G100EI Series Low Cost, 1W MiniDIP High Isolation DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 1W Output Power • Compact “MiniDIP” Case • 3,000 VDC Isolation Input Parameter Input Voltage Range • UL Approved (File E245422) Input Filter • Single & Dual Outputs Reverse Polarity Input Current • >3.5 MHour MTBF Output • 24 Standard Models Parameter • LOWEST COST!! Conditions Min. Typ. Max. 5 VDC Input 4.5 5.0 5.5 12 VDC Input 10.8 12.0 13.2 24 VDC Input 21.6 24.0 26.4 Line Regulation Load Regulation (Note 1) Conditions Min. 0.3 A Units Typ. Max. ±1.0 ±3.0 % Dual Output , Balanced Loads ±0.1 ±1.0 % For Vin Change of 1% ±1.2 % See Model Selection Guide Ripple & Noise (20 MHz) (Note 2) Output Power Protection 50 75 mV P - P ±0.02 ±0.03 %/ºC Max. Units 120 Temperature Coefficient Output Short Circuit RoHS Compliant VDC Internal Capacitor Output Voltage Accuracy Output Voltage Balance Units % Momentary (1.0 Sec.) General Parameter Conditions Isolation Voltage Isolation Resistance Isolation Capacitance Min. 60 Seconds 3,000 500 VDC 1,000 100 kHz, 1V Switching Frequency Typ. VDC MΩ 60 pF 150 kHz Environmental Parameter Conditions Operating Temperature Range Ambient Storage Temperature Range Typ. Max. -40 +25 +85 ºC +125 ºC 95 % -55 Cooling Humidity Min. Units Free Air Convection RH, Non-condensing Physical MicroPower Direct Case Size 292 Page Street Suite D Stoughton, MA 02072 USA Case Material T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com MTBF 0.80 x 0.40 x 0.25 Inches (20.4 x 10.2 x 6.5 mm) Non-Conductive Black Plastic (UL94-V0) Weight 0.07 Oz (2.1g) Reliability Specifications Parameter Conditions Min. MIL HDBK 217F, 25ºC, Gnd Benign Typ. Max. 3.5 Units MHours Safety Standards UL 1950, EN 60950, IEC 60950 Safety Approvals UL, cUL; File No. E245422 Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Conditions Min. Typ. Max. 5 VDC Input -0.7 9.0 12 VDC Input -0.7 18.0 24 VDC Input -0.7 30.0 Units VDC 1.5 mm From Case For 10 Sec 300 ºC All Models 450 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Model Selection Guide Model Number G101EI G102EI G103EI G104EI G105EI G106EI G107EI G108EI G111EI G112EI G113EI G114EI G115EI G116EI G117EI G118EI G121EI G122EI G123EI G124EI G125EI G126EI G127EI G128EI Input Output Load Voltage (VDC) Current (mA) Regulation Voltage Current Current Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max) 5 4.5 - 5.5 286 30 5.0 200.0 20.0 15 5 4.5 - 5.5 267 30 9.0 111.0 12.0 15 5 4.5 - 5.5 256 30 12.0 83.0 9.0 15 5 4.5 - 5.5 250 30 15.0 67.0 7.0 15 5 4.5 - 5.5 278 30 ±5.0 ±100.0 ±10.0 15 5 4.5 - 5.5 267 30 ±9.0 ±56.0 ±6.0 15 5 4.5 - 5.5 256 30 ±12.0 ±42.0 ±5.0 15 5 4.5 - 5.5 253 30 ±15.0 ±33.0 ±4.0 15 12 10.8 - 13.2 115 15 5.0 200.0 20.0 15 12 10.8 - 13.2 110 15 9.0 111.0 12.0 15 12 10.8 - 13.2 105 15 12.0 83.0 9.0 15 12 10.8 - 13.2 103 15 15.0 67.0 7.0 15 12 10.8 - 13.2 113 15 ±5.0 ±100.0 ±10.0 15 12 10.8 - 13.2 110 15 ±9.0 ±56.0 ±6.0 15 12 10.8 - 13.2 105 15 ±12.0 ±42.0 ±5.0 15 12 10.8 - 13.2 104 15 ±15.0 ±33.0 ±4.0 15 24 21.6 - 26.4 57 8 5.0 200.0 20.0 15 24 21.6 - 26.4 54 8 9.0 111.0 12.0 15 24 21.6 - 26.4 52 8 12.0 83.0 9.0 15 24 21.6 - 26.4 51 8 15.0 67.0 7.0 15 24 21.6 - 26.4 56 8 ±5.0 ±100.0 ±10.0 15 24 21.6 - 26.4 55 8 ±9.0 ±56.0 ±6.0 15 24 21.6 - 26.4 52 8 ±12.0 ±42.0 ±5.0 15 24 21.6 - 26.4 51 8 ±15.0 ±33.0 ±4.0 15 Efficiency (%, Typ) 70 75 78 80 72 75 78 79 72 76 79 81 74 76 79 80 73 77 80 82 74 76 80 81 Fuse Rating Slow-Blow (mA) 500 500 500 500 500 500 500 500 200 200 200 200 200 200 200 200 100 100 100 100 100 100 100 100 Derating Curve Other input/output combinations are available (i.e 3.3 VDC). Contact the factory for details at: [email protected] Notes: 1. Output load regulation is specified for a load change of 10% to 100%. 2. These units should not be operated with a load under 10% of full load. Operation at no-load may cause damage to the unit. 3. These converters will operate without external components. However, when measuring output ripple, it is recommended that an external ceramic capacitor be placed Output Capacitor Input from the +Vout pin to Vin Vout Capacitor Single Dual the -Vout pin for single output units and from 5 VDC 4.7 μF 5 VDC 10.0 μF 4.7 μF each output to common 12 VDC 2.2 μF 9 VDC 4.7 μF 2.2 μF for dual output units. 24 VDC 1.0 μF 12 VDC 2.2 μF 1.0 μF An input capacitor will 15 VDC 1.0 μF 0.47 μF enhance stability over Mechanical Dimensions temperature and input line variations. Recommended capacitor values are given in the table above. For applications requiring very low output noise levels, a simple LC filter should be effective. 4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Pin Connections Pin Single Dual 1 -Vin -Vin 7 NC NC 8 +Vout +Vout NC= No Connection Pin Single Dual 9 10 14 No Pin -Vout +Vin Common -Vout +Vin Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the side of the unit MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]