HG-0711 Shipped in packet-tape reel(10,000pcs per reel) Notice : It is requested to read and accept "IMPORTANT NOTICE" written on the back of the front cover of this catalogue. Absolute Maximum Ratings Symbol Item Conditions Max. Input Voltage Unit 10 V 150 mW Ta=25 P Max.Input Power Limit Operating Temp. Range Topr 40 125 TSTG 40 150 Storage Temp. Range Dimensional Drawing (Unit : mm) Electrical Characteristics(Ta=25 ) Item Symbol Output Hall Voltage VH Rin Input Resistance Output Resistance Min. Typ. Max. Unit B=50mT, VC =6V 55 130 75 mV B=0mT, IC =0.1mA 650 750 850 Rout B=0mT, IC =0.1mA 650 750 850 Conditions VOS (Vu) B=0mT, VC =6V Offset Voltage mV VH B=50mT, =5mA Ta=25 125 %/ Rin B=0mT, =0.1mA Ta=25 125 %/ Temp. Coefficient of VH Temp. Coefficient of Rin 11 11 B=0.1/0.5T, Linearity % =5mA No.3 and No.5 terminals are electrically connected. Notes : 1. VH = VHM –VOS (Vu) (VHM:meter indication) 1 2 ) – VH (T1 ) X 100 2. VH = VH (T1 ) X VH (T (T2 – T1 ) 1 Rin(T2 ) – Rin(T1 ) 3. Rin= Rin(T1 ) X X 100 (T2 – T1 ) K (B1 ) – K (B2 ) 4. K = [K (B1 ) + K (B2 )] / 2 X 100 T1 = 25˚C, T2 = 125˚C K= VH IC • B Land pattern (for reference only) (Unit : mm) B1 = 0.5T, B2 = 0.1T Characteristic Curves Allowable Package Power Dissipation 200 Max. Input Power 160 120 80 40 0 0 20 40 60 80 100 Ambient Temperature(˚C) 39 120 140 HG-0711 •AKM products are neither intended nor authorized for use as critical components in any safety, life support, or other hazard related device or system, and AKM assumes no responsibility for such use, except for the use approved with the express written consent by Representative Director of AKM. •Handling precautions required for preventing electrostatic discharge. •This product contains galium arsenide(GaAs).Handling and discarding precautions required. Characteristic Curves 1000 600 Output Hall Voltage Input Resistance IC const 500 800 600 400 200 0 –50 0 50 100 VC const IC =10 [mA] VC = 6 [V] Ta =25 [ ] 400 300 100 120 IC = 10 [mA] VC = 6 [V] B = 50 [mT] IC VC IC B = 50 [mT] Ta = 25 [] 20 20 50 100 0 150 8 IC 0 6 8 10 const VC B = 0 [mT] Ta = 25 [] 10 const 3 const 2 IC =10 [mA] VC = 6 [ V ] B = 0 [mT ] 1 0 50 100 150 Offset Voltage Offset Voltage 4 const IC 4 0 -50 2 15 7 5 VC 60 40 0 VC 80 40 0 50 IC 100 VC 60 6 300 Magnetic Flux Density 120 80 200 100 Ambient Temperature(˚C) 100 VC 200 0 0 150 IC VC 5 0 IC 0 2 Ambient Temperature(˚C) Magnetic Flux Density 1[mT]=10 [G] In This Example : =750 4 6 Input Current Input Voltage , =4.6 8 , 10 =6 V 40 重要注意事項 ● 本書に記載された製品、および、製品の仕様につきましては、製品改善のために予告なく変更することがあ ります。従いまして、ご使用を検討の際には、本書に掲載した情報が最新のものであることを弊社営業担当、 あるいは弊社特約店営業担当にご確認ください。 ● 本書に記載された周辺回路、応用回路、ソフトウェアおよびこれらに関連する情報は、半導体製品の動作例、 応用例を説明するものです。お客様の機器設計において本書に記載された周辺回路、応用回路、ソフトウェア およびこれらに関連する情報を使用される場合は、お客様の責任において行ってください。本書に記載された 周辺回路、応用回路、ソフトウェアおよびこれらに関連する情報の使用に起因してお客様または第三者に生じ た損害に対し、弊社はその責任を負うものではありません。また、当該使用に起因する、工業所有権その他の 第三者の所有する権利に対する侵害につきましても同様です。 ● 本書記載製品が、外国為替および、外国貿易管理法に定める戦略物資(役務を含む)に該当する場合、輸出 する際に同法に基づく輸出許可が必要です。 ● 医療機器、安全装置、航空宇宙用機器、原子力制御用機器など、その装置・機器の故障や動作不良が、直接 または間接を問わず、生命、身体、財産等へ重大な損害を及ぼすことが通常予想されるような極めて高い信頼 性を要求される用途に弊社製品を使用される場合は、必ず事前に弊社代表取締役の書面による同意をお取りく ださい。 ● この同意書を得ずにこうした用途に弊社製品を使用された場合、弊社は、その使用から生ずる損害等の責任 を一切負うものではありませんのでご了承ください。 ● お客様の転売等によりこの注意事項の存在を知らずに上記用途に弊社製品が使用され、その使用から損害等 が生じた場合は全てお客様にてご負担または補償して頂きますのでご了承下さい。 2013 年 2 月 1 日現在 IMPORTANT NOTICE These products and their specifications are subject to change without notice. When you consider any use or application of these products, please make inquiries the sales office of Asahi Kasei Microdevices Corporation (AKM) or authorized distributors as to current status of the products. Descriptions of external circuits, application circuits, software and other related information contained in this document are provided only to illustrate the operation and application examples of the semiconductor products. You are fully responsible for the incorporation of these external circuits, application circuits, software and other related information in the design of your equipments. AKM assumes no responsibility for any losses incurred by you or third parties arising from the use of these information herein. AKM assumes no liability for infringement of any patent, intellectual property, or other rights in the application or use of such information contained herein. Any export of these products, or devices or systems containing them, may require an export license or other official approval under the law and regulations of the country of export pertaining to customs and tariffs, currency exchange, or strategic materials. AKM products are neither intended nor authorized for use as critical componentsNote1) in any safety, life support, or other hazard related device or systemNote2), and AKM assumes no responsibility for such use, except for the use approved with the express written consent by Representative Director of AKM. As used here: Note1) A critical component is one whose failure to function or perform may reasonably be expected to result, whether directly or indirectly, in the loss of the safety or effectiveness of the device or system containing it, and which must therefore meet very high standards of performance and reliability. Note2) A hazard related device or system is one designed or intended for life support or maintenance of safety or for applications in medicine, aerospace, nuclear energy, or other fields, in which its failure to function or perform may reasonably be expected to result in loss of life or in significant injury or damage to person or property. It is the responsibility of the buyer or distributor of AKM products, who distributes, disposes of, or otherwise places the product with a third party, to notify such third party in advance of the above content and conditions, and the buyer or distributor agrees to assume any and all responsibility and liability for and hold AKM harmless from any and all claims arising from the use of said product in the absence of such notification. February 1, 2013