CUI VBM-100-48-H

date
07/17/2013
page
1 of 4
SERIES: VBM-100 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
•
•
up to 100 W isolated output
baseplate cooling
active PFC meets EN61000-3-2 Class D
17mm ultra low profile encapsulated packaging
universal input (90~264 Vac)
no load power consumption < 0.5 W
single output from 12~48 Vdc
4,242 Vdc isolation
wide operating temperature range (-20°C~85°C)
over temperature, over voltage, and short circuit protections
high efficiency up to 92%
RoHS
output
voltage
output
current
output
power
ripple
and noise1
efficiency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VBM-100-12
12
8.4
100
120
90
VBM-100-24
24
4.2
100
240
91
VBM-100-28
28
3.6
100
280
91
VBM-100-36
36
2.8
100
360
91
VBM-100-48
48
2.1
100
480
92
MODEL
Notes:
1. ripple and noise are measured at 20 MHz BW with 10μF electrolytic capacitor and 0.1μF ceramic capacitor across output
PART NUMBER KEY
VBM-100 - XX - X
Base Number
Output Voltage
cui.com
Heatsink
"blank" = No
H = Yes
CUI Inc │ SERIES: VBM-100 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/17/2013 │ page 2 of 4
INPUT
parameter
conditions/description
min
voltage
typ
90
frequency
47
max
units
264
Vac
63
Hz
inrush current
at 240 Vac
100
A
leakage current
at 264 Vac
3.5
mA
0.5
W
no load power consumption
OUTPUT
parameter
conditions/description
line regulation
high line to low line, full load
min
load regulation
voltage accuracy
typ
max
units
±0.5
%
60% ±40% rated load
±1
%
set at 60% rated load and 25°C
±1
%
hold-up time
16
ms
130
kHz
±0.05
%/°C
switching frequency
temperature coefficient
PROTECTIONS
parameter
conditions/description
over voltage protection
recycle ac input to restart
short circuit protection
hiccup mode, recovers automatically
over temperature protection
auto recovery
min
typ
max
units
min
typ
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
input to output
4,242
Vdc
safety approvals
IEC 60950-1, EN 60950-1, UL 60950-1
EMI/EMC
EN 55022 Class B, FCC Part 15 Class B, EN 61000-6-(1,3), EN 61000-3-(2,3), EN 55024, EN 61204-3
RoHS compliant
yes
ENVIRONMENTAL
parameter
conditions/description
operating temperature
see derating curves
min
storage temperature
humidity
typ
-20
85
°C
100
°C
93
%
DERATING CURVES
230 Vac
115 Vac
115 Vac w/
heat sink
230 Vac w/
heat sink
Rated Load (%)
80
60
40
20
0
-20
-10
0
10
20
30
40
50
Ambient Temperature (°C)
cui.com
60
units
-40
non-condensing
100
max
70
80
85
90
CUI Inc │ SERIES: VBM-100 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/17/2013 │ page 3 of 4
MECHANICAL
parameter
conditions/description
dimensions
4.598 x 2.402 x 0.669 (116.80 x 61.00 x 17.00 mm)
min
weight
without heatsink
typ
max
units
inch
220
0.5
g
lbs
MECHANICAL DRAWING
units: inch[mm]
tolerance: inches: x.xx = ±0.02, x.xxx = ±0.010
mm: x.x = ±0.5, x.xx = ±0.25
PIN CONNECTIONS
PIN
FUNCTION
1
AC(L)
2
AC(N)
3
FG
4
+Vout
5
-Vout
HEATSINK
units: mm
25.4
2.7
8
8
1.4
6- R
1. 0
5
4
0.
-R
10 0. 2
R
4-
8
8
32
+0
50.8±0.1
61 -0.1
5.4
9.6
5.05
14.5
5.1
106.7±0.1
.9
R0
2-
116.8 +0
-0.1
8
2.1
0.30
1.8
cui.com
9.6
0.5
4.2
.8
R0
2-
All specifications measured at: Ta=25°C, 230 Vac input voltage and 60% rated output load, unless otherwise specified.
3. 3
90°
4-
CUI Inc │ SERIES: VBM-100 │ DESCRIPTION: AC-DC POWER SUPPLY
date 07/17/2013 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
06/10/2013
1.01
updated derating curves
07/08/2013
1.02
added features
07/17/2013
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.