HA15-2 - Hamlin

BENEFITS
APPLICATIONS
•
•
•
•
•
•
•
•
•
•
•
•
Hermetically sealed switch
Contacts have no effect on their
external environment
Low space requirement
Zero operating power required
Fit and forget durability
Reed Relays
Security
Limit Switching
Telecoms line switching
Office equipment
Light inductive loads
European mains Voltage Switching
HA15-2
Dimensions: (inch)
mm
Switch type
Contact Form
Underwriters Laboratories Recognized, File E47258 (1)
ELECTRICAL RATINGS
Sensitivity (5)
Contact Rating (2)
Watts - max
Switching
VAC rms max / VDC
Breakdown
VDC - min
Switching
A - max (AC/DC)
Current
Carry
A - max (DC)
Contact, Initial
Ω - max
Resistance
Insulation
Ω - min
Capacitance
Contact
pF - typ
Operating
°C
Temperature
Storage (6)
°C
OPERATING CHARACTERISTICS
Operate time (3)
ms - max
Release Time (3)
ms - max
Shock
11ms 1/2 sine wave
G - max
Vibration
50-2000 Hertz
G - max
Resonant
Frequency
Hz - typ
MAGNETIC CHARACTERISTICS
Pull-in Range (4)
Ampere Turns
Test Coil
Voltage
Notes
1)
2)
3)
4)
5)
6)
HA15-2
A (SPST)
17-23
22+
20 W for 100-265 VAC loads
10 W for all other loads
265 / 200
265 / 200
400
450
0.3 / 0.4
0.35 / 0.5
1.4
1.5
0.100
0.100
10¹⁰
10¹⁰
0.2
0.2
-20 to +125
-20 to +125
-65 to +125
-65 to +125
0.6
0.2
100
30
4000
17-23, 22-28, 27-33
L4989
For details on electrical specifications contact Hamlin
Contact rating-Product of the switching voltage and current should never exceed the wattage rating. Contact Hamlin for additional load/life information
Operate (inc. bounce / Release Time-per Eia/NARM RS421A, diode suppressed coil.
Pull in Range-Contact Hamlin for tolerances within this range.
Rating Sensitivity, The value at which contact ratings and operating characteristics are determined. Derating may be required for lower values
Storage Temperature-Long time exposure at elevated temperature may degrade solderability of the leads.
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
Hamlin China
Tel: +1 920 648 3000
Tel: +44 (0) 1379 649700
Tel: +49 (0) 6142 923920
Tel: +33 (0) 1 6047 3000
Tel: +86 512 69365 800
Fax: +1 920 648 3001
Fax: +44 (0) 1379 649702
Fax: +49 (0) 6142 923921
Fax: +33 (0) 1 6015 9136
Fax: +86 512 69365 817
Email: [email protected]
Email: [email protected]
Email: [email protected]
Email: [email protected]
Email: [email protected]
DETAILS ON THIS DATA SHEET ARE PROVIDED FOR INFORMATION PURPOSES ONLY &
SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE
Product performance may be affected by the application that the part is used for.
Upon request Hamlin will assist purchasers by providing information specific to a particular application.
Hamlin disclaims all liability whatsoever for any purchaser’s reliance upon the information
contained in this data sheet without further consultation with Hamlin’s authorised representatives.
Issue no. AB
2011-08-11
DCR B8057
Page 1/2
HA15-2
PI vs DO
BREAKDOWN VOLTAGE
TYPICAL LIFE TEST RESULTS
Life test notes:Each operation monitored for failure to open or close.
15-20 samples each test.
End of life criteria: >10% failure.
Results may vary with such factors as pull-in, circuit reactance or drive method.
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
Hamlin China
Tel: +1 920 648 3000
Tel: +44 (0) 1379 649700
Tel: +49 (0) 6142 923920
Tel: +33 (0) 1 6047 3000
Tel: +86 21 68062833
Fax: +1 920 648 3001
Fax: +44 (0) 1379 649702
Fax: +49 (0) 6142 923921
Fax: +33 (0) 1 6015 9136
Fax: +86 21 62424802
Email: [email protected]
Email: [email protected]
Email: [email protected]
Email: [email protected]
Email: [email protected]
DETAILS ON THIS DATA SHEET ARE PROVIDED FOR INFORMATION PURPOSES ONLY &
SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE
Product performance may be affected by the application that the part is used for.
Upon request Hamlin will assist purchasers by providing information specific to a particular application.
Hamlin disclaims all liability whatsoever for any purchaser’s reliance upon the information
contained in this data sheet without further consultation with Hamlin’s authorised representatives.
Issue no. AB
2011-08-11
DCR B8057
Page 2/2