SCHRACK General Purpose Relays Safety Relay SR6 D/M n 4 pole safety relay with either 2 NO+2 NC or 3 NO+1 NC contacts n Forcibly guided contacts according to EN 50205 n Rated current 8 A n High insulation distances for safe separation of electrical circuits Applications Emergency shut-off, press control, machine control, elevator and escalator control, safety modules F0206-ED Approvals V REG.-Nr. 128935, Z E214024, T 968/EL 350.04/09 Technical data of approved types on request Contact data Contact configuration 3 NO contacts and 1 NC contact or 2 NO contacts and 2 NC contacts Contact set single contact, forcibly guided type A according to EN 50205 Type of interruption micro disconnection Rated voltage / max. switching voltage AC 250 / 400 VAC Rated current 8A Maximum breaking capacity AC 2000 VA Contact material AgSnO2 Minimum contact load 10 mA / 5 V Contact resistance w 100 mOhm / 1 A / 24 VDC w 20 Ohm / 10 mA / 5 VDC Rated frequency of operation with / without load 6 min-1 / 150 min-1 Contact ratings Type Contact Load*) EN60947-5-1 SR6 1 NO SR6 1 NO IEC 947-5-1 (AC15) utilization category 250 VAC / 5 A IEC 947-5-1 (DC13) utilization category 24 VDC / 6 A Ambient temp. [°C] Cycles 23°C 23°C 6,050 6,050 *) load on one pole Coil data Rated coil voltage range DC coil Operative range to IEC 61810 5...110 VDC 2 Coil versions, DC-coil Coil Rated Operate Release / Reset Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 005 5 3.8 0.5 21+10% 1190 006 6 4.5 0.6 30+10% 1200 009 9 6.8 0.9 68+10% 1191 012 12 9.0 1.2 120+10% 1200 018 18 13.5 1.8 270+10% 1200 021 21 15.8 2.1 368+10% 1198 024 24 18.0 2.4 480+10% 1200 036 36 27.0 3.6 1080+10% 1200 040 40 30.0 4.0 1333+10% 1200 048 48 36.0 4.8 1920+10% 1200 060 60 45.0 6.0 3000+12% 1200 110 110 82.5 11.0 10080+12% 1200 All figures are given for coil without preenergization, at ambient temperature +23°C Other coil voltages on request 1 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. SCHRACK General Purpose Relays Safety Relay SR6 D/M (Continued) Insulation PCB layout / terminal assignment Dielectric strength coil-contact circuit 3000 Vrms open contact circuit 1500 Vrms adjacent contact circuits 3000 / 4000 Vrms (in longitudinal direction) Clearance / creepage coil-contact circuit W 5.5 / 5.5 mm adjacent contact circuits W 5.5 / 5.5 mm W 15 / 15 mm (in longitudinal direction) Material group of insulation parts IIIa Tracking index of relay base PTI 250 Insulation to IEC 61810-1 Type of insulation coil-contact circuit basic open contact circuit micro disconnection adjacent contact circuits reinforced (in longitudinal dir) Rated insulation voltage 250 V Pollution degree 2 Rated voltage system 230 / 400 V Overvoltage category III Insulation to EN 50178 Type of insulation coil-contact circuit reinforced adjacent contact circuits reinforced Bottom view on solder pins 2 NO+2 NC versions S0368-CI S0368-CJ Other data Mechanical endurance 10x106 cycles Material RoHS - Directive 2002/95/EC compliant as per product date code 0407 Environment Ambient temperature range -25...+70°C Vibration resistance (function) NO / NC contact > 8 / 2.5 g, 10....200 Hz Shock resistance (function) NO / NC contact > 10 / 2.5 g, 16 ms half sine Category of protection RT III1) Processing Resistance to soldering heat 260°C / 5 s Relay weight 30 g Packaging unit 10 pcs 1) 3 NO + 1 NC version S0368-CK please contact technical support for washing parameters Accessories PCB socket and hold down clip contact technical support S0368-CL Dimensions S0367-DB 2 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. SCHRACK General Purpose Relays Safety Relay SR6 D/M (Continued) Product key Typical product key SR6 D 4 012 Type SR6 Safety Relay SR6 D/M Contact configuration D 2 NO + 2 NC contacts (2 form A + 2 form B) M 3 NO + 1 NC contacts (3 form A + 1 form B) Contact material 4 AgSnO2 Coil Coil code = rated coil voltage (e.g. 024=24 VDC) Other types on request Product key SR6D4012 SR6D4018 SR6D4021 SR6D4024 SR6D4040 SR6D4110 SR6M4006 SR6M4012 SR6M4018 SR6M4021 SR6M4024 SR6M4110 Type 4-pole safety relay Contact configuration 2 NO + 2 NC contacts Contact material AgSnO2 3 NO + 1 NC contacts Coil 12 VDC 18 VDC 21 VDC 24 VDC 40 VDC 110 VDC 6 VDC 12 VDC 18 VDC 21 VDC 24 VDC 110 VDC Part number 1415078-1 7-1415354-1 8-1415353-1 6-1415027-1 9-1415366-1 1415062-1 6-1415053-1 7-1415353-1 1415354-1 6-1415353-1 3-1415353-1 1-1415354-1 3 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change.