SR5200 5.0 AMP SCHOTTKY BARRIER RECTIFIERS VOLTAGE RANGE 200 Volts CURRENT 5.0 Amperes FEATURES * Low forward voltage drop * High current capability * High reliability * High surge current capability * Epitaxial construction DO-27 .220(5.6) .197(5.0) DIA. 0.944(24.0) MIN. MECHANICAL DATA * Case: Molded plastic * Epoxy: UL 94V-0 rate flame retardant * Lead: Axial leads, solderable per MIL-STD-202, method 208 guranteed * Polarity: Color band denotes cathode end * Mounting position: Any * Weight: 1.10 grams .375(9.5) .285(7.2) .052(1.3) .043(1.1) DIA. 0.944(24.0) MIN. Dimensions in inches and (millimeters) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating 25 C ambient temperature uniess otherwies specified. Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. TYPE NUMBER SR5200 UNITS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current 200 140 200 V V V at Tc=100 C Peak Forward Surge Current, 8.3 ms single half sine-wave 5.0 A superimposed on rated load (JEDEC method) Maximum Instantaneous Forward Voltage at 5.0A Maximum DC Reverse Current Ta=25 C 120 A V mA at Rated DC Blocking Voltage Typical Junction Capacitance (Note1) Typical Thermal Resistance RqJA (Note 2) Operating Temperature Range TJ Storage Temperature Range TSTG 0.9 0.05 10 250 Ta=100 C -65 -65 12 +150 +150 mA PF C/W C C NOTES: 1. Measured at 1MHz and applied reverse voltage of 4.0V D.C. 2. Thermal Resistance Junction to Ambient Vertical PC Board Mounting 0.5"(12.7mm) Lead Length. REVISE FOR LEAD WIRE LENGTH TO 24.0mm AND DIAMETER FROM 1.2mm TO 1.1mm EFFECTED : 2007/6/1 RATING AND CHARACTERISTIC CURVES (SR5200) FIG.1-TYPICAL FORWARD CURRENT DERATING CURVE FIG.2-TYPICAL FORWARD 50 5.0 4.0 3.0 2.0 1.0 0 0 20 40 60 80 100 120 140 160 180 200 CASE TEMPERATURE,( C) FIG.3-MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT INSTANTANEOUS FORWARD CURRENT,(A) AVERAGE FORWARD CURRENT,(A) CHARACTERISTICS 6.0 10 3.0 1.0 Tj=25 C Pulse Width 300us 1% Duty Cycle 0.1 PEAK FORWARD SURGE CURRENT,(A) 150 .01 120 .1 .3 .5 .7 .9 1.1 1.3 1.5 FORWARD VOLTAGE,(V) 90 8.3ms Single Half Tj=25 C Sine Wave 60 JEDEC method 30 FIG.5 - TYPICAL REVERSE CHARACTERISTICS 0 1 5 50 10 100 100 NUMBER OF CYCLES AT 60Hz REVERSE LEAKAGE CURRENT, (mA) FIG.4-TYPICAL JUNCTION CAPACITANCE JUNCTION CAPACITANCE,(pF) 700 600 500 400 300 200 10 Tj=75 C 1.0 .1 Tj=25 C 100 0 .01 .05 .1 .5 1 REVERSE VOLTAGE,(V) 5 10 50 100 .01 0 20 40 60 80 100 120 140 PERCENT OF RATED PEAK REVERSE VOLTAGE,(%)