COSMO KTLP3617S

PRODUCT SPECIFICATION
DATE:07/31/2008
cosmo
Power Photo TRIAC:
ELECTRONICS CORPORATION
KTLP3617S
61P46003
SHEET 1 OF 6
Photo Coupler for
Power Photo TRIAC Output
z Features
1. Compact dual-in-line package.
2. 600V peak blocking voltage.
3. Isolation voltage between input and output 5000Vrms.
z Application:
1.
2.
3.
4.
TRIAC Driver.
Programmable Controllers.
AC-Output Module.
Solid State Relay.
REV.
4
PRODUCT SPECIFICATION
DATE:07/31/2008
cosmo
61P46003
Power Photo TRIAC:
KTLP3617S
ELECTRONICS CORPORATION
SHEET 2 OF 6
REV.
4
z Outside dimension:Unit ( mm )
3617
XXX
Date Code
Tolerance:±0.2mm
z Schematic:Top View
1
8
2
3
4
ZC
6
5
1. Cathode
2. Anode
3. Cathode
4. Cathode
5. Gate
6. T1
8. T2
PRODUCT SPECIFICATION
DATE:07/31/2008
61P46003
Power Photo TRIAC:
cosmo
ELECTRONICS CORPORATION
KTLP3617S
SHEET 3 OF 6
REV.
4
z Absolute Maximum Ratings
Parameter
Input
Output
Symbol
Rating
Unit
Forward current
IF
50
mA
Peak forward current
IFP
1
A
Reverse voltage
VR
6
V
Off-State Output Terminal voltage
VDRM
600
V
On-State R.M.S. Current
IT(RMS)
1.2
A
Peak Nonrepetitive Surge Current
( 60Hz, Peak )
ITSM
10
A
Isolation voltage ( AC, 1 minute )
Viso
5000
Vrms
Operating temperature
Topr
-40 to +85
℃
Storage temperature
Tstg
-40 to +125
℃
Soldering temperature 10 second
Tsol
260
℃
z Electro-optical Characteristics
Parameter
Input
Output
Symbol
Conditions
Forward voltage
VF
IF = 10mA
-
1.2
1.4
V
Reverse current
IR
VR = 6V
-
-
10
μA
Peak Blocking Current
IDRM
VDRM = Rated
-
-
100
μA
On-State Voltage
VTM
IT = 1.2A
-
-
3
V
Holding Current
IH
VD = 5V
-
-
25
mA
dV/dt
VDRM = (1/ 2 )‧Rated
600
1000
-
V/μs
VINH
IF = Rated IFT
-
-
50
V
IDRM2
IF = Rated IFT, Rated VDRM,
Off State
-
200
-
μA
Riso
DC500V
5×1010
-
-
Ω
IFT
VD = 5V
-
-
10
mA
Critical rate of rise of
Off-state voltage
Inhibit voltage ( MT1-MT2 Voltage
above which device not trigger )
Transfer Leakage in Inhibited State
characteristics Isolation resistance
Minimum trigger current
MIN. TYP. MAX. Unit
PRODUCT SPECIFICATION
DATE:07/31/2008
61P46003
Power Photo TRIAC:
cosmo
KTLP3617S
ELECTRONICS CORPORATION
SHEET 4 OF 6
IF vs. Ta
IT vs. Ta
On-State R.M.S. Current IT ( A )
50
40
30
20
10
Trigger Current IFT ( mA )
0
20
40
60
80
100
1.2
1.0
0.8
0.6
0.4
0.2
-20
0
20
40
60
80
100
Ambient Temperature Ta ( ℃ )
Ambient Temperature Ta ( ℃ )
IFP vs. Duty Ratio
IF vs. VF
10000
Forward current IF ( mA )
Peak forward current IFP ( mA )
-20
Ta=25°C
1000
100
-3
-2
10
200
-1
10
10
1
Ta=75°
50°
100
50
25°
0°
-25°
20
10
5
2
0
0.5
1.0
1.5
2.0
2.5
Duty ratio
Forward voltage VF ( V )
IFT vs. Ta
VINH vs. Ta
Normalized To Ta=25°C
6.2
6.0
5.8
5.6
5.4
5.2
5.0
4.8
4.6
4.4
4.2
4.0
3.8
3.6
-40 -20
500
1
0
0
20
40
60
80 100 120
Ambient Temperature Ta ( ℃ )
Inhibit Voltage VINH ( V )
Forward current IF ( mA )
60
9.5
9.0
8.5
8.0
7.5
7.0
6.5
6.0
5.5
5.0
4.5
4.0
3.5
3.0
-40 -20
3.0
Normalized To Ta=25°C
0
20
40
60
80 100 120
Ambient Temperature Ta ( ℃ )
REV.
4
PRODUCT SPECIFICATION
DATE:07/31/2008
61P46003
Power Photo TRIAC:
cosmo
KTLP3617S
ELECTRONICS CORPORATION
SHEET 5 OF 6
On-State Current ITM ( A )
+1.2
IF=10mA,Ta=25°C
+1.0
+0.8
+0.6
0
-0.6
-0.8
-1.0
-1.2
-1.5 -1.0 -0.5
0
IDRM vs. Ta
Peak Blocking Current IDRM ( nA )
ITM vs. VTM
IF=0,VDRM=Rated
1000
500
200
100
50
-40 -20 0 20 40 60 80 100
+0.5 +1.0 +1.5
On-State Voltage VTM ( V )
Ambient Temperature Ta ( ℃ )
REV.
4
PRODUCT SPECIFICATION
DATE:07/31/2008
cosmo
ELECTRONICS CORPORATION
61P46003
Power Photo TRIAC:
KTLP3617S
SHEET 6 OF 6
z NOTICE
The information contained in this document is intended to be a
general product description and is subject to change without notice.
Please contact cosmo in order to obtain the latest device data sheets
before using any cosmo device. cosmo does not assume any
responsibility for use of any circuitry described. No circuit patent
licenses are implied. This publication is the property of cosmo. No
part of this publication may be reproduced or copied in any form or by
any means, or transferred to any third party without the prior written
consent of cosmo Electronics Corporation.
The devices listed in this document are designed for general
applications only in electronic equipment. No devices shall be
deployed which require higher level of reliability such as:
–
–
–
–
Medical and other life support equipments.
Space application.
Telecommunication equipment ( trunk lines ).
Nuclear power control equipment.
Unless it received prior written approval from cosmo.
cosmo takes no responsibility for damages arise form the
improper usage of our device. Please contact cosmo for further
information regarding the above notices.
REV.
4