LOW CURRENT T-100 & T-1 3/4 SOLID STATE LAMPS ABSOLUTE MAXIMUM RATING (TA =25°C) Parameter HER YELLOW GREEN UNITS Power Dissipation (derated from 92°C at 1mA/°C) 27 24 27 mW Peak Forward Current (PW ≤ 1 ms, DF ≤ 30 %) 25 20 25 mA Continuous Forward Current 7.5 7.5 7.5 mA Lead Soldering Time at 260° C 5 5 5 sec Reverse Breakdown Voltage (V) 5 5 5 IR = 100µA Operating Temperature -55 to +100 -55 to +100 -55 to +100 °C Storage Temperature -55 to +100 -55 to +100 -55 to +100 °C ELECTRICAL / OPTICAL CHARACTERISTICS (TA =25°C) HER YELLOW Parameter HLMP-1700/4700HLMP-1719/4719Luminous Intensity (mcd) Minimum 1.0/1.2 1.0/1.2 Typical 2.0/2.0 2.0/2.0 Forward Voltage (V) Maximum 2.2 2.7 Typical 1.8 1.9 Peak Wavelength (nm) 635 585 Spectral Line Half Width 45 35 Viewing Angle (°) 50/35 50/35 GREEN HLMP-1790/4740(MV2454)1.0/1.2 2.0/3.0 2.7 1.9 565 30 50/35 Condition IF = 2mA IF = 2mA IF = 2mA IF = 2mA IF = 2mA LOW CURRENT T-100 & T-1 3/4 SOLID STATE LAMPS DISCLAIMER FAIRCHILD SEMICONDUCTOR RESERVES THE THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS. LIFE SUPPORT POLICY FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or 2. A critical component in any component of a life support systems which, (a) are intended for surgical device or system whose failure to perform can be implant into the body,or (b) support or sustain life, reasonably expected to cause the failure of the life and (c) whose failure to perform when properly support device or system, or to affect its safety or effectiveness. used in accordance with instructions for use provided in labeling, can be reasonably expected to result in a significant injury of the user. http\\:www.everlight.com © 2006 Everlight Electronics Co., Ltd