AC Relays HARTMAN Aerospace Power Products Features: • 2PST N.O. Main Contacts • 115 VAC Coil • 115 VAC, 60 Hz • 60 Amps • High Reliability • Meets many requirements of MIL-R-6106 • Light Weight Construction BR-329BC 2PST N.O., 60 Amps, 115 VAC, 60 Hz CONTACTOR CONFIGURATION Notes: Dimensions for this product are expressed in inches. Multiply values by 25.4 for millimeters. PRODUCT SPECIFICATIONS Construction Main Contacts: Configuration Voltage (Nominal) Current (Resistive) Coil Data: Duty Cycle Voltage (Nominal) Pick-Up Voltage Drop-Out Voltage Coil Current @ 115 VAC & +25°C Operating Temperature Life: Electrical Mechanical Weight Gasket Sealed, Vented 2PST N.O. 115 VAC, 60 Hz 60 Amps Continuous 115 VAC, 60 Hz 90 VAC 5 - 45 VAC 0.107 Amps Maximum -55°C to +71°C 50,000 Cycles 100,000 Cycles 1 Lb. For factory-direct application assistance, contact the HARTMAN product team at (419) 521-9500, Fax (419) 526-2749. © 2004 by Tyco Electronics Corporation. All Rights Reserved. HARTMAN and TYCO are trademarks. Catalog (web doc only) Revised 5-04 www.tycoelectronics.com Dimensions are in inches and millimeters unless otherwise specified. Values in brackets are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA: 1-800-522-6752 Canada: 1-905-470-4425 Mexico: 01-800-733-8926 C. America: 52-55-5-729-0425 South America: 55-11-3611-1514 Hong Kong: 852-2735-1628 Japan: 81-44-844-8013 UK: 44-141-810-8967