10%
1200
018
18
13.5
1.8
270+10%
1200
021
21
15.8
2.1
368+10%
1198
024
24
18.0
2.4
480+10%
1200
036
36
27.0
3.6
1080+10%
1200
040
40
30.0
4.0
1333+10%
1200
048
48
36.0
4.8
1920+10%
1200
060
60
45.0
6.0
3000+12%
1200
110
110
82.5
11.0
10080+12%
1200
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information only
to be used together with the
'Definitions' section in the catalogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
SCHRACK
General Purpose Relays
Safety Relay SR6 D/M (Continued)
Insulation
PCB layout / terminal assignment
Dielectric strength coil-contact circuit
3000 Vrms
open contact circuit
1500 Vrms
adjacent contact circuits 3000 / 4000 Vrms (in longitudinal direction)
Clearance / creepage coil-contact circuit
W 5.5 / 5.5 mm
adjacent contact circuits
W 5.5 / 5.5 mm
W 15 / 15 mm (in longitudinal direction)
Material group of insulation parts
IIIa
Tracking index of relay base
PTI 250
Insulation to IEC 61810-1
Type of insulation coil-contact circuit
basic
open contact circuit
micro disconnection
adjacent contact circuits reinforced (in longitudinal dir)
Rated insulation voltage
250 V
Pollution degree
2
Rated voltage system
230 / 400 V
Overvoltage category
III
Insulation to EN 50178
Type of insulation coil-contact circuit
reinforced
adjacent contact circuits
reinforced
Bottom view on solder pins
2 NO+2 NC versions
S0368-CI
S0368-CJ
Other data
Mechanical endurance
10x106 cycles
Material
RoHS - Directive 2002/95/EC
compliant as per product date code 0407
Environment
Ambient temperature range
-25...+70°C
Vibration resistance (function) NO / NC contact > 8 / 2.5 g, 10....200 Hz
Shock resistance (function) NO / NC contact > 10 / 2.5 g, 16 ms half sine
Category of protection
RT III1)
Processing
Resistance to soldering heat
260°C / 5 s
Relay weight
30 g
Packaging unit
10 pcs
1)
3 NO + 1 NC version
S0368-CK
please contact technical support for washing parameters
Accessories
PCB socket and hold down clip
contact technical support
S0368-CL
Dimensions
S0367-DB
2
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information only
to be used together with the
'Definitions' section in the catalogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
SCHRACK
General Purpose Relays
Safety Relay SR6 D/M (Continued)
Product key
Typical product key
SR6
D
4
012
Type
SR6 Safety Relay SR6 D/M
Contact configuration
D 2 NO + 2 NC contacts (2 form A + 2 form B)
M 3 NO + 1 NC contacts (3 form A + 1 form B)
Contact material
4 AgSnO2
Coil
Coil code = rated coil voltage (e.g. 024=24 VDC)
Other types on request
Product key
SR6D4012
SR6D4018
SR6D4021
SR6D4024
SR6D4040
SR6D4110
SR6M4006
SR6M4012
SR6M4018
SR6M4021
SR6M4024
SR6M4110
Type
4-pole
safety relay
Contact configuration
2 NO + 2 NC
contacts
Contact material
AgSnO2
3 NO + 1 NC
contacts
Coil
12 VDC
18 VDC
21 VDC
24 VDC
40 VDC
110 VDC
6 VDC
12 VDC
18 VDC
21 VDC
24 VDC
110 VDC
Part number
1415078-1
7-1415354-1
8-1415353-1
6-1415027-1
9-1415366-1
1415062-1
6-1415053-1
7-1415353-1
1415354-1
6-1415353-1
3-1415353-1
1-1415354-1
3
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information only
to be used together with the
'Definitions' section in the catalogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.