1400 Series Phase Sensor 115 or 208Vac, 60 or 400 Hz., Relay Output Product Facts ■ ■ ■ ■ ■ ■ ■ Phase sensor for 115 or 208Vac, 60 or 400 Hz. Up to 2A loads Static and motor load types Hermetic package Built to MIL-R-83726 environmentals Various applications ■ Motor protection ■ Brown-out protection ■ Power supply sequencing ■ Air conditioner protection ■ Ground support equipment protection Many customizing options ■ 50 Hz. input types ■ Contact ratings to 10A ■ Higher voltages ■ Different packages, headers and mounting Electrical Specifications Input Data: Voltage: 115 or 208Vac. Frequency: 60 or 400 Hz. Operate Time (Max.) : 75 ms. Release Time (Max.) : 100 ms. Contact Arrangement: 1 Form C (SPDT). Contact Ratings: 2A resistive @ 30Vdc. 0.5A inductive @ 30Vdc. 0.25A resistive or inductive @ 115 Vrms, 60 or 400 Hz. CII 1400 series phase sensors combine solid state sensing circuits with electromechanical output relays in robust hermetically sealed enclosures. P-Type models are for static loads. With the line voltage and frequency are within operating limits, P-Type units will energize only when input phases are in sequence A-B-C. They will deenergize only when power is removed. The P-Type unit is the voltage input to the unit is below 50% of the nominal phase-to-phase voltage input. Q-Type units are suitable for motor loads where regenerated voltage is produced. Neither P-Type nor Q-Type units require connection to the neutral leg. For high-current applications, phase sensors are used with slave relays having heavy duty contact ratings. Specifications by Model Number Fixed Timer Model Number 1407 1408 1409 1410 1437 1438 1439 1440 Load Type P P P P Q Q Q Q Line to Line Voltage ±10% 115V 115V 208V 208V 115V 115V 208V 208V Frequency ±10% 60 Hz. 400 Hz. 60 Hz. 400 Hz. 60 Hz. 400 Hz. 60 Hz. 400 Hz. THREE PHASE SOURCE LOAD Mounting Style Figure 3 1 or 3 3 3 2 3 4 4 ØA INPUT Ø B ØC START N.O. STOP N.C. Max. Power Required 4 Watts 4 Watts 6 Watts 6 Watts 6 Watts 6 Watts 9 Watts 9 Watts Wiring Diagram Typical Applications Connections Environmental Specifications Temperature Range: -55°C to +85°C. Vibration: 20 G’s, 10 - 2,000 Hz. Shock: 50 G’s, 11 ± 1ms duration. Insulation Resistance: 1,000 megohms, min., at 500Vdc. Dielectric Strength: 1,000Vrms, 60 Hz., at sea level, all terminals to case. Sealing: Hermetic, 1.3 in. (33.0mm) of mercury. Life: 100,000 operations, min. Weight: 12 oz (340g) max. best suited to applications where static loads are used and where regenerated voltage will not be present if a phase opens. Q-Type units perform the same function as the P-Type since they will energize only when input phases are in sequence A-B-C. In addition, the Q-Type unit will de-energize when any phase is disconnected or grounded, provided OUTPUT MAIN CONTACTOR PHASE SENSOR CONTACT CLOSED ONLY WHEN PHASE SEQUENCE IS CORRECT Part Numbering System Typical Part Number Model Number: Four digit code from table above. Output: 1 = 1 Form C (SPDT) Mounting (see outline dimension drawings): A = Studs on bottom B = Studs on top, except bracket on bottom for 1439 and 1440 1408 –1 A C = Studs on side A typical part number would be 1408–1A. This is a 115Vac, 400 Hz., “P” type phase sensor with a 1 form C (SPDT) contact arrangement in a style “A” mounting. © 2006 by Tyco Electronics Corporation. All Rights Reserved. CII and TYCO are trademarks. Other products and company names mentioned herein may be trademarks of their respective owners. 1 Catalog 7-1773439-6 Revised 1-06 www.tycoelectronics.com Dimensions are in inches and millimeters unless otherwise specified. Values in brackets are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-5-729-0425 South America: 55-11-3611-1514 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-141-810-8967 High Performance Electronic Products 1400 Series Phase Sensors (Continued) Outline Dimensions Figure 2 Applicable to 1437 Figure 1 Applicable to 1408 .625 [15.875] #8-32 N.C. - 2A 4 STUDS 2.0625 [52.39] MAX. 2.375 [60.32] MAX. SEATED HEIGHT 1.25 [31.75] 2.00 [50.8] MAX. .625 [15.875] INDEX DOT #6-32 N.C.-2A 4 STUDS 1.188 [30.16] .344 [8.73] #6-32 N.C.-2A 3 STUDS #8-32 N.C. - 2A 4 STUDS .844 [21.4] .25 [6.35] 1.25 [31.75] MAX. SEATED HEIGHT .75 [19.05] Mounting Option C 2.00 2.563 [50.8] [65.09] 2.0 [50.8] Mounting Option B Figure 4 Applicable to 1439 and 1440 Figure 3 Applicable to 1407, 1409, 1410, 1438 and 1408 “B” revision only 2.25 [57.15] MAX. 2.64 [67.1] MAX. .625 [15.875] #6-32 N.C. - 2A 4 STUDS 2.50 [63.5] MAX. SEATED HEIGHT 2.188 [55.56] MAX. 1.89 ± .030 [48.0 ± .762] .375 [9.53] INDEX DOT 1.250 [31.75] #6-32 N.C. - 2A 4 STUDS 1.25 [31.75] .750 [19.05] 1.750 [44.45] 1.250 [31.75] 1.740 [44.2] MAX. INDEX DOT .500 [12.7] .25 [6.35] 1.250 [31.75] .750 [19.05] 1.750 [44.45] .710 [18.0] MAX. #6-32 N.C.- 2A 3 STUDS .375 [9.53] INDEX DOT 2.25 ± .010 [57.15 ± .254] 1.25 [31.75] .625 [15.875] .250 [6.35] .25 [6.35] 1.188 [30.18] .750 [19.05] Mounting Option A .375 [9.53] INDEX DOT 1.188 [30.18] .656 .750 [16.7] [19.05] 2.563 [65.09] INDEX DOT .844 [21.4] INDEX DOT .656 [16.7] .75 [19.05] 1.188 [30.16] Mounting Option A 2.375 [60.32] .25 [6.35] .375 [9.53] .375 [9.53] .344 [8.73] 1.813 [46.05] MAX. SEATED HEIGHT 1.250 [31.75] 4.00 [102] MAX. INDEX DOT .650 [16.5] MAX. 1.25 [31.75] .045 [1.14] Mounting Option A 2 Catalog 7-1773439-6 Revised 1-06 www.tycoelectronics.com Mounting Option B Dimensions are in inches and millimeters unless otherwise specified. Values in brackets are metric equivalents. Mounting Option C Dimensions are shown for reference purposes only. Specifications subject to change. USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-5-729-0425 Mounting Option B South America: 55-11-3611-1514 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-141-810-8967