D5V0F2U3LP 2 CHANNEL LOW CAPACITANCE TVS DIODE ARRAY Product Summary Features VBR (min) 6V IPP (max) 1.5A CT (typ) 0.5pF Low Profile Package (0.53mm max) and Ultra-small PCB Footprint Area (1.08 x 0.68mm max) Suitable for Compact Portable Electronics Description Provides ESD Protection per IEC 61000-4-2 Standard: Air ±15kV, Contact ±15kV This new generation TVS is designed to protect sensitive electronics from the damage due to ESD. The combination of small size and high Low Channel Input Capacitance ESD surge capability makes it ideal for use in portable applications Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2) such as cellular phones, digital cameras, and MP3 players. Halogen and Antimony Free. “Green” Device (Note 3) Applications Mechanical Data Cellular Handsets Portable Electronics Computers and Peripheral 2 Channels of ESD Protection Case: X1-DFN1006-3 Case Material: Molded Plastic, “Green” Molding Compound. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Terminals: NiPdAu over Copper leadframe. Solderable per MILSTD-202, Method 208 e4 Weight: 0.001 grams (approximate) X1-DFN1006-3 Bottom View Device Schematic Ordering Information (Note 4) Product D5V0F2U3LP-7B Notes: Compliance Standard Marking Q1 Reel Size (inches) 7 Tape Width (mm) 8 Quantity per Reel 10,000/Tape & Reel 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. 2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green" and Lead-free. 3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. 4. For packaging details, go to our website at http://www.diodes.com/products/packages.html. Marking Information Q1 Q19 = Product Type Marking Code Top View Bar Denotes Cathode Side D5V0F2U3LP Document number: DS36742 Rev. 1 - 2 1 of 4 www.diodes.com April 2014 © Diodes Incorporated D5V0F2U3LP Maximum Ratings (@TA = +25°C, unless otherwise specified.) Characteristic Peak Pulse Current ESD Protection – Contact Discharge ESD Protection – Air Discharge Symbol IPP VESD_Contact VESD_Air Value 1.5 ±15 Unit A kV Conditions 8/20µs (Note 7) Standard IEC 61000-4-2 ±15 kV Standard IEC 61000-4-2 Thermal Characteristics Characteristic Power Dissipation (Note 5) Thermal Resistance, Junction to Ambient TA = +25°C Operating and Storage Temperature Range Symbol PD RθJA TJ, TSTG Value 300 417 -55 to +150 Unit mW C/W C Electrical Characteristics (@TA = +25°C, unless otherwise specified.) Characteristic Reverse Standoff Voltage Channel Leakage Current (Note 6) Reverse breakdown voltage Clamping Voltage, Positive Transients (Note 7) Channel Input Capacitance (Note 8) Dynamic Resistance Notes: Symbol VRWM IR VBR VC Min — — 6.0 — Typ — — — 10 Max 5.5 100 — 12 — 0.5 — — 0.4 0.65 — 0.9 — pF CT RDYN Unit V nA V V Ω Test Conditions VR = 5V, Any I/O to GND IR = 1mA IPP = 1A, tp = 8/20μs VR = 0V, f = 1MHz, Any I/O to GND VR = 2.5V, f = 1MHz, Any I/O to GND IPP = 1A, tp = 8/20μs 5. Device mounted on FR-4 PCB pad layout (2oz copper) as shown on Diodes, Inc. suggested pad layout AP02001, which can be found on our website at http://www.diodes.com. 6. Short duration pulse test used to minimize self-heating effect. 7. Clamping voltage value is based on an 8x20µs peak pulse current (Ipp) waveform. 8. Measured from any I/O to GND. 9. For information on the impact of Diodes' USB 2.0 compatible ESD protectors on signal integrity including eye diagram plots, please refer to AN77 at the following URL: http://www.diodes.com/destools/appnote_dnote.html. 250 100 225 PEAK PULSE DERATING % OF PEAK POWER OR CURRENT PD, POWER DISSIPATION (mW) Note 5 200 175 150 125 100 75 50 75 50 25 25 0 0 0 25 50 150 75 100 125 TA, AMBIENT TEMPERATURE (°C) Figure 1 Power Derating Curve D5V0F2U3LP Document number: DS36742 Rev. 1 - 2 175 2 of 4 www.diodes.com 0 25 50 75 100 125 150 175 200 TA, AMBIENT TEMPERATURE (°C) Figure 2 Pulse Derating Curve April 2014 © Diodes Incorporated 100 IF, INSTANTANEOUS FORWARD CURRENT (mA) IPP, PEAK PULSE CURRENT (%Ipp) D5V0F2U3LP Peak Value Ipp Half Value Ipp/2 50 0 8x20 Waveform as defined by R.E.A. 20 0 60 40 t, TIME (s) Figure 3 Pulse Waveform 1000 100 TA = 150°C 10 TA = 125°C TA = 85°C 1 TA = 25°C TA = -55°C 0.1 0.01 300 400 500 600 700 800 900 1000 1100 VF, INSTANTANEOUS FORWARD VOLTAGE (mV) Figure 4 Typical Forward Characteristics 100 0.6 f = 1MHz Note 88 Note CT, TOTAL CAPACITANCE (pF) IR, LEAKAGE CURRENT (nA) 0.55 0.45 TA = 150°C 10 0.4 0.35 T A = 125°C TA = 85°C 0.3 0.25 TA = 25°C TA = -55°C 0.2 0.15 1 0 0.5 0.1 0 1 2 3 4 5 5.5 VR, REVERSE VOLTAGE (V) Figure 5 Typical Reverse Characteristics 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 VR, REVERSE VOLTAGE (V) Figure 6 Total Capacitance vs. Reverse Voltage Package Outline Dimensions Please see AP02002 at http://www.diodes.com/datasheets/ap02002.pdf for latest version. A A1 D b1 E e b2 L2 D5V0F2U3LP Document number: DS36742 Rev. 1 - 2 L3 DFN1006-3 Dim Min Max Typ A 0.47 0.53 0.50 A1 0 0.05 0.03 b1 0.10 0.20 0.15 b2 0.45 0.55 0.50 D 0.95 1.075 1.00 E 0.55 0.675 0.60 e 0.35 L1 0.20 0.30 0.25 L2 0.20 0.30 0.25 L3 0.40 All Dimensions in mm L1 3 of 4 www.diodes.com April 2014 © Diodes Incorporated D5V0F2U3LP Suggested Pad Layout C Dimensions Z G1 G2 X X1 Y C X1 X G2 G1 Y Value (in mm) 1.1 0.3 0.2 0.7 0.25 0.4 0.7 Z IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the final and determinative format released by Diodes Incorporated. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright © 2014, Diodes Incorporated www.diodes.com D5V0F2U3LP Document number: DS36742 Rev. 1 - 2 4 of 4 www.diodes.com April 2014 © Diodes Incorporated